Document yro1QoOayaV04w61G16J3Nejd

0) Tipping out Mjr pools of solvent on the- cleaned 'parts before rexoval fro* the vapor zone; and. C) Allowing parts to dry within the degreaser until visually dry. 3) Porous or absorbent materials, such as doth, leather, wood or rope are not degreased: 4) Less than half of the degreaser*s open top area Is occupied with i workload; 5) The degreaser Is not loaded to the point .where the vapor level would drop more than 10 cm (4 In) when the workload Is > removed from the vapor Tone; 6) Spraying li done beloM the vapor level - only.;- ' 7) Solvent leaks are repaired`taaedlately: . 8) Waste solvent Is stored'In covered . . .containers only and not disposed of In such a manner that more than 201 of the ' waste solvent (by weight) Is allowed to. evaporate Into the atmosphere; 9) Water 1$ not visually detectable In solvent exiting from the water separator; and . .10) exhaust ventilation exceeding 20 cubic .meters per mtnute.per square meter (65 . cubic-feet' per minute per square foot) of r degreaser open area Is not used, unless .necessary to meet the requirements of the Occupational Safety and Health Act (29 O.S.C. Section 651 et seq.). b) Equipment Requirements: No person shall operate an open top vapor degreaser unless: 1) The degreaser is'equipped with a cover designed to. open and close easily without disturbing the vapor zone; 2) The degreaser Is equipped with the following switches: A) A device which shuts off the sump heat source If the amount of condenser coolant 1$ not sufficient to maintain (he designed vapor level; and ` 8) A device which shuts off .the spray pump If the vapor level drops more . . than 10 cm (4. In) below the bottom condenser coti; and C)' A device-which shuts off the sump heat source when the vapor level exceeds .the destgn level. 3) A permanent conspicuous labeV'Sunaariztng the operating procedure Is affixed to the degreaser; 4)-.- The degreaser Is'equipped with one of the following devices: A) A freeboard height of 3/4 of the .Inside width-of the degreaser tank or 91 cm (36 In);-whichever Is less: and If the degreaser opening is greater than 1 square meter.(10.8 sqware . feet).-a powered or mechanically assisted Cover; or 8) Any other'equipment or system of equivalent emission control as approved-by the Agency. Such ; .- equipment-or system may Include a refrigerated chiller, an enclosed design or a carbon adsorption system. (Source: Amended at 3-111, Reg. 124. effective Section 21.5.184 ' Conveyorized'OegreasIng a) Operating Requirements: No person shall ..operate, a-.conveyorized degreaser--unless: . ',)) Exhaust- ventilation exceeding 20 cubic meters pex. ot1aule. per. square meter,. 165. cubic feet per mtnute per square foot) of area<of loading arid unloading opening Is .not used, unless necessary to meet the requirements'or the OtcupatTonal Safety ~ and Health Act (29 U.S.C. Section 6S1 et .... feq.JL-A 2). Solvent; carryout, emissions are minimized by;- -i ", A) Racking parts for best drainage; and .8)-. Halntalnlng the vertical conveyor speed at less than '3.3 u/atn (11 ft/mln); v 3)' liifstir soTvenTfr storetf' tn'covered containers only-and not disposed of In such a manner that more than 2OX of the waste: solvent (by weight) fs alTowed to. evaporate Into the atmosphere; 4) Solvent- leaks are repaired WUnedVatoVy; ~ 5) Water Is not visually detectable In solvent exiting from the water separator: and 6) _ Downtime covers are placed'over entrances . .and exits of conveyorized degreasers Immediately after the conveyors.and exhausts are shut-down..and not.;removed... until'just before start-up. b) Equipment Requirements:' No person shall operate a-conveyorized degreiser unless: )) The degreaser Is equipped with a drying . .. tunnel, rotating (tumbling) basket or other equipment sufficient to^prevent dexned parls. froc1. carrx.ta9. out . sol vent liquid or vapor; - 97 -