Document yrBK5yLBgdba2kzYx0L128ReD
270
Heating System?
COLUMBIA Boiler Company of Pottstown
Pottstown, Pa. Makers of steel power and heating boilers
PACKAGED HRT* AND VERTICAL TUBELESS BOILERS AND STEAM GENERATORS TANKLESS INDIRECT WATER HEATERS
HRT* PACKAGED GENERATOR A.S.M.E. Code Construction, Oil or Gas Fired, 2 to 100 H.P. Com> . plete. Automatic Power Plants for Every Steam Processing or Hot Water Heating Need.
Designed tor tiring with gas, light or heavy oils; available with combination burner for interchangeable use of gas or oil.
COMPLETE DEPENDABLE EFFICIENT
Unit includes boiler, burner, gauges, controls, jacket, insulation, etc. It is shipped fully assembled, fully piped and wired, factory fire tested . . . ready for operation on arrival. Every part, every accessory was designed for maximum functional efficiency in proper relationship with all other parts. Problems of installation and service are thus reduced to a minimum__ and maximum efficiency is assured.
HIGHER STEAM OUTPUT, MORE EFFICIENT HEATING, SIMPLIFIED SERVICING
Having a greater heating surface than most makes of the same or higher ratings, the COLUMBIA generator produces more steam or hot water at higher efficiencies. More heat is converted into steam, more heat is transferred to water. It is proportioned to make maxi
mum use of the hot gases of combustion . . . rapidly heating re fractory surfaces and extra insulation enhance efficiency. Front and back access to tubes by easy removal of cover plates makes cleaning and inspection a cinch.
HORIZONTAL RETURN TUBULAR
Bp Ratio*............................ Lrnvtb O-A......................... Width O.A. .................. .................... in.
Water Heating Surface... 03 Filial Rate................... Gaa or 03 Inpat................ Approximate Output.........
72 42 60 30 2.00 280,000 200,000
8 81
64 56 2.30 400,000 300,000
10 81 44 H 66 72
490,000 350.000
15
51
92 .so 700.000 500,000
900,000 700.000
1,000,000
1,200,000
60
415 2.600.000 1,800,000
3,600.000 2,700,000 3.400,000
VERTICAL TUBELESS
STEAM GENERATOR
Multipass tubeless design provides maximum heat transfer
Requires minimum floor space Bottom firing and top vents eliminate
- gas traps Large full area steam space insures
dryer steam McDonnell & Miller float operated low
water cutoff and pump control with provision for electric probe type cut off a Full three inches of insulation mini mizes heat loss Refractory combustion chamber in sure* more complete combustion Easy access provided for cleaning and inspection--without need to remove controls Conventional gun type fuel burning equipment, standard controls eliminate need for specialized service Pressure fired and sealed to avoid need for slack or chimney AS-M.E. constructed and stamped--welds X-rayed and stress relieved.
SPECIFICATIONS AND DATA
H. P. Ratio*
S
Approx. Input BTU per Hoax.... 2(0,000
Approx. Inpat Gab. per Hoar....
1.75
Apwox. Output BTU per Hour..
180,000
Boiler Height................................
4OH*
Boiler Diameter............................
23'
Approx. Floor Space..................... 2H' x *w
Max. Operating Pressure FSI___
100
Approx. Shipptn* W*t..................
7501b
>0 IS
420.000 3.00
340.000 "S'-
3' * S' 125
1350 3*
630.000 4.50
510.000 68H* S3*
W' * S' 125
15501b
25
1,200,000 8.00
830,000 76X* 39*
4' x 6' 125
21501b
TANKLESS INDIRECT WATER HEATER
A.5.MJE. Code Construction, SBI Rated
A dean, dependable source for every hot water need. Instantaneous indirect heat ing with copper coil . . . ensures against destructive corrosive action of raw water developed in direct fired heaters. Provides an abundant supply of dean, rust-free hot water at all times . . . from 190 to 1200 G.P.H., continuously at 100 deg. F. risff. Ample combustion space and insulation completdy eliminate objectionable noises.
MODEL NO.*
Boiler-Burner Units WHL20 TWHU6 TWHU0 TWHW8
RATINGS Input--Gab per Hr........................ BTU per Hr....................................
He*tin* Sorface--Sq. Ft................ Gab. per Hr. 80* F Rise................ Gab. per Hr. 100* F Rise..............
1.35 190,000
32.5 240 190
5.50
770,000 110.0 970
740
7.00 980,000
120.0 1160 940
9.00 1.260,000
182.0 1500 1200
HEATER DIMENSIONS
Height............................................. 42' 60* 66*
19' 30* 32*
Length.............................................
24*
35'
40*
66* 32' 48*
UNITS AVAILABLE IN ALL INTERMEDIATE SIZES
^
with BTC's per hr. of 280,000.310.000.490,000,430.000,980,000, 1.400.000.
'.Heating Systems
271
COLUMBIA Boiler Company of Pottstown
Pottstown, Pa. ;} Makers of steel power and heating boilers
? STEEL WATER TUBE AND TUBELESS LOW PRESSURE HEATING BOILERS ^ WITH 20-YEAR GUARANTEE
Water Tube
Tubeless
ASJH. CODE CONSTRUCTION, SBI Rated, A.G.A., SUR and liL Approved
Oil or gas fired; fully equipped with no extras needed. Burners are custom engineered for maximum operating efficiency, self-contained large copper instantaneous tankless coils provide a continuous flow of year 'round domestic hot water. MAXIMUM EFFICIENCY:.The arrangement of baffles or tubes forces the hot gases to travel five times the full length of the boiler, effecting maximum beat transfer. Finest quality copper bearing boiler plate of uniform thickness assures fast heat transfer, longer life. QUIET OPERATION: Ample combustion space, insolation and heavy jacket completdy eliminate objectionable noises.
L-16
gotwtgi--Oil Fired Input--Gals per Hr..................... Sol Net Rating Sq Ft Forced Water..................... Sq Ft Gravity Water................... Sq Ft Steam.................................. Btu per hr Forced Water............ Btu per hr Gravity Water.......... Btu per hr Steam.........................
1.00
580 510 320 87,000 77,000 77,000
L-18
L-20
L-22
L-24
L-30
*L-32
L-36
*L-40
*L-48
1.20
1.35
1.75
2.25
3.00
4.00
5.5 7.00 9.00
720 640 400
108,000 96.000 96,000
990 880 550 149,000 132,000 132,000
1260
1120 700 189.000
168,000 168,000
1620 1440 900 243,000 216,000 216,000
1980 1760 1100
297,000 264,000 264,000
2700 2400 1500 405,000
360,000 360,000
3750 3300 2050 560,000 495.000 49S.000
4800 4200 2600 700,000 620.000 620,000
6100 5400 3400 915,000 810,000
810,000
' Constructed Water Tube Only Gas Fired Units A.GA. and SUR Approved for outputs from ?200 to 1,008,000 Bin's per hour.
PACKAGED TUBELESS LOW PRESSURE OIL OR GAS BOILER-BURNER HEATING UNITS
AS.M.E. Construction
BOILER CARRIES 20-YEAR GUARANTEE
FULL FLOW BASEBOARD RADIATION
A marvel of heating efficiency, it provides positive assurance of minimum installation coat. Equipped with large copper instan taneous (tankless) coils for a continu ous flow of domestic hot water. Fully pre wired at the factory, with controls com pletdy installed . . . has attractive two-tone gray extended steel jacket . . . leaves nothing to be done except to remove wrappings and connect utilities. Complete unit skidded and folly enclosed in strong carton for safe shipment.
Unique base lip assures full heating efficiency with wall-to-wall carpeting
New magnetic damper assures secure positioning
Noiseless performance assured by 1. Interlocking fin spacing tabs. 2. Floating dement 3. Adhesive pads attached to element. 4. Front cover hdd firmly in place by nniqne tension spring action bracket.
TULL-FLOW unpainted alumiaum-filf design on copper beating dement
Simplified installation: Pre-flared cop per tubing ends, snap-on brackets. No tools required.
All endosure parts have baked white enamel finish
2-TIER UNITS ALSO AVAILABLE.