Document yrb78D7jbGkKye42KVXgDrq4X
30 REFERENCE STANDARD FOR ELECTRICAL WIRES. CABLES, AND FLEXIBLE CORDS -- UL 1581
DECEMBER 17. 1991
TABLE 47.1 -- concluded
-
INDEX TO INSULATION AND JACKET MATERIALS
Material
Ap'plicable Table(s) or Paragraphs in This Standard
SBR/I1R/NR -- see "Rubber"
Silcone rubber insulation from Type SA Class 22 insulation and insulation from power-limited eircuit cable and power-limited fire-protectivesignaling circuit cable
Table 50.205 Table 50.210
TFE Class 12C PTFE insulation and PTFE insulation from
Type TFE
Table 50.219
'
TPE Class 36 105C insulation and jacket Class 36 insulation and jacket and insulation and jacket from power-limited circuit cable and powerlimited fire-protective-signaling circuit cable
Table 50.223 Table 50.224
XL 90C (194F) jacket from Type USE cable 75*C (167*F) jacket from Type USE cable Jacket from cable for deep-well submersible water pumps XL insulation from Type XHHW, SIS, RHH, RHW, and RH and power-limited circuit cable and power-limited fire-protective-signaling circuit cable
Table 50.228 Table 50.229 Table 50.230 Table 50.231
XLPE insulations: Class 29 Class 31 Class 33
Table 50.237 Table 50.241 Table 50.245
XLPO insulation: Class 38
Table 50.232
Table 47.1 revised December 17, 1991
50. Specific Materials
50.2 Class 19 impregnated-asbestos insulation
shall consist of the best grade of long-fiber,
Class 19 Impregnated Asbestos
chrysotile asbestos, commercially free from or
Insulation
ganic material and metallic oxides. The asbestos
shall be well carded to keep lumps and irregular
50.1 Class 19 impregnated asbestos is asbestos ities from appearing in the finished conductor
saturated with a flame-, heat-, and moisture- insulation, and shall not be loaded or weighted.
resistant compound. It is acceptable where sub It shall be applied as firm, compressed, felted
jected to 1500 C (302 F) and lower temperatures Fibers.
as insulation on Type AF Fixture wire. The
composition of the impregnating compound is 50.3 The insulation shall be thoroughly dried
not specified.
and then saturated with an electrically
Paragraph 50.1 revised December 17, 1991
nonconductive and flame-, heat-, and moisture-
resistant compound. The impregnating com
pound shall retain its initial qualities during the
normal life of the wire or cord, and shall not de-...
velop any damaging chemical action within itself
or with any component of the finished wire or
cord.
*Replaces page 30 dated December 16, 1991
COPYRfGHT 1983, 1991 UNDERWRITERS LABORATORIES INC.
0048