MINUTES of the TECHNICAL U RESEARCH COMMITTEE MEETING NATIONAL INSULATION MANUFACTURERS ASSOCIATION Chicago, HI. March 8, 1962 Molded Section Chairman H. P. Hoope3 called the meeting to order at 9:30 A. M. with the following in attendance: H. P. Hoopes. Chairman \V, P, Sinclair V. L. Miller D. 3. Wiagerter Utley Smith E. F. CttF Jr. V/. R, Seipt A. Kevlia R* C. Parlatt Fibreboard Paper Products Corp. Union Asbestos St Rubber Co. Pittsburgh Coming Corp. JohnsMasxville Sales Corp. Baldwin-Ehret-Hill, Inc. Keasbey & Mattison Co. Keasbey Sc Mattison Co. Owens-Coming Fiberglas Corp. NIMA DEFINITIONS Comments have been received on the 11/28/61 issue of Definitions. These comments were resolved in the following manner: Composition Item 1. Change title from "Mineral Fiber" to Mineral Fibers", Item 7, Should be changed to read "Mineral Fiber Thermal Insula tion is composed principally of fibers manufactured from mineral substances such as rock, slag or glass with or without heat resistant inorganic binder (a)." This, then, conforms with Item 3 on Di&tomaccous Silica, since both Item 3 and Item 7 are generic terms and apply to loose products aa well as to rigid materials. Item 5, Has been revised to read "Cellular glass thermal insulation is composed of glass processed by fusion, to form a rigid homogeneous mass of hermetically sealed cells. " Item 8. Has been revised to read "Cellular plastic tthdrmal insula tion is composed of organic materials processed to form a homogeneous mass of cells." 2 Forma Item 2. Has been revised to read "Block or board insulation is rigid thermal insulation preformed in rectangular unit3 to fit flat surfaces or curved surfaces of diameters above 33 inches. " Item 8. Has been revised to read "Felt insulation is semi-rigid or flexible thermal insulation, normally furnished in flat sheets composed of mineral fibers with or without binder. RECOMMENDED PRACTICE FOR INSULATION O. D. *S FOR TUBES After considerable discussion an. agreement on tubing sizes could not be reached. Since we do already have a Table cSBrocsiceelroa Pipe, why then could these sires not be used for tubing and avoid a second table. Therefore, Jack Barnhart will poll the members by sending them the latest ASTM Table for IPS dated January 31, 1961 requesting them to either approve or to submit their reasons as to why any or all of these sizes are not acceptable for tubing. These are to be returned back to Jack within 30 days. He will then summarise the results and circulate them to the members well before the next T i R meeting. TRUENESS AND SQUARENESS OF BLOCK AND PEPS COVERING "Within about a month* Paul Losse will take photographs cf various ways in which pipe covering can be out a trueness and squareness. These pictures will serve as a basis to help define what is meant by trueness and squareness before a method for measuring these qualities can be drawn up. Ed Davis submitted a tentative method of test for truenessand squareness cf block insulation. This was reviewed and the follow ing changes were recommended. In Paragraph 3(a)2, change to r%ad "Place the straight edge on edge on both diagonals, comer to corner." In the figures 2(a) and 2(b), instead of a triangle a carpenter's square should be illustrated. COMMENTS FROM LETTER 3ALLOT OF ASTM C-39I AMOSITS ASBESTOS THERMAL INSULATION FORPIPSS Three comments were recievod to the paragraph on Composition 3a. These comments seta all resolved with the following addition at the end cf this paragraph "'With heat resistant inorganic binderfs) and with or without filler. * One other comment received from Armstrong Cork Co. was editorial in nature for which NIMA have no further comments. 3 SPECIFICATION FOR U.\g\ATSD CALCIUM SILICATES FOR PIPE <K%M ZEBRA) Based upon comments received from the first draft of thi3 proposed soecificaiion, Mr. Strcepy was to have prepared a redraft before submitting to 3-1 for Letter Ballot* Mr* Streepy advised that he has not had the opportunity to prepare such redraft and will advise NIMA when it is ready. PROPOSED 85% MAGNESIA BLOCK AND PIPE COVERING ASTM SPECIFICATION Jack Barnhart had combined the two existing, separate specifications into one, and submitted it to Committee Cl6 for balloting. There were 89 returns, 75 affirmative and 14 not voting. Mo negative ballots were received. Some ballots returned comments. These were reviewed and they wore all found to be of an editorial nature* Therefore, NIMA have no further comments to make and recommend that Committee C-16 nandle them, in the usual manner. MILITARY SPECIFICATION MIL-I-2S19C 23, Oct. 1, 1961 Copies of this relatively new specification were distributed* It had been issued after the NIMA had submitted recommendations for certain changes to be made to a previews interim specification. Jack Barnhart will send out to the members differences between our recommendations and the now specification. Each member is requested to study these differences, and then submit comments to Jack Barnhart within a month. Jack wiDcsummaries these comments and send copies to all members before the next meeting. ADJOURNMENT There being no further business, the meeting was adjourned at 3:00 P, M. Respectfully submitted W* R* Seipt Secretary pro tem