Document yrYg9LDm08XOLxMO3wRpkKzDd

ABD00059328 Results of the December 1997 VCM Emissions Survey P&ID Valve # PPM Location 1 VS-090105 56 18 1/2" bleeder valve on PI assembly off the discharge of PP-270 2 VS-090105 98 10 4" hand valve directly before the bleeder valve mentioned next 3 VS-090105 4 DY-090133 99 12 100 35 4" bleeder valve on pipe going from sphere to the units (across the RR tracks from sphere) 2" control valve after control valve loop on vapor/inert line going to DM-139 5 OM-090100 3 15 3" hand valve on top of DM-013 leading to a PT, PI, and an atmosphere 6 OM-090100 17 500 1 1/2" hand valve at the bottom of the lowest LG on DM-013 7 OM-090105 3 300 6" control valve leading from top of reactor to the recovery system 8 OM-090109 9 10 1" bldr vlv after a PI and rupture disk on a 3" line off of inlet line to VP-502 9 OM-090109 43 15 2" control valve on line from dump tank vent 10 OM-090109 57 15 2" hand valve on line leading to ERS from outlet of CP-504 11 OM-090109 58 10 3" hand valve on outlet of CP-504 12 OM-090112 45 10 2" hand valve leading into FL-691 from FL-008/009 13 OM-090112 14 OM-090112 15 NM-090105 16 NM-090113 71 121 152 155 10 150 10 110 4" hand valve on discharge line of PP-477 right before the line tees w/ the outlet of FL-691 1" control valve on line leading to the incinerators from the tops of the condensors on the receivers 1" control valve on line leading from the top of the condensor to the recovery system 3/4" bldr vlv on line off the bottoms line of DM-317E