49 Such monitoring programmes should concentrate primarily on areas where potential sources of asbestos emissions are present. 4. The iDOnitoring should be done at fixed sites with continuous sampling on filters. In view of the biological importance of integrated exposures and to reduce the number of samples# each filter should sample continuously for one wrek or r:ore.
Gravimetric determinations should be done on most of the samples; a fibre count and sire an2 limited Identification (chrysotilc and amphiboles) on a selected number) and a detailed identification on a few samples.
5. An intercomparison programme ha6 been initiated by the Commission in order to gain knowledge about tYc magnitude of the possible differences which may be found in the results. Standardisation of sampling and sample pre paration methods would be considered, as necessary, in a second stage. The results of this programr.se will help determine the point in time when routine monitoring for asbestos in air could be undertaken.
Wat cr C. Prinking water is not monitored systematically for asbestos in most
Member states; however, a few specific studies have been conducted.
7. The analytical techniques applicable to air samples can also be used for water. Jn general, the monitoring programme for asbestos in wtor a: the tap may be much less extensive than for air, but attention sh'vtld be paid to areas where water mny cor* in contact with asY e.ttos material. Most of the samples might be examined by optical microscopy with a few random samples check.d by electron microscopy with the same procedure as descrJY>cd for air.
8. The sampling end preparation problems involved with the detei^nation of asbestos materia) in other beverages and food items is mot complicated than for drinking water# and monitoring could be envisaged only vho.i there is a suspicion of contamination.
& 0 01 fl 7 < ?