Document yrMm0n8og0DGLKJBjMnvDvGNE
\` I
r. 7.C. Tolcy -- %'otj York
" r. Taul
- -.i. Louis
"r. 75 ,L. Jenkins -- Anniston
i^aaara. ~drur Z. Hardy
J.F. reeves (2)
A.U. cllcnburg.
R.P. Loewan
December SO, 1947
Celanese Corporation of Anerlea Central research Laboratory v Suoait. Rev Jersey
Gentleman*
Dr. L. 3* Bixnbaum
As sngrested by nr* R. L. Jenkins In hie letter to you on Deceabar 23, we ere nleaced to write cb'iut /.rocior toxicity considerations.
The host published Information ::bout the toxicity of Aroelor vaporo
with reference to possible dona re to tie liver Is In a series of
three ortlolea written for tho Jo'irr.tl of Industrial Ryrlena and
Toxicology. The first article apoecrinir in the September 1937 Issue,--"* -
Vol. 19, No. 7 and the second crtiele nubllnh^d in the February 1938
issue, Vol. 20, No. 2 were written by C..P7. Drinker, 15. F. Tsrrcn, and
0. A. Bonnet and cower only Aroclor &4o9. The third article rvltten
by Dr. Drinker alone is sore co-ilc.to os It Rives Information about
Aroelors 4465, 1254, 1268 and 34G0. 'a particularly wish to refer
you to this.artiolo entitled, '"urther Observations on the Possible
Oyotenic Toxicity of Certain of the Chlorinated Hydrocarbons with
suggestions for Permissible c -- ontr-iions :n the Air of VorJarooms",
-.by Cecil X. Drinker, The Jou: .-.1 of I.~ uotrlal Hygiene end Toxlcolopy.
Vol. 21, Ho. 5, Key, TSST,
In this article Dr. Drinker t jU-lstes the. ccmissible Halts of the compounds In ag. per euble enter of elr in rorkroaas. The following
date in an exaerpt pertaining to permissible lioits of various Aroelors:
Sfcterlsl
Sb. 6
Ho. 9 So. 13 0. 14
Aroelor 4<65 Aroelar 1254 Aroelor 2268 Aroelar 5460
Permissible Linit Vk. per Cu. tf.
0.5 0.5 10.0 0.3
.
\
Troa this, it is noted thst there is a carkod variation in the toxlelty
of the vapors of different .\r*clo?o. ''o ruote Dr. Drinker, "Aroelors
1268 is alcost noD-taxie*. t:u verors of the other Aroelors studied are
toxic end
be evoldod. -i ."icrai, the acre highly ehlcriceted
biphenyls are less tosAe than tv-o it -r cklorlneted derivatives, probe*
SCM 021423
WATER PCB-SD0000026725
bly duo to deereaGed eolubill';'. r -c chlorinated tcr^hcnyls appear
to b nor* toxic than ooriu- .
aMiviustod biphonyls.
"/hero the cold or solvnnt. rtf *.! i,-
T*tt the irspregnstion of
Aroclara usually only normal rrcsutijr.s or ordinary cleanliness
of comcrcial plant practico -.ro
Mien the .\roclors ere .
eppUod by hot methods, SCO* ' . or higher, the woriaroons should be
Tontllotod by Intake and tv." -.i f-..c of mfflelent volume and
eloelty to removo the najorlty of the fuses, Where ercr drying
ovens are usedk the Vapors rust bo ramrod. 9ugreatlons about this
ere given in the ortlels entitled, "Observations on tbs Toxio Sffecta
Resulting fToa Exposure to Chlorinated Naphthalene and Chlorinated
Phenyls with Suecostlons for '.'roventlsn", by Dr. H. Ton Tedel, Dr. 3a.
A. Holla and Dr. Jaaes Donton, published in The Rubber Ace. Yol. 53.
No. 5, August 1943.
.
In General, it is bellevod that the
persissible amount of
Aroelor vapor in the workroom is evident to the worknea because of
an irritating influence on the eye membranes. It tborcfare beoeases
a self-revealing slgoal when dan'rrous lovels are reached.
If you desire, as vill be glad to lend you an Instrument nbich as have with full instructions for its operation to soasure Arcelor vapors in your workroom atmospheres. This would be tho most certain method to detenains that your aorkinc conditions are safe.
*
In your latter of Deeeabor 19 to Dr. Jenkins, you ssksd ahether studies have bean nods of tho possible toxicity or dermctltin due to finished mnufsotuzad lteas containing Aroelars es an ingredient.
.It aes determined by the skin patch test proesdure given by Dr. Louis
Dchnartz and Sr. .`femel 32 I\iek in reprint flb. 2553 fron tho Public Health Reports, Yol. 39, Ho. 17 (April 23, 1944) that cnnvac painted with Aroelor 5460 and an oil ro",triad alkyd resin in such a ranner that each stpiare inch of fhbrio costsined 10.3 mg. of Aroelor 5460,
ass neither a skin irritant nor - .tcr.3ltir.er.
The following soisacreial applications are some typical large current
outlets for Aroelora sad to our knowledge, there is no instance of .
difficulty about toxicity even thwih in i number of these sppllcatldta
alsratsA tenpenturea are used and consamara coma in rather elosa'
contact with the finished earidity containing Aroelor.
737130 U3S
1. Actuating fluid for thrrsostats.
2. Heat transfer sodium. 3. Non-flammable hydro-ills fluid, especially .
for die easting nr chines.
4. Adhesives for cany -urpsraai 5. Wood preservative sad sealer treatments.
6. Air compressor lubricant.
7. Plasticiser for nitrocellulose, ethyl Cellulose .
and polyvinylchloride costings. (In a number of
applications of this type the eonmmar ooass In
--
iniBiRii 030608
WATER PCB-SD0000026726
.1
)
Intimate contact with the cm ting compositions*
A good example la cootod heels of ladle** she**).
8. Plastlolzr for Purlom. and Pllolit* paints and
coatings*
9. Plasticizer for air* Insulating compounds*
10. In tran3foraors and capaoltora*
11 Aa an lapregoant for papor products*
12* Preosura sensitive 3oalers*
-
13* In fire ratordant paints and coating*.
14* Inpregpant for textile*
15* Industrial printing, ink*.
16* Stop-off luoquero for electroplating.
17* Ceramic* glaze printleg.
18* Plasticizer for asotrlt conpoeltions*
19* In tb* nannfaetur* of dentures*
Based on oor praetlcal experience In the masnfaeture and sals of millions of pounds of Aroclors annually* the point that me mould emphasize is that markers ehor.ld not he exposed to Aroolar vapors and that the sen morkln.'* mith .\roelor3 should observe "good house keeping" rules about keeping tholr clothing and skins fraa of the material and avoid Insertion of it.
II Adequate ventilation has proved successful in keeeing the stmosphere free from harmful amounts of .'roclare around machinery and in
plants*
V^hen you have had opportunity to '-V^e consideration to our above comments* please let ua have ycur thoughts and let u* know If me can ho of further asalstanco to you.
.
Tours very truly*
\
rfc
Copied hy re 1/5/48
7. p-nlgBus ScvelopoaBt Department
SCH OH1*25 030609 WATER_PCB-SD0000026727