CHLOROBIPHENYLS IN ortho AND para-PHENYLPHENOL
The following Is a brief description of the analytical procedure used to determine chlorinated biphenyls In ortho and para-phenylphenol .
Sample Preparation
Five grams of sample were weighed Into a 4-oz bottle, 100 ml of ^0.5M of sodium hydroxide was added and shaken to dissolve the sample. When the sample was in solution, 10 ml of benzene were added and placed on a shaker and extracted for 30 minutes.
Ion exchange resin DOWEX* 21K, 50-100 mesh, chloride form, was converted to the hydroxide form as described by W. Blaser in report ML-AL 59-371. A column 1.3 x 30 cm was prepared with a 15 cm bed of resin.
The contents of the bottle were transferred to a 125-ml separa tory funnel and the layers were allowed to separate. The lower aqueous layer was discarded and the benzene layer was drained off onto the column containing the resin. The benzene extract was drained to the top of the resin. After discarding the first 5 ml, a 7-dram vial was placed under the column. The walls of the column were washed with benzene and drained again to resin level-, more benzene was added until 20-25 ml had been collected in the vial.
The effluent was evaporated Just to dryness using a gentle air stream at room temperature. The residue was redlssolved in exactly 1 ml of cyclohexane.
The sample was then analyzed for chlorinated biphenyls by gas chromatography with flame or electron capture detection.
AN OAfAATINC UNIT O* TW( OOW C^IMfCAL COMPANY
HONS 021559
G. A. Clark
2- -
i
i
i GC Conditions
July 10, 1973
Instrument Column
Temperatures column Injection port detector
Carrier gas Range Attenuation Sample size
I II
HP-5750 with FID 6* x 1/8" r.5% Bentone
34 + 3. OK, DC-550 on 80/100 WHP
Pye-104 with BCD
4'x 1/8" 4.5% Bentone 34 + 3.01 DC-550 on 80/100 WHP
190*C 250*C
250*C helium at 40 cc/min I0a as needed 2 pi
170*C 150*C
300*C nitrogen at 40 cc/min 10a as needed 3 pi
GO-MS Conditions
Instrument Column Temperature Carrier gas
I yB 9000
8' X 1/8*' 5% OV-17 on 80/100 GCQ 200* and 160*C helium at 50 cc/mln
All the samples, from the starting material, to the final products: ortho-pehnylphenol were
analyzed using conditions I (flame).
The final products: ortho-phenylphenol and para-phenylphenol were also analyzed using conditions II (electron capture),
The final products: o-phenylphenol and p-phenylphenol were analyzed for total chlorine by neutron activation analysis.