Document zQJm3gDjjJqEJaNGJjNVwdNJB

Air Conditioning and Automatic Heating Systems GILBARCO SERIES "F" AIR CONDITIONING UNITS HEAT - CLEAN - HUMIDIFY - CIRCULATE "Gilbarco" series "F" Air Conditioning Systems are efficient, dependable and un usually economical in operation. They are specially designed for oil fuel and develop a high degree of heating efficiency. The oversized radiator within the furnace, with its long, retarded gas travel insures a great amount of heat with economical fuel con sumption. The filtering and humidifying equipment is engineered according to advanced principles of this new science and the fan and motor are of sufficient capacity and dura bility to insure many years of efficient service. Model FBSS7100 Model FBRS7100 Filter-Washer-Blower Unit SPECIFICATIONS "GILBARCO" SERIES "F" AIR CONDITIONERS UNIT NOMBERS* B.T.U. Burner Burner! BLOWER DIMENSIONS (Incbe*) Smoke CHIMNEY Without Waxher With ,, Model Endoied C-F.M.t Fin Motor Filter* f A B C D E F Wuher Rejmer No. Mix. Di*m. H.P. No Site (In*.) Pipe Dt*m FINISH Sixc Heifht Ina. Ft. FBR27I0O 100,000 S2 No 1400 12 yi 2 16 x 2) 46 Di* 72 58 8* Cxlvuixed 8x8 50 FBS27100 100.000 &2 No 1400 12 F8O22120 FBOW22I2C 120.000 S2 PBS27150 FBSW27IJO 1)0,000 $2 FBD27200 FBOW2720C 200,000 S2 FBSJ22J0 FBSW122JO 2)0.000 JB6 FRStfjOO FBSWJ2300 WO,000 JB6 FBS})400 400.000 JB6 FBSJJ475 47),000 JB6 Ye* No f Ye* No f -No t No t No f 2000 2200 2)00 MOO 4000 woo ' 6000 12 16 16 18 18 21 ' 21 X 2 16 i 2) 4) 45 69 58 \ 8* Safe Green, 8 x 8 50 Ripple Enamel X 4 20 x 20 4) 51 11 Vj 61 8* Green Flintflex 8x8 W X 6 16 x 2) 50 5) x 61 26 14 * Gray Flintflex 8 x 10 50 X 6 16 x 2) 54 65 S2X 61 9* Green Flintflex 8 s 12 50 X 6 20x20 61 61 d 9? 6) 26 27 9' Gray Flintflex 10 x 12 W X 9 20x 20 61 61 J 97 6) 26 27 9' Gray Flintflex 10 12 30 X 12 16 x 20 61 67 97 n* 26 27 10* Gray Flintflex 12 x 12 >2 i 12 16 a 20 61 67 9? 26 27 10' Gray Flintflex 12 x 16 54 FBSM600 600,000 BStO No 55 120 91 - 12' Galvanized 16 16 36 FBSMflOO 800,000 bsio No SPECIAL 55 120 91 - 12' Galvanized 16 x 20 40 F indicicr* "F*` Serin B` Blower R* Round Cue S" Squire Cue D" Oe Luxe Cue Finish W* Washer fVestibule Burner Enclosure can be furnished at extra cost tC.F.M. foe Normal Static Pressure and Fan Speed {VitcoutType Renewable Filters 842 Air Conditioning Systems Henry Furnace & Foundry Co. 3471 East 49th Street Cleveland, Ohio MONCRIEF GAS FIRED AIR CONDITIONERS, OIL FIRED AIR CONDITIONERS AND COAL FIRED AIR CONDITIONERS MONCRIEF GAS FIRED AIR CON DITIONER. Approved by A merican Gas Associa tion. Burns mixed, arti ficial or na tural gas. MONCRIEF ARISTO CRAT OIL FIRED AIR CONDI TIONER. Specially de signed and constructed for oil burner service. Ac commodates any standard oil burner. Heats, cleans, humidifies and distributes the air through forced circulation. Re frigerating and dehumidifying equipment for summer cooling can be readily incor porated if desired. High efficiency in heating and low oper ating cost are achieved by means of special construction of burners and heating sections. See table below. The product of 38 years' experience. Made in three sizes: No. 200 delivers at register 118,465 Btu. No. 240 delivers at register 150,360 Btu. No. 300 delivers at register 200,475 Btu. Develops as high as 83 per cent efficiency at bonnet. Complete catalog and table of dimen sions and capacities furnished on request. MONCRIEF GAS FURNACES FOR AIR CONDITIONING SYSTEMS j Furnace No. I I 1 Type B and 1 [ Type C Width [ t/i Type C Less * Blower Length 8. Type C with Blower Length -g| | l Type B Height 8 Type C Heightj | Dia. Flue Pipe 1 Size Gas Line Heating Surface | Casing Free Area [ Velocity Thru j Furnace Btu Input Forced A ir Btu at Register C.F.M. Blower Size 1 No. of Filters Velocity Thru i Filters Gravity Btu at Register Gravity Pipe Area ze of 50 12 Js a? *3 C0 va. xJ HCQ 44 c 052 'Z 6 Z 48 1 3 100 19 44 52 85 5136 54 2 4 150 26 44 52 85 51*6 54 3 5 200 34 250 41 44- 52 88 5 Ufa 54 4 6 44 52 88 51% 54, 5 7 300 49 44 52 88 51*6 54 6 8 350 56 400 64 44 52 88 51J* 54 44 52 88 5136 54 78 89 450 71 44 500 78% 44 600 94% 44 52 88 5136 54 52 88 5)36 54 52 88 51% 54 9 10 10 10 12 10 CL X 5 o 2 % 2160 233 30,000 19,125 170 1 4320 376 215 60,000 42,750 560 110 % 2 105 38,250 281 1 6480 438 277 90,000 64,125 840 110 % 2 158 57,375 422 1 8640 584 277 120.000 85,500 1120 112 % 3 140 76,500 562 i% 10800 730 277 150,000 106,875 1400 114 V, 4 131 95,625 703 i% 12960 976 248 180,000 128,250 1680 212 M .4 158 114,750 844 i % 15120 1146 246 210,000 149,625 I960 212 M 5 147 133,875 984 i% 17280 1166 277 240,000 171,000 2240 214 'h 5 . 168 153,000 1124 i % 19440 1314 276 270,000 192,250 2520 214 'h 5 183 172,000 1265 i% 21600 1376 293 300,000 213,750 2800 214 'h 6 175 191,250 1406 i'a 25920 1678 288 360,000 256,500 3360 120 Vs 6 210 229,500 1688 Type B Furnace Casing has manifold exposed and is designed for gravity use. Blower and filters can be added as separate unit. Type C Furnace Casing has manifold enclosed and is designed for blower-filter use. Can be used' for gravity circulation if desired. Forced Air Btu Ratings are based on efficiencies of 75 per cent at bonnet and 95 per cent at register. Gravity Btu Ratings are based on efficiencies of 75 per cent at bonnet and 85 per cent at register. G-E.M. Capacities are based on 70 deg room temperature and 135 deg register temperature. Add 11 in. to overall height for 14 in. pitched top used with Type B Casing. See also Page 896 843