Document zQ7YQknmReVz4yEQRBvwng0NR

PLAINTIFF'S EXHIBIT DUP-2666 July 2, 1979 TO: ALL SUPERVISION - LIST "A" FROM: S F DIVISION VICTORIA PLANT ! CENTRAL SAFETY COMMITTEE MINUTES OF MEETING HELD WEDNESDAY, JUNE 13, 1979 Members Present: _ Members Absent A. D. Cyphers - Chairman 0. A. Sampson F. W. Farnsworth G. L. Brennan G. R. Ehrman J. V. Woodrick R. M. Robertson C. R. Steele L. F. Getz (for B. L. Sutphen) D. J. Logan E. J. Warwas W. T. Dodson B. W. Hardv D. G. Jentsch H. W. Anderson H. F. Charlton R. E. Keith H. W. Shahan M. A. Ervin W. P. Ledet B. W. Culpepper J. E. Borden J. M. Kavser W. T. Procter S. V. Hinson (Construction) C. E. Bunn B. L. Sutphen Visitors: M. D. Smith M. T. Ligon J. L. Chambard D. J. Bueker . P. V. Whitney - _ DU 007943 DUP 0801476 Victoria Plant Central Safety Committee Minutes of Meeting Held Wednesday, June 13 , 1979 jPage 2 I. The Monthly Safety and Housekeeping Audits and Injury Summary for May were reviewed. Bracing of unrestrained tubing which could move unexpectedly when used to blow down equipment should!be reviewed. The orientation of=blue flags on railroad derails do not always line up properly and can cause problems for trackmobile operators. Static electric bonding on some car spot rails has deteriorated and should bereviewed. 1 Storage of respiratory protective equipment is improving across the plant. ! A considerable number of violations of the lock and tag procedure were noted on one audit. The 'chairman expressed concern that we may need a general review of this pro cedure plant wide. I Several employees were noted wearing non'-approved glasses. The group was reminded that a slide/tapej program on identification of safety glasses is available from the safety office. ' Many items noted on one audit were the type things that should be observed and corrected by area! people. A high potential injury occurred when an;employee slipped in a change room aftershowering.Otherjplant areas should review their^facilities for similar potential. Congratulations to the following Housekeeping Award winners: 314 West Car Spot, CD-HC1 AreajMaintenance Shop, "J" Unit Reaction, Acids Power Water Treatment and Bldg. 516-517 T/F. ! II. Incident Reports i i Incident Reports Nos. 79-20 through 79-26, 79-28 through "9-32 and 79-34 were reviewed. The following additional- comments were made: 79-23 - The Relief Valve Subcommittee was asked to undertake an annual audit of the relief valve 'tickler system for compliance 'with required check frequencies. Also CSC audit groups should include! checks of an area's reliefvalve computer sheets Jas a part of the audit. I The chairman commented that these itjems should receive the most emphasis possible. : DUP 0801477 DU 007944 Victoria Plant Central Safety Committee Minutes of Meeting Held Wednesday, June 13, 1979 Page 5 III. IV. V. VI. 79-24 - The Chief Shift Supervisor will review recommendation No. 5. ! 79-25 - This incident report will be reissbed with a revised basic cause. 79-26 - D. J. Logan requested that the general problem of unexpected rail car movement be addressed. G. L. Brennan and Steve Nashatker will review and report back to the committee. ! 79-31 - R. E. Keith was asked toreview the problems associated with documenting on appropriate drawings the changes authorized by plant COD'S. j Safety Activities - W. T. Dodson ; Note - See attached #1 Evacuation Alarms - W. T. Dodson j Dodson presented a proposed revision to S F Procedure #1, Item 16, which would reserve and describe a specific alarm for use in areas where potential for largejscale explosions exist. This request was approved. S 5 F Procedure #1 will be reissued to reflect this change. | "Kirk Key" Interlock System Standard - P. V. Whitney Paul Whitney presented a proposed revision iio Plant Engineer ing Standard 8A Safety Relief Valves. This[proposal would allow the use of block valves under relief valves when equip ped with a lock system known as the Kirk-Ke^ System. A proposal to include a similar system for block valves in place of Daniels check valves was discussed|but delayed for future consideration. ! The standard was approved fordistribution, j Eye Wash Station Design - M. D. Smith A proposed revision to V.P. Standard 8E on Safety Showers 8 Eye Wash Stations was presented by M. D. Smith. These revisions include installing a hole in the eye wash piping to permit proper drainage, increasing height of eye wash nozzle from floor to 24" to 28" and drain hole in nozzle handle. i All area proprietors should review the revised V.P. Standard 8E when it is issued, and bring existing facilities up to these requirements by November 1, 19~9. 1 DUP 0801478 DU 007945 Victoria Plant " i Central Safety Committee -- ' Minutes of Meeting Held Wednesday, June 15, 1979jPage 4 VII. Hazard Alert on Confined Spaces j VIII. Attached is a release from the Wilmington S Sj F Division on OSHA's concern for hazards associated with working in con fined spaces (vessel entry). I Hard Hat Goggle Clips j Effective immediately the practice of installing snaps on hard hats and coverall goggles to provide a iconvenient method for carrying same will be discontinued. The S F Division wilLprovide, on a replacement basis, a plastic clip which attaches to the MSA-V guard hard Aats which will secure the coverall goggles. | As new goggles are secured from stores, a ha't clip should be obtained from S F. We do not plan a wholesale change out of hard hats or goggles. j IV. Key Safety Data j The Key Safety Data indicator showed an improved trend for the month of May, dropping from 11.35 ip April to 6.31 in May. ; A. D. Cyphers indicated that all involved had done a good job in getting the attention of the plant on the unfavorable safety trends noted in previous months. Our job now is to continue to keep this high degree of safety interest and awareness at a peak JEB/kms DUP 0801479 DU 007946