0) Tipping out Mjr pools of solvent on the- cleaned 'parts before rexoval fro* the vapor zone; and.
C) Allowing parts to dry within the degreaser until visually dry.
3) Porous or absorbent materials, such as doth, leather, wood or rope are not degreased:
4) Less than half of the degreaser*s open top area Is occupied with i workload;
5) The degreaser Is not loaded to the point .where the vapor level would drop more than 10 cm (4 In) when the workload Is > removed from the vapor Tone;
6) Spraying li done beloM the vapor level - only.;- '
7) Solvent leaks are repaired`taaedlately: .
8) Waste solvent Is stored'In covered . . .containers only and not disposed of In
such a manner that more than 201 of the ' waste solvent (by weight) Is allowed to. evaporate Into the atmosphere;
9) Water 1$ not visually detectable In solvent exiting from the water separator; and
. .10) exhaust ventilation exceeding 20 cubic .meters per mtnute.per square meter (65
. cubic-feet' per minute per square foot) of r degreaser open area Is not used, unless .necessary to meet the requirements of the Occupational Safety and Health Act (29 O.S.C. Section 651 et seq.).
b) Equipment Requirements: No person shall operate an open top vapor degreaser unless:
1) The degreaser is'equipped with a cover designed to. open and close easily without disturbing the vapor zone;
2) The degreaser Is equipped with the following switches:
A) A device which shuts off the sump heat source If the amount of condenser coolant 1$ not sufficient to maintain (he designed vapor level; and `
8) A device which shuts off .the spray pump If the vapor level drops more
. . than 10 cm (4. In) below the bottom condenser coti; and
C)' A device-which shuts off the sump heat source when the vapor level exceeds .the destgn level.
3) A permanent conspicuous labeV'Sunaariztng the operating procedure Is affixed to the degreaser;
4)-.- The degreaser Is'equipped with one of the following devices:
A) A freeboard height of 3/4 of the .Inside width-of the degreaser tank or 91 cm (36 In);-whichever Is less: and If the degreaser opening is greater than 1 square meter.(10.8 sqware
. feet).-a powered or mechanically assisted Cover; or
8) Any other'equipment or system of equivalent emission control as
approved-by the Agency. Such ; .- equipment-or system may Include a
refrigerated chiller, an enclosed design or a carbon adsorption system.
(Source: Amended at 3-111, Reg. 124. effective
Section 21.5.184 ' Conveyorized'OegreasIng
a) Operating Requirements: No person shall ..operate, a-.conveyorized degreaser--unless: .
',)) Exhaust- ventilation exceeding 20 cubic
meters pex. ot1aule. per. square meter,. 165.
cubic feet per mtnute per square foot) of
area<of loading arid unloading opening Is
.not used, unless necessary to meet the
requirements'or the OtcupatTonal Safety ~
and Health Act (29 U.S.C. Section 6S1 et
.... feq.JL-A
2). Solvent; carryout, emissions are minimized by;- -i
", A) Racking parts for best drainage; and
.8)-. Halntalnlng the vertical conveyor speed at less than '3.3 u/atn (11 ft/mln);
v 3)' liifstir soTvenTfr storetf' tn'covered
containers only-and not disposed of In such a manner that more than 2OX of the waste: solvent (by weight) fs alTowed to.
evaporate Into the atmosphere;
4) Solvent- leaks are repaired WUnedVatoVy; ~
5) Water Is not visually detectable In solvent exiting from the water separator:
and
6) _ Downtime covers are placed'over entrances . .and exits of conveyorized degreasers Immediately after the conveyors.and exhausts are shut-down..and not.;removed... until'just before start-up.
b) Equipment Requirements:' No person shall operate a-conveyorized degreiser unless:
)) The degreaser Is equipped with a drying . .. tunnel, rotating (tumbling) basket or
other equipment sufficient to^prevent
dexned parls. froc1. carrx.ta9. out . sol vent liquid or vapor;