Document yr3wexv9jx984axMGzMjx1xr
SALESMAN'S CALL REP CRT - CVGAN5C DESIGN MARKETING DEPARIMC \
1 --CENTRALOFFICE COPY
OFFICE ROUTING CHe BOXES
CUSTOMER NAME
CAMPBELL SOUP
DATE OF CALL
11/1/65
QDDDODD
FINE CHEMICAl
STREET ADDRESS
2550 VI. 35th St
INTERMEDIATES PLASTICIZERS AUTO. FUEIS & TUB'S. RESIN MATERIALS
CUV AND STATE
Chicago,
n NEW ACCOUNT
CALI UNITS THIS CAII
111.
1
fCTUAL CA^S^UNITS) THIS YFAR
REQUIRED CALLS(UNITS) PFR YFAR
CHANGE REQUIRED CALLS (UNITS) TO________ '
PAPER CHEMICALS
FUNCTIONAL FLUIDS
RUBBER CHEMICALS ATTENT'ld'N OF:-
CONTACT ADD RM
ta7n-' wShaw - SS 1A'
DATA
ACCOUNT PROFILE CHANGES
MAILING LIST
ADD RM MP MG
CODE NUMBERS
EXTRA COPIES
MAJOR GRADE SPG
PRODUCT INFORMATION
MARKET
UNIT
. . PRODUCT NAME
.'
Code
PRICE
TOTAL PURCHASES
1000 LB. LIMITS
TOTAL `
MONSANTO
%
CODE
SOURCES OF SUPPLY
%
CODE
% CODE
%
` .7 -
-'
FIRST - DICTATE ORDER RECEIVED-DISTRICT ACTION REQUIRED-PERSONNEL CONTACTED SECOND - REPORT OBJECTIVE-RESULTS-FURTHER ACTION REQUIRE!
CONTACT: Bob Rehak - Engineer
\
OBJECTIVE: Called at Rehak's request to discuss the conver- . . sion of a Dowtherm system to Therminol.
RESULTS: Rehak is considering the conversion for two reasons:
1) with the present system the Dowtherm A operating with a 14 lb. gauge set takes three hours to heat the kettle batch from 100 F. to 425 F. Reha
wmuld like to speed this up by perhaps going to Therminol.
2) safety of Therminol versus Dowtherm
.
I explained to Rehak that Dowtherm vapor heating and Therminol liquid heating were entirely different. A major expense might be required to convert. I told Rehak we v/ould study the design of the system and tell what would have to be done to make this conversion assuming., . of course, we could reduce heat up time.
ATTN: Stan Shaw:
An extra blueprint was not available. Hope all the pertinent
data is here. Can we make this conversion at a nominal cost
and reduce heat up time?
.
HEATER Eclipse Dowtherm A vaporizer Model #33
1 million B.T.U.
Operating Pressure 14 lbs. which gives 550 F. Dowtherm.
PUMP:
Dean Bros.
30 G.P.M.
mle----------DISTRICT OFFICE
75 ft. total discharge head
Chicago
SALESMAN Dave Hosmer
DT174/6
C3 S 33) (REV. 11/63)
DSW 434964
STLCOPCB4088024
_ .r_ S&onNAME
.........
, ..... .........
. ............ ^
.. CAI\ ELL SOUP ' -------------------------- --- ' '
....................
UAIC ur CALL
" 11/1/65
JACKET:
3 ft. 1 In. height
..............
5 ft. 6 in. inside diameter
3/8 in. stainless inside wall
3/16 in. carbon outside wall
1 5/8 in. gap
. v.i
SYSTEM:
no expansion tank, entirely closed system
BATCH:
400 gallon animal fat
8.1 lbs./gallon
.
24 p.s.i.a. steam through |-"line purge
2 mm. Hg. vacuum
'
If anything is left out, Stan, please let me know.
\
S-950-3
GENERAL SALES COPY
DSW 434965 STLCOPCB4088025