Document zNMnxyM1ZMZzeo7Dqq8DRzOg
0
t
1
Inter Office
Electrical and Electronics Division ^psiianti Plant
October 16, 2980
TO: D. A. Gray P. E. Toth 1/
Via:
D. B. Vaughan
cc: R. J. Womac G. K. Nichols D. J. Stacbelskl
Prom:
0. H. Wolcott
Subject: Michigan Industrial Occupational Safety
and Health Administration Inspection
Pursuant to the Industrial Relations Manual, Volume III, Section C, Topic 775, the following information la submitted:
Plant: Ypsilanti Plant - Electrical and Electronics Division.
Governmental Safety or Health Agency Represented: Michigan Department of
Public Health, Bureau of Environmental and Occupational Health.
Inspector's Name: Henry J. PyzlR
Inspector'8 Title: Engineer, Division of Occupational Health
Date of Visit: October 16, 1980
Purpose of Visit: To investigate an employe complaint concerning alleged air contaminents at the chrome plating operation In Department W91 - Rod Machining, Bay M-20 in Building #2A.
Total Hours in Plant: 3 Hours
Were Citations issued immediately: No.
Did the Inspector indicate that Citations would be issued?
The Inspector stated that the results of hiB air sampling would be
reviewed. In the event that the exposure limits for chromic acid mist were approached or exceeded, further sampling would be conducted to dete^pine if the plant is in violation of State Standards.
Vhat operations or equipment, if any, were or might be cited?
Two employes assigned to the Chrome Plating Operation were monitored.
I *0C7 Cl2
SCF-FORD-2153
PRODUCED BY FORD
-2-
Vhat violations, If any, vere posted In the area? None*
Vhat recommendations vere made? None.
What corrective actions will he taken? None at this tine.
Vere Instruments used to monitor the environment?
Two samples vere taken for chromic acid mist. The following
Instruments vere used:
Sample #1:
Mine Safety Appliance (MSA) personal sampling pump #6751*3 vlth
built-in rotameter at 1*7 liters/minute.
Vinyl Metric el Filter #4285
Time: 9:45 A.M. to 11:45 A.M., 2 hours
Operator
'
Sample #2:
MSA Pump #67539 vlth bullt-ln rotameter at 1*7 liters/minute.
Vinyl Metricel Filter #4266 Time: 9:90 A.M. to 11:09 A.M., 1 hour, 19 minutes Set-up
In addition, the Inspector sampled for Carbon Monoxide since the employe complalntant alleged that the air contaminent6 caused his headaches. He used:
MSA hand pump
MSA colorimetric tube for CO 3 strokes - 10 ppm reading
Names and titles of persons accompanying the Inspector:
D. E. Roth - Safety Engineer J. T. Tindall - Health and Safety Hep. U.A.V., Local 849 P. J. Zande - Unit Supv., Safety, Security and Fire