Document yr7Oyb36EZQovD0OyVdOq8G2E
References
1. Taylor, 0. 6., R. E. Kupel and J. M. Bryant, Documentation of the NIOSH Validation Tests, DHEW (NIOSH) Publication no. 77-185.
2. Gunderson, E. C. and C. C. Anderson, Development and Validation of Methods for Sampling and Analysis of Workplace Toxic SuDstances, DHHS (NIOSH) Publication No. *80-133.
3. Palmes, E. 0. and A. F. Gunnison, Personal Monitoring Device for Gaseous Contaminants, Am. Ind. Hyg. Assoc. J., 34, (1973).
4. Reiszner, K. D. and P. W. West, Collection and Determination of Sulfur Dioxide Incorporating Permeation and West-Gaeke Procedure, Environ. Sci. and Tech. 7, 526 (ly73).
5.-' Posner, J. CC. tetter to the Editor, Am. Ind. Hyg. Assoc. J., 42, A-28 (1981).
6.' Moore, G., Letter to the Editor, Am. Ind. Hyg. Assoc. 0., 42, A-26 - (1981).
7.
{/ 8.
Thain, W., Monitoring Toxic Gases in the Atmosphere for Hygiene and Pollution Control, Pergamon Press, New York, New York, (1980).
Krajewski,J., J. Gromiec and M. Dobecki, Comparison of Methods for Determination of Desorption Efficiencies, Am. Ind. Hyg. Assoc. J., 41, 531 (1980).
9. Densley, M. D., Charcoal Tube Air Sampling of Organic Vapor Mixtures, Doctoral Dissertation, Department of Environmental Health, College of Medicine, University of Cincinnati (1981).
10. Strategy of Experimentation, 2nd edition, E. I. duPont de Nemours and Co., Wilmington, Delaware (1975).
1-1. Hemeon, W. C. L,, Plant and Process Ventilation, 2nd edition. Industrial Press Inc., New York, New York (1963).
12. Palmes, E. D., A. F. Gunnison, 8. DiMattio and C. Tomczyk, Personal Sampler for Nitrogen Dioxide, Am. Ind. Hyg. Assoc. 0. 37, 570
(1976).
13. Mullins, H. E. and L. W. Anders, A New Innovative Diffusional Monitor for Sampling Ethylene Oxide in Air, 3 M Technical Report R-AIHAI (71.1)R (1981).
25
3M 0020S3
BIAS {%)
FIGURE 1. COMBINATIONS OF CVT AND BIAS WHICH YIELD NET ERRORS (Sampling and Analysis) OF 25% OR LESS AT LEAST 95% OF THE TIME
The critical estimates curve shown is for three sets of six samples. This curve will be slightly different for larger sample sixes.
nn^nad
Appendix Mathematics and Statistics Used in Evaluation
The statistics used are essentially those described in references 1 and 2 adapted for passive monitors. These statistics are based on the assumption that the total sampling and analytical error should be less than 25% for at least 95% of the samples analyzed at levels of 0.5 - 2.0 times the PEL. In order to meet this accuracy requirement the experimentally determined total coefficient of variation (tVj) must be less than 0.105 for an unbiased method (1). For a biased method, the critical "CVy is
reduced according to the graph in Figure 1.
Definitions: Mean = x = arithmetic average n = number of observations
standard deviation = s
i(xi-'x)2 HI_________
n-1
Coefficient of variation = CV = s/x
CVy x CV of the 6 spiked samples at each concentration level. CV2 = CV of the 6 generated samples at each concentration level.
Pooled coefficient of variation = CV = / Xf; (CV.)^
Y
where:
f-j = degrees of freedom (n--1) at each concentration level CV i = CV of the observations at the it*1 concentration level
i a index for the three concentration levels f = Z fi
51
TVy = pooled CV based on the spiked samples at 0.5, 1.0 and 2.0 X PEL (6 samples at each level)
^2 - pooled CV based on the generated samples at 0.5, 1.0 and 2.0 X PEL ( 6 samples at each level)
CVT = pooled CV for sampling and analysis and desorption efficiency *
CVT + 0.1667 (CVy)2
Grubbs test (1,2) should be used to determine if an observation should be rejected as an outlier and Bartlett's test for homogeneity of CV1 s (1,2) should be applied to determine the feasibility of pooling the CV's. Chi-squared must be less than 9.21 to pass Bartlett's test at the 1% significiance level (1,2).
*Note that an assumed pump error of 5% is not used in these calculations
sinrp nnmrv; are nnt usprl with nassivp monitors anrl camnlinn prror will ho ;>
part of
3M 002085
Am Ind. Hyg. Assoc. J 43(8f605-621 (1982)
The history of development and validation testing of passive dosimeters is reviewed. Theoretical considerations, including possible limiting factors or interferences, are presented. Laboratory and field validation tests ar critically reviewed and results are presented for comparative purposes. Evaluation of available data indicates that passive dosimetry, with some exceptions, is an acceptable method for monitoring gasses and vapors. Most importantly, passive systems appear to be as reliable as the now accepted active sampling systems.
Passive dosimetry -- state of the art review
VERNON E. ROSE and JIMMY L PERKINS School of Public Health. University of Alabama in Birmingham. Birmingham. At 35294
introduction
Recognition, evaluation and control arc the cornerstones of the application of that mixture ol science and art know n as industrial hygiene. These three tasks, however, are no longer the eminent domain of the industrial hygienist. In the past decade, a proliferation of training in the recognition of workplace hazards has been made widely available to workers and management alike. At the other end of the spectrum has been the training of individuals highly special ized in the control of specific hazards, especially those involv ing noise and toxic air contaminants. These develop ments are welcomed because they contribute significantly to the ultimate goal of protecting the health of workers by providing safer and more healthful workplaces.
At the same time, professional industrial hygienists rec ognize that often the critical step in the process is not recog nition of toxicity, but evaluation of hazard which leads to the subsequent development of the most effective means of coniro) where warranted. This key step of evaluation is the unique domain of the industrial hygienist, often supple mented by other members of the occupational health and safety team. Where evaluation requires thedetermination of worker exposure to airborne toxic substances, the industrial hygienist has seen a revolution in the development of sophis ticated techniques and equipment.
The "organ-grinder" impinger sampler is a relic, having been replaced by constant flow , eight-hour battery-operated pumps, light enough to be carried by the worker. The liquid bubbler and impinger have been replaced by the charcoal and chemical substrate sampling tube. The laboratory has come to the field in the form of the portable gas chromato graph and infrared monitor, albeit w ith a price rise directly proportional to the sophistication of the equipment. Even the once lowly, direct-reading detector tube has become legitimate with the establishment of government programs to certify accuracy and precision.
But while most evaluation techniques were reaching the point w here the industrial hygiene staff required the addition of someone with a Ph.D. in electrical engineering, a new dev ice has appeared which has the key of simplicity -- the
personal passive dosimeter: personal, because it can he worn by the worker in close proximity to the breathing zone: passive, because there is no pump to move the air over a collector, which equates to fewer calibration and mainte nance problems. Some quarrel with the term dosimeter, with purists preferring to call them collectors, monitors, or samplers. While many of the devices are collectors and require the application of subsequent analytical procedures, others provide for a more direct measurement of "exposure dose." Their basic appeal, however, is simplicity ol use. Theoretically, elaborate calibration procedures are unneces sary. and all that is needed is a fairly reliable timepiece to measure exposure duration. There is some recognition that temperature and humidity may affect the observations: therefore, most manufacturers adv ise the user to report these environmental conditions to the analytical laboratory pro cessing the dosimeter.
Rather than viewing passive dosimeters as a not her way to replace the industrial hygienist, industrial hygienists must recognize and appreciate the potential of the dosimeters in helping to achieve the hygienists' goals. That potential is significant in that personal dosimeters, if properly used, offer the opportunity to revolutionize the evaluation step. The parallels with detector tubes, as well as with noise and ionizing radiation dosimeters, are obvious. Indeed, the parallel with radiation dosimeters, especially film badges, is striking. The opportunity to significantly expand the mea surement of worker exposure to many toxic materials can provide a quantum leap in our ability to provide safe and healthful workplaces. With any sampling device, however, there also must be the understanding that use ol such dev ices is only one part of the evaluation step. T he concepts of proper selection of workers at risk: the understanding of limitations, interferences and similar factors, and ultimately the proper interpretation of the results are still key ingre dients in the evaluation step. The possibility of "lalse nega tive" decisions leading to erroneous assumptions of safety. or "false positive" conclusions leading to unwarranted expenditures of resources for controls, still exists regardless of the measurement device used.
Co0v1,8hl
Am*ric4i Industrial Hv^ifru?
American Industrial Hygiene Association JOURNAL
(43J f 63
3M 002086
605
With the rapid proliferation of passive dosimeters in the past several years, it is appropriate that industrial hygienists evaluate the "state-of-the-art"and. as professionals, become involved with the proper application of these monitor ing devices.
theories of operation
In that passive dosimeters by definition do not use an air moving device to transport contaminated air to a collector, natural forces are relied upon to ensure that a representative amount of contaminant is "seen" by the detector. To date, one of two principles has been applied in the design of dosimeters. The first, and most widely used, is the principle of diffusion of contaminant molecules through a stagnant gas (air) layer. The second principle invokes the absorption in and subsequent permeation of contaminant molecules through a membrane.
Diffusional monitors rely on the movement of contami nant molecules across a concentration gradient which for steady-state conditions, can be defined b> Tick's First l aw of Diffusion:1"
W = -DA d~\
ID
where: W = mass transfer rate, ng sec. D = diffusion coefficient, cm" sec. A = cross sectional area of diffusion path. cm", and
dc d\ = the instantaneous rate of change in concentra tion o\er diffusion path, (ng cm3)cm
Considering the change in concentration (C) -- Cn) over the total diffusion path length (Xi -- X.i = --l ). equation (1) becomes:
W = D^tC, - C,,)
(2)
where. 1. = length of the diffusion (static) path. cm. C) = ambient concentration of contaminant, ng cm3, and Cn = concentration of contaminant at collecting sur face. ng cm3.
II an effective collection medium is employed, the contam inant concentration at thesurface of thecollector(Cn)can be assumed to be zero, and multiplying both sides of equation (2) by time. yields:
M = r>p(C,)t
(3)
where: M = total mass transferred, ng. and t = time that the badge is exposed to the contami nated air. sec.
It is also interesting to note that the units of the product of Dand A.divided by l..are cm3 sec. whicharethe same units associated with active air-mo\ing devices such as personal sampling pumps.
Rearranging equation (3) as follows:
rC'~- DmM
**>
it becomes apparent that me lactors affect the measurement of the ambient airconcentration of a substancc(Ci). Two ol the factors (L. and A) arc physical parameters associated w ith the construction of the dosimeter, one (M) is provided by measuring the total mass of contaminant collected by the sampler, another is the duration (t) the sampler was ex posed to the contaminated atmosphere, and the final factor (D) i> an individual property of each vapor or gas. It also i* known'" that the diffusion coefficient is directly propottional to the absolute temperature (T) of the vapor, raised to three-halves power and inversely proportional to the atmo spheric pressure (P).
Dosimeters that rely on the principle of permeation through a membrane are especially useful w here the contam inant of concern is usually found mixed w ith other interfer ing vapors or gases or when a liquid collecting medium is employed. The goal then becomes to identify a membrane material that is highly permeable to the contaminant of interest and impermeable to most other components in the atmosphere, and or the collecting media.
The determination of ambient concentrations of a con taminant usinga permeation dev ice can be determined from the formula:
C = wk i
(6)
where: C = concentration of contaminant, ppm, w = mass of contaminant collected, pg. k = permeation constant, ppm-hours pg. and t = exposure time, hours.
The permeation constant (k) is determined experimentally and is a function of the specific membrane material and contaminant of interest.11''
sources of measurement error
The most obvious sources of error for both types of passive dosimeters are apparent from equations (4) and (6). Com mon to both badges are determinations of the mass of con taminant collected and the time of exposure of the dosimeter to the contaminated atmosphere. For the diffusional moni tor. accurate knowledge of the physical parameters asso ciated with badge construction (length and cross-sectional area) and the diffusion coefficient of the contaminant arc important. There are at least nine prediction methods for calculating the diffusion coefficient, and in one study com paring observed and expected values for more than 100 compounds it was not uncommon to have less than 50 percent of the calculated results within 5 percent of the observed.131 Montalv o has described a procedure for limiting errors associated with computed diffusion coefficients.'3' At
3M 002087
Am lot) Hy[ Assoc J (A3)
Aufus; !S.`
least one manufacturer, the 5M Company, makes available its procedures for determining sampling rates I DA. L)for its badges.*5' Its approach has been to experimentally determine the sampling rate for fi\c or six compounds in a chemical family to establish the relationship between the diffusion coefficient and the measured sampling rates. Sampling rates for other compounds are determined from the diffusion coefficients calculated by the Hirschfeldcr equation and the empirical relationships dc\ eloped from the test compounds. T he rationale for the selection of the Hirschfelder equation is not gi\cn. but in the study of the nine diffusion coefficient formulas, the author concluded that for higher molecular weight compounds the Hirschfelder. Biard and Spat7 equa tions were in closest agreement with determined values.13' Bor the permeation monitor, accurate determination of the permeation coefficient for each monitor is neecssarv for obtaining accurate results. Factors influencing permeation include: thickness and uniformity of the membrane, affinity ol the membrane for the analyte, swelling or shrinkage of the membrane, and possible etching by corrosive chemicals.
The problems associated with accurate determinations of the mass of the contaminant collected are similar to those involved with other collection devices such as charcoal or silica gel tubes, or to those in which the collection of the contaminant inv olves a chemical reaction w ith the collection medium. Using known amounts or concentrations of con taminants to determine collection and or desorption effi ciencies is as critical a step for passive dosimeters as it is for other methods ol collection. Saturation of the sorbent as well as the subsequent accuracy of analy tical techniques are also part of the total error associated w ith the measurement.
Another common concern in all types of environmental measurements is the potential for interferences, either posi tive or negativ e, from other contaminants in the sampled air. As the evaluation of passive dosimeters has matured, increased attention is being paid to possible interferences in multi-contaminant exposure situations, in both the labora tory and field. In evaluating such interferences it should be recogni7cd that there are several potential sites for such interferences to appear, c.g., effects on adsorption or absorption efficiency of the sampling medium, chemical reactions of two or more contaminants prior to analysis, and the multitude of interferences associated with analysis of complex mixtures of gases and or vapors. These problems also are found in the more classical sampling and analyti cal methods.
Accurate measurement of the time the sampling device is exposed, is essential to most industrial hygiene sampling procedures. For both short-term and full-shift exposure measurements, errors less than one percent, i.e. 9 seconds in 15 minutes and 4.8 minutes over 8 hours, are not unreason able goals.
For the diffusion coefficient and possibly the permeation constant, it would appear that threefactors have thegreatest effect on variability. These lactorsare thetwoalready identi fied. temperature and pressure, and. less readily apparent, the velocity of the air external to the badges.
Considering temperature and pressure, and referring to equation (5) it can be shown that a temperature rise from 5 to 55 C would give a 16 percent increase in the diffusion coefficient, while a rise in barometric pressure Irom 710 to 810 mm Hg would cause a 14 percent decrease 11 However, at the same time, the changes in temperature and pressure also arc affecting the concent rat ion (mass volume: actually. density is the proper term but most authors use concentra tion) of the contaminant in that concentration is inversely proportional to the temperature and directly proportional to the pressure. Asa result, the total mass(M)collected by the dosimeter is only slightly affected by temperature (M 11 ~) and is independent of the pressure."' Consequently. w bile at ambient temperatures, the diffusion coefficient will increase about 0.5 percent per C. and the total mass collected by the sampler will increase less than 0.2 percent per C. There!ore. a temperature change from 25 to 50 C. if uncorrected, w ill introduce a measurement error of less than one percent, while a change from 5 to 55 C. if uncorrectcd. would introduce an error of about five percent.
The final source of error to consider is the velocity ol the air external to the dosimeter: often this is referred to as lace velocity. In an early assessment of face velocity eflccts. espe cially the lack thereof. Tompkins and Goldsmith point out that the important consideration is to contain all resistance to contaminant transport within the stagnant air layer inside the device."' As Jonas el at, subsequently noted, the lace velocity directly affects theconcentration gradient Ci~C.. in equation (2). and Ci can no longer be assumed to be the ambient concentration when the air external to the badge is stagnant.'6' With 7ero or low face velocities, the lengih (I I ol the diffusion pathway is effectively extended, and there is a decrease in the measured ambient concentration In Tompkins'and Goldsmith's work with the GASBADGETM. they determined experimentally that as long as laec veloci ties were greater than 7.5 cm sec (15 fpm) there was "no significant effect on dosimeter response:" however, experi mental results supporting this conclusion were not pre sented.High face velocities may also affect the concentra tion gradient. Commercially available diffusion devices rely on either a large ratio of diffusion path length to delu sion tube diameter or a wind screen to limit errors from this condition.
One of the most comprehensive tests todocument sources of error has been conducted under contract for the National Institute for Occupational Safety and Health, and although concluded, it is not yet available as a public report. The study involved evaluation of the GASBADGE and 5M Organic Vapor MonitorTM (the DuPont badge not being available at the time the study was initiated I via challenge with several organic vapors. The factors investigated were precision, effects of storage, maximum and minimum levels of quantification, face velocity effects, ellects ol temperature and humidity, off-gassing (related to storageexposure to mixtures, problems associated with applicable analytical methods, and adsorption ol the contaminant by the badge itself with subsequent leaching to the sensing surface. The possibility of adsorption by the badge body, thus giving
America Industrial Hyptenp Association JOURNAL
t*3l 8 82
3M 002088
higher results if the contaminant is subsequently released to the active medium, is of special concern in using passive dosimeters to measure very low ambient concentrations such as might be found in air pollution studies. Such interest and concern arc evidenced by research on the subject being sponsored by the ll.S. Environmental Protection Agency (EPA).'*' Because of the lower concentrations involved with air pollution studies as.opposed to workplace environments, the EPA also is concerned with the background or postmanufacture contamination levels associated with the sens ing medium. Initially, the focus concerns organics and acti vated charcoal.
In summary, although numerous factors may affect the final calculation of concentration, only face velocity and the determination of the diff usion coefficient are unique sources of error for passive collectors. Therefore, if face velocities arc sufficient to prevent "starvation"(probably greater than 7.5 cm sec) and if diffusion coefficients have been accurately calculated orexpcrimentally determined, passive dosimeters should give results comparable to those obtained w ith tradiional active sampling systems.
statistical considerations
In evaluating any new monitoring method, extensive laboraory and field testing is necessary. Interpretation of the results of these tests requires the application of appropriate statistical techniques. The use of statistical techniques which are meaningful and easily understood is important: conse quently. a discussion of the techniques used to evaluate passive dosimeters is appropriate.
There are numerous statistical tests which can be applied to both field and laboratory validation data. The main dif ference between the tw o situations is the degree of certainty of the "true" concentration of the monitored environment. In the field, the true value is usually an estimate based on the results of a standard sampling and analytical method. In the laboratory , experimental "know n"concent rations are ev olv ed and are then used for comparison with the concentrations estimated from sampling and analytical methods.
What is often not stated is that a certain amount of error also exists in the determination of laboratory-evolved "known" concentrations. These errors are often difficult to estimate. The "known"concentration is often calculated by weighing a syringe before and after an injection period (mass balance) or simply by injecting or allowing to diffuse a measured volume. It is assumed that the aliquot delivered x-as vaporized or diffused into a test chamber of known size. Possible sources of error include adsorption to or leaks from the test chamber, absorption and adsorption to articles placed in the chamber, degradation of the analyte by air oxidation or hydrolysis at high relative humidities, and error in measuring the injected contaminant. A backup monitor ing system may be used to ensure close proximity to the "known" concent rat ion. For example, an infra-red (IR)anayzer or gas chromatograph may be used as a check on a
known" concentration.
In other instances an IR analyzer or a direct reading instrument may be the only method for determining "know n"
concentrations. In this case the error in the instrument can be calculated or estimated. Charcoal tubes and critical ori fices also have been used to measure "known" concentra tions. If error in both the "known" concentration and the estimated concentration arc considered, statistical tests used to validate the experimental method become considerably more complicated: hence, the error in measuringthe"known" concentration is usually assumed to be small and unimportant.<9> Methodsdescribedabovefordeterminint the "know n" concentration vary in their accuracy, a fact which should be considered w'hen evaluating validation data for any sam pling and analytical method.
When one is validating a method in the laboratory , there are two main considerations: the variation of the samples or data points about their mean, and the deviation of the sam ple mean from thetrue mean or"known"concentration. The first consideration often is called precision and is probably the most important and reliable measure as it does not depend on the error in determining the "know n" concentra tion. Precision is estimated by determining the coefficient of variation (CV) or relative standard dev iation of the data set as follow's:
CV = -~x 100
(7)
where: $ = Standard deviation of sample data set. and X = Mean of sample data set.
Where samples are taken at several concentrations, it is necessary to determine a pooled coefficient of variation which involves determination of number of levels tested.'10' It should be noted that determining the number of concen trations (or more appropriately, the number of statistical levels) is not always straightforward. For example, if 10 samples are taken at each of three concentrations, and if within each concentration Five of the samples are collected over four hours while the other five are collected over eight hours, are there three levels or six levels? The important point to consider is w hether the differentiation of a level is based upon an anticipated difference in the sample mean. Certainly if the investigator designs the experiment with different time levels, there is an anticipated effect of time on the mean. Unfortunately, when experiments are so designed, statistical analyses at the various levels usually are not performed.
The second statistical consideration, the difference between the sample mean and the "known" value, is sometimes called accuracy, but the term bias is more appropriate. It is defined as:
b = X ~ Xo X 100 Xo
(8)
where: X = mean of sample data set, and Xo -- "known" value at level tested.
If more than one level is sampled, it is necessary to determine the pooled bias of the data set.111'
3H 002089$08
Am ind Hye Assoc J (43)
August, 198?
The bias for a given set of data can sometimes be cor rected. If the average bias (either the average of several samples at one level or the pooled bias for several levels) is large, one should note if the components of the bias value (either the individual samples or the levels) are consistently negative or positive. If the bias is large and varies consis tently in one direction, the precision nevertheless may be quite small. In this case a physical or chemical variable may be consistently affecting the method (a systematic as opposed to random error), causing the experimental values to con stantly fall short or long of the"known"concentration. This form of bias should be corrected.
In addition to these statistical tests, others have been used to assess the validity of passive monitoring systems. Overall system accuracym, has been defined as (2 X CV) + absolute bias, expressed as a percent. Others"2' have used the percent age of the "known" concentration accounted for by the sample mean two standard dev iations as well as the term systematic error"3,1" which is equivalent to overall system accuracy. Relative standard deviation has also been used, and is defined as the equivalent of CV."S' Additionally, some authors report only raw data while others report means without standard deviations or sample sizes, and various other combinations. While all of these statistical determina tions have utility, it seems important for comparative pur poses to consistently use those determinations w hich give the most information in the simplest form. Certainly, bias and precision meet these criteria.
Discussion of one other point seems necessary. NIOSH1"" has proposed as a guideline for their own internal purposes that sampling and analytical methods meet a minimum requirement of 25 percent accuracy; that is. the absolute total error of the method should be less than 25 percent in at least 95 percent of the sample population (assuming a nor mal distribution). NIOSH derives the maximum precision value for an unbiased method given the accuracy criteria stated. This value (12.8 percent) is the maximum precision value acceptable for an unbiased method. Although the 25 percent accuracy criterion has been criticized by some authors.'16' it wasadopted for N'lOSH's own internal useand is not meant as public policy. However. OSH A adopted the same criterion for the benzene standard, w ithout a complete derivation or explanation. Consequently, this criterion has been criticized and alternatives have been proposed.'17' A second important point is that bias is also considered in the 25 percent criterion according to a somewhat complex statistical relationship."0' but the overall system accuracy as defined earlier"" is a fair approximation if the method has a true bias, i.e., its mean is statistically different from the "known concentration." A final point is that as the number of samples at a level increases, the standard dev iation and CV should decrease. These considerations are important w hen evaluating passive monitor validation data, especially in those cases where manufacturers have stated that they have met the 25 percent accuracy criterion.
For field comparisons of conventional and passive moni tors. different statistical tests are necessary. If passive moni tor values, for example, are plotted against charcoal tube
results (Y vs. X) and more than one concentration is sampled, one would expect an increase in X to cause an increase in Y. If the increase is linear, and the sample values lie on the regression line, the correlation coefficient (r) would have a value of one. If a change in X brings about an equal change in Y, then the slope would also have a value of one. If the individual values for the two devices are indeed equiva lent. the line should intercept the origin. Each of these rela tionships is expected within reason. The difference of the slop from one. the correlation coefficient from one, and the intercept from zero can and should be tested.
In order to perform the regression analysis described above we must assume that X (active sampling data) is not subject to error. Of course, we know and can calculate under laboratory conditions the error of active sampling systems. There are at least three reasons why this error is oltcn overlooked. First, it is assumed that consideration of the error in X would only cause small differences in regression analysis results. Second, in addition to laboratory demon strated error, a range of errors introduced by varying envi ronmental conditions must be considered. While difficult to assess, these errors may have a profound effect on X. and indeed the error in the X measurement may be as great or greater than that for Y, Finally, if the error in X is to be considered the statistical tests are complex. Such tests have been discussed for biological problems;"6' however, the the ories apparently have not been applied to sampling and analytical methods even though their appropriateness has been recognized."9'
applications
From a historical vantage, one of the earliest reports of a "passive" monitor for evaluation of airborne contaminants was patented by Gordon and Lowe in 1927.<20' Their gas detector for carbon monoxide involv ed an "easily frangible vessel containing a solution of salts including palladium chloride, and a covering for said vessel of a light colored absorbent material." The principle involved breaking the vessel (a small ampule) and noting the subsequent color change of the solution as it reacted with the carbon monox ide on the light colored absorbent material. This type of semiquantitative dev ice was certainly a forerunner of those that are available today, though it was undoubtedly affected by air velocity as a stagnant air layer was not employed.
An extension of Gordon and Lowe's concepts in the late I960's provided the basis for Plantz et at. to develop a personal dosimeter for measuring hydrazine, unsymmetrical dimethylhydrazine and monomethylhydrazine.'2" The reac tion of these compounds with a "colorimetric substance" (bindone) produced a purple color, the intensity of which was dependent on both concentration and duration of expo sure. Color standards then were used to estimate the concen tration as a function of the time the badge was exposed to the contaminated air; consequently, the method was only semi quantitative. In considering sources of error the authors noted that the purple color would also be produced by all volatile bases that were tested, including ammonia, aliphatic amines, aniline and cigarette smoke.
American Industrial Hygiene Association JOURNAt
(43) 8'82
3M 002090
609
Of interest in this review, however, are quantitative devices based on the principle of either gas or vapor diffu sion or permeation through a stagnant air layer. The first such dev ice to be reported in the literature was described by Palmesand Gunnison in 1973.<22'Their device employed the principle of gas diffusion to determine airborne concentra tions of sulfur dioxide and w ill receive further consideration subsequently. To gain the best overview of the v arious appli cations of these concepts, it is probably best to proceed by considering first the inorganic and then organic gases and vapors.
inorganic gases and vapors
ammonia
In 1978. Ma/ur et al. described the use of the Abcor GASBADGE to sample employee exposure to ammonia (this device currently is not marketed).12'" The investigators replaced thecharcoal pad normally found in the GASBADGE with an acid impregnated absorption pad. Of three acids tested, phosphoric was most successful in prov iding the best approximation of theoretical concentrations. They deter mined. however, that volatile amines, specifically cyclohexylamine. could produce high readings, as high as 185 percent of the synthetic atmosphere. This led them to replace the glass fiberdraft shield on the front of the GASBADGE with a "charcoal impregnated glass fiber filter which had been pretreated with alcoholic KOH containing 0.1 percent sur factant." The charcoal served to adsorb amines as they dif fused into the dosimeter, while the KOH (aided by the welting agent) eliminated irreversible ammonia adsorption by the charcoal, w hich would hav e caused underestimation of the ambient concentration. Additional laboratory exper iments demonstrated that storage time of up to 47 days, prior to analysis, did not appear to adversely affect the results.
More recently. DuPont has developed a commercially available system for the measurement of several airborne contaminants including ammonia. In 1981. Kring et al. described DuPont's PRO-TEKTMsystem forammonia. nitro gen dioxide and sulfur dioxide sampling analysis using a col orimetric readout instrument.<J4' The ammonia badge relies on molecular diffusion of ammonia and subsequent chemical reaction w ith a solution of0.3N boric acid and0.03N sodium potassium tartarate (sic). After exposure, the reagent pack is removed from the badge holder and analysis is initiated by pressing reagent "blisters" w hich are adjacent to the absorb ing solution. This action causes the release of a modified Nessler's reagent and the subsequent development of a colored solution. For ammonia, maximum color intensity is developed at 425 nanometers. The absorbance of the sample is then compared against a standard curve based on Beer's Law. After determination of the precision of the analytical method and verification of the linear range of the color chemistry, laboratory testing was conducted to establish the operational range as well as precision and accuracy of the overall method (see Table I). The minumum and maximum limits of the sampling range were found to be 50 and 500 ppm-hours. respectively. For an eight-hour time weighted average, these values correspond to one-fourth and two and
one-half times the current ACGIH Threshold Limit Value of 25 parts per million.12*11 In considering sources of error, environmental effects including temperature (10 to 40 C). relative humidity (10 to 80 percent), pressure(730 to 790 mm Hg). and face velocity (2.5 to 125 cm sec) were included. Of the environmental factors evaluated, temperature and the concentration of the contaminant were identified as being responsible for 98 percent of the data variation. For ammo nia, a temperature correction factor of 0.6 percent per degree centigrade was suggested. Also investigated was the storage stability of both unexposed and exposed badges. Results indicated that refrigerated storage is necessary to extend the shelf life of unexposed badges. Once the badge isexposed to ammonia and before the reagents arc mixed, the badges can be stored for one (room temperature) to three (refrigerated) weeks without losing any absorbed contaminant. Once the reagents are mixed and color formation is started, the badge should be read w it hi n 90 minutes. Additional testing results conducted by DuPont are shown in Table I.'26'
carbon monoxide
Shor and Anders, of the 3M Company , have described the 3M "direct-read diffusional monitor" for evaluation of exposures to carbon monoxide.'2'1 The principle involves the reaction of the carbon monoxide and an unreponed reagent(s) to give a visible color change from pink to tan. Theoretically, "if any pink color is observable at the end of the exposure period, then the exposure was less than the one time-weighted-average of 400 ppm-hours." They also state that noting the time to the endpoint allows for calculation of the average concentration of carbon monoxide during the exposure period. The authors present summary results of laboratory evaluations using an infrared radiation device to establish "known" concentrations (see Table I),
chlorine
Hardy et al. have described a personal chlorine monitor (REAL. Inc.) which employs the principle of permeation of the gaseous contaminant through a silicone membrane and into 10 mL of a fluorescein-bromide solution.'26' Colorimet ric techniques then can be applied to determine the chlorine concentration. The authors report a detection limit of 0.013 ppm chlorine for an eight-hour exposure, w ith a "working range" of 0.1 to 2.0 ppm. They also suggest that for shorter time periods, concentrations of up to five ppm can be deter mined. Other observations included effects of temperature, humidity, absorbent concentration. pH and response time, with all laboratory results presented graphically.
Moleculon Research Corporation has recently introduced a chlorine monitoring device which relies on plastic film impregnated with liquid reagents.'29* Exposure of the badge to chlorine gas gives a visible, "blue-purple." color change. Optical transmission measurements, and comparison with a standard curve, can then provide quantitative exposures in ppm-hours. The manufacturer's summary results indicating effects of temperature, humidity, w ind velocity and concen tration are reported as presenting an error at the 95 percent confidence level, which is "less than 15 percent."
3M 00209110
Arr Ind Hy Assoc J (43)
August 198?
Chemical
TABLE I
Inorganic Gases and Vapors Laboratory Results
O timeter* BieK Precisi nr
Range"(ppm)
Reference
Note*
Ammonia
Nitrogen Dioxide
Sulfur Dioxide
Hydrogen Sulfide Mercury
CO
DP DP GB
GB DP DP MDA
GB DP DP
GB
3M 3M
3M
05 0.5 -3.2
-3.2 -0.9 -4 9
-1 -08
OS 17
0.3
7.4 69 9.3
21.7 7.5 87 41
13.8 58 75
15.3
9 2
47
20-50 20-48
6-62
4-11 4-11 4-11 6-9
4 6-5 3 4-11 4-11
1 6-2.2
0.03-0.3mg/m' 0.05-0.2mg/m`
50-1830
24 26 23
1 38 24 36
1 38 24
1
32 33
27
rc
MI
Kr. H1
HI K
t:<;
r.
'DP-DuPont Pro-Tek Colorimetric System Badges. 3M=3M Company Monitor. MDA=MDA Scientific. GB=Abcor GASBADGE "See text, equation (8) ` See text, equation (7) "Some values are rounded to nearest whole number ''Bias consistently negative ''Results derived from Table III of McCammon ef al.`u' ``Results calculated from data provided in reference "This product is not currently marketed 'Bias could not be calculated from data given
hydrogen sulfide
In 1977. Tompkins and Goldsmith described the development of the GASBADGE personal sampler.'" Although later work with this device focused on the collection of organics on an activated charcoal substrate, initial studies researched sampling of both organic and inorganic com pounds. (The GASBADGE for organic \apors is now mar keted by National Mine Safety Company, and those for inorganic vapors are not currently marketed.) Applications involving inorganic gases relied on collective elements of an "appropriate substrate impregnated with a chemical medium specific for the contaminant of interest." Based on 60 obser vations. the authors' statistical summary is presented in Table 1. Eighty percent of the measurements were w ithin 25 percent of the "true" value. Challenge concentrations were established in a "well-mixed" environmental test chamber and were measured with an "independent wetchemistry sampling train."
Hardy and associates hate described a permeation device (REAL. Inc.) which relies on the permeation of HzS through a dimethyl silicone membrane and subsequent reaction w ith a solution of 0.2N sodium hydroxide and EDTA.<30' The colored product (methylene blue) is measured spectrophotometrically and compared with a calibration curve to determine ppm-hours. A knowledge of exposure time then allows for the determination of average exposure over the measurement period. The authors note that a critical step in
the development of such a device is the experimental deter mination of the permeation constant (see Equation 6). w hich involves calibration of each monitor by exposure to known concentrations of the contaminant. The results of this labo ratory research demonstrated a detection limit of 0.01 ppm for an eight-hour exposure, with a w orking range ol 0.1 to 20 ppm and a linear response up to 200 ppm. The working range corresponds to one one-hundredth to two times the current eight-hour TLV of 10 ppm.'25' Evaluations ol en\ ironmental effects indicated that neither temperature, over the range of --3 to39C. nor humidity, from 0 to 99 percent relative, caused any significant variations in response of the device. Further research demonstrated a good response to high concentrations in less than one minute, adequate sam ple stability up to 10 days if EDTA is used in the absorbing solution, and negative and positive interferences, respec tively, from chlorine gas and nitrogen dioxide. Precision and bias were not reported.
Another approach for the determination of gaseous hydro gen sulfide has been reported by Gracdel and Franey.'31' Their research involved using a semiquantitativc method without a stagnant air layer and relying on the discoloration of lead-stabilized polyvinyl chloride (PVC). The technique involves the diffusion of gas in a polymer and. at high HsS levels, the detection rather than the measurement of toxic levels of H2S. Screening applications for low level exposures also are discussed.
American Industrial Hygiene Association JOURNAL
(43) 8 82
3M 0Q2G92
611
mercury
In 1977. McCammon and Woodfin of N IOSH reported the results of a laboratory evaluation of 3M's mercury vapor monitor.'32' The monitor's operating principle involves molec ular diffusion and deposition of mercury vapor on a gold substrate. The resulting change in electrical conductivity across the gold foil is related to the amount of mercury absorbed by the foil. Three other sampling methods, all of which involved the active movement of air. also were inves tigated and include the LASL tandum sampling tube, the hopcalite tube, and the iodine impregnated charcoal tube. For the passive monitor, precision and accuracy, the effects of face velocity and temperature, and potential interferences were investigated. Concentrations of mercury vapor in an exposure chamber were monitored with an ultraviolet mer cury vapor meter, which in turn was calibrated by measure ments using the LASL method. To determine precision of the monitors. 12 devices were exposed to a test atmosphere. Results from th/ec measurements of the test atmosphere using the LASL method gave an "expected" concentration of 0.056 milligrams of mercury per cubic meter of air (mg m3). with a standard deviation (SD) of 0.002 mg m3 and a coefficient of variation (CV) of 0.037. Precision and bias calculated for the data given in Table 111 of McCammon ei ft/.*32' is summarized in Table I. A least squares regression analysis of the combined precision and accuracy results for the passive dosimeters versus the "known" concentrations gave a Y intercept of --0.004 mg m3 and a slope of 1.003. Tests for the effects of face velocities from 25 to 125 cm sec (50 to 250 fpm) did not appear to have any adverse effect on performance, while variation of temperature experimentally confirmed its effect on both the diffusion constant and the concentration of the contaminant. The potential effects of changes in relative humidity were not discussed by the authors. The other area of investigation in this study involved potential interferences of chlorine, sulfur dioxide, and hydrogen sulfide. Concomitant and sequential exposure to mercury and chlorine, the latter at high levels (5.8 ppm), produced a negative bias, but a similar effect was observed with the UV meter and the LASL system. The authors suggested that the mercury and chlorine may have been reacting to form mercuric chloride which was not being measured by any of the systems. The interference effects of sulfurdioxideand hydrogen sulfide, although less thanchlorine. also were confirmed.
In 1980. McCammon and his NIOSH and OSHA coworkers conducted further tests of the four previously described mercury vapor sampling and analytical methods.*33' The design of this laboratory experiment involved inter comparison of four methods, and the findings suggested that the variability of the iodine charcoal tube method is signifi cantly different from that of the other three methods. It was observed that the other three methods, including the 3M passive dosimeter, exhibited good precision over the concen tration range of 0.05 to 0.2 mg. m3 as shown in Table 1.
Recently SKC, Inc., introduced a gas monitoring badge (produced by GMD, Inc.) w hich uses the principle of molec ular diffusion (without a stagnant air layer) to collect mer
cury vapor.'34' The sampling media is referred to as "Hydrar Sorbent,"and "extensive"but unpublished field and labora tory testing arc cited to show that "chlorine, moisture, etc., do not interfere" with measurements. HYDRAR is devel oped from a "manganese dioxide catalyst material similar to `Hopcalite.' " Quantitative determination is made by chemical desorption of the mercury and analysis with atomic absorption.
nitrogen dioxide
In 1976, Palmes era/, reported the results of their evaluation of a personal sampler for nitrogen dioxide (N02).'35' This work was an extension of their earlier pioneering efforts in developing a personal sampler, employing the principle of gas diffusion, for sulfur dioxide.'22' In their design, the sam pling device was a 1.3 cm (0.5 inches) acrylic tube. 7.1 cm (2.8 inches) long. At the "closed "end of the diffusion path (tube) were placed three stainless steel grids coated with triethano lamine (TEA). TEA was selected because: I) it captures NO* efficiently, 2) it provides a stable sampling surface, and 3) it yields a chemical complex with NOa that is very stable ov er time. Subsequent analysis yielded a colored complex w hose absorption was measured at 540 nanometers. Results were then compared against a standard curve which obeyed Beer's Law. The experimental evaluation of the NO2 sampler involved chamber measurements compared with "known" values determined by the volume of NO2 introduced to the chamber or the weight loss of NO2 from a permeation tube. Although neither individual nor summary results were pre sented. graphical comparison of the data indicated a close agreement between the passive sampler results and theoreti cal concentrations. The effects of wind velocity and direction as well as stability over time also were considered. In deter mining w ind effects, the uptake of water vapor, rather than NO2. was measured. The results indicated that there was an increase in average uptake with increased velocity and that the 45 degree incident angle gave the highest uptake (135 percent at 258 cm sec). Across all angles of exposure (0 to 180 degrees) the average uptake increased from 2 to 14 percent as the w ind velocity increased from 50 to 258 cm sec (100 to 516 fpm). Stability studies indicated that the badges could be used for months both after preparation and before exposure as well as after exposure and before analysis.
In the previously described studies with theGASBADGE. Tompkins and Goldsmith also monitored for nitrogen diox ide."' Their summary results for 82 observations showed accuracies and precisions as summarized in Table I. Eightyfive percent of the observations were within 25 percent of the "true" value.
A commercial model of the Palmes passive sampler has been marketed by MDA Scientific. Inc., and additional laboratory testing demonstrated a linear collection effi ciency for any given dose, i.e., concentration X time (see Table l).'36' The sampler exhibited a consistently negative bias as compared to concentration determinations using a continuous monitor and the NIOSH wet chemical method.
As noted earlier, the DuPont PRO-TEK system includes a badge for nitrogen dioxide. Laboratory test results of this dev ice are show n in Table l.'3*'
3H 002093`>12
Am Ind Hye Assoc J(431
August 19E?
sulfur dioxide
As noted previously, pioneering work in 1973 on the design of a sampling device which relics solely on diffusion of gaseous contaminants through a stagnant air layer is attrib uted to Palmes and Gunnison.1221 Their initial studies involved experimental work on different tube lengths. The collecting medium was a complex of mercuric chloride and the final analysis involved colorimetric determination. The studies demonstrated that, except for very short diffusion paths (tube lengths), the diffusion monitor satisfactorily duplicated the results obtained by both wet chemical and conductrimetric measurements. Although this study did not go into the ramifications of environmental effects and inter ferences. it should be recogni7ed as an important step in developing a new industrial hygiene technology.
The last of the three inorganic gases looked at byTompkins and Goldsmith in their studies of the GAS BADGE
was sulfur dioxide.01 Summary data for 23 observations on this gas are included in Table I. One hundred percent of the observations were within 25 percent of the "true" values.
The results from DuPont's tests on their sulfur dioxide badge also are shown in Table I.t38)
organic gases and vapors Most passive dosimeters designed to sample for organic gases and vapors use activated charcoal as the adsorbing medium. As we know from its extensive use in active sys tems. activated charcoal has an affinity for a wide range of organic compounds. Consequently, the discussion on the applications of passive dosimeters for the measurement of organic gases and vapors first will focus on devices using activated charcoal and then will turn to specific organics which rely on other collecting media.
Chemical
TABLE It Organic Gases and Vapors Laboratory Results
DosimeterA Bias"
Precisionr Range11 (ppm) Reference
Notes
Carbon Tetrachloride Toluene
Formaldehyde Benzene
Ethylene Oxide Halothane Enflurane Acrylonitrile Hexane Vinyl Chloride Methyl Chloroform
Trichloroethyiene
DPA DPA NMS DP DPB NMS NMS
3M 3M 3M NMS NMS
R 3M DPA NMS 3M DPA NMS
0.4
0.3 -- 1.7
V5 3.3 -4 1 1.8
-1.4 3
-2.8 0.03
-1.2
-0.2 -5.9 -10.6
2.4 -3.9 -6.9 -0.5
4.4 5.25 1.7 63 4.7 1.7 17
3.2 7.4 4.8 8.7 2
37 47 4.5
2
7.6 7.7 1.9
3-18 57-228 12-47 0.2-4.2
3-24 0.8-54 13-13.5
300 0.5-20 0.5-20 0.7-19 10-37
1.5-14 160 840 160-840
15-65 20-200 20-200 15-67
10 E
45 13 FJ
55
46 13 FJ
1 E.GJ
53 J 44 4 44 4
39 13 FJ
2 HJ
48 u 48 EU 12 FJ 48 IJ 48 E1J 12 FJ
A3M = 3M Company Organic Vapor Monitor. DPA and DPB -- DuPont PRO-TEK G-AA and G-BB Organic Vapor Badges. NMS = National Mine Safety GASBADGE.R = Real. Inc. MINIMONITOR, DP = DuPont PRO-TEK System Colorimetric Badges BSee tew. equation (8)
cSee tew, equation (7) DSome values are rounded to nearest whole number ESmal( sample size "Knowns were calculated using charcoal tubes with critical orifices. This could affect the
bias measure. "preliminary results "Permeation dosimeter 'Bias consistently negative JResulls calculated from data provided in reference
Amencan Industnal Hygiene Association JOURNAL
(43) S 82
3M 002094
613
activated charcoal devices
As of March. 1982. there were four manufacturers of passive dosimeters which rely on diffusion and subsequent adsorp tion on to activated charcoal: National Mine Service Com pany (GASBADGE). 3M Company (Organic Vapor Moni tor). DuPont Company (PRO-TEK. G-AA and G-BB Organic Vapor Air Monitoring Badge), and the Mine Safety Appliance Company (Vaporgard Badge).
In 1977. Tompkins and Goldsmith described the first commercial passive dosimeter for monitoring organic vapors.11'The GASBADGE relied on moleculardiffusion of the vapor into the badge and subsequent adsorption onto activated charcoal. The authors developed the theoretical principles of the badge's operation, and discussed sensitivity to temperature and pressure, face velocity effects, and response time. Preliminary results showing the badge's response to benzene, ethyl acetate, methyl ethyl ketone, and styrene also were presented and were described as "very encouraging" (see Table II).
In the same year. Silverstein reported results of laboratory . id field testing of the GASBADGE for aery lonit rile.The
suits of the exposure of 33 bodges to known coneentraons in the laboratory are presented in Table II. The results idicate the acceptability of the GASBADGE for measureents of acry lonitrile over the range of 0.75 to 19 ppm. The ; me of exposure in the laboratory was not given, however, eld measurements did cover periods of up to seven hours. Ithough temperature and relative humidity ranges were ported, data analysis to determine the effects of these ariables was not presented. Silverstein also looked at -'sorption efficiencies and determined that the best results >4 percent) were obtained with four mL of two percent etone in carbon disulfide.
In 1978. Bamberger ei at. conducted a series of laboratory sts to ev aluate the GASBADGE.'1"1' Their approach inv olved ic generation of known concentrations of solvents and ibsequent evaluation with charcoal tubes (active sampling) nd the passive dosimeter. To evaluate the applicability of he dosimeter over a wide ranee of compounds, the investiation included seven different organic compounds each .presentative of a different functional group. Included in this study were: ben/ene (aromatic), n-butanol (alcohol), n-butyl acetate (ester), isooctane (alkane), methyl chloro1 orm (halogenated alkane), methyl isobutyl kctone(ketone). nd trichloroethylene (halogenaied alkene). The diffusion oefficient (D) used was that supplied by the badge manufacirer, except in the case of isooctane which was reported as aving an unknown coefficient. Computations involving this compound relied on the coefficient for n-octane. A variety of experiments wasconducted to look at a wide range of questions. Their findings corroborated dosimeter con cerns similar to those of active systems using charcoal tubes. e.g.. minimum and maximum loadings are important, postample contamination and loss can occur if the exposed bsorbent is not adequately sealed, percent recovery for fixtures is consistent with percent recoveries for single compounds, and differences in charcoal lots can give differnt results. Other tests confirmed the need for some air
movement across the badge lace and the lack ol clleet ol temperature changes over a small range! 11 W'C ) t he results of the simultaneous sampling with the badges and the char coal tubes indicated that the badges had a consistent nega tive bias. The authors suggested that, because the results were so reproducible, corrections lor adsorption desorption efficiencies less than 100 percent can be accomplished just as is done for charcoal tube data.
In 1979, Hirayama and Ikeda evaluated theapplication ol the GASBADGE lor monitoring exposures to mixed sol vents.'"" Their research involved different preparations ol activated carbon "felt" in place ol the supplied collection medium and exposure to mixtures of n-hexane. ethyl acetate and toluene. Summary (graphical) data indicated that the amounts of contaminant absorbed by the dosimeter were proportional to both the vapor concentrations and time of exposure.
Halliday and Anderson reported on the use ol the GASBADGE in monitoring lor halothane ,l" Six observa tions indicated a range of measurements Irom minus nine to plus ten percent of the test atmospheres. I'nlortunately. the authors did not report their procedure for determining the concentration of halothane in the test atmospheres.
In 1981. Evans and Horstman reported evaluations of desorption efficiencies of charcoal tubesand the GASBADGE for styrene.1*'1 For liquid dosing they found the dosimeter to be similar to the tube, while for vapor dosing the badge was superior. The authors suggested that the differences in results may. have been related to the use of coconut shell carbon in the tubes and petroleum derived carbon in the badge. They did not explain why this difference would affect one method of dosing and not the other.
In 1980. Anders and Mullins of the 3M Company pre sented results comparing the 3M passive monitor with char coal tubes in sampling lor mixtures of organic compounds.1 Wl The laboratory tests included a binary mixture of toluene and methyl ethyl ketone: a tertiary mixture of ben/ene. toluene and xy lene: and complex mixtures of unleaded and leaded gasoline containing various alcohols. Although the investigators cited "excellent" precision and accuracy for the dilfusional monitor, sample sizes were small, and the com plicated study design and lack of raw data preclude the determination of precision and bias statistics.
Ma/ur and his co-workers'141 conducted side-by-side laboratory and field tests with charcoal tubes and 3M organic vapor monitors to measure concentrations of halo thane (2-bromo-2*chloro-l.l.l-trifluoroethane) and enflurane (2-chloro-l.l,2-trifluoroethyl difiuoromethyl ether). The results of the laboratory studies are presented in Table II and support the authors' conclusions that the dosimeters are a reliable method for the collection of enflurane and halothane.
In 1980, Lautcnberger et al. described DuPont's passive monitor for organic vapors.'11' Each charcoal strip in the PRO-TEK G-AA Organic Vapor Badge contains approxi mately 300 mg of coconut-based activated charcoal impreg nated in an inert polymer. A dual sampling rate of approxi-
!4
Am ln<j Hyg Assoc J (13)
August 1982
3H 002095
mutely 5() or 100 ml min i\ determined by the removal of one or both of the dosimeter's protective covers One aspect ol their research inv olved experimental determination of the dillusion eoelTieient of several gases and vapors They reported that values calculated by I net: were within 10 percent of their experimentally determined dillusion coctlieicnl values. Preliminary experimental results were used to discuss lace velocity el feet s. range and sensitiv ity , maximum and minimum sampling times, vapor retention, storage sta bility. desorption ellicienev, and overall badge elliciency. I he overall accuracy determinations were limited to four observations at each of two concentrations of carbon tetrachloride (see Table III. However, the presentation of raw data, as well as an explanation of the statistical tests applied, is most useful. This same detail of information is also lound in DuPont's validation reports for toluene and ben/ene (see Table 111.'''
In the ben/ene report. DuPont also describes us PRO-TEK G-BB badge. This badge has a backup section ol charcoal, which serves the same purpose as the second section in a charcoal tube. i.t\. to aid in determining it the sampler has been overloaded. I he 3M Company also markets an Organic Vapor Monitor with a backup section.'1''
In studies of the measurement of waste anesthetic gases with passive dosimeters. Jonas el at. evaluated the GASBADGE, 3M Organic Vapor Monitor and DuPont Pro-Tek in measuringenfluranc.'hl Unfortunately, the badges were not identified in the presentation ol the results although interpretation of the reported samplergeometry would indi cate that A was the DuPont badge. B was the 3M badge, and C was the GASBADGE. The results of their laboratory studies indicated that badge B had the lowest coefficients of variation (CV was not calculated as described in this text)as compared to concentrations determined by infrared analy sis, Badge A had a low CV (9 percent) at 5 ppm and a much higher value (CV=34 percent) at 20 ppm. The C badge had consistently high CV's ranging from 23 to 30 percent. It should also be noted that the charcoal tube CV's ranged from II to 27 percent, that desorption efficiencies for the badges ranged from 0.81 to 1.17. and that IR analyses of tank concentrations were constantly lower than expected. If badge B was the 3M device, the results of Jonas el at. support those reported by Ma/ur el at.' Further testing of badges A and C seems necessary, however, to confirm their seemingly low precisions.
Mazur and his coworkers conducted additional tests comparing the 3M and DuPont badges against charcoal iubes.H<?' Methyl chloroform and trichloroethylene, two sol vents widely used in vapor degreasing operations, were sampled. In the laboratory phase of the study, the badges and charcoal tubes were exposed to chamber concentrations over the range of 160 to 840 ppm of methyl chloroform and from 20 to 200 ppm of trichloroethylene. Exposure times varied from two to six hours for methyl chloroform and from four to six hours for trichloroethylene. The laboratory work indicated that the percent recoveries of the various doses (concentration X time) were in good agreement except for one exposure of the 3M badge which involved a five hour
ViTwcan Industrial Hygiene Association JOURNAL
MJl 8 82
exposure at 700 ppm. I he authors noted that this exposure ol 3500 ppm-hours exceeded the upper exposure limit pro vided by the manufacturer. The overall mean recovery value lor each type ol sampler was used to correct all subsequent lield data. In addition to the recovery measurements, the laboratory phase ol this study also involved determination of storage stability. The authors found no significant losses of methy I chloroform or trichloroethylene Irom either badge following storage of exposed badges for up to three weeks.
In 1978, West and Reis/ner reported on the lield tests of the MIMMOMTOR'" (REAL, Inc.) permeation personal monitor lor vinyl chloride.'"1 This monitor was a modified version of one previously described by Nelms ei at."*' 1 he collecting medium was activated charcoal, but rather than relying on molecular diffusion, the badge design involved a polymeric membrane and the permeation of vinyl chloride through the membrane and adsorption onto the charcoal. Initial laboratory calibration was used to determine the permeation constant of the dev ice. l aboratory results indi cated good accuracies as summarized in Table II.
During the same period that Tompkins and Goldsmith" were describing the GASBADGE. Bailey and HollingdaleSmith of Great Britain were presenting their ideas for a personal passive sampler lor organic gases and vapors. Their design involved the use of either one of two types of membrane and subsequent adsorption onto activated char coal. They found two membranes to be satisfactory: one of thin silicone rubber w hieh acted as a permeation barrier, and the second a porous polypropylene film which allowed tor molecular diffusion of the gas and vapor. They conducted laboratory tests using carbon tetrachloride, styrene and dichlorodifluormethane. Their test results do mix some ter minology. e.g.. permeation rates for both the permeation device and the diffusional device, but did provide an early demonstration of the feasibility of such a device for monitor ing certain organics. The device, the Porton Diffusion Sampler, seems to see its greatest use in Great Britain.
acrylonitrile
One ofthe newest applications of passive dosimetry involves the use of a porous polymer (Porapak N) as the collecting surface with subsequent thermal desorption and gas chro matographic analysis. Benson and Boyce have described such a device and its utility in sampling for acrylonitrile.'''" Laboratory testing for acrylonitrile involved comparison of the dosimeter values with concentrations measured on a gas chromatograph. Initial experimentation indicated that the dosimeter can be used for acrylonitrile concentrations in the range of 4 ppm. but at concentrations of 2 ppm a 40 percent error is reported.
aniline
In addition to activated charcoal, another widely used adsorbent medium is silica gel. To study the utility of this material. Campbell and Kon/en constructed passive dosim eters from glass culture tubes (1.05 cm inside diameter) with 40 60 mesh silica gel as thecollectingsurface.'5'1 Laboratory testing involved exposure of the dosimeter to aniline, with exposure concentrations determined by gas chromato graphic analysis of ethanol gas scrubbers. Three different
3M 002096
61S
size (length) dosimeters were evaluated, w ith the best results obtained with the intermediate length tube( L = 3.0cm: A L = 0.3 cm). The authors present raw data and clearly described their statistical techniques.
ethylene oxide
Mullins and Anders have recently described the 3M diffusional monitor for sampling ethylene oxide in air.'53' In this badge the collecting surface is described as a "chemically impregnated charcoal surface, (where) a reaction occurs producing a stable compound with a vapor pressure sub stantially lower than the parent compound." The authors present statistically summarized data describing the linearity and capacity of the monitor, the recovery of absorbed ethyl ene oxide, environmental effects, sample stability, and the effects of potential interferences. Precision and bias are presented in Table II.
formaldeh yde Rodriguez el at. have described another 3M diffusional monitor for sampling formaldehyde/541 In this diffusional monitor, the collecting surface is an "impregnated sorbent" which can then be desorbed in sim with water and the concentration of formaldehyde determined colori metrically. Laboratory ev aluation first inv olv ed determination of recov ery coefficients, which at eight ppm-hours (19.5 micrograms) were found to be 1.00 0.04 over six tests. The next step involved determination of the dosimeter's "sampling rate"(DA' 1.) by exposing the dosimeters to "known"con centrations of formaldehyde as generated by a permeation tube. The effect of relative humidity on the sampling rate also was investigated, and evaluation of the data did not indicate any statistically significant differences between the rates at 50 and 85 percent relative humidity. The study protocol then inv olved simultaneous exposures of impingers (modified chromotropic acid method) and dosimeters. The authors concluded that "the measured values by both methods lie within 25 percent of the expected response" and that "less variation is observed in the monitors than in the impingers." However, neither precision nor bias were reported. The authors also investigated effects of storage and determined that at elevated temperatures (38 C) losses up to 11 percent occurred after one week, however no signif icant loss was seen for samples stored at 23 C. The authors briefly discussed the potential for a negative interference from phenol and described the use of modified calibration curves to address this problem.
DuPont's PRO-TEK series of colorimetric Air Monitor ing Badges, includes a badge for formaldehyde. The collec tion principle involves a chromotropic acid-sulfuric acid reaction. Laboratory evaluation (42 samples) of the dev ice at seven exposure levels revealed results as shown in Table II/55' Additional studies also were conducted on tempera ture and storage effects. The raw data and statistical analysis procedures arc presented.
Kriesel'5'has described a new passive dosimeter for form aldehyde which is a modified version of the Palmes tube. At the present time experimental data concerning this dev ice arc not available.
phosgene
Matherne er at. have recently described the GMD. Inc. "passivedosimeter"which provides a semiquantitativc mea surement of phosgene exposure/57' The badge involves direct contact between the contaminated air and a chemi cally impregnated tape and therefore does not rely on a stagnant air layer. The treated paper stain intensity is reported to be logarithmically proportional to the phosgene dose overa range of 2 to 100 ppm-minutes. For quantitative measurements the badges can be read colorimetrically.
other methods
Hill and Fraser have described the use of commercial detec tor tubes modified to act as passive dosimeters/55' In their research, common length-of-stain detector tubes were modi fied by cutting off the conical end of the tube and remov ing some ofthe indicator column material. This leavesan orifice w ith a cross-sectional area equal to that of the inside ol the tube and a path length determined by the distance from the end of the tube, to the beginning of the indicator material. One would expect, however, that as the sorbent material becomes exposed, i.e., the length of stain increases, the diffusion path length willalso increase, thereby changing the sampling rate. Their evaluation of these devices involved separate laboratory exposures to toluene, ethanol and iso propanol. The results of their w ork. although presented only in graphical summary, demonstrate the potential for the use of modified commercial detector tubes as passive dosimeters.
field validation
Relatively few studies have been published in which passive dosimeters have been compared side by side with charcoal tubes or other conventional sampling methods under actual field conditions. For inorganic compounds only two stud ies. involving nitrogen dioxide'59' and chlorine.'"'" have been identified. For organic compounds, eight stud ies'9,9 39 44`4S`51'6t'S1' have involved field comparisons, with the number of compounds per study ranging from one to 22 In three of these studies, statistical analyses of data were not presented and cannot be performed because of small sample size or insufficient presentation of data.
Jones et o//59' conducted a field evaluation for NO_> in a salt mine, which contained diesel equipment as the NO.source. At each of 16 different fixed area locations, two Palmes dosimeters and two TEA tubes with pumps were used to sample theatmosphere. Theactive sampling (pump) method gave a coefficient of variation (CV) of 8.7 percent while for passive tubes the CV was 5.8 percent. Regression analysis (where the active system was the X variable) of their data gives a correlation coefficient of 0.69, a slope of 0.59. and an intercept of 2.05 ppm for data over the range of 3.7 to 5.5 ppm as sampled by the active method. This indicates that the dosimeter gave consistently higher readings which is reflected in the means for the two methods: 4.51 ppm for passive and 4.14 ppm for active sampling. The authors did not report wind velocities, but low velocities, as would be expected with area samples, should have caused passive
816
Am Ind Hyi Assoc J (43>
AJfU5` \9cl
3M 002097
values to be low as compared to active values; this was not the case. On the other hand, high face velocities could have led to the observed positive (passive versus active) bias.
Hardy et al.,iB) reported the raw' data results from a Held evaluation of a permeation chlorine monitor (REAL. Inc.). Thirteen comparisons were made in which the results from a battery operated pump and an impinger sampler were com pared with the measurements from either two or three per meation samplers. To further evaluate their results, the investigators performed a regression analysis using their permeation sample means for each comparison as the dependent variable. The results are quite good with a corre lation coefficient of 0.95, a regression slope of 0.85. and an intercept of 0.15 over a range of 0.03 to 1.1 ppm as detected by the impinger. It should be noted that with five impinger samples of less than 0.1 ppm. the corresponding permeation devices detected considers hly higher concent rat ions (0.16 to 0.4 ppm).
SilvcrMein*'19' reported field results for acrylonitrile moni toring using 18 paired samples of GASBADCiE passive monitors and active systems (charcoal tubes and pumps) over a range of 0.8 to 3.8 ppm as determined by the active method. The differences in results using the active system as a reference ranged from --0.7 to 1,5 ppm. The difference in means. 2.18 for the passive versus 2.73 for the active system, was 25 percent. Further data were not presented.
West and Rcisrncr reported five sets of field results for vinyl chloride sampled with permeation dosimeters (REAL, Inc.) and charcoal tubes.13' Further interpretation of their results is presented in Table III. In each case data for the active system are the X values. Four of the correlation coefficient values are very near one. reflecting good correla tion; howev er, the slopes show quite a large degree of varia bility (0.69 to 1.31). indicating that badge values may fall either well below or above charcoal tube values. In those cases where the slopes were less than 1.0. very high humidi ties (67 to 91 percent) were reported bv the authors. This factor may have interfered with permeation, although the authors reported that humidity had no effect in laboratory validations; hence the variation in slope remains unex plained. The authors noted that the overall field results showed that the badges had a slight positive bias.
Hickey and Bishop exposed 78 pairs of side-by-side char coal tubes and 3M Organic Vapor Monitors to complex mixtures of organic chemicals in tire manufacturing opera tions.(9> Generally the sampling period ranged from three to
TABLE III
Regression Analysis of Vinyl Chloride Field Data131
N Range (ppm) r Slope Y-tntereept
7 0.02-1
0 99 1 19
8 0.08-1.8
0.99 069
12 002-6.9
1.0 1.31
39 0.OS-1.8
0.82 0.81
24 1.48-16.7 0.96 1.08
0.03 0 05 001 0.11 0.43
five hours, and most observations consisted of one monitor and the time weighted average concentration from two sequentially exposed charcoal tubes. Sixty-four of the sets were personal samples, while the remaining 14 were area samples. The samples were collected in two separate plants (30 sample pairs in one plant and 48 in the other). Of the 22 organics potentially available for analysis. 10 were detected over a sufficiently wide range of concentrations to allow for appropriate statistical analysis by linear regression. The results are interesting in that in the first plant. 9 of the 10 organics measured by the dosimeters showed higher vapor concentrations as compared to the charcoal tubes, while in the second plant only three substances had a regression slope greater than one. The combined data for both plants did not indicate that the passive system was consistently biased when compared to the active system. The authors did point out that generally the V-intercepts (Y=passive dosimeter data) were slightly negative, a finding which may indicate a lack of sensitivity on the part of the dosimeters at low concentrations. For the remaining 12 compounds, paired t-tests revealed no significant difference between the char coal tube and passive monitor means at the 95 percent confidence level. The use of t-tests to analyze such data has been questioned since the means of the tw o methods may be very similar but the components of paired values can be considerably different.*191 This condition can only be revealed through regression analyses.
In 1980. Mazur et al.(A*' reported limited field data for halothane and enflurane measurements using both 3M Organic Vapor Monitors (OVM) and an active system (charcoal tubes and pumps). For halothane three paired samples were reported. The mean concentration for the active system was 2.01 ppm while 1.9 ppm was reported for the OVM. a difference (relative to the active sy stem) of five percent. Only one data pair was reported for enflurane: 0.49 ppm for the OVM and 0.52 ppm for the active system. Obviously, more data are needed to draw conclusions regarding a comparison of the two methods for these agents.
A second study by Mazur et al.iAg' reported field compar isons of passive dosimeters and active systems (pumps and charcoal tubes) in sampling for trichloroethy lenc (TCE) and methylchloroform (MC). Both DuPont PRO-TEK and 3M Organic Vapor Monitors were used for the passive sy stems. Personal samples included exposure of one each of all three monitors. Area sample results involved three av erage values: one was the average of three charcoal tubes, and the other tw o. the average of two of each type of dosimeter. For MC. 11 personal and 7 area data points collected over time peri ods of 1 to 5 hours at 15 to 21 Cand 35 to 40 percent relative humidity were reported. For TCE. 22 personal and 7 area data points collected over periods of about I to 6 hours at 18 to 24 C and 30 percent relative humidity were reported. A regression analysis in which the charcoal tubes were the independent variable was reported by the authors. In each of the following data sets the presented values involve TCE personal and stationary sampling followed by MC personal and stationary sampling. For the DuPont badge, regression
American Industrial Hygiene Association JOURNAL
(43) 8-82
3M 00209S
17
slopes of 1,0, 0.99, 0.99, and 0.98, and correlation coefficients of 0.98,0.98.0.94, and 0.94 were obtained. For the 3 M badge, regression slopes of 1.08. 1.06, 1.07. and 0.90. and correlation coefficients of 0.98. 0.98, 0.98. and 0.90 were determined. These values appear to be quite good: however, the authors did not report if they tested the statistical signifi cance of these values. They also did not report average of face velocities associated with stationary samples.
Evans ei o/.<60> of Great Britain reported field validation data for the Porton diffusion device while measuring methyl ethyl ketone. In this case the conventional sampler was a pump and a cassette fitted with a charcoal cloth similar to that used in the Porton device. A regression analysis per formed with their data showed good correlation (0.9) and good slope (0.9): however, the intercept value (4.69) indi cated that, at low concentrations, the "home-made-dev ice gave lower values than those determined with the conven tional monitor. Concentrations reported for the conven tional device ranged from 11 to 189 ppm.
Benson and Boyce's" field tested the Monsanto Poropak N dev ice in Great Britain. Conventional samplers consisted of pumps and Poropak N polymer tubes. Sixty-five pairs of samples were obtained, and the range of acrylonitrile mea sured by the tubes was 0.13 to 21.65 ppm. Regression analy sis of their data indicates only fair correlation (0.63). a low dope (0.46), and a negative intercept (--2.06). These values appear to result from the apparent inability of the passive device to accurately detect concentrations less than 0.5 ppm. Also, comparisons between values over the lower half of .onccntrations sampled showed considerable scatter.
The final field study to be discussed suggests perhaps the most serious discrepancies resulting from use of charcoal passive dosimeters.'61* This study was performed by NIOSH lersonnel in conjunction w ith industry-wide studies of the dry-cleaning, screen printing, and boat manufacturing indusries. and also included one viscose rayon and one cellothane plant. Carbon disulfide, perchloroethylene, toluene, methylisobutyl ketone (MIBK). styrene, and acetone were :ampled using the 3M OVM. the GASBADGE. and active ivstems with charcoal tubes. The presentation of the study design is not clear, but it appears that area samples involved all three devices while personal samples involved charcoal tubes and only one of either passiv e dev ice. In that this study nv olves six compounds in 64 plants, the volume of data is (uite large. In addition to regression analysis, paired t-tests ind Wilcox signed rank tests were performed by the authors o determine equivalence of data sets. As noted earlier he use of t-tests for determination of equivalence has been questioned.'19'
Table IV shows the primary results of this study. As can be seen, the range of correlation coefficients (r) for most com pounds was quite large. Although 12 plants were sur veyed for toluene and MIBK. the data ..ere grouped ogether. and therefore ranges of the correlation coefficients
ould not be determined. For carbon disulfide, one plant as surveyed with the OV'M and GASBADGE, and one was urveyed with the GASBADGE only. For the ranges of r eported in Table IN', the upper values are quite acceptable.
with the except ion of carbon disulfide using the GASBADGE. However, the correlation coefficient for carbon disulfide using the OVM was 0.95. The correlation data can be summed up as being extremely variable. Table IV also reveals that concentration had an effect on the correlation coefficient for three of the compounds, though this was true for both monitors only w hen measuring acetone concentra tions. Regression slopes were as variable as the correlation coefficients. The authors tested the slopes to sec if they were significantly different from 7cro. and for acetone and carbon disulfide a difference could not be demonstrated for several of their data sets. This indicated that there was no relation ship between the results obtained with the active system and those obtained with the passive dosimeter. For other com pounds. it would have been useful to lest the difference of the slope from one. which if not significantly different would indicate agreement of the two methods.
In tests of equivalence of data sets, the authors noted that for all plant data combined, only toluene showed equality, and this for the charcoal tube-G ASBADGE (CT-GB) com parison. However, when results from indiv idual plants are used, the comparison outcomes are quite variable. For perchloroethylene, equality was reported for one of three CT-BG comparisons and for one of two CT-3M sets. For styrene, two of six CT-GB and no CT-3M comparisons showed equality. For acetone, three of five CT-3M compari sons and one of six CT-GB data sets showed equality. In addition. GB-OVM comparisons showed equality in 6 of 17 comparisons. It is obvious that repeatability was not demon strated in this study. Whether the problem involves the dosimeters, investigative or laboratory techniques, and or env ironmental conditions cannot be determined. In the only other field study of more than one plant. Hickey and Bishop191 also reported some problems w ith the consistency of observations. These limited results clearly demonstrate the need for additional field studies of passive dosimeters as compared with standard monitoring techniques.
discussion
Passive dosimetry (monitoring) is a rapidly developing tech nology as witnessed by the proliferation of devices and applications since Palmes and Gunnison introduced their concepts just under ten years ago.'221 The latest entry into the field comes from the MSA Company and involves an adap tation of their length-of-stain direct reading tubes for inor ganic gases'621 which incorporates the application of molecu lar diffusion and a chemically impregnated paper as the sampling medium. Although research results are not availa ble. as a first approximation one might assume that these devices have precisions and biases similar to those of con ventional detector tubes.
For any new technology to be accepted and used by prac ticing professionals, the development of a body of knowl edge demonstrating efficacy is necessary. With env ironmen tal monitoring techniques, the determination of the efficacy usually starts in the laboratory and culminates in the field. In the case of passiv e monitors, a body of knowledge based on laboratory testing is rapidly being developed. Of the vari-
3M 002099
Am Ind Hvg Assoc J (43)
August, 19?
TABLE IV Major Results of a Field Study for Organic Vap rs'C1'
Concentration Substance Comparison Overall r Range of r Dependency
Perchloroethylene Styrene
Acetone
Toluene
MIBK
CS,
CT-GB CT-3M
CT-GB CT-3M
CT-GB CT-3M
CT GB CT-3M
CT-GB CT-3M
CT-GB CT-3M
0 62 0 86
0 82 0 76
0 38 0 45
0 80 0 91
0 88 0 79
0 30 0 95
0 62-0.99 084-0.94
0 65-0.97 0 48-0.86
0 36-0 86 0.25-0 83
NA NA
NA NA
0.03-0 38 NA
Yes Yes Yes
Yes
ahles that have been studied, three appear to uniquely affect a diflusion monitors accuracy in measuring airborne concen trations of gases or sapors. The most important factor appears to be determination of the contaminants' diffusion coefficient (or the sampling rate when the dosimeter's geometry is also considered), the wind velocity at the dosimeter face, and the relative humidity of the sampled air. As discussed earlier, there arc also a variety of potential sources of error, such as interfering contaminants, sorbent capacity and problems associated with analytical determina tions. which are common to both passive and active mea surement techniques.
laboratory determination of sampling rates (DA L) for a specific monitor and a specific contaminant are important and are being provided by several dosimeter manufacturers for an ever increasing number of compounds. Once an appropriate sampling rate has been determined, corrections lor Held use, specifically for temperature variations, can be made. The main problem would involve situations where the env ironmcntal temperature Huctuated widely (more than 25 C) and went unnoticed, a very unlikely condition.
The research on effects of face velocities demonstrate that few problems should be encountered where dosimeters are worn by workers as personal monitoring dev ices.<l u Z4 iS'32' Their use as area monitors should be carefully evaluated to ensure that stagnant atmospheres (velocities less than 7.5 cm sec)arc not involved. High wind vclocities(at least what would normally be encountered in the workplace) or wind direction do not appear to have adverse effects on dosime ters with wind screens.
Of greatest concern as a result of reviewing the literature on laboratory testing of passive dosimeters is not the results but rather the thoroughness of their presentation. As dem onstrated in Tables I and II. where statistical analyses are presented by researchers, or where sufficient data are pre sented to allow the reader to determine bias and precision, the results are verv encouraging. Unfortunately the presentation of experimental design, as well as sufficient data and or statistical analyses. are often lacking. This is true for some
individual researchers as well as for several manufacturers of thedev ices, especially those for inorganic compounds. If one recommendation regarding laboratory testing is made, it would be that those researchers inv olvcd in the evaluation of passive dosimeters in the laboratory take the time to report the conditions of their experiments, especially equipment used and procedures for determining "known" concentra tions. and as much detail about their results as possible. If summarized data are presented, the author should present the known concentration at each level, where levels are determined by concentration and time, the number of obser vations made with passive dosimeters, and the average value and standard deviation of the results. Statistical analyses, again at each level tested, should involve determination of the coefficient ol variation (precision) and the bias as described in equations (7) and (8), respectively. Once the evaluations are made at the various test levels, the determi nation of a pooled precision and bias is appropriate. In addition to these measurements, researchers may also choose to present an overall system accuracy. To develop a better understanding of appropriate statistical techniques and their application to passive dosimetry, a review of l.autenbcrgcr el al. is recommended.'"'
For most active monitoring systems used in industrial hygiene the random sampling error is usually associated with the pump and is traditionally set at 5 percent.'1"' In many cases, especially for the measurement of organic vapors, the analytical procedures and consequently their associated errors are equivalent lor both passive and active systems. Nevertheless, both systems have random error; consequently, one should not expect perfect agreement of the results of comparisons obtained under field test condi tions. Another factor complicating the evaluation ol field results is the greatly increased possibility for the introduc tion of operator, or systematic, errors. Since active systems require mechanical pumps, the potential for operator error would seem to be greater than for passive systems.
Overall, it is apparent that existing field observations comparing passive dosimeters with standard monitoring methods are highly varied. While some studies demonstrate good correlation and slope.'" ^4t" others show only good correlation.'* or are extremely varied for both categories. ''1' Collectively, these references neither support nor refute the use of passive dosimeters. Certainly environmental factors affect active systems as well as passive systems. In theory, a .case can be made that environmental factors (wind and humidity) affect passive systems to the greatest extent, w hile temperature and pressure variations most greatly affect active systems. On the other hand one can also state that poor experimental quality control may affect such factors as contamination, time measurement error, and analytical error. Of course, chemical interferences may affect both systems.
As with laboratory experimentation, recommendations regarding the field testing of passive dosimeters involve a plea for better reporting ol both field conditions and results of analysis. First, for both personal and area monitoring, the estimation and or measurement of face velocity is impor-
Amencan Industrial HKfiene Association JOURNAL
(43. 8 8?
3M 002100
619
tant. Of equal importance is the reporting of airborne con taminants other than the one(s) of interest and environmen tal variables including temperature, pressure, and relative humidity along with information as to their variation over the period of observation. Again, if raw data cannot be presented, the reported results for each level tested (X value as determined by the standard method) should include the number of observations made with passive dosimeters, and t heir associated mean and coefficient of variation. Statistical evaluations also should include a regression analysis of the data as outlined earlier. Undoubtedly, additional research is needed on the effect of not considering the error associated with the supposedly independent (X) variable.
In summary, passive dosimeters show great promise as an important tool. The results presented in Tables I and II indicate that the precisions of the dosimeters are essentially equivalent to conventional techniques and in many cases the additional five percent error associated with mechanical >umps makes passive dosimeter systems even more attracivc. This, coupled with their ease of use, lack of required naintenance. acceptance by workers due to light w eight, and innecessary calibration make passive dosimeters extremely advantageous. Certainly they will not replace conventional ncthods. as these have their place, especially for area sam>ling. The continued and grow ing use of passive dosimeters,
owever. should generate additional data documenting their ieliability and eliminating doubts about their usefulness.
icknowledgement
.'he assistance of Dr. H. Kenneth Dillon. Head. Industrial )vgiene Chemistry Section of Southern Research Institute, n critically review ing this paper is gratefully acknowledged.
eferences
1. T mpkins, F.C. and R.L. Goldsmith: A New Personal Dosimeter for Monitoring of Industrial Pollutants. Am. Ind. Hyg. Assoc. J 38:371 -377 (1977).
2. West. P.W. and K.D. Reiszner: Field Tests of a PermeationType Personal Monitor for Vinyl Chloride. Am. Ind. Hyg. Assoc. J. 39:645-650 (1978).'
3. Lugg. G.A.: Diffusion Coefficients of Some Organic and Other Vapors in Air. Anal. Chem. 40:1072-1077 (1968).
4. Montalvo, J.G.: Total Elemental Content Passive Personal Monitors. Am. Ind. Hyg. Assoc. J. 40.1046-1054 (1979).
5. 3M Company: Organic Vapor Monitor Sampling Rate Vali dation Protocol. St. Paul. MN.
6. Jonas. L.C.. C.E. Billings, and C. Ulis: Laboratory Perfor mance of Passive Personal Samplers for Waste Anesthetic Gas (Enflurane) Concentrations. Am. Ind. Hyg. Assoc. J. 42:104-111 (1981).
7. Woebkenberg. M.L.: Current NIOSH Research on Passive Monitors. In Proceedings of the Symposium on the Develop ment and Usage of Personal Monitors for Exposure and Health Effect Studies, pp. 27-33. Evironmental Protection Agency. EPA - 600/9-79-032 (1979).
8. Environmental Protection Agency: Laboratory Evaluation of Commercially A vailable Passive Organic Personal Moni tors. Contract Number 68-02-2686.
J. Hickey, J.L.S. and C.C. Bishop: Field Comparison of Char coal Tubes and Passive Vapor Monitors with Mixed Organic Vapors Am. Ind. Hyg. Assoc. J. 42:264-267 (1981).
10. U.S. Department of Health. Educati n. and Welfare: Doc umentation of NIOSH Validation Tests. NIOSH 77-185. Cincinnati (April, 1977).
11. Lautenberger. W.J.. E.V. Kring, J.A. Morello: A New Per sonal Badge Monitor for Organic Vapors. Am. Ind. Hyg. Assoc J. 41 737-747(1980)
12. Bamberger, R.L..G.G. Esposito, B.W. Jacobs. G.E. Podoiak and J.F. Mazur: A New Personal Sampler for Organic Vapors. Am. Ind Hyg. Assoc. J. 39 701 -708 (1978).
13. National Mine Safety Company: GASBADGE Product Bulletin Chlorinated Solvents Performance Data. Oakdale. PA (1979).
14. National Mine Safety Company: GASBADGE Product Bulletin Aliphatic and Aromatic Performance Data. Oakdale, PA (1979).
15. Anonymous: Guide for Use of Terms in Reporting Data in Analytical Chemistry Anal. Chem. 52.221 (1980),
16. Shotwell. H.P., J.C. Caporossi. R.W. McCollom and J.F. Mellor: A Validation Procedure for Air Sampling Analysis Systems. Am. Ind. Hyg. Assoc. J. 40:737-742 (1979).
17. D'Agostino. R.B. and J.L. Gillespie: Comments on the OSHA Accuracy of Measurement Requirement for Monitor ing Employee Exposure to Benzene. Am. Ind. Hyg. Assoc. J. 39:510-513(1978).
18. Carlson, F.D., E. Sobel and G.S. Watson: Linear Relation ships Between Variables Affected by Errors. Biometrics 22:252-267(1966).
19. Tuggle, R.M.: Incorrect Use of /-Tests. Am. Ind. Hyg. Assoc. J. 42:325-326(1981).
20. Gordon, C.S. and J.T. Lowe: Carbon Monoxide Detector. U.S. Patent 1,644,014 (1927).
21. Plantz.C.A., P.W. McConnaugheyandC.C. Jenca: Colori metric Personal Dosimeter for Hydrazine Fuel Handlers. Am. Ind. Hyg. Assoc. J. 29:162-164 (1968).
22. Palmes, E.D. and A.F. Gunnison: Personal Monitoring Devices for Gaseous Contaminants. Am. Ind. Hyg. Assoc. J. 34:78-81 (1973).
23. Mazur, J.F., R.L. Bamberger and G.E. Podoiak: Develop ment and Evaluation of an Ammonia Dosimeter. Am. Ind. Hyg. Assoc J. 39:749-753 (1978).
24. Kring. E.V.. W.J. Lautenberger, W.B. Baker, J.J. Douglas: A New Passive Colorimetric Air Monitoring Badge System for Ammonia. Sulfur Dioxide, and Nitrogen Dioxide. Am. Ind. Hyg. Assoc. J. 42:373-381 (1981).
25. ACGIH: Threshold Limit Values for Chemical Substances and Physical Agents in the Workroom Environment with Intended Changes for 1981. American Conference of Govern mental Industrial Hygienists, Cincinnati (1981).
26. DuPont: PRO-TEK Colorimetric Air Monitoring Badge Sys tem Laboratory Validation Report, Ammonia Badge. Type C-10. E.l. DuPont de Nemours and Company. Wilmington, DE (1981).
27. Shor, R.M. and L.W. Anders: Direct ReadCarbon Monoxide Monitor Performance Under Possible Use Conditions. Pres entation at American Industrial Hygiene Conference. Portland, OR (May 25-29. 1981).
28. Hardy, J.K., P.K. Dasgupta. K.D. Reiszner. and P.W. West: A Personal Chlorine Monitor Utilizing Permeation Sampling. Env. Sci. Tech. 73:1090-1093(1979).
29. Moleculon Research Corp.: PROPLASTIC Chlorine Vapor Badge Information, Cambridge. MA.
30. Hardy. J.K., D.T. Strecker, C.P. Savariarand P.W. West: A Method for the Personal Monitoring of Hydrogen Sulfide Using Personal Sampling. Am. Ind. Hyg. Assoc. J. 42:283-
286(1981). 31. Graedel, T.E. and J.P. Franey: Gaseous Hydrigen Sulfide
Determination by Discoloration of Lead-Stabilized PVC. Am.
Ind. Hyg. Assoc. J 47:947-953 (1979).
0
Am Ind Hyg Assoc J (A3)
August 1982
3M 002101
32. McCammon, C.S. and J,W. Woodfin: An Evaluation of Passive Monitor for Mercury Vapor. Am, tnd. Hyg. Assoc. J. 35 378-386 (1977)
33. McCammon. C.S., S.L. Edwards, R.D. Hull. W.J. Woodfin: A Comparison of Four Personal Sampling Methods for the Determination of Mercury Vapor. Am. Ind. Hyg. Assoc. J. 41 528-531 (1980).
34. Cohen, H.J., R.K.Zahray, A.C. MisiaszekandH.J, Muranko: A New Passive Dosimeter for Mercury. Presentation at American Industrial Hygiene Conference, Portland, OR (May 25-29, 1981)
35 Palmas, E.O.. A.F. Gunnison, J. DiMattioand C.Tomczyk: Personal Sampler for Nitrogen Dioxide. Am. Ind. Hyg. Assoc. J 37 570-577(1976)
36 McMahon. R.,T. Klinger, B. Ferberand G. Schnakenberg: Hew Technology for Persona/ Sampling of /VO, and NO\ in the Workplace Presentation at American Chemical Society Exposition Symposium, Las Vegas. NVIAugust 25-28,1980).
37. DuPont: PRQ-TEK Colorimetric Air Monitoring Badge Sys tem Laboratory Validation Report, Nitrogen Dioxide Badge. TypeC-30. E I DuPont de Nemours and Company, Wilmington, DEI1981)
38. DuPont: PRO-TEK Colorimetric Air Monitoring Badge Sys tem Laboratory Validation Report, Sulfur Dioxide Badge. TypeC-20 E.l DuPont de Nemours and Company, Wilmington. DE (1981).
39 Silverstein. L.G.: Validation of Abcor GASBADGE for Acrylo nitrile and Improved Desorption Efficiency. Am Ind. Hyg. Assoc. J. 38 412-413(1977)
40. Hirayama, T. and M. Ikeda: Applicability of Activated Car bon Felt to the Dosimetry of Solvent Vapor Mixture. Am. Ind. Hyg. Assoc. J. 40 1091-1095 (1979)
41. Halliday, M.M. and J. Anderson: Determination of Halothane in Operating Theatre Air by Using a Passive Organic Vapor Dosimeter The Analyst 105 289-292 (1980)
42. Evans. P.R. and S.W. Horstman. Desorption Efficiency Determination Methods for Styrene Using Charcoal Tubes and Passive Monitors Am Ind Hyg. Assoc J. 42.471476(1981).
43. Anders, L.W. and H.E. Mullins: Comparison of Diffusional Organic Vapor Monitors with Charcoal Tubes for Sampling Laboratory Challenges to Contaminant Mixtures. Presenta tion at American Industrial Hygiene Conference, Portland, OR (May 25-29. 1981)
44. Mazur, J.F.. G.E. Podolak. G.G. Esposito, D.S. Rinehart and R.E, Glenn: Evaluation of a Passive Dosimeter for Col lection of 2-Bromo-2-Chloro-1,1.1-Trifluoroethane and 2Chloro-1,1,2-Trifluoroethyl Difluoromethyl Ether. Am. tnd. Hyg. Assoc J. 41 317-321 (1980).
45. DuPont: PRO-TEK Organic Vapor Air Monitoring Badges Laboratory Validation Protocol for Diffusion-Type Air Moni toring Badges with Solid Solvents. E.l. DuPont de Nemours and Company, Wilmington, DE (1981).
46. DuPont: Laboratory and Field Validation Report for PRO-TEK G-BB Diffusion-Type Badges for Monitoring Benzene Vapors. E.l, DuPont de Nemours and Company. Wilmington. DE (1981).
47. 3M Company: 03520 Organic Vapor Monitor with Backup Section. St. Paul. MN
48. Mazur, J.F., D.S. Rinehart, G.G. Esposito and G.E. Podolak: Evaluation of Passive Dosimeters for Assessing Vapor Degreaser Emissions Am Ind. Hyg Assoc. J 42 752756(1981)
49. Nelms, L.H., K.D. Reiszner and P.W. West: Personal Vinyl Chloride Monitoring Device with Permeation Technique for Sampling Anal. Chem. 49:994-998(1977).
50. Bailey, A. and P.A. Hollingdale-Smith: A Personal Diffu sion Sampler for Evaluating Time Weighted Exposure to Organic Gases and Vapors Ann. Occup. Hyg. 20 345356(1977).
51. Benson, G.B. and G.E. Boyce: A Thermally-Desorbable Passive Dosimeter for Personal Monitoring of Acrylonitrile Ann. Occup Hyg 24 55-75(1981).
52. Campbell, J.E. and R.B. Konzen: The Development of a Passive Dosimeter for Aniline Vapors. Am. tnd Hyg Assoc J. 47:180-184(1980).
53. Mullins. H.E. and L.W. Anders: A New Innovative Diffu sional Monitor for Sampling Ethylene Oxide in Air Presenta tion at American Industrial Hygiene Conference, Portland, OR (May 25-29. 1981).
54. Rodriguez, S.T., P.B. Olson and V.R. Lund: Colorimetric Analysis of Formaldehyde Collected on a Diffusional Moni tor. Presentation at American Industrial Hygiene Confer ence, Portland, OR (May 25-29, 1981).
55. DuPont: PRO-TEK Colorimetric Air Monitoring Badge Sys tem Laboratory Validation Report, Formaldehyde Badge. Ser ies II. Type C-60. E.l. DuPont de Nemours and Company. Wilmington. DE (1981)
56. Kriesel, R.S.: Formaldehyde Vapor Detection -- New Sam pling Technology. Presentation at American Industrial Hygiene Conference, Portland, Or (May 25-29, 1981).
57. Matherne, R.N., P.L. Lubs and E.J. Kerfoot: The Develop ment of a Passive Dosimeter for Immediate Assessment of Phosgene Exposures. Am Ind. Hyg. Assoc J. 42.681* 684(1981).
58. Hill. R.H. and D.A. Fraser: Passive Dosimetry Using Detec tor Tubes. Am. Ind. Hyg. Assoc. J. 47:721-729 (1980).
59. Jones, W.. E.D. Palmes. C. Tomczyk and M. Miltson: Field Comparison of Two Methods for Determination of NO.' Con centrations in Air. Am. Ind. Hyg. Assoc. J. 40:437438(1979).
60 Evans. M.. M. Molyneux. T. Sharp. A. Bailey and P. Hollingdale-Smith: The Practical Application of the Porion Diffusion Sampler for the Measurement of Time Weighted Average Exposure to Volatile Organic Substances in Air. Ann Occup. Hyg 20.357-363 (1977)
61. Zaebst, D.D., M.F. Boeniger and J.R. Burg: Field Compari son of Two Passive Organic Vapor Sampling Devices to the Charcoal Tube. Presentation at American Industrial Hygiene Conference. Houston, TX (May 18-29, 1980)
62. McKee, E.S., P.W. McConnaughey and I.M. Pritts: Colori metric Personal Dosimeters for Some Inorganic Contami nants. Mine Safety Appliances Co.. Pittsburgh, PA
29 December. 1981; Revised 8 February. 1982
American Industrial Hygiene Association JOURNAL
(43) 8 8!
3M 002102
621
LITERATURE REFERENCE
page I
, " P0ROPLASTIC SORBENT TUBE ", TECH CORPCAMBRIDGE, MA , 19 8 0
INFO. FROM MOLECULAR RESEARCH
ANONYMOUS , 21 , 1979
" MONITOR WORKER EXPOSURE TO CASES
, CHEM. ENG. NEWS P.
BAILEY, A & F.A. HOLLINODALE-SNITH , " A PERSONAL DIFFUSION SAMPLER FOR EVALUATING TIME WEIGHTED EXPOSURE TO ORGANIC CASES AND VAPORS ", ANN. OCCUPA. HYG 20 345-356 , 1977
BAMBERGER, R.L G G, ESPOSITO, B.W. JACOBS, G.E. PODOLAK AND J.F. MAZUR , " A NEW PERSONAL SAMPLER FOR ORGANIC VAPORS ", AM. IND. HYG. ASSOC. J 39,701 , 1978
BELL, D.R., K.D. REISZNER AND P.W. WEST , " A PERMEATION METHOD FOR THE DETERMINATION OF AVERAGE CONCENTRATIONS OF CARBON MONOXIDE IN THE ATMOSPHERE ", ANAL. CHEM. ACTA 77 255-262 , 1975
BELL, DR., REISZNER, K.D., AND WEST, P.W. , " A PERMEATION METHOD FOR THE DETERMINATION OF AVERAGE CONCENTRATIONS OF CARBON MONOXIDE IN THE ATMOSPHERE ", ANAL CHIM. ACTA 77, 245 , 1975
BRAUN,' D.L. , 1975
" GAS DETECTION DEVICE ", U.S. PATENT, 3,3924,219 ,
BRAUN, D L
" DETECTION OF MERCURY VAPORS AS AN ADJUST TO
RESPIRATORY PROTECTIVE DEVICES ", PRESENTED AT AI HA ANNUAL MEETING,
SAN FRANCISCO, CA , 1972
BROWN, R.H. AND WALKING, K.T , " THE PERFORMANCE OF TUBE-TYPE DIFFUSIVE SAMPLER FOR ORGANIC VAPOURS ", AMERICAN INDUSTRIAL HYGIENE CONFERENCE, HOUSTON, TX , 1980
BROWN, R.H., CHARLTON, J AND SAUNDERS, K J. , " THE DEVELOPMENT OF AN IMPROVED DIFFUSIVE SAMPLER ", AM. IND. HYG ASSOC. J. 42, 865 , 198 1
CAMPBELL, J E AND KQNZEN, R.B. , " THE DEVELOPMENT OF A PASSIVE DOSIMETER FOR AIRBORNE ANILINE VAPORS ", AM. IND. HYG. ASSOC. J. 41, 180 , 1980
D'AGOSTINO, R 8 AMD J.C. GILLESPIE , " COMMENTS ON THE OSHA ACCURACY OF MEASUREMENT REQUIREMENT FOR MONITORING EMPLOYEE EXPOSURE TO BENZENE. ", AM. IND. HYG. ASSOC. J 39:510-513 , 1978
EVANS, M , M MOLYNEUX, T SHARP, A. BASILEY AND p. HOLLINGDALE-SMITH , " THE PRACTICAL APPLICATION OF THE PORTON DIFFUSION SAMPLER FOR THE MEASUREMENT OF TIME WEIGHTED AVERAGE EXPOSURE TO VOLATILE ORGANIC SUBSTANCES IN AIR. ", ANN. QCCUF. HYG 20 357-363 , 1977
FERBER, B.I., F.A SHARP AND R W FREEDMAN , OF NITROGEN ", U.S. PATENT 3,992, 153 , 1976
" DOSIMETER FOR OXIDES
GONZALEZ, L , " PH.D THESIS (IN PROCESS) ", DEPT. OF CHEM. ENG. & APPLIED CHEMISTRY, U. OF TORONTO ,
GOSSELINK, D W , O L BKAVN, H E MULLINS AND S T. RODRIGUEZ , " A HEW PERSONAL ORGANIC 7APCR MONITOR WITH IN - S ITU SAMPLE ELUTION ", 3M
3H 002103
page 2
CO. TECH BROCHURE, <REPR1 NT OF PAPER PRESENTED AT A1 HA ME , 1978
HARDY, J.K , D.T STRECKER, C ? SAVARIAR AND P.W WEST , " A METHOD FOR THE PERSONAL MONITORING OF HYDROGEN SULFIDE USING PERMEATION SAMPLING ", AM. 1ND. HYG ASSOC J 4 2 < Z i . 2 3 3 - 2 8 6 , 1981
HARDY, J.K , P K. DASGUPTA, K D. REISZNER AND P.W. WEST , " A PERSONAL CHLORINE MONITOR UTILIZING FERMEATIOM SAMPLING ", ENVIRON. SCI TECH. 13 1090-1093 . 197?
HARRISON, J.W., LAWLESS, PA, RESEARCH TRIANGLE INSTITUTE , DOSIMETRY ", EPA (ESRLl REPORT 1976
GILBERT, D.E., AND WHITE, J H., " DEVELOPMENT STRATEGY FOR POLLUTANT EPA-600 / 2-7 6 - 0 3 4, NT IS FB-263-910 ,
HEARL, F J, AND MANNING, M P
" TRANSIENT RESPONSE OF DIFFUSION
DOSIMETERS ", AM. IND HYG ASSOC J 41, 778 , 1980
HILL, R.H. AND DA. FRASER , " PASSIVE DOSIMETRY USING DETECTOR TUBES " , AM. IND. HYG. ASSOC J 41< I 0> : 72 1 - 729 . 1 980
JONES, L.C., BILLINGS, C.E., AND LILIS, C , " LABORATORY PERFORMANCE OF PASSIVE PERSONAL SAMPLERS FOR WASTE ANESTHETIC GAS (ENFLURANE) CONCENTRATIONS ", AM. IND HYG ASSOC J 42, 104 , 1981
KAVANAGH, S., S.L. MILLER, J. SEAL, A J. STEVENS, J. SWALE AND D.A. REAVELEY , " AN EVALUATION OF THE PORTQN DIFFUSION SAMFLER FOR LONG-TERM MONITORING OF HALOTHANE VAPOUR CONCENTRATIONS ", AM. OCCUP. HYG. 23:133-146 , 1980
KRING, E.V., HOFFMAN , " FOR AMMONIA, ASSOC. J. 42
W.J LAUTENBERGER, W.B. BAKER, J.J. DOUGLAS AND A NEW PASSIVE COLORIMETRIC AIR MONITORING BAOGE SULFUR DIOXIDE AND NITROCEN DIOXIDE ", AM. IND. 373-381 , 1981
R . A. SYSTEM HYG.
LAUTENBERGER, W J., E.V. KRING AND J A. BADGE MONITOR FOR ORGANIC VAPORS ", AM 41(101;737-747 , 198Q
MORELLO , IND. HYG.
" A NEW PERSONAL ASSOC. J.
LUGG, G.A. , " DIFFUSION COEFFICIENTS OF SOME ORGANIC AND OTHER VAPOR IN AIR ", ANAL. CHEM. 40 1072 , 1968
MATHERNE, R N., P.L. LUB5 AND E.S. KERFOOT , " THE DEVELOPMENT OF A PASSIVE DOSIMETER FOR IMMEDIATE ASSESSMENT OF PHOSGENE EXPOSURES ", AM. IND. HYG. ASSOC. J, 42:481-484 , 1981
MAZUR, J.F., D.S. RINEHART, GO. ESPOSITO, AND G.E. PODOLAK , EVALUATION OF PASSIVE MONITORS FOR ASSESSING VAPOR DEGREASER EMISSIONS ", AI HA JOURNAL 42, 752-756 , 1981
MAZUR, J.F., G.E PODOLAK, AND B.T. HEITKE , " USE OF A GC CONCENTRATOR TO IMPROVE ANALYSIS OF LOW LEVELS OF AIRBORNE HYDRAZINE AND UNSYMMETRI CAL DIMETHYLHYDRAZINE ", AI HA JOURNAL, 4 1, 66-69 , 1 980
MAZUR, J.F , G.E. PODOLAK, G.C. ESPOSITO, D S. RINEHART, AND R.E. GLENN , " EVALUATION OF A PASSIVE DOSIMETER FOR COLLECTION OF 2-BROMO- 2-CHLORO-l , 1 , 1 ,-TRIFLUOROETHANE AND 2-CHLORO-1 ,2,-TRI FLUOROETHYL DIFLUOROMETHYL ETHER IN HOSPITAL OPERATING ROOMS ", AI HA JOURNAL, 41, 317-321 , 1980
3H 002104
page 3
MAZUR, J F., R.L BAMBERGER, G E PODOLAK, AND G.G. ESPOSITO , DEVELOPMENT AND EVALUATION OF AN AMMONIA DOSIMETER ", AI HA JOURNAL, 39, 749-753 , 1978
MC CAMMON, C.S. AND J W. WOODFIN , " AN EVALUATION OF A PASSIVE MONITOR FOR MERCURY VAPOR `, AM 1ND HYG ASSOC J. 38 378-384 1977
,
MC DERMOTT, D.L , K.D REISZNER AND P.W WEST , " DEVELOPMENT OF LONG-TERM SULFUR DIOXIDE MONITOR USING PERMEATION SAMPLING. ", ENVIR. SCI. AND TECH. 131087-1090 , 1979
MONTALVO, J.G , JR. , ` TOTAL ELEMENTAL CONTENT PASSIVE PERSONAL MONITORS. ", AM. IND HYG. ASSOC. J. 40:1046-1054 , 1979
MULLINS, H.E. AND L W ANDERS , " A NEW INNOVATIVE DIFFUSIONAL MONITOR FOR SAMPLING ETHYLENE OXIDE IN AIR ", AM. IND. HYG. ASSOC (IN PRESS) ,
J.
NADEAU, J S. AND D.G.B. EQQCOCK , " STABLE FREE RADICAL REAGENT AND SOLID PHASE SUITABLE FOR A NITRIC OXIDE DOSIMETER ", ANAL. CHE. 49 : 1 672- 1 476 , 1977
NADEAU, J S., ME. TREEN AND O.G.B BOOCOCK , " MASS TRANSFER EFFECTS IN A NITRIC OXIDE DOSIMETER. ", ANAL CHEM 50 1871-1873 , 1978
NELMS, L H , K.D REISZNER AND P.W VEST , " PERSONAL VINYL CHLORIDE MONITORING DEVICE WITH PERMEATION TECHNIQUE FOR SAMPLING. ", ANAL. CHEM. 49:994-998 , 1977
OROFINO, T A. AND AM USMANI , JULY;96-104 , 1980
" FASSIVE DOSIMETRY ", AM. LAB
PALMES, ED. A F GUNNISIN, J DI MATT IO AND C TOMCZYK , " PERSONAL SAMPLER FOR NITROGEN DIOXIDE ", AM. IND. HYG. ASSOC. J. 37:570-577 , 1976
PALMES, E.D. AND R H LINDENBOOM , " OHM'S LAW, FICK'S LAW AND DIFFUSION SAMPLERS FOR GASES ", ANAL CHEM. 51:2400-2401 , 1979
PALMES, E.D., A.F GUNNISON, J D. MATTIO AND C. TOMZYK , " PERSONAL SAMPLER FOR NITROGEN DIOXIDE ", AM IND HYG. ASSOC J 37:570-577 , 1976
PODOLAK, G E., R.M MCKENSIE, D.S RINEHART, AND J F. MAZUR , " A RAPID TECHNIQUE FOR COLLECTION AND ANALYSIS OF PHENOL VAPORS ", AI HA JOURNAL, 42, 734-738 , 1981
PROCEDDINGS OF AN ACGIH TOPICAL SYMPOSIUM, CINCINNATI, OHIO , DOSIMETRY FOR CHEMICAL AND PHYSICAL AGENTS ", i , 1980
PURNELL, C.J , WRIGHT, ME , AND BROWN, R H. , " PERFORMANCE OF THE PORTON DOWN CHARCOAL CLOTH DIFFUSIVE SAMFLER ", ANALYST 106, 590 , 1981
REISZNER, K.D. AND P.W. WEST , " COLLECTION AND DETERMINATION OF SULFUR DIOXIDE INCORPORATING PERMEATON AND WEST-GAEKE PROCEDURE ", ENVIRON SCI TECH 7 526-531 . 1973
R O OR T r. U H Z ST. F B OLSON AND V p LUND . " COLQRMETRiC ANALYSIS OF
3H 002105
page 4
FORMALDEHYDE COLLECTED ON A D.'FFUSIOMAL MONITOR ", AM ASSOC J <IN PRESS) ,
IND. HYC .
SCHNAKENBEKG, G., JR
" US BUREAU OF MINES TECHNICAL PROGRESS
REPORT 95 ", PITTSBURGH MINING AND SAFETY RESEARCH CENTER, PITTSBURGH,
PA , 1974
SEFTON, M.V AND C LOMBARDI , " CONTINUOUS MONITOR OF THE EXPOSURE TO INDUSTRIAL GASES AND VAPOR CONTAMINANTS , U S PATENT APPLICATION , 1980
SEFTON, M.V , A. V KOSTAS AND C LOMBARDI , ' ANALYSIS OF DIFFUSION WITH IRREVERSIBLE REACTION IN A PASSIVE DOSIMETER ", PROCEEDINGS SECOND WORLD CONGRESS OF CHEMICAL ENG MONTREAL , 1981
SEFTON, MV , E.L. MASTRACCI AND J.L MANN , " RUBBER DISK PASSIVE MONITOR FOR BENZENE DOSIMETER ", ANAL. CHEM 53 458-441 , 1981
SHOR, R.M., L.W. ANDERS AND R A. BERNIER , " DIRECT READ CARBON MONOXIDE MONITOR PERFORMANCE UNDER POSSIBLE USE CONDITIONS ", 3M COMPANY TECHNICAL BROCHURE ,
SILVERSTEIN, L.G. , " VALIDATION OF AECOR "GAS-BADGE" FOR ACRYLONITRILE AND IMPROVED DESORPTION EFFICIENCY ", AM IND. ASSOC. J. 38.412-413 , 1977
HYG
STEPHENSON, K.A. , " PASSIVE MONITORING DEVICES FOR ANALYSIS OF BENZENE AND CARBON DISULFIDE ", UBTL DIV., UN. OF UTAH RESEARCH INSTITUTE, SALT LAKE CITY.UT , 1979
TOMPKINS, F.C., JR AND R.L. GOLDSMITH , " A NEW PERSONAL DOSIMETER FOR THE MONITORING OF INDUSTRIAL POLLUTANTS. ", AM IND. HYG. ASSOC. J. 38:371-377, 1977
TOSHIKO, H. AND M IKEDA , " APPLICABILITY OF ACTIVATED CARBON FELT TO THE DOSIMETRY OF SOLVENT VAPOR MIXTURE ", AM. IND. HYG ASSOC J 40:1091-1094 , 1979
WEST, P.W. AND K D REISZNER , " FIELD TESTS GF PERMEATION-TYPE PERSONAL MONITOR FOR VINYL CHLORIDE ", AM. IND. HYG. ASSOC. J. 39`445-450 , . 1978
WILLIAMS, K.E., AND J F. MAZUR , " GAS CHROMATOGRAPHIC ANALYSIS OF ACETIC ACID IN AIR ", AIHA JOURNAL, 41, 1-4 , 1980
3M 002106