Document ypokDYZ69eBYY4a28Z53VqZp3
Monsanto material safety data
Page 1 of 6
f------------------------------------------------------------------------ \ MONSANTO PRODUCT NAME
Polychlorinated Biphenyls (PCBs)
N__________________________ *___________________ /
MONSANTO COMPANY 800 N. LINDBERGH BLVD.
ST. LOUIS, MO 63167
Emergency Phene No. (Cell Collect) 314-694-1000
PRODUCT IDENTIFICATION
The following materials contain 99.9% or greater PCBs. For information about other ingredients in form ulations containing PCBs, contact the manufacturer of those ingredients.
Synonym*:
PCBs Chlorodiphenyl (_% Cl)
Chlorinated biphenyl Polychlorinated biphenyl Chlorinated biphenyls (appro*. _% Cl)
Trade Names
(Commonly used Monsanto products)
Askarel" Aroclor*1 Series HJ16, 1221, 1232, 1242, 1248, 1254, 1260
Thermlnol*' FR Series
'
CAS No.:
001336363, 063469219, 012672296, 011097691, 011096625 and others
WARNING STATEMENTS
Federal regulations under the Toxic Substances Control Act require PCBs and PCB items to be marked. (Check regulations for details.)
MATERIAL SAFETY DATA
PotycMorinatdd Blphnyt* (PCBs)
i--------------------
| CAUTION -
| CONTAINS
I tPoMcMOPn^ClS*#*
| FOft PflOKR CM8POSM HMOMMnO*
I CONTACT U S ENWMMMMTAl
| PROTECTION AGENCY
I
PRECAUTIONARY MEASURES
Care should be taken to prevent entry into the environment through spills, leakage, use. vaporization, or disposal of liquid or containers. Avoid prolonged breathing of vapors or mists. Avoid contact with eyes or prolonged contact with skin. If skin contact occurs, remove by washing with soap and water. Following eye contact, flush with water. In case of spillage onto clothing, the clothing should be removed as soon as practical, skin washed, and clothing laundered. Comply with all federal, stale, and local regulations.
HONS 00322**
TOWOLDMONOO11655 WATER_PCB-00004771
Monsanto MATERIAL SAFETY DATA
EMERGENCY AND FIRST AID PROCEDURES
Page 2 ol 6
fngMtton:
Consult a physician. Do not induce vomiting or give any oily laxatives. NOTE TO PHYSICIAN--It large amounts are ingested, gastric lavage is suggested.
Skin:
If liquid or solid PCBs are splashed or spilled on skin, contaminated clothing should be removed and the skin washed thoroughly with soap and water. NOTE TO PHYSICIAN--Hot PCBs may cause thermal burns
Eyes:
Eyes should be irrigated immediately with copious quantities of running water for at least 15 minutes if liquid or solid PCBs get into them. A petrolatum-based ophthalmic ointment may be applied to the eye to relieve the irritating effects of PCBs.
Inhalation:
Remove to fresh air. If skin rash or respiratory irritation persists, consult a physician. NOTE TO PHYSICIAN--If electrical equipment arcs over, PCBs or other chlorinated hydrocarbon dielectric fluids may decompose to produce HCI, hydrochloric acid, a respiratory irritant.
OCCUPATIONAL CONTROL PROCEDURES
Bye Protection:
Wear chemical splash goggles and have eye baths available where there is significant potential for eye contact.
Skin Protaetlon:
Wear appropriate protective gloves and protective clothing that provide a barrier to prevent skin contact. Consult glove manufacturer to determine appropriate type glove for given application. Wear chemical safety goggles and a face shield and a protective apron that provides a barrier when splashing is likely. Wash immediately if skin is contaminated. Remove contaminated clothing promptly and launder before reuse. Clean protective equipment before reuse. Provide a safety shower at any location where skin contact can occur. Wash thoroughly after handling.
Paaphatory Protaetlon:
ATTENTION: Repealed or prolonged contact may cause chkxacne in some people.
Avoid breathing vapor or mist. Use NIOSH/MSHA approved equipment when airborne exposure limits are exceeded. Full facepiece equipment is recommended and, if used, replaces need for face shield and/or chemical splash goggles. Consult respirator manufacturer to determine type equipment for given application. The respirator use limitations specified by NIOSH/MSHA or the manufacturer must be observed. High airborne concentrations may require use of self-contained breathing apparatus or supplied air respirator. Respiratory protection programs must be in compliance with 29 CFR Part 1910.134.
Ventilation:
Alrtoma Exposure Limits:
Provide ventilation to control exposure levels below airborne exposure limits. Use local mechanical exhaust ventilation at sources of air contamination such as open process equipment.
Chlorinated biphenyl (approximately 42% chlorine) OSHA PEL: 1 mg/m3 8-hour time-weighted average - Skin'
ACGIH TLV: 1 mg/m3 8-hour time-weighted average - Skin' 2 mg/m3 short-term exposure limit - Skin*
Chlorinated biphenyl (approximately 54% chlorine)
OSHA PEL: 0.5 mg/m3 8-hour time-weighted average Skin* ACGIH TLV: 0.5 mg/m3 8-hour time-weighted average - Skin*
1 mg/m3 short-term exposure limit - Skin*
`Skin notation moans that skin absorption ot this material may add to the overall exposure. Avoid skin contact.
HONS 00322 5
MATERIAL SAFETY DATA
TOWOLDMONOO11656 WATER PCB-00004772
MATERIAL SAFETY DATA
Monsanto material safety data
FIRE PROTECTION INFORMATION
Pag* 3 of 6
Fin and Explosion:
PCBs are fire-resistant compounds. They may decompose to form CO, CO*. HCI,
phenolics, aldehydes and other toxic combustion products under severe conditions such as exposure to flame or hot surfaces.
At temperatures in the range of 600-650C in Ihe presence of excess oxygen PCBs may form polychlorinated dibenzofurans (PCDFs). Laboratory studies under similar conditions have demonstrated that PCBs do not produce polychlorinated dfbenzo-pdioxins (PCDDs).
PCBs in electrical equipment have been reported to produce both chlorinated dioxins (PCDDs) and lurans (PCDFs) during fire situations. These combustion products may result all. or in part, from non-PCB components of the dielectric fluids or other combusted materials. Consult the equipment manufacturer for information regarding composition of the dielectric fluids in electrical apparatus.
Standard fire fighting wearing apparel and self-contained breathing apparatus should be worn when fighting fires that involve possible exposure to chemical combustion products. Fire fighting equipment should be thoroughly cleaned and decontaminated after use.
If a PCB transformer is involved in * fire-related incident, the owner of the transformer may be required to report the incident. Consult and follow appropriate federal, state, and local regulations.
REACTIVITY DATA________________
PCBs are very stable, fire-resistant compounds.
HEALTH EFFECTS SUMMARY
Skin Contacti
PCBs can be absorbed through intact skin. Local action on skin is similar to that of common organic solvents where contact leads to removal of natural fats and oils with subsequent drying and cracking of the skin A potential exists for the contracting of chloracne.
Eya Contact: The liquid products and their vapors are moderately irritating to eye tissues.
Ingaatlon:
The acute oral toxicities of the undiluted compounds are: LDM rats--8 65 gm/kg for 42% chlorinated, and 11.9 gm/kg for 54% chlorinated--' slightly toxic."
Inhalation:
Animal experiments of varying duration and at different air concentrations show that for similar exposure conditions, the 54% chlorinated material produces more liver In jury than the 42% chlorinated material.
Other:
There are literature reports that PCBs can impair reproductive functions in monkeys. A study reported In the literature with female rats using Arodor * 1260 stated that Arodor 1260 caused liver cancers. Monsanto sponsored animal feeding studies of Arodor 1242, 1254 and 1260. These compounds, fed to both sexes of rats, did not produce cancers. The National Cancer Institute performed a study in 1977 using Arodor 1254 with both sexes of rats. NCI stated that the PCB. Aroclor f 254, was not carcinogenic under the conditions of their bioassay.
(Health Effects Summary Continued On Next Page)
HONS 003226
Potychtorlnatad Blphtnyis (PCBs)
TOWOLDMONOO11657 WATER_PCB-00004773
Monsanto material safety data
HEALTH EFFECTS SUMMARY (Continued)
Page 4 of s
The consistent finding in animal studies with PCBs is that they produce liver injury fol lowing prolonged and repeated exposure by any route, if the exposure is of sufficient degree and duration Liver injury is produced first, and by exposures that are less than those reported to cause cancer in rodents. Therefore, exposure by all routes should be kept sufficiently low to prevent liver injury.
Numerous epidemiological studies of humans, both occupationally exposed and non worker environmentally exposed populations, have not demonstrated any statistically significant causal relationship between PCB exposures and chronic human illnesses such as cancer or neurological or cardiovascular effects. Nor was there any increase in overall cancer mortality as a result of PCB exposure PCBs can cause dermatologi cal symptoms; however, these are reversible upon removal of exposure source.
PCBs are identified as hazardous chemicals under criteria ol the OSHA Hazard Com munication Standard (29 CFR Part 1910.1200). The Standard requires that this docu ment mention that PCBs have been listed in the International Agency for Research on Cancer (1ARC) Monographs (1982)-Group 2B and in the National Toxicology Program (NTP) Annual Report on Carcinogens (Third).
PHYSICAL DATA
Properties of Selected Aroclors*
Property Color (APHA) Physical state
101B
1221
40 100
mobile oil mobile oil
1232 100 mobile oil
1242 100 mobile oil
Stability
inert
inert
Density (Ib/gal 25'C)
11.40
9.85
Speckle gravity x/15.5*C
1.36*1.37 1.18-1.19
x*25
x-25
Distillation range CC)
323-356 275-320
Acidity mg KOH/g, maximum
.010 .014
Fire point rc)
none to boWng point
176
Flash point CC)
170
Vapor proMuro
NA
(mm Hg (' 100F)
141-150 NA
Viscosity (Saybdt Univ.
Sec. r 100'F)
7 i-ai
38-41
inert 10.55 1.27-1.28
x-258 290-325 .014
23B
152-154 0.005 44-51
inert 11.50
1.30-1.39 x-259
325-366
.015
none to boiling point 176-180
0.001
82-92
1248 100 mobile oil
inert 12.04
1254 100 V'SC0U8 liquid inert
12.82
1260 150
sticky resin
inert
13.50
1.40-1.41 x-65*
340-375
1.49-1 50 x-65
365-390
1.55-1.56 x-90
385-420
.010 .010
014
none to boiling point
193-196
none to boiling point
none
none to boiling point
none
0.00037 0.00006 NA
185-240 1800-2500 -
IVA - iVor Available
HONS 003227
MATERIAL SAFETY D A tA
TOWOLDMONOO11658 WATER_PCB-00004774
MATERIAL SAFETY DATA
Monsanto material safety data
SPILL, LEAK a. DISPOSAL INFORMATION
Page 5 of 6
Disposal of liquid PCBs and other PCB Items is strictly regulated by the federal government. The regulations are found at 40 CFR Part 761. Consult these regulations as well as applicable state and local regulations prior to any disposal of PCBs. PCB items, or PCB-contaminated items.
If PCBs leak or are spilled, the following steps should be taken immediately:
All non-essential personnel should leave the leak or spill area.
The area should be adequately ventilated to prevent the accumulation of vapors.
The spill/leak should be contained. Loss to sewer systems, navigable waterways and streams should be prevented. Spills/leaks should be removed promptly by means of absorptive material, such as sawdust, vermiculite, dry sand, clay, dirt or other similar materials, or trapped and removed by pumping or other suitable means (traps, drip-pans, trays, etc ).
Personnel entering the spill or leak area should be furnished with appropriate personal protective equipment and clothing as needed. See Occupational Control Procedures section Of this MSDS.
Personnel trained in the emergency procedures and protected against the attendant hazards Should shut oft sources of PCBs, dean up spills, control and repair leaks and fight fires in PCB areas.
All wastes and residues containing PCBs (e g., wiping cloths, absorbent material, used disposable protective gloves, clothing, etc.) should be collected, placed in proper containers, marked and disposed of in the manner prescribed by EPA regulations (40 CFR Part 761) and applicable state and local regulations.
Various federal, state, and local regulations may require reporting of PCB spills and may also define spill clean-up levels. Consult yout attorney or appropriate regulatory officials for Information relating to split reporting and spill clean-up.
ADDITIONAL COMMENTS* 5
Potvchlorlnatad Blphanvla
For regulatory purposes, under the Toxic Substances Control Act the term "PCBs" refers to a chemical substance limited to the biphenyl molecule that has been chlorinated lo varying degrees or any combination of substances which contain such substance (40 CFR Part TSl).
Chemically, commercial PCBs are defined as a series ol technical mixtures, consisting ol many isomers and compounds that vary from mobile oily liquids to white crystalline solids and hard non-crystalline resins. Technical products vary in composition, in the degree of chlorination and possibly according to
batch.
The mixtures generally used contain an average of 3 atoms ot chlorine per molecule (42% chlorine) to 5 atoms of chlorine per molecule (54% chlorine). They are used as components of dielectric fluids in transformers and capacitors. Prior to 1972, PCB applications included heat transfer media, hydraulic and other Industrial fluids, plasticizers, carbonless paper, paints, inks and adhesives. Federal regulations specify that non-totally enclosed PCB activities are permitted only if specifically exempted or authorized. (40 CFR Part 761).
CAS No. 001336363: For general class of compounds (AdditionalCommants Conlinuad On Next Page/
MQN5 003226
M ycM oriiM fd Biptmiyti (PCB*)
TOWOLDMONOO11659 WATER_PCB-00004775
Monsanto MATERIAL SAFETY DATAPage 6 of 6
ADDITIONAL COMMENTS (Continued)____________________________
Trad* Atom--/Common Name*
"ASKAREL- Generic name lor a broad class ol (ire-resistant synthetic chlorinated hydrocarbons and mixtures used as dielectric fluids that commonly contained about 30-70% PCBs. Some ASKAREL fluids contained 99% or greater PCBs.
PYRANOL' and INERTEEN5 are trademarks for commonly used dielectric fluids that may have contained varying ratios of PCBs as well as other components including chlo rinated benzenes.
*'Raglstarad trademark of Monsanto Company fisglstprad tradamark of Ganaral Eiactric Company --flaQlalarad trademark of Waitinghousa Eiactric Corporation
-- This list of trade names is representative of several commonly used Monsanto products (or formulated with Monsanto products). Other trademarked PCS products were marketed by Monsanto and other manufacturers. PCBs were also manufactured and sold by several European and Japanese companies. Contact the manufacturer of the trademarked product directly, if not in this listing, to determine II the formulation contained PCBs and its composition.
DATE: 10/15/85
REVISED:
SUPERSEDES: All prior to 10/15/85
MSDSNO.: Q404B
I FOR ADDITIONAL NON-EMERGENCY INFORMATION. CONTACT:
John H. Craddock Product & Environmental Safety Director
Robert G. Kaley, II Product & Environmental Safety Manager
Environmental Policy Staff Monsanto Company 800 North Lindbergh Boulevard St. Louis, Missouri 63167 (314) 894-4764
I
MATERIAL SAFETY DATA rW ) * Wor* M* ^
Although (ho information and roeommondoOont sot forth harain (htrainaftar "Information ) ara ptasanied In good faith and balawad to ba oorrtct aa of tho data haraof, Monsanto Company makaa no rapraaantaUona as to lha comptatanaaa <y accuracy tharaaf. Information it uppisd upon lha condition that lha psraont rtcafving sama wtl mafc# lhair am datarminatlon as to its suitably lor lhair purposaa prior to ust In no avant wtN Monsanto Company ba r#sponsfeia for damagta of any natura wfiataosvar rssulMng from ths uaa ol or raHanea upon Information. NO REPRESENTATIONS OR WARRANTIES. EITHER EXPRESS OP IMPLIED. OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER NATURE ARE MADE HEREUNOER WITH RESPECT TO INFORMATION OR THE PROQUCT TO WHICH INFORMATION REFERS.
KQNS 0032,29
TOWOLDMONOO11660 WATER_PCB-00004776
MATERIAL SAFETY DATA
Monsanto MATERIAL safety DATA
HONS 003230
TOWOLDMONOO11661 WATER_PCB-00004777
Potychtorlrmtwd B tptm iylt (PCBa)
MATERIAL SAFETY DATA Polychloii n f m i Biphmiyia (PCBm)
Monsanto material safety data
HONS 003231
TOWOLDMONOO11662 WATER_PCB-00004778