Document ypn7nwLwGDMmJ24RE0LJLXjRn
Monsanto
F*OM iSAME A LOCATION
R. M. Kountz - General Offices
June 23, 1969
SUBJECT
Aroclor incineration
TO .Dr. W. R. Richard
R. Davis R. E. Howard W. A. Kuhn D. A. Olson A. F. Pier
<(
In response to your note of June 3, we can get a sample
of combustion products from Thermal Research and Engineering
Corporation pilot plant tests. However, let me go further.
The test we had run was done in a laboratory burner which
is not arranged for getting gas samples but only to see if a
product burns. There was no charge for this test, and it was
run in their laboratory at Conshohoken (near Philadelphia),
Pennsylvania. Thermal Research and Engineering will run
'
a more extensive test in their pilot plant and provide analyses
or we can get gas samples for our analyses; however, they then
begin to talk in terms of $500/day charge. We have not committed
such a test since Dallas Armstrong's work has shown us the tempera
ture level at which Aroclor is destroyed.
Art Pier has found, while working with incineration vendors and contractors, that many incineration systems are designed to operate at 1,500F with retention of 0.3 to 0.6 seconds.
Thermal Research and Engineering says they design for a tempera ture in excess of 2,000F and retention is regulated.
We received notice recently that Mr. Hoffman of the Delaware River plant is negotiating an incineration contract for the plant chlorinated wastes. With Art's encouragement, they have dis cussed incinerating waste Aroclor. They see no problem, and Jim Bryant has sent them a sample of Aroclor for test.
Bill, I also have questioned the same point you have brought out and feel testing of combustion products will be required;
however, depending on when and where we ultimately have our in
cineration work done should conceivably influence our test work. If all are in agreement that we should proceed with Thermal
Research and Engineering, possibly Scott Tucker could attend the test at their laboratory and make the analysis on location
which should be more reliable.
i Following a meeting on June 13 with Howard Bergen, Bill Kuhn
and Paul Hodges, we will be pulling together information to
' evaluate a potential incineration system installation in the
St. Louis area.
.
-
R. M. Kountz
DSW 201010
STLCOPCB4059074