Document zQp7k23RJX5KEmYod7gQ08XEn

I UCN9SUI KtOUSNS GENERAL tfgfr ELECTRIC , WVW tOAD, SCHtKECTAOY, H. Y. 12305 lUBflCT 1 8*235-2261 I STATUS nZPORI TO CUSTOMERS ON PCB July 24, 1972 comti J. F. Young J. F. McAllister J. S. Anderson C. H. Batcua J. V. Blake D. F. Croat L. 1. Dengler E. L. Dobblna . J. A. Donnelley R. W. Frahm D, A. Frank* W. B. Calther C. H. love V. P. Hamby V. T. Kinsey H. D. laube 0. H. leBlane V. F. Marx ' V. F. Powell A. Potefsky E. L. Raab J. F. Repko W. K. Rodger* E. R. Ruterman E. li Simona H. B. William* Messrs K. H. Christiansen - Agency & Distributor Sale* Dlv. . * r. - V. 1. Clarke - Apparatus Sale* A Service Dept. - Canadian CE / ; 6. V. Corbin - Induatrial Sales Dlv.' . . ' ..... . ' . ' J. J. Farrell * Power Transformer Products Dept, ' C. H. Hupman - International Bus. Support Operations .. L. P. Hart, Jr. Industrial A Power Capacitor Products Dept. R. T. Morris - Medium Transformer Products Dept. .' I. J. Petersen - Distribution Transformer Products Dept. . D. F. Ranklne - Power Transmission A Distribution Dept. ^.Canadian CE W. R. Thckaberry Power Transmission A Distribution Seles Dlv. C. C. Thomas - Installation A Service Engrg. Business'Dept. . . P. C. .Van Dyck - Apparatus Service* Business Dlv. General Electric customers were informed In 1970 of the environmental concern which had arisen over polychlorinated biphenyl materials (PCS'*) through the vide* spread distribution of the "Open letter to Industrial Customers" and "Open Letter to Electric Utility Customers" and by ether mean*. Since that tine a great deal hat been accomplished to bring this situation under control. In particular, the responses of cognisant agencies of the federal government have attuned a greater degree of . predictability. How that the Interdepartmental Task Force report has been published, we can give customer* additional assurance that there will be a continued source of. * " supply of Pyranol capacitors and transformer* and that their application Is consonant . with the public interest. The.accompanying statement has been prepares as a basis for such customer communication, and- has been approved by legal counsel of the Transformer and Distribution Equipment Division and the Electronic Components Division. keJUo--- / James S. Kelson, Consultant ^^roduet Environmental Compatibility MONS 056171 JSNtcv Attachment Ji.= 20 1 9 ADVICE TO GENERAL ELECTRIC CUSTOMERS CONCERNING PC3 (PYRAN'OLl m I. FEDERAL GOVERNMENT REPORT SANCTIONS CONTINUED USE OF PCB IK TRANSFORMERS Central Electric customer* msy continue to purchase end apply Central Electric Fyranol transformer* and etpacltors, secure in the knowledge that all cognisant US government egencies are'parties to a report sanctioning the continued use of polychlorinated biphenyls (PCB) in such apparatus. The following paragraph .is quqted from one of the findings in which the government's Task Force.concurred: "6. The use of FCB's should not be banned entirely. Their continued ' use for transformers and capacitors in the near future is considered necessary because of the significantly Increased risk of fire end ; . explosion and the disruption of electrical service which would result, from a ban on FCB use. Also,' continued use of FCB's in transformers and ` capacitors pesenta a minimal risk of environmental contealnetlon. The Monsanto Company, the sole domestic producer, has reported voluntaVliy ' eliminating its distribution of FCB's to all except manufacturers of electrical transformers and capacitors.'' --FCB's and the Environment, by the Interdepartmental Task Force on FCB's sponsored by tfep Departments of Agriculture; Coarserce; Health, Education, and Welfare; and Interior. ' Aleo eponeored by the Environmental Froteetion Agency, plus other ptrtlci- paring agencies. Published May, 1972, distributed by KTIS, Springfield, Virginia 22151, under access number CCM-72-10419. The report may be ordered for $6.00. .' 2. APPLICATIONS TO THE FOOD INDUSTCT . -. The FDA he a lasted e-ptopbsedrulereaklng concerning the epplleatlon of FCB's in human foods; animal'feeds, add food-packaging material (Federal Register, 37-54-5703, Kerch 18,1972). From our reading of the proposed rule, it does not appear-to be the intent, to'outlav.-elther capacitors or transformers when applied in accordance with the manufacturer's ratings'and installed eeperetely from that equlp- merit which la.in direct-contest'with the food; feed, or food-packaging material . being proceaeed. We have written' to' the"Hearing Clark of the Department of Health; " - Education, end Welfare-with the Suggestion that the exemption of capacltore end . transformer* eo applied be'msdS-Sxpllclt In the -final version of the proposed rules. ' V anticipate concurrence 'by the Department'of"HEW, In view of the following paragraph contained In their-Draft Environmental lepact Statement of May 8, 1972, regarding the Notice of Proposed Rule Making, Polychlorinated Biphenyls: . "3. An exception to the propoatd special provision* eliminating - ' certain Induetrlal usta of PCB'a will permit the continued use of electrical power equipment containing FCB'o In regulated establishments. Title use of FCB's 1* considered eunentlel and prosenta only a minimal . . risk ul accidental contamination of food end the enviro.-mvat." HONS 056172 i Q 2 3. ANTICIPATED LEGISLATION , ., It vlU ba noted that progress In controlling poislble adveras environ* .mental effect* from PCS'* ha* come about largely a* the result of private Industry .'Initiative* In Halting application* to situation* vhlch are controllable, I.e., the use of PCD'* In sealed transformer* and capacitor*. A* noted In the Task Force report cited above s ' ' '' ' ( "The govarnaent has no power to restrict Import* of PCS'* by foreign manufacturer* and If It disagreed with Monsanto'* Judgatnt - .on allowable uses it could not Impose nora stringent limitations , on Monsanto or on any other potential manufacturer. ,' ' . * ' I'Thls regulatory gap vould be filled by the Administration's proposed ' Toxic Substances Control Act...." ' - '. ' Ve pee no reason to anticipate that the passage of the Toxic Substances Control Act will affect the continued availability of CZ Pyranol transformer* and ' capacitors. While more restrictive legislation vat at one time proposed (by' ' Congressman Ryan of New York), it vat prepared before the findings of the ak F* orce were available, and has ne.ver.com.e out of cossiltte*. ' 4. APPARATUS FOR EXPORT . . '. Those Intending to. export PCB-contalnlng apparatus to certain foreign countries are 'advised to cheqk for possible import restrictions. Japan and Sweden, for example, are khovo'tb have enacted'restrictive legislation and/or license requirements. i. DISPOSAL . . - The electrical Industry', having' recognised that continuation of the public benefit* resulting from the use of PCB's rest* In part upon industry cooperation and success In keeping this material out of the country's water system, has. formed Committee C107 of the American National Standards Institute to erect guidelines' for the proper handling of PCB's In manufacture and upon ultimata disposal. General Electric intends to promote full compliance vlth these guide lines, thus helping to Implement 'an' additional recommendation contained In the Interdepartmental Task Force Report, namely, "an educational campaign mimed at users' to assure proper disposal." The ANSI guidelines are expected to provide for hlgh-temperstura Incineration of.surplus PCB liquids (e.g., fluid discarded froa a transformer) and disposal In properly-managed land-fill operation* of solid material vhlch has been In caitact vlth PCB's (e.g., discarded capacitors). Three pertinent statements froa the Task Force report nay be noted In connection with . these proposed procedures: (1) "Incineration at 2000 F or above for two seconds will destroy PCB'*...." ' . (2) "PCS containing material burled in'soil Is not expected to migrate " but should remain In piece." HONS 056173 3 <3) "PCS'* are being designated at hazardout substances under" Section 12 (of the Federal Water Pollution Control Act), and the authority contained in Che aeetlon could be ueed if an accidental spill of PCB'a into water should occur." (The referenced authority concerns notification and clean-up responsibilities, etc.) ' -. Pending promulgation of the ANSI guidelines, those With a disposal problen are requested to contact the appropriate General Electric field sslgs office. HONS 056174