that can be likened to Dr. Roentgen's ear ly attempts. In addition, the early models required between two and four minutes to render an image of each slice. This time has been considerably reduced and a bet ter image can now be obtained in two to five seconds. However, it must be remem bered that a considerable amount of time is usually expended positioning the pa-
"The scanner is not a diagnostic panacea and it must be used with
intelligence and restraint."
the market. Most patients undergo exam*, (nation only once; however, repeated ex aminations of the brain over a prolonged period of time can result in damage to the cornea, and it is the responsibility of the radiologists to see that this sort of trauma does not occur. Future development env tails reduction of the amount of radiation while preserving the quality of the image.
In sum, the criteria for formulating policy regarding CT scans are diagnostic reliability and superiority over other tech niques, time and cost considerations, and the safety and well-being of the patient. .
Governmental Regulation
tients on the table and injecting them with contrast material. Thus, even with the improved scanning time, studies may take 10 to 20 minutes for each patient, as many examinations require evaluation before and after the injection of contrast materi al. In addition, reproduction of the image on the screen may take an appreciable amount of time, and this in itself can re duce the daily quota of patients.
Another important factor is patient cost. Though fees charged for CT scan ning have been reduced during the last year, the cost to the patient--$100 to $400--remains high, relative to most other diagnostic tests. Some centers have separate charges for examinations with and without the use of contrast material, and patients must pay the double rate if both examinations are performed.
The amount of radiation delivered during a CT scan is an aspect which has provoked little comment. The older, slow er units deliver a dose of approximately two rads per slice, which is in the range of acceptability, but the newer models de liver a significantly larger amount of radi ation to the patient. In an age in which we are all sensitive to the amount of radiation exposure patients receive, we must make a hard appraisal of our present practices.. It would seem appropriate for medical physics departments to play a dominant role in this matter and compare the doses incurred by various machines currently on
In reality, CT policy is affected by devel opments that have little to . do with real needs.
Distribution of CT scanners is a major problem currently facing the medical com munity. The scanner unfortunately made: its appearance just at a time, when rising medical costs had caught the attention of federal agencies; the scanner itself was blamed for the increase in health care costs, though this assertion actually has no merit. The' federal government none-
"In an age in which we are all sensitive to the amount of radiation
exposure patients receive, we must make a hard appraisal of our present practices."
theless felt compelled to involve itself in CT planning policy, and the certificate of need concept, making all equipment purchases over $100,000 subject to federal approval, grew out of these economic concerns. To further complicate the situ ation, recent HEW recommendations sug gest that before a hospital can acquire a CT scan, neighboring units must conduct 4,000 examinations per year. Again, this; is not founded upon a realistic assessment,' as no CT unit can accomodate this many examinations. While the basic intent of
3001 <)'{< J
;a-a cancer journal for clinicians
these federal regulations is to prevent du>; plication of service? and ensure adequate backup in terms of facilities and person nel, this sort of legislated distribution ap plies more logically to treatment modali ties than to diagnostic techniques--and the scanner is primarily a diagnostic tool. The unfortunate result of this govern mental intereferenge is a battle over the control of scanning equipment and, par ticularly where head units are concerned, a source of conflict between radiologists and neurologists. Another potential prob lem related to government involvement is the complete loss of quality control--for example, making CT units available to untrained practitioners and encouraging mistakes and unnecessary examinations by inciting centers to perform more scans than good policy Would dictate. Further, government-imposed restrictions on pur chases will depress the market and obviate research incentives among manufacturers.
Hospital Expanse
being used, and a physician is required
to monitor the tests and inject contrast
material.
Spacerequirements--these are cqnsid-
erable, as the equipment is bulky. "
Depredation of the equipment.
Utilities--the system houses its own air
conditioner.
Servicing costs.
,
Charges for contrast material, syringes
and other supplies.
The impulse at many centers is to max
imally utilize such a marvelous and costly
piece of equipment. However, running a :
scanner on a 24-hour basis only serves to
magnify the costs involved--and these
costs are ultimately passed to the patient
"The medical and lay communities must act together to prevent this very important achievement from becoming a political football."
The cost of CT scanning units is very high, with prices ranging up to $750,000 for the newest and most sophisticated units. It is hoped that over the years prices will be reduced, although this has not been the case with other types of X-ray equipment, where prices havesteadily increased. Ohio Nuclear recently marketed a dedicated head scanner at $95,000, presumably to circumvent the certificate of need stipula tion. The drawback to this otherwise com mendable unit is that it can accomodate only a relatively small number of patients. Most medical centers have managed to scrape together the necessary funds for a CT unit, recognizing it as a diagnostic necessity, though no one views such a pur chase lightly.
The.cost of maintaining a scanner is extraordinarily high (at our. institution it runs to $300,000 per year); the claim that scanners are money-making devices is patently false. This maintenance, figure includes various elements: Salaries for medical, technical and sec
retarial assistance--we have found it necessary to have two technicians on hand at all times that the machine is
--by the requirement for several teams of physicians and technicians and inevitable overtime payments. Examinations con ducted at odd hours are inconvenient for patients, and especially so for outpatients who may travel long distances to obtain . : the test. In addition, it is apparent that excessive use of CT equipment induces an increase in breakdown time.
Tho Task of the Future
In the CT scanner we have a remarkable
tool whose potential has hardly been ap
proached. The medical and lay communi
ties must act together in preventing this
very important achievement of modern
medicine from becoming a political foot
ball. Federal agencies are faced with solv
ing the very pressing problem of increasr
' ing medical costs; we in the medical pro-
fession are faced with keeping bureau
cratic intervention at a minimum. Above
all, we cannot allow our accomplishments
to go unused, nor our future to be subject
to irrational restrictions.
r@
VOL 28, NO. 2 MARCH/APRIL 1978
*00.1 b933