Document yrwkRbMpGy7v005VLVEEpKaRd
National Radiator Corporation
Boilers and Radiators
National Imperial Sectional Boilers
The spacious fire box provides large fuel capacity which allows maximum time be tween attention periods, and makes it possible to carry an economical and effective fire.
After leaving the combustion chamber the hot gases travel twice the length of the boiler before discharging into the stack.
Special grates can be fur nished to burn the smaller sizes of fuel.
Boiler . Steam Number Rating
Water Rating
Grate
Area Sq.Ft.
Length of Sections'
Only In.
Length of Sections and Smoke Box
In.
of Outlets
Sizes in In.
32lSerio--lHeight of Waier Line, S3* .
532
2900
4650
632
3600
5800
, 732
4300
6950
832
5000
8100
932
5700
9250
47 Scries--lHeight of Wa '.cr Line. >/" .
642
5200
6300
742
6200
9900
842
7200
11500
942 8200 13100
1042
9200 . 14700
1142
10200
16300
1242
11200
17900
1342
12200
19500
1442
13000
20800
1542
13800
22100
1642
14600
23400
Height of Top Outlet, W/S. Width of Boiler. 41
7.32
3714
493/4
1-5*
9.10
45%
58
2-5*
10.87
53%
661/4
2-5*
12.65
62
741/4
2-5*
14.42
70%
B2i/a
3-5*
Height of lop Outlet, 69Width oj Boiler, 571/3
12.03
45i/2
571/2
2-5*
14.38
53Vi
653/4
2-5*
16.73
62
74
3-5*
19.08
70i/4
821/,
3-5*
21.43
78%
903/5
3-5*
23.77
86%
99 .
3-5*
26.12f 95
107'/,
4-5*
28.47f
30.82t 33.17f
103%
1W8
iHG
132
4-5* 4-5* 4-5*.
35.52f 128
140%
4-5*
Chimney
Area In.
Height Ft.
14x14 15x15 16x16 16x16 18x18
16x16 18x18 18x18 20x20 20x20 21x21 22x22 22x22 23x23 23x23 24x24
40 40 40 50 50
50 50 55 55 60 60 65 70 75 75 80
"Boiler Covering
Sq. Ft. Surface
42 51 60 69 78
56 66 76 86 96 106 116 126 136 146 156
"Square feet of exterior boiler surface. Approximate number of pounds of boiler covering per section--23 series, 50 lb.; 32 series, 60 lb.; 42 series, 67 lb.
fMaiimum grate area which can be furnished. Unless otherwise ordered these sizes are shipped with 10 grate bars having a grate area of 23.77 sq. ft.
Boiler - Number
Steam Rating
684 784 884
984 1084 1184 1284
-
11200 13200 15200 17200 19200 21200 23200
National Duplex Sectional Boilers
Water Rating
17900 2M00 24300 27500 30700 33900 37100
' Crate Area
Sq.Ft.
24.06 28.76 33.46 38.16 38.16 42.86 42.86
Length of Sections
Only In.
Length of Sections and Smoke Box
In. v
Number of Outlets
Sizes in In. .
45'/, 53%
62
70% 78% 86%
95
621/* 70% 79 871/,
95'/2 103% 112
1-8* 1-8" 1-8* 1-8* 1-8* 1-8* 1-8*
Chimney
Area In.
22x22 23x23 24x24 25x25 26x26 27*27 27x27
Height Ft.
65 65 70 75 60 80 85.
"Boiler ' Covering
Sq.Ft. Surface
76 90 104 118 132 146 160
Height Water Line, 57 in. Height to Center of Header Outlet, 81 in. Width of Boiler, 115M in. Regularly furnished with cast iron header, but can be furnished without header when so ordered. "Square feet of exterior boiler surface. Approximate number of pounds of boiler covering per'eectiou, 94 lb.
552
Newport Boiler Company
General Offices: 529 S. Franklin St., Chicago
Boilers
This boiler cuts fuel bills from 30 to 50 per cent burning No. 1 Buckwheat coa
"Newport"--alone, provides these Heater essentials:
Convenience Coaling only necessary from once a day to once a week, depending upon the weather. It is therefore the Home Owner's choice.
PrAnnmv "Newport" combustion is complete, conforming to all the laws of science.. Saves from $5 to $7 per ton, burning No. 1 Buckwheat coal.
Tprovided by the never .varying thickness of the fuel bed, that
%ji til
txt supplies heat for every nook and comer, automatically controlled.
Adapta bility the patented, adjustable throat, which is water cooled, insures maximum efficiencies, burning all sizes and kinds of coal, coke or oil.
NEWPORT COAL BURNING BOILERS
Boiler Number Steam
Rating Square
"Maximum Direct
Radiation
Load
Boiler Number Water
Rating Square-
Feet
"Maximum Direct
Radiation Load
Length Overall
STEAM
S-4 ' S-5 S-6
S-7 S-8 S-55 S-66 S-77 S-88 S-99 S-10I0 S-III1
594 750 907 1063 1219 1375 1688 2000 2313 2625 2938 3250
340 430 518 607 6% 786
965 1143 1322 1500 1679 1858
W-4 W-5 W-6 W-7 W-8 W-55 W-66 W-77 W-88 W-99
W-1010 W-1111
WATER
1000 1250 1500 1750 2000 2282 2782 3313 38(3 4313 4813 5313
'
572 714 857 1000 1143 1304 1590 1893 2179 2464 2749 3035
301/4* 36%'
42y4'
49*
55%' 44*
501/4* 56%' 62>4* 69*
751/4'
81%'
width
Overall
32' 32* 32* 32* 32* 56* 56* 56* 56* 56* . 56* 56*
Chimney Flue
Size Inches
8x 12 8x 12 8x 12 12x12 12x12 12x12 12x16 12 x 16 16 x 16 16x16 18x18 18x18
Height Feet
35 35 40 40 45 40 45 45 50 50 50 55
NEWPORT OIL BURNING BOILERS
O-S-4
594
340 O-W-4
1000
572 30/4' 32*
8x12
O-S-5
750
430 O-W-5
1250
714 36i/2* 32*
8x 12
O-S-6
907
518 O-W-6
1500
857 42*4* 32*
8x12
OnS-7
1063
607 O-W-7
1750
1000
49*
32* 12 x 12
O-S-8
1219
696 O-W-8 2000 1143 551/4* 32* 12x12
O-S-55
1375
786 O-W-55
2282
1304
44'
56* 12x12
O-S-66
1688
965 O-W-66
2782
1590
501/4*
56*
12x16
O-S-77
2000
1143 O-W-77
3313
1693
56'A*
56*
12x16
O-S-88
2313
1322 O-W-88
3813
2179
62*4*
56*
O-S-99
2625
1500 O-W-99
4313
2464
69*
56* 16x16
oO--Ss--1t0n1t0
2938 3250
1679 1858
oO--Ww--IOmIOi
4813 5313
2749 3035
75'/4' 81%'
56* 56*
18x18 18x18
35 35 40 40 45 40 45
45 50 50 50 55
"The " Maximum Direct Radiation Load" is the maximum actual amount of square feet of cast iron enlnmn radiation
or its equivalent that we recommend be attached to boiler. This amount provides a safety factor of 75 per oent, bring ample
for average conditions, to take care of the load imposed by mains, risers, etc., but does not provide an allowance for thebeabng
of water for domestic use, or any extra load where attached radiation will condense more than 0.25 04) lb. of steam, per
square foot per hour.
The water line on all Steam Boilers is 403$ in.
Height overall Coal Boilers 62 in.
Oil Boilers 48in.
553
x