Document zQdbaZbQ697dzey5M0XwOQxaR

Monsanto Chemical Company Anniston Method IJo. 14-24-48 C5JBJECT: Flash and Flame Points METHOD: Cleveland Open Cup The flash and flame points of Aroolor shall he determined in the Cleveland Open Cup Tester, following the procedure described in A3TL3 D 92-33. Apparatus The cup shall be supported by a metal plate 1/4" (.635 cm) in thick ness and 6 inches (15.24 cm) in width. The plate shall be of brass, cast.iron, wrought iron, or steel. In the center of the mlate there shall be a plane depression 1/32* (.079 cm) in depth, and of just sufficient diameter to fit cup. There shall be a circular opening 2 3/16*' (5.50 cm) in diameter, cut thru the plate, centering with the center of the above mentioned depression. The plate shall be covered with a sheet of hard asbestos board 1/4" in thickness, and of the same shape as the metal plate. There shall be cut in the center of the as bestos board a circular hole just fitting the cup. neat may be supplied from any convenient source. The use of a gas burner, electric heater, or alcohol lamp is permitted, but under no circumstances ere products of com bustion or free flame allowed to come up around the cup. The source of heat shall be centered under the opening in the plate and shall be of a type that will not produce local superheating. If a flame heater is used, it may be protected frqm drafts or excessive radiation by any suitable type of shield, that does not project above the level of the upper surface of the asbestos board. The thermometer shall conform to the requirements of thermometer No. 8. (3ee A7I1.I table of thermometers). Procedure The thermometer shall be suspended or held in a vertical oosition by any suitable device, the bottom of the bulb shall be 1/4 in. (.635 cm) from the bottom of the cup, and above a point half way between the center and back of the cup. The cup shall be filled with oil to be tested in such a manner that the top of the meniscus is exactly at the filling line at room temperature. The surface of the oil shall be free from bubbles. There shall be no oil above the filling line or outside of apparatus. The test flame .shall be approximately 5/32" (.397 cm) in diameter. The test flame shall be applied as the temperature read on the thermo meter reaches each successive 5F mark. The flame shall pass in a straight line, (or on the circumference of a circle having a radius of at least 6 inches.) across the center of the cup and at right angles to the diameter passing thru the theimometer. The test flame shall, while passing across the surface of the oil, be in the plane of the upper edge of the cup. The time for the passage of the test flame across the cum shall be approxi mately 1 second. DSW 330865 STLCOPCB4077509 Flash and Flame Points -2 - The oil shall be heated at a rate not exceeding 50*F per.minute tem perature rise till a point is reached approximately 100eF beloiv the probable flash point of the oil. Thereafter the rate of heating shall be decreased and for at least the last 50F before the flash point is reached the rate shall be not less than 9*F. or more than'll*F per minute. ' The flash point shall be taken as the temperature read on the thermo meter when a flash appears at any point on the surface of the oil. The true flash must not be confused with a bluish halo which sometimes surrounds the test flame. After determining the flash point, the heating shall be continued at the specified rate of 9*F to 11F per minute,, and application.of the test flame shall be made at the specified intervals until the oil ignites and con tinues to burn for a period of at least five seconds. The method of application of the flame shall be the same as for flash point. The tem perature read at the time of the flame application, which causes burning for a period of five seconds or more, 3hall be recorded as the flame point. The flash point and flame point tests shall be made in a room or com partment free from air drafts. The operator shall avoid breathing over the surface of the oil. It is desirable that the room or compart ment may be darkened sufficiently so that the flash may be readily dis cernible. Note Aroclor3 1248, 1254, 1260, and higher chlorinated Aroclors do not have a distinct flash or flame point below their boiling temperatures. FAB:cm 1-26-45 Copied by rs 4/21/48 DSW 330866 STLCOPCB4077510