Document zQMyk5JG8gQv1w42r8v4YaY8a

Lancer Dispersions, Inc. 1680 East Market St Akron, Ohio 44305-4246 * (216) 794-9922 Toll-Free (outside Ohio) 1-800-722-9911, QUALITY CONTROL PROCEDURE FOR CKR INDUSTRIES . INC . I. Pi suers ion' .- Procedure: Prepare samples of both the standard & trial concentrate according to the following letdown procedure : (1) Place 200g of specified PVC base* on a 12" 2-roll mill heated to 300F 10 (roll temp.) and band. Carefully add 6 grams of concentrate,, making sure none ' falls through the band. (2) Work batch continually, on the slow roll, for three minuteB. Cut off sheet and lay flat.. , . (3) Examine sheet for streaks undispersed concentrate* and/or (4) If color is not completely dispersed, reject the batch and adjust plant formula card. If dispersion is acceptable, evaluate color. 11 , Color Eva luation Procedure: (1) Using prepared sheets press out standard vs. sample side by side. Use Carver compression press heated to 350F. Remove and,water cop 1 . .. ^ (2) Visually .-examine panel for chroma and hue variations. (3) Read the panels on a spectrophotometer taking an average of three readings on both the standard and sample. Readings shouj^ be taken using CIE L*A*B* D65. Cause for rejection is a variable of greater than 0.5 on a*b* or L* coordinate. (4) Blend dispersion into 'a consistent 2000 pound lot and report quality control results to CKR Industries. CHARDO 02215 III. Particle Size Apparatus: Sieves -1/4" Balance Pre cedure: (1 ) Weight 400g of dispersion into appropriate sieve size. C 2 ) Shake dispersion through screen determine percentage retained. and (3) Reject the material if 1% or greater is retained on the indicated sctefen. * PVC base is to be supplied by Chardon Rubber. Use appropriate base as indicated by the product code. 70 duro 90 duro CHARDO 02216 Nurnerica 1 Color Evgluation Using an MS-2000 Epectropbotometer, color variation can be determined .using three different mathematical formulations. These are : Hunter LAE units CIE L*A*B* units FMC XI units Each of these units are derived from different mathematical formulas using <the data obtained from the sample reflectance curve. Although they vary in their means , each place the sample in a certain color space. The spectrophotometer plots this space out in the following manner with the standard being zero: (+) Yellow (+> Light Green(-)----------------- 1r--------------- ( + )Red <-) Blue \ (-)Dark The color formulas described above are dependent on the sample and the Light source used. The MS-2000 spectrophotometer has the ability to simulate the following Light sources: Incadescent Fluorescent Daylight 65 Northern Sky ,, '' , Each of these sources are determined-by. industry.standards * CIE L*A-*B*~and-. D65 are-norntally. use4^ byitherp las tics ^industry, - CHARDO 02217