Document z3oMEVobYNqX00pdaR8MVX0m
354
Heating Systems
COLUMBIA Boiler Company of Pottstown
Pottstown, Pa. Makers of steel power and heating boilers COLUMBIA'S H.R.T.* OIL OR GAS FIRED BOILER & STEAM GENERATOR
ASHE CODE CONSTRUCTED
Available for pressures of 15 to 250 psi A complete, automatic power plant wherever steam is used for processing
Columbia b.r.t. boilers are fully automatic, compact, complete steam generators. Available in sizes ranging from 2 to 100 horsepower. Designed for firing with gas, light or heavy oils. A special Columbia unit makes pos sible the inter-changeable use of gas or oil.
Overfiring Permitted: Conservative ratings plus large combustion volume permit overfiring. This frequently eliminates the need for additional boiler capacity, al lows for plant expansion.
High Steam Output: Columbia's h.r.t. boilers have an unusually large heating surface to produce more steam at higher efficiencies. More heat is converted into steam since it is proportioned to make maximum use of hot gases of combustion for the production of steam.
Horizontal Design for longer life: The complete sub mersion of tubes protects them from water line cor rosion.
Dry Steam Assured: Large steam space and greater liberation area virtually eliminate waste producing water carryover.
Over-AU Efficiency: Factory installed, specially de signed combustion chamber provides rapid heating re fractory surfaces for peak combustion efficiency. In sulation, 7 inches thick in the combustion chamber proper, and 4 inches thick in the gas passage, keeps heat loss at a minimum. Special refractory brick heats up to great intensity to complete the combustion of previously unignited fuel particles. This complete com bustion not only increases efficiency but makes for clean combustion. Soot accumulation on heating sur faces is minimized. Boiler tubes require less cleaning.
Safety Assured: Two pass updraft design lowers direct loss and reduces possibility of furnace pressure, pulsation or excessive combustion noises.
Accessibility and easy Maintenance: Simplified con struction provides easy front and back access to the single bank o! tubes. Entire unit can be gotten to for inspection of boiler and chamber by removing the covers.
SPECIFICATIONS AND DATA COLUMBIA HRT BOILERS FOR GAS, LIGHT OIL OR DUAL FUEL
HORIZONTAL RETURN TUBULAR TYPE
BOILER SIZE
6 8 10 15 20 30 40 60 80 100
Ho Rating......................
6 8 10 15 20 30 40
60 80 100
58 69 69 84 84 100 100
102 124 124
Width O.A.....................
29 33 33 39 39 45
45
52 58 58
Height O.A....................
44
50
50
64
64
68H
8H
. 80
96
96
30 56 72 92 120 200 290
415 548 668
2.00 3.00 3.5 5.00 7.00 10.00 12.00 18.00 24.00 30.00
280,000 400.000 490,000 700,000 900,000 1,400,00C 1,700, Q0C 2,600.00C 3,300,00C 4,200,000
Approximate Output. . .Btu per hr 200,000 300,000 350,000 500,000 700,000 1,000,000 1,200,000 1,800,000 2,600,000 3,400,000
Horizontal return tubular type boiler.
COLUMBIA Boiler Company of Pottstown
Pottstown, Pa.
Makers of steel power and heating boilers
STEEL, TUBELESS, OIL-FIRED, WATER TUBE GAS-FIRED AND COAL-FIRED HEATING UNITS
355
ASME CODE CONSTRUCTED SBI RATED A.G.A. APPROVED
Available with highly efficient, custom_engineered gas or oil burners. Columbia steel boilers, gas or oil fired, have self contained large copper instantaneous tank less coils, supplying a continuous flow of year 'round domestic hot water. .
Maximum operating efficiencies assured by the bal anced design of the boiler and burner; by the arrange ment of the baffles which force the hot gases to travel four or five times the full length of the boiler.
One piece electric welded construction: Columbia offers a heating unit with full electric welded construc tion of heavy copper bearing steel, to assure lower heat ing cost and longer operating life.
Quiet operation: Ample combustion space, the insula tion and heavy steel jacket completely eliminate objectional noise.
Dual Firing: Columbia oil heating units may be easily converted for efficient gas firing.
Oil and gas burners for Columbia Boilers are designed and manufactured by Columbia to insure maximum perforraance of boiler-burnerjmits and to provide undivided responsibility.
MODEL NO.
L-I6
L-18
L-20
L-22
L-24
*L<30
L-32
*L-40
Ratine*--Oil Fired
Input--Gals per Hr....... SBl Net Rating
1.00 1.20 1.35 1.75 2.25 3.00 4.00 7.00
Sq Ft Forced Water
Sq Ft Gravity Water So Ft Steam .
Btu per hr Forced Water Btu per hr Gravity WAter Btu per hr Steam ..
580
510 320
87.000 77.000
77,000
720 640 400
108,000 96,000
96,000
990 880 550
149.000 182.000
132,000
1260 1120
700 189.000
168.000 168,000
1620 1440 900
243.000
216.000 216,000
1980 1760
1100 297.000 264.000 264,000
2700 2400
1500
405.000 360.000 360,000
4000 3500 2200 600,000 530,000
530,000
* Constructed Water Tube Only
" "-----------------------------------------------
' cHtFS^Jp^nG'A' a?d TM Appr2v?f f?r outputs from 72,000 to 172,000 Btu's per hour,
coal Hand Ftred Conversion Unite available in sues L-18, L-22 and L-30
^
COLUMBIA BASEBOARD RADIATION
Suspended Element--no noise I Tension Fastening--no rattling! Low Angle Heat--no drafts! Pre-Punched Holes--fast installation!