Document zQqR7BjL6obvjKR2r1pBamv6g

556 CHAPTER 26 1949 Guide Table 3. Typical Capacities op Unit Ventilators fob an Entering Air Temperature of Zero Cubic Feet of J ta peb Minute Total Capaott in Squabs Feet, Rating Condensate Rating Equivalent Di rect Radiation Capaott Available fob Heating theRoom, Squabs Feet Equivalent Dibect Radiation Final Aib Tempebatube F Deg i! ! 750 500 214 56 95 1000 750 320 84 95 1260 1000 427 112 95 1560 1250 534 141 95 I the quantity of air delivered and the temperature of the air to and from the. unit. Table 3 shows the air handling capacities by the two methods of rating5 and also the approximate heating data. In accordance with the i A.S.H.V.E. Standard Code for Testing and Rating Steam Unit Ventilators the information to be supplied regarding ratings and the basis of rating is the following: |( If . Rating Factors to Be Specified. The rating of the unit ventilator shall specify the following: a. Final temperature at different entering air temperatures. b. Total EDR at different entering air temperatures. c. Air delivered by the unit in cubic feet per minute at the standard basis of rating with the fans operated at rated speed, with all air being blown through the heating unit and with the standard louver and grille oh the outlet. The Standard Basis of Rating shall be as follows: r . Dry saturated steam at a temperature at the unit corresponding to an absolute pressure of 16.7 psi (218.5 F). i . Entering air temperature of aero Fahrenheit degrees. c. Volume delivered in cubic feet per minute converted to standard air at 70 F. Rating Tables for unit ventilators shall contain the following data in addition to the standard rating, for entering air temperatures from --30 F to +60 F: . Inlet temperature, Fahrenheit degrees. . Final temperature, Fahrenheit degrees. c. Total EDR at the specified entering temperature. d. Surplus or heating EDR at the specified entering temperature. Surplus or Heating Equivalent Direct Radiation for the purposes of this code shall be construed to mean difference between the total EDR at a specified inlet temper ature and the EDR required to heat the air from that temperature to 70 F. If no direct heating surface (radiation) is installed to take care of the normal heat transfer losses, and the unit, ventilator is to be used for both heating and ventilation, then the combined requirements must be taken care of by the unit ventilator. Heat Required for Ventilating Only - , When all of the air handled by the unit is taken from the outside, the total heat to be supplied is obtained by means of Equations 1, 2, 3, and 4: H = 0.24 IF (t, -- 0 H, = 0.24 W (t -- to) Ht = 0.24 W (tj -- I*) = H + Hr IF = d 60 Q From Equations 2, 3, and 4: (1) - (2) (3) (4) Hi = H + 0.24 d 60 Q (t - J,,). . (5) Unit-Heaters, Unit Ventilators, Unit Humidifiers . 557 where . .v d = density of air, pounds per cubic foot (0.075 lb per cu ft for Standard Air by definition).. H = heat loss of room, Btu per hour. ' Hr = heat required to warm air for ventilation, Btu per hour. Hi -- total heat requirements for both heating and ventilation, Btu per hour. Q = volume of air handled by the ventilating equipment, cubic feet per minute. t = temperature to be maintained in the room, Fahrenheit degrees. t0 = outside temperature, Fahrenheit degrees. t, = temperature of the air leaving the unit, Fahrenheit degrees. yf -- weight of air circulated, pounds per hour. : 0.24.= specific heat of air at constant pressure (approximate value). Example I. The heat loss of a certain room is 24,000 Btu per hour, and the venti lating requirements are 1000 cfm. If the room temperature is to be 70 F and ill air is taken from the outside at zero, what will be the total heat demand on the unit if it is required to provide for both the heating and ventilating requirements (combined system)? Solution. Substituting in Equation 5: Hi = 24,000 + 0.24 X 0.075 X 60 X 1000 (70 - 0) = 99,600 Btu per hour ________ 24,000 fjr 0.24 X 0.075 X 60 X 1000 + 70 92.2 F. Heat Required for Ventilating and Recirculating When part of the air handled by the unit is taken from the room and the remainder from the outside, . Hi = 0.24IFo (f, - to) + 0.24 IF, ((,-!)Wo = do 60 Q,, IF, = di 60 Qi H <r ~ 0.24 (IF. + Wd + 1 (7) (8) (9) (10) ff = H + 0.24 do 60 Qo (t - to) where' ' '-'JFo = weight of air, pounds per hour taken from out-of-doors. IF, = weight of air, pounds per hour taken from the room. d0 = density of air, pounds per cubic foot at temperature to. di = density of air, pounds per cubic foot at temperature t. Qo = volume of air taken in from the outside, cubic feet per minute. Q, = volume of air taken in from the room, cubic feet per minute... (11) Applications of Unit Ventilators . Items to be considered in the application of unit ventilators are: (I) combination with other means of heating, (2) location of units, and (3) method of venting or exhausting. In a split system the unit is used primarily for ventilation. . Air is delivered to the room at or slightly above room temperature, and enough radiation is installed in the room to take care of the normal heat transfer, losses. Where the unit ventilator selected has a capacity more than suffi-