Document zQLwz48QMNk6VbkVGKkDV7Jw3
732
CHAPTER 52
1960 Guide
*P. Drinker and T. Batch: Industrial Dusts (McGraw-Hill Book Co, New York, 1936).
B P. S. Hay: Modified design of Hay dust trap (Journal of Industrial Hygiene, January 1930, p. 28).
' J. L. Alden: Design of Industrial Exhaust Systems (In dustrial Press, New York, 1944).
' W. N. Witheridge: Ventilation (Industrial Hygiene and
* American Standard for Grinding, Polishing and Buffing Equipment Sanitation (American Standards Association Z 431941).
Toxicology, VoL 1, Chapter 10, ed. F. A. Patty, Interscienee Publishers, New York, 1948).
"J. M. Kane: Swing frame grinder dust control (The Foundry, August 1944).
"A. C. Stem etal: Transport velocities for industrial dusts (American Industrial Hygiene Association Quarterly, December 1948).
nA. D. Brandt: Industrial Health Engineering (John Wiley and Sons, New York, 1947).
L. Silverman: Velocity characteristics of narrow exhaust slots (Journal of Industrial Hygiene and Toxicology, November 1942, p. 267).
" W. C. L. Hemeon: Plant and Process Ventilation (The In dustrial Press, New York, 1955).
u Code of Recommended Good Practice for Metal Cleaning Sanitation (American Foundrymen's Association).
" Industrial Ventilation Manual (American Conference of Governmental Industrial Hygienists, 1958, 5th ed.).
* J. M. DailaValle: Design of kitchen range hoods (Heating and Ventilating, August 1953, p. 95).
** What We Make (B. F. Stwtevant Co. Catalog No. 500).
"P. Drinker and J. R. Snell: Ventilation of motion picture Booths (Journal of Industrial Hygiene and Toxicology, April 1938, p. 321).
** P. J. Marachall: How to justify an industrial air condition ing investment (Heating, Piping and Air Conditioning, February 1952, p. 71).
u E. C. Riley et al: How to design exhaust hoods for quartz fusing operations (Heating and Ventilating, April 1940, p. 23).
* E. C. Riley and J. M. DallaVaQe: A study of quartz-fusing operations with reference to measurement and control of silica fumes (U. 8- Public Health Reports, 1939, Vol. 54, p. 532).
" W. C. Dressen et al: A Study of Asbestosis in the Asbestos Textile Industry (I/. S. Public Health Service Bulletin No. 241, 1938).
" R. T. Page and J. J. Bloomfield: A Study of Dust Control Methods in an Asbestos Fabricating Plant (U. S. Public Health Reports, Reprint No. 1883, November 1937).
" A. C. Stem: Ventilation of open tanks (Industrial Hygiene Quarterly, September 1950).
BI. Kingsley: Tabulation of atmospheric contaminants re leased by open surface tanks (New York State Department of Labor, Division of Industrial Hygiene, Engineering Unit Plates 161, 162, 163).
" Rules Relating to the Control of Silica Dust in Stone
Crushing Operations (New York State Department of Labor, Industrial Code Rule No. 34, July 1942).
**K. M. Morse and L. Goldberg: Chlorinated solvent ex posures at degreasing operations (Industrial Medicine, October 1943, p. 706).
"J. M. Kane: Design of exhaust systems (Heating and Ventilating, November 1945, p. 68).
J. M. Kane: Foundry ventilation (The Foundry, February, March 1946).
" W. M. Oddie: Pottery dusts: their collection and removal (Pottery Gazette, Vol. 53,1928, p. 1280).
" W. N. Witheridge and H. T. Walworth: Ventilation of a trichlorethylene degreaser (Journal of Industrial Hygiene and Toxicology, May 1940, p. 175).
* American Standard for Safety in Electric and Gas Welding and Cutting Operations (American Standards Association. A 49J).
BJ. M. Kane: 8crapbook of exhaust hood design (Heating and Ventilating, July, August, November 1950 and February, March, April, Jane 1951).
a Rules Relating to the Removal of Dust, Gases, and Fumes (New York State Department of Labor, Industrial Code Rule No. 12, January 1931).
"R. T. Pring et al: Design of exhaust ventilation for solid material handling (Industrial and Engineering Chemistry, No vember 1949).
"T. F. Hatch and D. Barron-Oornzco: Air flow in free con vection over heated bodies (ASHAE TaANSACttoNS, Vol. 63, 1957, p. 275).
| MHartseU Blowers: Engineering Data <fc Installation (HartteU Propeller Fan Company Bulletin 1001).
A. D. Brandt and R. J. Steffy: Energy losses at suction hoods (ASHVE Transactions, Vol. 52, 1948, p. 205).
* J. M. Kane: The application of local orhanst ventilation
"A. Nutting: Resistance test on pipe (Mechanical Engineer-
to electric melting furnaces (American Foundrymen's Associa mg. May 1938).
tion Transactions, VoL 52, 1945, p. 1351).
" G. E. McElroy: Design of Injector for Low Pressure Air
* T. Hatch et al; Control of silicosis hazard in the hard rock Plow (U. S. Bureau of Mines Technical Paper 678).
! industries. II. An investigation of the Kelley dust trap for use with pneumatic rock drills of the jackhammer type (Journal of Industrial Hygiene, February 1932, p. 69).
** American Standard Safety Code far Ventilation and Op eration of Open Surface Tanks (American Standards Associa tion, Z 9J-1951).
CHAPTER 53
INDUSTRIAL DRYING SYSTEMS
Drying Terminology, Mechanism of Drying, internal and External Conditions, Periods of Drying, Equilibrium Moisture Content, Application of Hygrometry to Drying, Determination of Drying Time, Commercial Drying Time, Dryer Calculations, Drying Method* and Equipment; Rodiant, Conduction, and Convection Drying; Agricultural Drying, Solution of Drying Problem
THE term drying, in a broad sense, encompasses the re and from the dryer. The operating conditions are independent
moval of water, and occasionally other liquids, from of time.
gases, liquids, or solids. However, the common usage of word confines the meaning principally to the removal of water or solvent from solids by thermal means. Dehumidified-
theratCerpiteicraioldmeonisdtsuraencdonthteentfaisllitnhga-troabtetapineirniogdwbheegnintsh.e constant-
Equilibrium moisture content is that to which a given material can be dried under specific conditions, of air temperature and
lion is the term that is commonly assigned to the drying of humidity.
gases. This is usually accomplished by condensation or ad sorption by various drying agents, and is treated in Chapter
Evaporative load is the total amount of water evaporated per hour in the dryer.
42. Distillation, and more particularly fractional distillation, is associated with the drying of liquids.
It is usually more economical to employ, whenever possi ble, mechanical means of separating as much water as is practicable from the solid materials before undertaking dry ing or dehydration steps. These mechanical methods such as filtration, screening, pressing, centrifuging, or settling usually require much less power, and frequently les' capital outlay, thereby making the operation cheaper in terms of cost per pound of water removed.
Falling-rate period is that drying period during which tho instantaneous drying rate continually decreases.
Fiber-saturation point is the moisture content of cellular ma terials (wood, etc.) at which the cell walls are completely satu rated while the cavities are liquid-free. It may Ire defined as the equilibrium moisture content as the humidity of the surround ing atmosphere approaches saturation.
Pinal moisture content is the percentage by weight of moisture remaining in the solid at the end of the drying operation.
Free moisture content is that liquid content which is remova ble at a given temperature and humidity. Free moisture may include both bound and unbound moisture.
DRYING TERMINOLOGY1
The generally accepted definitions of terms used in drying
technology follow: Adta&atfc drying occurs io a dryer when all of the sensible
heat given up By the air in cooling is used to evaporate water from the wet stock.
Batch drying is that type of drying operation in which the material is fed to and discharged from tne drying chamber in batches at definite intervals of time.
Bone-dry basic indicates the moisture content of a wet solid as pounds of water per pound of bone-dry solid. The advantage of using this basis is that the absolute amount of moisture loss is obtained simply by subtracting the moisture contents before and after drying. (See definition of Wet Basis.)
Bound moisture refers to liquid (held by a solid) which exerts a vapor pressure less than that of the pure liquid at the same temperature. Liquid may become bound by retention in capillaries, by solution in cell or fiber walls, by homogeneous solution throughout the solid, and by chemical or physical adsorption on solid surfaces. Bound moisture can be removed from a solid only under specific conditions of humidity in the external surroundings.
Capillary flaw refers to the flow of liquid through the inter stices and over the surface of 8 solid. It is caused by liquidsolid molecular attraction.
Fuel economy is the number of units of fuel (cubic feet of gas, pounds of steam, gallons of oil, etc.) required to remove 1 lb of water from the solid being dried.
Humidity denotes the amount of water vapor actually pres ent in a gas, and is generally expressed as weight of vapor, per unit weight of any gas-
Hygroscopic material is material that may contain bound moisture.
Initial moisture content is tbe percentage by weight of mois ture in the solid at tbe start of the drying operation.
Initial moisture distribution refers to tbe moisture distribu tion throughout a solid when drying begins.
Moisture gradient refers to the internal distribution of water in a solid at a given moment in the drying process, tbe nature of which depends on the characteristics ofthe solid involved.
Non-hygroscopic material is material that can contain no bound moisture.
Test drying time is tbe drying time of a relatively small and representative sample of tbe material which is dried in a labora-' tory dryer under conditions simulating commercial operation.
Tkrough-circulation drying is that method of drying in which the air flow is directed through a permeable bed of solids.
Unbound moisture in a hygroscopic material is that moisture in excess of tbe equilibrium moisture content corresponding to saturation humidity. Ail water in a non-bygroscopic material is unbound water.
Commercial dry basis expresses the moisture content of a product as pounds of water per pound of solid as it leaves the dryer, i.e., per pound of commercially dry solid.
Commercial drying time is the residence time of the material being dried in a commercial dryer.
Wet basis expresses the moisture in a material as a percentage of the weight of the wet solid. This basis is less satisfactory than
tbe dry-weight basis on which tbe percentage change ox mois
ture is constant for all moisture contents.
Constant-rate period is that drying period during which the rate of water removal per unit of drying surface is constant.
.Continuous drying is that type of drying operation in which the material to be dried is fed and discharged continuously to
MECHANISM OF DRYING1
When a solid dries, two fundamental processes are involved: (1) tiie transfer of heat-to evaporate the liquid, and (2) the
.
733