Document yrzJZm7VjYrwygozna9Gdq3QE

Heating Systems on"0* Simplex Oil Heating Corp. 11 Park Place New York 7, N. Y. 1910 Domestic, Industrial, and Custom Designed Oil Burning Systems SIMPLEX PNEUMATIC TURBINE TYPE BURNER 4 Sizes--Ratings up to 400 gph. Burns any grade of fuel oil. Manual, Semi or Fully Automatic. The SIMPLEX Turbine Type Burner is also available in combination for burn ing either gas or oil. A 100 per cent gas burner or a 100 per cent oil burner. The change from one fuel to the other can be made in less than 5 minutes time. SIMPLEX Oil Burning Systems have been listed as standard by the National Board of Fire Insurance Underwriter's Laboratories, Chicago; approved by the Board of Standards and Appeals of New York City; approved by the Department of State Police, State of Connecticut, and conform to local governmental and insurance requirements everywhere. SIMPLEX HORIZONTAL ROTARY TYPE BURNER 4 Sizes--Ratings up to 90 gph. Furnished only with standard motors of nationally known manufacturers. Burns any grade of fuel oil. Manual, Semi or Fully Auto matic. SIZES AND CAPACITIES--TYPE H.E.G.H., TYPE H.E.G., TYPE H. Burner No. (for all types) ___________ 23 5 8 Motor HP................................................................... Maximum Capacity, gallons per hour (Approx.). . . H P Rating (Approx.).............................................. .. Sq Ft Steam Radiation--boiler output (approx.)... (Based on 400 Sq Ft per Gal.) U )4 M 2 10 25 40 90 30 75 120 300 4,000 10,000 16,000 36,000 1324 Heating Systems Burners, oa Williams Oil-O-Matic Division WILLIAMS OltOMATlCsYSTEMS EUREKA WILLIAMS CORPORATION. BLOOMINGTON. ILLINOIS Manufacturers of Automatic Fuel Oil Burners and Complete Heating Units for Steam, Hot Water, Warm Air and Radiant Heat. OIL BURNERS Williams Oil-O-Matic Low Pressure burners: Easily installed in any type of heating plant. Use any domestic fuel oil, including the new catalytic oils. New "Sealed Thrift Unit" on Model FiftyTen is factory sealed. Replacement units installed in minutes. WINTER AIR CONDITIONERS New Utility Models: Utility Model 1 (vertical-in-line con struction) for basement, utility room or closet install ation. Requires less than 4sq ft of floor space. Utility Model 1 is entirely suspended from the ceiling or under the floor. Both units factory-wired, fac tory-assembled. Both equip ped with Model Fifty-Ten Oil-O-Matic Low Pressure Burner. Capacity of each unit: 70,000 Btu. Williams High Pressure burners are precision-built for those who want high quality at minimum first cost. Oil Burners Model FiftyTen K-4.5 K-7 A HP-7 Oil Capacity Gals, per Hour Min. Max. .6 3.0 2.50 4.5 4.00 7.00 1.00 3. 3.50 7.00 Motor Hp Rpm >6 3450 1725 M 1725 `/6 1725 1725 Atomizing 1 to 3 lbs lbs 3 lbs 100 lbs 100 lbs Utility Models 1 & IS Model 70 Streamlined Package Units: Complete winter- air-conditioning furnace- burner units. Dual radia tion and counterflow construction. Capacities: 70,000, 100,000 and 150,000 Btu. Oil-O-Matic Winter Air Conditioners NEW STEEL BOILER-BURNER UNIT All-steel boiler-burner unit for 5- and6-room insulatedtype homes; a new develop ment! Only 22f in. by 28f in. - by 43^ in. high! Domestic water coils up to 180 gph. Water base; flueless con struction. Lightest waterbacked metal 1 in. Ca pacity: 320 sq ft water, net. Oil-O-Matic Boiler--Burner Units STEEL Model 300W Sq Ft Net Net Load Output Steam Water Btu/hr -- 320 48.000 Gross Output Btu/hr Oil Input (gph) .70 CAST IRON C-3 (S or W) C-4 (S or W) C-5 (S or W) C-6 (S .or W) 300 480 72,000 111,000 1.05 450 720 108,000 164,000 1.55 600 960 144,000 216,000 2.05 750 1200 180,000 268,000 2.50 Model BTU at Bonnet C.F.M. (a) 3/8" S.P. Oil Input G.P.H. Utility 1 and r-s 70 I0A 15A 70.000 70,000 100,000 150,000 900 900 1300 1800 .70 .70 1.00 1.50 Filters Sq. In. 600 600 1000 1920 Blower Motor H hp K hp Xhp NEW CAST-IRON BOILER-BURNER UNITS Four sizes for hot water heat and four for steam. Equipped with Model Fifty-Ten Low Pres sure burner or Model A Hi-Pressure burner. Built-in domestic hot water coils to 240 gph. All metal jacket, bonded glass wall insu- Model C-s Iation. Water base construction. Special high.insulating factory-designed combus tion chamber. Boiler tappiags for all con trol systems. Capacities: from 310 to 690 sq ft of steam radiation; 500 to 1.100 sq ft of hot water. 1325