Document yr3wexv9jx984axMGzMjx1xr

SALESMAN'S CALL REP CRT - CVGAN5C DESIGN MARKETING DEPARIMC \ 1 --CENTRALOFFICE COPY OFFICE ROUTING CHe BOXES CUSTOMER NAME CAMPBELL SOUP DATE OF CALL 11/1/65 QDDDODD FINE CHEMICAl STREET ADDRESS 2550 VI. 35th St INTERMEDIATES PLASTICIZERS AUTO. FUEIS & TUB'S. RESIN MATERIALS CUV AND STATE Chicago, n NEW ACCOUNT CALI UNITS THIS CAII 111. 1 fCTUAL CA^S^UNITS) THIS YFAR REQUIRED CALLS(UNITS) PFR YFAR CHANGE REQUIRED CALLS (UNITS) TO________ ' PAPER CHEMICALS FUNCTIONAL FLUIDS RUBBER CHEMICALS ATTENT'ld'N OF:- CONTACT ADD RM ta7n-' wShaw - SS 1A' DATA ACCOUNT PROFILE CHANGES MAILING LIST ADD RM MP MG CODE NUMBERS EXTRA COPIES MAJOR GRADE SPG PRODUCT INFORMATION MARKET UNIT . . PRODUCT NAME .' Code PRICE TOTAL PURCHASES 1000 LB. LIMITS TOTAL ` MONSANTO % CODE SOURCES OF SUPPLY % CODE % CODE % ` .7 - -' FIRST - DICTATE ORDER RECEIVED-DISTRICT ACTION REQUIRED-PERSONNEL CONTACTED SECOND - REPORT OBJECTIVE-RESULTS-FURTHER ACTION REQUIRE! CONTACT: Bob Rehak - Engineer \ OBJECTIVE: Called at Rehak's request to discuss the conver- . . sion of a Dowtherm system to Therminol. RESULTS: Rehak is considering the conversion for two reasons: 1) with the present system the Dowtherm A operating with a 14 lb. gauge set takes three hours to heat the kettle batch from 100 F. to 425 F. Reha wmuld like to speed this up by perhaps going to Therminol. 2) safety of Therminol versus Dowtherm . I explained to Rehak that Dowtherm vapor heating and Therminol liquid heating were entirely different. A major expense might be required to convert. I told Rehak we v/ould study the design of the system and tell what would have to be done to make this conversion assuming., . of course, we could reduce heat up time. ATTN: Stan Shaw: An extra blueprint was not available. Hope all the pertinent data is here. Can we make this conversion at a nominal cost and reduce heat up time? . HEATER Eclipse Dowtherm A vaporizer Model #33 1 million B.T.U. Operating Pressure 14 lbs. which gives 550 F. Dowtherm. PUMP: Dean Bros. 30 G.P.M. mle----------DISTRICT OFFICE 75 ft. total discharge head Chicago SALESMAN Dave Hosmer DT174/6 C3 S 33) (REV. 11/63) DSW 434964 STLCOPCB4088024 _ .r_ S&onNAME ......... , ..... ......... . ............ ^ .. CAI\ ELL SOUP ' -------------------------- --- ' ' .................... UAIC ur CALL " 11/1/65 JACKET: 3 ft. 1 In. height .............. 5 ft. 6 in. inside diameter 3/8 in. stainless inside wall 3/16 in. carbon outside wall 1 5/8 in. gap . v.i SYSTEM: no expansion tank, entirely closed system BATCH: 400 gallon animal fat 8.1 lbs./gallon . 24 p.s.i.a. steam through |-"line purge 2 mm. Hg. vacuum ' If anything is left out, Stan, please let me know. \ S-950-3 GENERAL SALES COPY DSW 434965 STLCOPCB4088025