Document yrkvoZELd0mMB18RyEeJJzMxV
ABDOO127244
1996 Air Emission Calculations
Pollutant
Allowable Rate
Annual Emission
Tons per Year
Tons per Year
Particulate Matter
198.69
42.23
S02 5.36 0.28
NOx
198.72
63.82
CO
147.09
15.84
VOC
189.42
57.07
TRS
00
LEAD
0.56 0.56
CFCs/HCFCs
0
0
Other
00
Total HAP's (VOC)
139.16
14.42
Total HAP's (Non-VOC)
4.38
4.2
TImS
&
1994 Natural Gas Usage =(931642 MMB*TU
G* S ^ U-S
L&i k-
TSP/PM10 Calculation
AP-42factor = 0.005 LB/MMBTU
931642 MMBTU 0.005LB
1 TON
2 329 TPY
CJ (Lc*S\ -
,Out Volur^Ji Ouv-d
,,,
l,
7*^
YEAR
MMBTU
2000 LBS
^ Alkctdz/
From Fluid Bed & Rotary Dryers (Based on Stack testing) Emission rate = 6.4 # / hr * 8760 hr / yr * 1 ton / 2000 # = 28.1 TPY
Ce(l</wr\. \0fc4
From New Cyclone Dryer (Start up 6/96) (Based on Stack Testing) Emission rate = 2.06 #/hr * 8760 hr / yr * (7/12) * 1 ton / 2000# = 5.26 TPY
From Vinyl Silos
(Based on Stack testing)
Emission rate = 0.608 # / hr* 8760 hr / yr * 1 ton / 2000 # = 2.66 TPY
'fUcsc
(*2-
tUc
From cmpd silos
(Based on Stack testing)
Emission rate = 0.9 # / hr * 8760 hr /yr * 1 ton / 2000 # = 3.94 TPY
Total = 42.2 TPY
S02 Calculation 931642 MMBTU YEAR
AP-42 factor = 0.0006 LB/MMBTU
0.0006LB
1 TON
= 0.2795 TPY
MMBTU
2000 LBS
NOx Calculation 931642 MMBTU YEAR
AP-42 factor = 0.137 LB/MMBTU
0.137LB
1 TON
= 63.817 TPY
MMBTU
2000 LBS
CO Calculation 931642 MMBTU YEAR
AP-42 factor = 0.034 LB/MMBTU
0.034LB
1 TON
= 15.8379 TPY
MMBTU
2000 LBS
ABDOO127245
VOC Calculation 931642 MMBTU YEAR
AP-42 factor = 0.0057 LB/MMBTU
0.0057LB
1 TON
= 2.6552 TPY
MMBTU
2000 LBS
Total VOC from Plasticizer = 40 TPY
Fugative VCM = 0.3229 TPY (Obtained from Environmental Coordinator) VCM Stack Emissions = 13.844 TPY (EPA Method 107) Total VCM Emissions = 14.1669 TPY
Fugative Methanol Stack Emissions = 0.2525 TPY (Best Engineering Judgement)
Total VOC Emissions = 2.6552 + 40 + 14.1669 + 0.2525 = 57.0746
Total HAP's (Voc) = 14.4194--=4----- Idf-
Total HAP's (Non-Voc) Lead Calculation Assume Actual Lead Emissions = Permitted Emissions Total Lead Emissions = 0.56 TPY
HCL Calculation Assume Actual HCL Emissions from Incinerator = Permitted Emissions Total HCL Emissions = 0.38 TPY
OUL-V 3jQjluQ&
SlAckL
Chlorine Calculation
Assume Actual Chlorine Emissions from Incinerator = Permitted Emissions
Total Chlorine Emisions = 0.37 TPY
Fugitive Emissions:
1996 Average Well Water Flow =1184 GPM
Assume 0.5ppm Residual Chlorine in Water from Water Plant
O 0.5 # C12
1184 Gal
8.33 #H20
1440 Min
365 Day
MM# H20
Min
Gal
Day
Year
1.2960 TPY
1 Ton 2000#
Emissions from Cooling Towers Assume: 1) 25% of C12 fed to cooling towers is unreacted and emitted 2) That 6 2000# cylinders and 5 150# cylinders were used at the cooling towers
po&T[
PQXLVD&
6x2000#= 12.000# C12
5 x 150# = 750# C12
(12000 + 750) x 0.25 = 3187.5# C12
3187.5 #C12
1 ton
1.5938 TPY
yr 2000#
Total Fugative Chlorine Emissions = 1.2960 + 1.5938 = 2.8898 TPY
Total Chlorine Emitted = 0.37 + 2.8898 = 3.2598 TPY
Total HAP's (Non-VOC) Emitted = 0.56 + 0.38 + 3.2598 = 4.198 TPY
AtX
J/j 5/b^