Document zQmN7b9YgZa88VKRMowyZnKMg
To: R* Bryan, Westlake, LA
interoffice Communication
From: I5ate;
P* R- Fetizanan, Houston, TX January 30, 1985
Subject: INCINERATOR GAS TIP EVALUATION--VCM PLANT
VISTA
The operating pressure of the wet and dry vent headers can be signi ficantly reduced by changing the "gap" in the incinerator gas tip from 9/16" to 13/16". A sketch of this gas tip and the estimated pressure drop are shown in Figs. 1 and 2, respectively. Reducing the header pressures would allow operation of the tank farm blowers at lower discharge pressure and increase the vent system's surge capa city during upset condition.
The acid gas tip was originally designed to handle only the dry vent. Burner ring assembly modifications in the Liquid Flame Arrestor <3-2__- mo. project, however, eliminated the wet vent nozzle and the combined vents now enter the combustion chamber through this gas tip. The resulting vent header pressure increase had required some equipment modifications. The velocity through the tip at a minimum flow of 5000 SCFH is estimated at approximately 12 ft/sec. John Zink had estimated a flame propagation velocity of less than 5 ft/sec. for the system.
We recommend this dimension change be incorporated in the next tip
ordered. Howell Industries, Sulphur, LA, currently fabricates this
item. Although the recently modified high-speed Paxton blowers are
operating satisfactorily, long term operation may dictate a need to
reduce the RPM to minimize maintenance problems. Speed reduction 7 oe_
would be possible after the modified tip is installed.
J f* /wee. /n
'^NT f+tAfc;/e
Please give me a call at (713) 531-3248, in Houston if you have any
/Is cc: RAC, PEM, JRH, MLA, DLD, SCR - LCVCM
CRD, RWC, LZK File A-127.1
001/PFF
CCR 00002U68
l<4*&
PLATBZ.
FIG /
INCINERATOR. GAS TIP
PART # BC-70S LCVCM
CCR 000021169 )
PFF nj2l/8f.
FIG. 2
GAS TIP AP LCVCM PLANT