Document zOLmyXxREBqXk46Jd906rdbm
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGION 5
77 WEST JACKSON BOULEVARD CHICAGO, ILLINOIS 60604
SUBJECT: FROM: THRU: TO:
CLEAN AIR ACT INSPECTION REPORT Evraz, Denver, Colorado
Natalie Schulz, Environmental Engineer AECAB (MN/OH)
Brian Dickens, Section Supervisor AECAB (MN/OH)
File
BASIC INFORMATION
Facility Name: Evraz
Facility Location: 5601 York Street, Denver, Colorado 80216
Date of Inspection: June 21, 2022
EPA Inspector(s): 1. Natalie Schulz, Environmental Engineer 2. Brianna Fenzl, Environmental Engineer 3. Katelyn Bergl, Air Enforcement and Compliance Assurance Branch, Region 8
Other Attendees: 1. Gerardo "Chito" Orozco, General Manager 2. Ricardo Marioni, Operations Manager
Contact Email Address: gerardo.orozco@evrazna.com
Purpose of Inspection: Safe disposal of appliances regulation
Facility Type: Scrap metal recycling yard
Regulations Central to Inspection: 40 C.F.R. Part 82, Subpart F: Protection of Stratospheric Ozone, Recycling and Emissions Reductions
Arrival Time: 9:55 a.m. Departure Time: 11:15 a.m.
Inspection Type: Unannounced Inspection Announced Inspection
OPENING CONFERENCE
Presented Credentials Stated authority and purpose of inspection Provided Small Business Resource Information Sheet See document attached to email delivering this report Small Business Resource Information Sheet not provided. Provided CBI warning to facility
The following information was obtained verbally from Gerardo Orozco and Ricardo Marioni unless otherwise noted.
Process Description: Evraz accepts small appliances for recycling from the public and commercial suppliers. It does not perform refrigerant recovery. The facility has a third-party service perform refrigerant recovery. It only accepts car bodies from other scrap yards; it does not perform car processing on-site.
Staff Interview: The facility performed refrigerant recovery on-site until 2019. Since 2019, the facility has had a third-party perform refrigerant recovery on intact small appliances from the general public. The facility has a verification statement for the general public to sign that included lines for the person who performed the recovery and signature. Industrial suppliers have a contract with the facility.
TOUR INFORMATION
EPA Tour of the Facility: Yes
Data Collected and Observations: Inspectors reviewed the facility's CFC evacuation log from when the facility performed refrigerant recovery; the log had its last entry in 2019. Inspectors observed examples of verification statements, contracts, and third-party refrigerant recovery receipts.
Inspectors observed scrap piles of scrap metal from the general public. Inspectors observed the staging area for small appliances that have refrigerant recovery performed by a third-party. Inspectors observed the refrigerant recovery equipment that the facility used when the facility
Page 2 of 4
performed refrigerant recovery on-site. Inspectors observed scrap piles from industrial suppliers. Inspectors observed appliances in the industrial supplier scrap piles; inspectors were able to examine one appliance from the pile closely and did not observe evidence of proper recovery.
Photos and/or Videos: were taken during the inspection.
Field Measurements: were not taken during this inspection.
RECORDS REVIEW
1. CFC Evacuation Log 2. CFC/HCFC Policy Certification for Material Receipts/Scale Tickets (Verification
Statement) 3. Scrap Supplier - EVRAZ North America - Denver Agreement (Industrial Supplier
Contract)
CLOSING CONFERENCE
Provided U.S. EPA point of contact to the facility
Concerns: Inspectors reminded the facility that when small appliances are handled roughly it increases the chance of the refrigerant leaking from the small appliance. Inspectors also suggested that the language of the signage be modified to accurately reflect the facility's refrigerant policy; the facility does accept small appliances containing refrigerant, but the signage says the facility does not.
DIGITAL SIGNATURES
NATALIE
Digitally signed by NATALIE SCHULZ
SCHULZ
Date: 2022.08.18 22:04:01 -05'00'
Report Author: _________________________________
Section Supervisor:
Brian
Digitally signed by Brian Dickens
__D_i_c_k_e_n_s______0_7:_40_:4_4 _-0_5'0_0'_____________ Date: 2022.08.19
Page 3 of 4
Facility Name: Evraz Facility Location: 5601 York Street, Denver, CO Date of Inspection: June 21, 2022 APPENDICES AND ATTACHMENTS 1. Appendix A: Digital Image Log
Page 4 of 4
Facility Name: Evraz Facility Location: 5601 York Street, Denver, CO Date of Inspection: June 21, 2022
APPENDIX A: DIGITAL IMAGE LOG
1. Inspector Name: Brianna Fenzl
2. Archival Record Location: C:\Users\nschulz\Environmental Protection Agency (EPA)\Fenzl, Brianna - Scrapyards - Denver Area\Inspection Photos\6-21 Brianna and Natalie S
Image Number
1
File Name IMG_0058
Date and Time (incl. Time zone and DST) 6/21/2022 10:06 a.m.
Description of Image CFC Evacuation Log
IMG_0059
6/21/2022
Peddler scrap pile and radiator dumpster
2
IMG_0060
6/21/2022
Peddler scrap pile and radiator dumpster
3
IMG_0061
6/21/2022
Recovered small appliance area
4
IMG_0062
6/21/2022
Peddler scrap pile
5
IMG_0063
6/21/2022
Contract scrap pile
6
IMG_0064
6/21/2022
Contractor scrap pile
7
IMG_0065
6/21/2022
Refrigerator in contractor scrap pile
8
IMG_0066
6/21/2022
Signage
9
IMG_0067
6/21/2022
CFC/HCFC Policy Certification for Material
10
Receipts/Scale Tickets
IMG_0068
6/21/2022
Scrap Supplier - Evraz North America - Denver
11
Agreement
Appendices Page 1 of 1