Document ypgbZzgNBQV78w6GXBO6Nr4Kr

INDEX BY ROCKBESTOS TABLE LETTER 300 VOLT All-Asbestos RANGE and APPLIANCE LEAD WIRES MOISTEMP t25C (257CF) Moistur*. Haat and1 Flam* Resisting Compound COPPER MONEL NICKEL A AM AN R RM RN Stove Wire (Solid)--Underwriters' Approved Stove Wire (Stranded)--Underwriters' Approved WBC WBCF WBCS WBM WBN WBMF WBNF WBMS WBNS 30 Mil Appliance Wire (Solid) 30 Mil Appliance Wire (Flexible Stranded) 30 Mil Appliance Wire (Coarse Stranded) wcc WCM WCN WCCF WCMF WCNF wees WCMS WCNS 40 Mil Appliance Wire (Solid) 40 Mil Appliance Wire (Flexible Stranded) 40 Mil Appliance Wire (Coarse Stranded) WDC WDM WDN WDCF W DMF WDNF WDCS WDMS WDNS 30 Mil Appliance Wire (Tripled - Solid) 30 Mil Appliance Wire (Tripled - Flex. Str.) 30 Mil Appliance Wire (Tripled - Coarse Str.) WEC WEM WEN WECF WEMF WENF WECS WEMS WENS 40 Mil Appliance Wire (Tripled Solid) 40 Mil Appliance Wire (Tripled Flex. Str.) 40 Mil Appliance Wire (Tripled - Coarse Str.) WSC WSCF -- -- -- -- Asbestos Insulated Wire (Solid) Asbestos Insulated Wire (Flex. Str.) WFC WFM WFN WFCF WFMF WFNF WFCS WFMS WFNS 33 Mil Hi-Dielectric Range Wire (Solid) 33 MU Hi-Dielectric Range Wire (Flex. Str.) 33 Mil Hi-Dielectric Range Wire (Coarse Str.) WGC WGM WGN WGCF WGMF WGNF WGCS WGMS WGNS 43 Mil Hi-Dielectric Range Wire (Solid) 43 Mil Hi-Dielectric Range Wire (Flex. Str.) 43 Mil Hi-Dielectric Range Wire (Coarse Str.) Grounding Wire HI-TEMP 200C (392F) Hat and Flam* Resisting Compound COPPER MONEL NICKEL A-300 AM-300 AN-300 R-300 RM-300 RN-300 XBC XBCF XBCS XBM XBMF XBMS XBN XBNF XBNS XCC XCCF XCCS XCM XCMF XCMS XCN XCNF XCNS XDC XDCF XDCS XDM XDMF XDMS XDN XDNF XDNS XEC XECF XECS xsc XSCF XEM XEMF XEMS -- -- XEN XENF XENS -- -- XFC XFCF XFCS XFM XFMF XFMS XFN XFNF XFNS XGC XGCF XGCS XGM XGMF XGMS XGN XGNF XGNS XI Page 14 14 8 8 8 9 9 9 10 10 10 10 10 10 11 11 12 12 M 12 13 1 13 7 300 VOLT Asbestos and Glass APPLIANCE LEAD WIRE Table AG Appliance Lead Wire (Glass Braided) 1000 VOLT APPLIANCE LEAD WIRE (Underwriters' Approved) Table FE Table FG Appliance and Range Wire (No Braid) Appliance and Range Wire (Glass Braid) GENERAL INFORMATION Standard Specifications for Rockbestos Range and Appliance Lead Wires Current-Carrying Capacities and Correction Factors District Sales Offices All Data Subject to change without notice. 15 1<S 2-6 7 Back Cover Catalog No. AW-55 (Rev. 58) Copyright 1955--5M Rockbestos Products Corporation ROCKBESTOS PRODUCTS CORPORATION Main Office and Works Nicoll and Canner Streets New Haven 4, Conn. printed in U. S. a. RBB 00536 THE QUESTION OF UNDERWRITERS1 APPROVED APPLIANCE AND LEAD WIRES Underwriters' Laboratories are primarily concerned with the fire and accident features of equipment, materials, devices and appliances. Their approvals and listings are given after exhaustive tests have been run by them on completed appliances or assemblies, judged solely on their safe performance as a unit. Underwriters' have not at the present time established standards for asbestos insulated wires to be used as internal wiring of appliances and devices. While they have made provisions to accept and test for approval some special insulated electrical conductors for specific appliance applica tions (for example the wires listed on pages 14, 15, and 1<S in this Catalog) their approval of asbestos insulated lead wire is based on its applica tion to a completed appliance or assembly which they will approve as a unit. Rockbestos has for more than thirty-five years manufactured asbestos insulated lead and appliance wires for all types of electrical appliances and devices. Underwriters' Laboratories through the years have approved many manufacturers' electrical appliances wired with the Rockbestos stand ard constructions listed in this catalog. Since the Underwriters' Laboratories Approval of an appliance is granted on the complete appliance and not on the component parts indi vidually, it must be clearly understood that because there are no Under writers' Standards for these types of wires, they cannot be Underwriters' Labeled. The recommendations for appliance wires that we make in this catalog are based on our long time experience that these constructions properly applied will successfully meet the requirements of the Under writers' Laboratories. These wires may also be used to conform to the standards for wiring required by the A.G.A. for gas range electrical cir cuits. Our Research and Design Engineers keep constantly abreast with special product applications as well as the many new unusually high temp erature insulation materials which can be of help to you. We offer you our research facilities for the development of special wires designed to meet any unusual requirements you may have. l SPECIAL INFORMATION ON RANGE AND APPLIANCE LEAD WIRES ROCKBESTOS RANGE AND APPLIANCE LEAD WIRES Important Information -- Read Before Specifying Before reviewing the Standard Specifications for Rockbestos Electric or Gas Ranee and Ap pliance Lead Wires a working knowledge of the types of impregnation used in the felted asbes tos and/or braid is essential. There are two basic types -- "Hi-Temp" which is heat and flame resisting, and "Moistemp" which is heat, flame, and moisture resisting. You should also knowsomething of the type of application in w-hich they should be used. "Hi-Temp" Impregnation -- Scope and Limits "Hi-Temp" impregnation is designed for applications in which the temperature is usual ly high and there is little or no moisture. A waffle iron suggests itself as a typical example as temperatures in them frequently range around 600F. Under such heat, and also because of high wattage and close confinement, moisture accumulated during the "off" period is dissipated before a leakage path or a short can develop. This condition is duplicated in many electrical products, but care must be exercised in determining whether the temperature rise is sufficiently rapid to dry out the insulation, as a slowly rising temperature will permit leakage to build up to a point where a short may occur. "Moistemp" Impregnation -- Scope and Limits "Moistemp" impregnation is designed for applications in which the temperature is high but not extreme, and where humidity and moisture may cause current leakage. This is par ticularly true of some appliances and devices in which the insulation on the ends of the wires attached to heating units is exposed to high temperatures, while the insulation on the wires between the terminals may be in a moist, low temperature area. In such applications "Mois temp" impregnation should be specified as it is not only heat and flame resistant but moisture resisting as well. High-Dielectric and Asbestos Insulation This type of insulation, employed in the .033" and .043" Hi-Dielectric Range and Ap pliance Lead wires shown on pages 12 and 13, is designed to meet conditions similar to those detailed in the paragraph above but more exaggerated, as in heavy duty appliances such as electric ranges, gas ranges and water heaters. The combination of tape and felted asbestos provides high resistance to both heat and moisture, and the asbestos may be impregnated with either "Hi-Temp" or "Moistemp" compound as required. ROCKBESTOS PRODUCTS CORPORATION 2 RBB 00538 R.OCKBESTOS STANDARD SPECIFICATIONS GENERAL -- CONDUCTORS STANDARD SPECIFICATION FOR ROCKBESTOS RANGE AND APPLIANCE LEAD WIRES Many companies in adopting Rockbestos Range and Appliance Lead Wires have requested suggestions for a standard specification. For this purpose we present the following outline which embraces all types of wire shown in this catalog. I General (a) Purpose: The purpose of this specification is to insure the furnishing of wire of the proper quality, manufactured in accordance with accepted practice. (b) Scope: This specification covers the construction and test requirements for ranee and appliance lead wires. (c) Materials and Workmanship: AH materials and workmanship employed in manu facturing wires to this specification shall be of high quality so as to provide a finished product best suited for the purpose intended. (d) Applications All-Asbestos Insulations. These wires are suitable for operation at a maximum of 300 volts as open wiring in high temperature applications where little or no moisture is encountered. Asbestos High-Dielectcic Insulations. These wires are suitable for operation at a maximum of 300 volts in electric ranges, gas ranges, hot water heaters or other appliances where they must oper ate under both heat and casual moisture conditions. The high dielectric tape in sert provides ample protection against casual moisture encountered within the appliance. II Conductors (a) Solid: Solid conductors shall be plain or coated copper in accordance with current ASA or ASTM specification. Other metals such as monel, nickel or copper clad soft steel per current NEMA Standard. (b) Stranded: Stranded conductors shall be bunched or concentric as required. The make-up of stranded conductors shall conform to current ASTM specifications. The individual strands shall be as specified for solid conductors in II (a). NEW HAVEN, CONNECTICUT 3 RBB 00539 STANDARD SPECIFICATIONS INSULATION -- SEPARATORS AND BRAIDS ROCKBESTos Standard Specification -- Continued III Insulation (a) Asbestos 1. Material: The asbestos insulation shall consist of selected quality, long fibre. chrvsotile asbestos commercially free from foreign particles of dirt, cotton seed and metallic oxides. It shall be well carded to prevent lumps and irregularities in the finished wire. The asbestos insulation shall be applied to form a smooth felted wall of uniform thickness as specified in the tables. The asbestos insulation after extraction of the impregnating compound shall contain not less than 805c bv weight of asbestos. The total iron content shall not exceed 4% by weight of the asbestos. 2. Impregnation-. The asbestos insulation shall be dried and saturated with a flame and heat resisting compound or a flame, heat and moisture resisting compound as specified. The compound shall consist of suitable high grade ingredients and shall retain its initial qualities during the normal life of the wire. The compound shall not develop any injurious chemical action within itself or with any component parts of the wire. (b) High Dielectric Tape-. The tape, when used, shall consist of a high grade material substantially free from blisters or other imperfections and shall be applied to form a smooth wall of uniform thickness. IV Separators Unless otherwise specified, suitable separators may be used. V Braids . (a) Asbestos 1. Material: The asbestos yam shall be of selected quality, long-fibre, chrysotile asbestos containing not less than 80% by weight of asbestos. The total iron content shall not exceed 6% by weight of the asbestos. 2. Application: Asbestos braids shall be applied to conform to current NEMA standards 3. Finish: Asbestos braid shall be finished with a suitable flame and heat resisting compound or saturated and finished with a flame, heat and moisture resisting compound as specified. ROCKBESTOS PRODUCTS CORPORATION 4 RBB 00540 ROCKBESTOS STANDARD SPECIFICATIONS TESTS -- PHYSICAL -- ELECTRICAL Standard Specification -- Continued VI Tests A. Physic.it L. Dimensions-. Inspection for dimensional requirements shall consist of four deter minations. two to be made near each end of the sample of which the average shall comply with the requirements given in the tables. The measurements shall be made with a ratchet micrometer having 1 -i inch diameter faces. Each determination shall be the average of two measurements made at tight angles to each other. 2. Resistance to Flame: All wire made to this specification shall have fire resisting properties so that the test specimens will meet aii of the requirements of the Underwriters' Laboratories standard vertical fiame test. B. Elect-, teal 1. lniti.il Dielectric Strength: Initial dielectric strength tests shall be made on 5-foot lengths of finished wire with the center 3*foot section wrapped in metal foil. Voltages as indicated below shall be applied for 1 minute. (1) All-Asbestos, flame and heat resistant, plain or braided -- 1000 volts. (2) All-Asbestos, flame, heat and moisture resistant (3) Asbestos-High Dielectric -- 2500 volts. / I000\olc$. L braided --1500 volts. 2. Dielectric Strength after Flame: A sample of wire having been previously subjected to the flame test shall be pre pared with the charred area of sizes No. 6 and larger wrapped in metal foil, and sizes smaller than No. 6 buried in iron filings or fine shot. The sample shall then withstand the application of 1000 volts for 1 minute when applied between con ductor and ground. 3. Bend-Dielectric Strength: A sample of wire shall be wound 5 turns around a mandrel having a diameter 5 times that of the sample. The ends of the spiral shall be held tightly by a medianical anchorage. Metal foil shall be tightly wrapped over the entire length of the spiral. The sample shall then withstand 1500 volts for 1 minute when applied be tween conductor and metal rod and foil. 4. Dielectric Strength While Immersed (Flame, heat and moisture resistant type only): A 2-foot sample of finished wire shall have the center 1-foot section immersed for l hour in tap water at room temperature. While still immersed the sample shall withstand 1000 volts for 1 minute when applied between conductor and water. NEW HAVEN, CONNECTICUT 5 RBB 00541 STANDARD SPECIFICATIONS TESTS--ELECTRICAL AND SAMPLING ROCKBESTQs Standard Specification -- Continued 5. Dielectric After Heating in Oven: A sample of wire shall be wound 5 turns around a mandrel having a diameter 5 times chat of the sample. The ends of the spiral shall be held tightly by a mechan ical anchorage. The sample thus wound shall be placed in an oven at a temperature of -H0CF. ( = 20CF.) until the wire ceases to smoke but for not less than l hour. The sample shall be removed from the oven and metal foil shall be tightly wrapped over the entire length of the spiral. The sample shall then withstand 1000 volts for l minute when applied between conductor and metal rod and foil. 6. Heat and Water Test (Asbestos-High Dielectric type only): A 6-toot sample of wire shall be given a dielectric test by winding the center 5 feet on a brass mandrel having a diameter five times the diameter of the insu lated wire or 1A inch, whichever is greater. Place the sample on the mandrel into an oven heated at 17~CC. = 2C. (350F. = -icF.) for a continuous period of 5 hours. After the duration of the heating period, remove the sample and allow it to return to room temperature. With the exception of the 6" section at each end. soak the sample, for a period of 5 hours, in a brine solution consisting of 0.1 grams of sodium chloride per liter of tap water. Immediately after removal from the brine solution, the sample shall withstand 1200 volts, 60 cycles, applied for 1 minute between the conductor and the mandrel. Dielectric Strength (Grounding Wire Only) A 6-foot sample of wire shall be given a dielectric test by winding the center hve feet on a brass mandrel having a diameter five times the diameter of the insu lated wire. Place the sample on the mandrel into an oven heated at 177C. = 2CC. (3503F. = 4F.) for a continuous period of 5 hours. After the duration of the heating period, the sample shall be removed and shall be subjected immediate ly to and shall withstand 500 volts, 60 cycles for 1 minute between the conductor and the mandrel. VII Sampling (a) Each of the required tests shall be made on one sample of each size and type of wire from each lot of 10,000 feet or fraction thereof. (b) If a sample fails to meet a prescribed test requirement, two additional samples shall be taken from the same length. If the two additional samples meet the test requirement then the lot shall be accepted. If either of these samples fail the length may be rejected. (c) If any length is rejected for failure to meet a requirement, then a sample shall be taken from each length of the balance of the lot and subjected to the particular test requirement to determine acceptance or rejection of that length. \ I ROCKBESTOS PRODUCTS CORPORATION 6 RBB 00542 rockbestos CURRENT CARRYING CAPACITIES CORRECTION FACTORS GROUNDING WIRE CURRENT-CARRYING CAPACITIES FOR ASBESTOS INSULATED COPPER NICKEL AND MONEL CONDUCTORS USED FOR LEADS TO APPLIANCES AND OTHER EQUIPMENT (BASED ON INSTALLA TION EQUIVALENT TO THREE 1-CONDUCTOR WIRES IN CONDUIT). i Current-Carrying Capacities, Amperes* -- per NEMA Standard _, Condr. Size. A.W.G. : ROCKBESTOS "MOISTEMP" INSULATION ROCKBESTOS "HI-TEMP" INSULATION Heat and Moisture Heat -- No Moisture Max. Conductor Temp. 125C Max. Conductor Temp. :---------------------------------------------------------------------------------------------------------------------------------------------- ------------------ ; 200 C. 300 C. *00 C. : Copper Nickel Monel Copper Nickel Monel IS 16 14 12 10 8 6 4 3 *> I 17 ' "t "> 29 38 49 63 85 114 131 U7 172 7.1 9.2 12.1 16.0 20.6 26.4 36.0 48.0 55.0 62.0 72.0 4.1 5.4 7.1 9-3 12.0 15.4 20.7 27.9 32.0 36.0 42.0 ; 18 23 32 42 54 7l 95 122 145 163 188 8.5 10.9 l\2 20.0 25.6 33." 45.0 57.9 68.8 77.4 88.2 s.2 6.6 9.1 12.9 15.5 20.3 *)7 "> 3V0 4lA 46.6 >3.7 Use 80 per cent ot these current ratings when 4 to 6 conductors are laid dose together. and "0 per cent tor ' ;o -) conductor*. CURRENT CORRECTION FACTORS FOR VARIOUS AMBIENT TEMPERATURES , Ambient Temp. C. 30 40 50 60 "0 SO 90 100 120 140 ' Correction Factors Rockbestos "Hi-Temp" -------------------------------------------------------------------------- Rockbestos "Moistemp" Copper Nickel and Monel 1.00 : * ** 0.95 *** *** #** : 0.89 1.00 i 1.00 : 0.83 0.97 0.98 : 0.76 : 0.93 0.96 0.69 0.89 0.94 j 0.61 0.S6 ; 0.92 = 0.51 0.82 ! 0.90 1 *** 0.72 | 0.85 { *## : 0.63 1 0.80 ALL-ASBESTOS APPLIANCE GROUNDING WIRE (NEMA Standard--1954) 5^ Construction: Stranded copper conductor. felter asbestos insulation, green finish, no braid. The insulation is impregnated with "Hi-Temp" heat and flame resisting compound. TABLE XI i | j Size | A.W.G. 1 Stranding . Bare i Diameter | Inches ': Nominal 'Nominal ; Felted Wail Mils Diameter i Inches j . Approx. , In Lbs. j 1000 Feet | Standard Package (Feet) 1 Non-Returnable i Large Metal Coils 1 Spools Wooden Reels 14 | 7/.0242 j .073 15 ! .103 1 16 , 1000 i 3000 5000 Finished diameter given above is average. A tolerance of plus or minus Sic is necessary due to variations in process of manufacture. NEW HAVEN, CONNECTICUT 7 rBB 00543 .030 APPLIANCE LEAD WIRES COPPER, NICKEL OR MONEL SOLID OR STRANDED CONDUCTORS 300 VOLT ALL-ASBESTOS .030" APPLIANCE LEAD WIRES FOR WAFFLE IRONS. HOTPLATES. FLAT IRONS. ROASTERS. GRILLS. TOASTERS COFFEE BREWERS. FOOD WARMERS. FRIERS. CONTROL PANELS. SWITCH BOARDS. WRAPPING SEALERS. COIL. MOTOR AND APPARATUS LEADS MAXIMUM OPERATING TEMPERATURES: HI-TEMP--200cC. (392CF.) MOISTEMP--125;C. (25'-'F.) SOLID STRANDED 3 5 "HI-TEMP'* Insulation--Heat and Flame resisting--For use in High Temperatures, little or no moisture. 'MOISTEMP" Insulation--Heat. Flame and Moisture resisting--Use for Heat and Moisture conditions. Conductors--Solid or Stranded Copper, Nickel or Monel--Insulated with .030" of felted asbestos. icecmed statvi.ud conductors ire insulated with in .030" wall or felted asbestos impregnated with either "Hi-Temp" heat and dame resisting compound or "Moistemp" heat, dame and moisture resisting compound. Standard colors: black, white and red. Gray, green, blue, orange, brown and yellow available on special order. Special conductors such as tinned copper, copoerweld. and alloys other than nickel or monel can be supplied on special order. When ordering oe sure to specify color and give table letters indicating tvpe of conductor wanted and preference for cither Hi-Temp or "Moistemp" impregnation. Solid Moistemp: Solid Hi-Temp: Size A.W.G. 8' 10 ; 12 U 16 IS 20 Bare Diameter Inches .128 .102 .081 .064 .031 .040 .032 Table WBC-- Copper Table XBC --Copper Table WBM--Monel Table XBM --Monel Table WBN -- Nickel Table XBN --Nickel Nominal Thickness ' Felted Wall . r Inches ; .030 i .030 1 ' .030 : .030 : .030 .030 : ; .030 'Nominal Finished Diameter Inches .188 .162 .141 .124 .III .100 092 , Approx. \ Net Weight ! In Lbs. j Per 1000 Feet ! 60 j 39 1 27 ' 18 13 ; 10 ;7 Stan iard Package (Feet) Non-Returnable Coils 500 1000 1000 1000 1000 1000 1000 Large Metal Spools _ 1000 1500 2500 3500 5000 5000 Wooden Reels 5000 6500 S<00 10000 10000 10000 10000 Coarse Stranded Moistemp: Coarse Stranded Hi-Temp: Table WBCS -- Copper Table XBCS --Copper Table WBMS --- Monel Table XBMS -- Monel Table WBNS -- Nickel Table XBNS -- Nickel Size A.W.G. Stranding Bare Diameter Inches Nominal Thickness Felted Wall Inches Nominal Finished Diameter Inches Approx. Net Weight In Lbs. Per 1000 Feet Standard Package (Feet) Coils Large Metal Spools Reels S " ,04S<> 10 " .0383 12 " .0503 \ 4 . " .0242 16 ' .0192 IS * .0152 20 7 .0121 .146 .116 .092 .073 .058 .046 .036 .030 .030 .030 .030 .030.030 .030 .206 .176 .152 .133 .118 .106 .096 62 500 4000 42 1000 1000 6000 28 1000 1500 7500 19 1000 2500 10000 14 1000 3500 10000 9 1000 4500 10000 8 1000 5000 10000 Flexible Stranded Moistemp: Flexible Stranded Hi-Temp: Table WBCF-- Copper TableXBCF -- Copper Table WBMF -- Monel Table XBMF -- Monel Table WBNF -- Nickel Table XBNF -- Nickel 8 165 30 10 ; 104 30 12 j 65/30 14 i 41.30 16 i 26'30 IS ; 16/30 20 | 10/30 .151 .120 .095 .075 .059 .045 .038 .030 .030 .030 .030 .030 .030 .030 .211 ISO .155 .135 .119 .105 .093 64 500 _ 4000 43 1000 1000 6000 29 1000 1500 7500 19 1000 2500 LOOOO 14 1000 4000 10000 10 1000 4500 10000 7 1000 5000 10000 "finished diameter given above is average. A tolerance of plus or minus S?0 ij necessary due to variations in process of manufacture. ROCKBESTOS PRODUCTS CORPORATION _____ _________________ _.. . . s RBB 00544 300 VOLT ALL-ASBESTOS .040" APPLIANCE LEAD WIRES FOR RANGES. WATER HEATERS. PORTABLE RHEOSTATS. BLUEPRINT MACHINES. LABORATORY OVENS. DRYERS. STERILIZERS. COMMERCIAL COFFEE BREWERS, BROILERS. TOASTERS AND GRILLS. CAR AND SPACE HEATERS, IRON'ERS. ETC. MAXIMUM OPERATING TEMPERATURES: HI-TEMP--200CC. (392F.) MOISTEMP--I25C. (257fiF.) .040' APPLIANCE LEAD WIRES COPPER, NICKEL OR MONEL SOLID OR STRANDED CONDUCTORS SOLID STRANDED "HI-TEMP" Insulation--Heat and Flame resisting--For use in High Temperatures, little or no moisture. "MOISTEMP" Insulation--Heat, Flame and Moisture resisting--Use for Heat and Moisture conditions. Conductors--Solid or Stranded Copper, Nickel or Monel--Insulated with .040" of felted asbestos. Specified standard conductors are insulated with an ,040" wall of felted asbestos impregnated with either "Hi-Temp" heat and flame resisting compound or "Moisremp" heat, flame and moisture resisting compound. Standard colors: black, white and red. Gray, green, blue, orange, brown and yellow on special ocder. Special conductors such as tinned cooper, coppecweld, and alloys other than nickel or monel can be supplied on special order. When ordering be sure to give table letters indicating type of conductor wanted, also specify color and preference for either 'Hi-Temp" or "Moistemp" impregnation. Solid Moiscemp*. Solid Hi-Temp: Table WCC -- Copper TableXCC --Copper Table WCM -- Monel Table XCM -- Monel Table WCN -- Nickel Table XCN -- Nickel Size A.W.G. 8 10 12 14 16 18 20 Diameter Inches .128 .102 .081 .064 .051 .040 .032 Nominal Thickness Felted Wall Inches .040 .040 .040 .040 .040 .040 .040 Nominal Finished Diameter Inches .208 .182 .161 .144 151 .120 .112 | ) Approx. 1 Net Weight j In Lbs. j Per 1000 Feet 1 64 ! 43 i 30 ! 21 ! 16 1 12 !9 Scant ard Package (Feet) Non-Returnable Coils 500 1000 1000 1000 1000 1000 1000 Large Metalt Spools : .- ; 1000 1500 2500 2500 4000 4000 i ! : | Wooden Reels 4000 5000 6>00 8500 10000 10000 10000 Coarse Stranded Moistemp: Table WCCS -- Copper Table WCMS -- Monel Table WCNS -- Nickel Coarse Stranded Hi-Temp: Table XCCS -- Copper Table XCMS -- Monel Table XCNS -- Nickel Size A.W.G. 8 10 12 U 16 IS 20 Stranding - .0486 ' .0385 ~ .0505 7 .0242 7 .0192 7 .0152 7-.0121 Bate Diameter Inches .146 .116 .092 .073 .058 .046 .036 Nominal Thickness Felted Wall Inches .040 .040 .040 .040 .040 .040 .040 Nominal Finished Diameter Inches .226 .196 .172 .153 .138 .126 .116 Approx. Net Weight In Lbs. Pet 1000 Feet 67 46 32 23 16 12 10 Scant iard Package (Feet) Non-Returnable Coils Spools Large Metal Wooden Reels 500 1000 1000 1000 1000 1000 1000 . 1000 1500 2000 2500 5000 4000 3500 4500 6000 7500 10000 10000 10000 Flexible Stranded Moistemp: Table WCCF -- Copper Table WCMF -- Monel Table WCNF--Nickel Flexible Stranded Hi-Temp: Table XCCF -- Copper Table XCMF -- Monel Table XCNF -- Nickel S 165 oO to 104/30 12 65/ 30 14 41/30 16 26/30 IS 16/30 20 10/30 .151 .120 .095 .075 .059 .045 .038 .040 .040 .040 .040 .040 .040 .040 .231 .200 .175 .155 .139 .125 .118 68 500 _ 3000 46 1000 1000 4500 32 1000 . 1500 6000 22 1000 2000 7500 16 1000 2500 10000 12 1000 3000 10000 10 1000 4000 10000 Finished diameter given above is avenge. A tolerance of plus or minus 5% is necessary due to variations in process of manufacture. NEW HAVEN, CONNECTICUT 9 RBB 00545 .030 OR .040 TRIPLED APPLIANCE LEAD WIRES COPPER, NICKEL OR MONEL SOLID OR STRANDED CONDUCTORS 300 VOLT ALL-ASBESTOS TRIPLED APPLIANCE LEAD WIRES FOR ELECTRIC RANGES AND OTHER HEAT GENERATING EQUIPMENT IN WHICH A TRIPLED LEAD WIRE CONSTRUCTION IS PREFERRED TO SINGLE CONDUCTORS. MAXIMUM OPERATING TEMPERATURES: HI-TEMP--2Q0=C. (392-F.) MOISTEMP--125?C. (25--'F.) SOLID STRANDED "HI-TEMP" Insulation--Heat and Flame resisting--For use in High Temperatures, little or no moisture. "MOISTEMP" Insulation--Heat, Flame and Moisture resisting--Use for Heat and Moisture conditions. Conductors--Solid or Stranded Copper, Nickel or Monel--Insulated with .030" or .040" of felted asbestos. Specified standard conductors ace insulated with an .050" oc 0-0" wall of felted asbestos impregnated with either 'Hi-Temp" heat and flame resisting compound or Moistemp'' heat, flame and moisture resisting compound, polarized with black, white and red finishes, and tripled. Special conductors such as tinned copper, copperweld and alloys other than nickel or monel can be supplied on special order. When ordering be sure to give table letters indicating type of conductor and insulation thickness wanted .mu specify preference for either "Hi-Temp" or 'Moistemp ' im pregnation or other colors. The Hi-Dielectr:c Range and Lead Wires on the following pages are also rrieitd if desired. ' .030" Solid Moistemp: .030" Solid Hi-Temp: .040" Solid Moistemp: .040" Solid Hi-Temp: Size A.W.G. \z 14 16 IS Bare Diameter Inches .081 .064 .051 .040 Table WDC--Copper Table XDC--Copper Table WEC--Copper Table XEC--Copper Nominal Finished Diameter** (Inches) .030" .303 .267 .239 .215 .040" .346 .310 .282 .258 Table WDM--Monel Table XDM--Monel Table WEM--Monel Table XEM--Monel Approx. Net Weight Per M Ft. (Pounds) .030" S3 57 40 30 .040" 92 65 47 35 Table WDN--Nickel Table XDN--Nickel Table WEN--Nickel Table XEN--Nickel Standard Package (Feet) Coils 250 250 300 500 Wooden Reels 1'00 2000 2000 2^00 .030" Coarse Stranded Moistemp: .030" Coarse Stranded Hi-Temp: .040" Coarse Stranded Moistemp: .040" Coarse Stranded Hi-Temp: Size A.W.G. 12 U 16 IS Stranding ~ .0505 ' .0242 " .0192 ~ '.0152 Bare Diameter Inches .092 .073 .058 .046 Table WDCS--Copper Table XDCS--Copper Table WECS--Copper Table XECS--Copper Nominal Finished Diameter* (Inches) .030" .327 .286 .254 .228 j i i .040" .370 .329 .297 .271 Table WDMS--Monel Table WDNS--Nickel Table XDMS--Monel Table XDNS--Nickel Table WEMS--Monel Table WENS--Nickel Table XEMS--Monel Table XENS--Nickel Approx. Net Weight Per M Ft. (Pounds) i Standard Package (Feet) .030" .040" Coils i Wooden Reels 89 98 , 250 , 1000 61 71 ' 250 1500 43 52 ! 500 ' 2000 34 40 ; 500 2300 .030" Flexible Stranded Moistemp: Table WDCF--Copper Table WDMF--Monel Table WDNF--Nickel .030" Flexible Stranded Hi-Temp: Table XDCF--Copper Table XDMF--Monel Table XDNF--Nickel .040" Flexible Stranded Moistemp: Table WECF--Copper Table WEMF--Monel Table WENF--Nickel .040" Flexible Stranded Hi-Temp: Table XECF--Copper Table XEMF--Monel Table XENF--Nickel 12 65'50 .095 .354 i .377 i 89 98 250 1000 14 41 -30 .075 -290 j .334 i 60 68 250 1500 16 26/50 .059 .256 [ .299 ! 43 50 500 2000 18 16/30 .045 .226 1 .269 1 31 37 500 2500 `Finished diameter given above is average. A tolerance of plus or minus l?a is necessary due to variations in pcoceu of manufacture. ROCKBESTOS PRODUCTS CORPORATION 10 RBB 00546 300 VOLT ASBESTOS INSULATED WIRES NEMAf TYPES A and AI "MOISTEMP" INSULATION--FOR RANGES. WATER HEATERS. APPLIANCES AND APPARATUS REQUIRING WIRE HIGH IN DIELECTRIC STRENGTH AND RESIST ANCE TO HEAT. HUMIDITY AND MOISTURE. "HI-TEMP" INSULATION--FOR APPLIANCES REQUIRING ONLY A HEAT AND FLAME RESISTANT INSULATION. . NEMA TYPES A and AI ASBESTOS INSULATED WIRES SOLID OR STRANDED CONDUCTORS MAXIMUM OPERATING TEMPERATURES: MOISTEMP--1253C. (257F.)--NEMA TYPE AI HI-TEMP--200CC. (392F.)--NEMA TYPE A -NEMA Standard WC-l. 1953 lists Types A and At in >0 and 40 mils of asbestos insulation, plus a separator if used. The "Moistemp" constructions shown with and t3 mils of insulation have a 3 mil dielectric tape insert plus the 30 and -tO mil NEMA Standard insulation. STRANDED OR SOLID 'MOISTEMP" Insulation--Heat, Flame and mois ture resisting--Use for Heat and moisture condi tions. TABLE WSC--Solid Copper Conductor. TABLE WSCF--Stranded Copper Conductor. "HI-TEMP" Insulation--Heat and Flame resisting --Use for High Temperatures, little or no moiscure. TABLE XSC--Solid Copper Conductor. TABLE XSCF--Stranded Copper Conductor. HOW and WHERE TO SPECIFY EITHER "MOISTEMP' or "HI-TEMP" INSULATIONS These NEMA Type Appliance wires are furnished in two basic types of impregnations'''MOISTEMP" impregnation in the felted wall is designed for applications where the temperature is high but not extreme, and where humidity and moisture may cause current leakage. For example, in some appliances and devices the insulation at the ends of the wires attached to heating units is exposed to high temperatures while the rest of the wire run may be m a moist, lower temperature area. For these applications specify "Moistemp" impregnation as it is not only heat and dame resistant but moisture resisting as well. "HI-TEMP'' Impregnation in the felted wall is heat and dame resisting and designed for applications where the tem perature is usually high with little or no moisture Under heat, and because of high wattage and dose confinement, moisture accumulated during the "off" period is dissipated before a leakage path oi short can develop. This condition exists in many products, but care must be exercised in determining whether the temperature rise is sufficiently rapid to dry out the insulation, as a slowly rising temperature will permit leakage to build up to a point where a short may occur. Moistemp: Solid Table WSC -- Copper High dielectric tape and felted asbestos insulation totaling 43 mils on Sizes 8-10-12; 33 mils on Size 14. Size A.W.G. Stranding Bare Diameter Inches Nominal Finished Diameter Inches Approx. Net Weight In Lbs. Per 1000 Feet Standard Package (Feet) Non-Returnable Large Metal Wooden Coils Spools Reels 14 Solid .064 12 Soiid .081 10 Soiid .101 8 Solid .128 .130 .167 .188 .214 24 , 1000 2500 10000 38 1000 1500 6500 54 i 1000 1000 5000 79 | 500 -- 4000 Moistemp: .Stranded 14 41 50 12 65 50 10 105 30 S ld5 30 : Table WSCF --Copper .075 .141 .095 .181 .120 .206 .176 .237 Same insulation note as above. 25 1000 2000 40 ; 1000 1500 57 ; iooo 1000 85 ; 500 -- 8500 5000 4000 3000 Hi-Temp: Solid Table XSC --Copper 40 mils of felted asbestos on Sizes 8-10-12; 30 mils of felted asbestos on Size 14, 14 Solid .064 i 12 . Solid i .081 > 10 Soiid 1 .101 : 8 Solid .128 j .124 .161 .182 .208 21 . 1000 2500 36 1000 1500 51 i 1000 1000 76 1 500 ; -- 10000 6500 5000 4000 Hi-Temp: Stranded Table XSCF -- Copper Same insulation note as above. 14 41-30 .075 12 65'30 .095 10 105/30 .120 8 165, 30 .176 .135 22 I 1000 i 2500 .175 .: 38 j 1000 1500 .200 : 55 ! iooo ! 1000 .231 . 81 i 500 --: Finished diameter given above is average. A tolerance of plus or minus i% is necessary due to variation* in proem of manufacture. 10000 6000 4500 3000 NEW HAVEN, CONNECTICUT a RBB 00547 1rn HI-DIELECTRIC .033' RANGE AND APPLIANCE LEAD WIRES COPPER, NICKEL OR MONEL SOLID OR STRANDED CONDUCTORS 300 VOLT HI-DIELECTRIC .033 (NEMA STANDARD) RANGE AND APPLIANCE LEAD WIRES TOR ELECTRIC RANGES. WATER HEATERS. APPLIANCES AND \P3Rv QLTRING A WIRE WHICH IS HIGH IN DIELECTRIC STRENGTH \\D ANCE TO HEAT. HUMIDITY AND MOISTURE. '' MAXIMUM OPERATING TEMPERATURES: HI-TEMP--200;C. (392-F.) MOISTEMP--125CC. (25rcF.) 3 SOLID OR STRANDED "HI-TEMP" Insulation--Heat 3nd Flame resisting--For use in High Temperatures, little or no moisture. "MOISTEMP" Insulation--Heat. Flame and Moisture resisting--Use for Heat and Moisture conditions. Conductors--Solid or Stranded Copper, Nickel or Monel--Insulated with high dielectric tape and felted asbestos to a combined thickness of .033". frcohcJ standard conductors are insulated with meh-Jiclec- trie taoe and felted jsbestos to a combined thickness of .033" to provide high resistance to both heat and moisture. The asbestos insulation is impregnated with either "Hi-Temp" heat and dame resisting compound or "Moistemp" heat, dame inJ moisture resisting compound as speciried. Standard colors: biack, white and red. Grav. green, blue, orange, brown and .?ilow nn special order. When ordering be sure to specify color and give table Setters indicating type of conductor wanted and preference for either "Hi-Temp" or 'Moistemp .mprv.c nation. The Range and Appliance lead wires listed on :hi' race meet all requirements of the latest NEMA STANDARDS FOR ASBESTOS INSULATED RANGE WIRE. Special conductors such .-.s tinned copper, copperwcld ,.r.o alloys other than nickei . ; monel can be supplied on >rec:ui order. Also made up irv tripled construction like toe wire' illustrated on page 10. Solid Moistemp: Solid Hi-Temp: Table WFC--Copper Table XFC --Copper Table WFM--Monel Table XFM --Monel Table WFN -- Nickel Table XFN --Nickel Size : A.W.G. Bare Diameter Inches Nominal Thickness Tape and relied Wail Inches j : j 1 J Nominal Finished Diameter Inches | Approx. \ Net Weight In Lbs. Per 1000 Feet Stan lard Package (Feet) Non-Returnable Coils Large Metal Spools Wooden Reels **10 !! 2 14 16 IS .102 .081 .064 .03 1 .040 .033 .033 -033 .033 .033 j J 1 1 .168 .147 .130 .117 .106 j i : 43 29 20 14 11 1000 1000 1000 1000 tooo 1000 1500 2500 3500 4300 cs'00 8*00 [0000 10000 10000 Coarse Stranded Moistemp: Table WFCS -- Copper Table WFMS -- Monel Table WFNS -- Nickel Coarse Stranded Hi-Temp: Table XFCS --Copper Table XFMS --Monel Table XFNS --Nickel Size A.W.G. :-I0 * * 12 14 16 13 . Stranding ' .0585 7 .0305 .0242 7 .0192 7 '.0152 Bare Diameter Inches .116 .092 .073 .058 .046 Nominal Thickness Tape and Felted Wall Inches 033 033 .033 .033 .033 Nominal Finished Diameter Inches .182 .158 .139 .124 .112 Approx. Net Weight In Lbs. Per 1000 Feet 44 31 21 15 12 Standard Package (Feet) j Non-Returnable Coils Large Metal Spools Wooden Reels 1000 1000 1000 1000 1000 tooo 1500 2000 3000 4000 5000 7500 10000 10000 10000 Flexible Stranded Moistemp: Flexible btranded Hi-Temp: Table WFCF-- Copper Table XbUh -- Copper Table WFMF --- Monel Table XFMF --- Monel Table WFNF -- Nickel Table XFNF -- Nickel 'no * * 12 U 16 18 i , ' i 104'30 65 30 41-30 26/30 16 -TO .120 .095 .075 .059 .045 .033 033 .033 .033 -033 .186 .161 .141 .125 .Ul 46 1000 1000 5000 31 1000 1500 6500 21 1000 2000 8500 15 1000 5000 10000 u 1000 4000 10000 'finished diimeter Riven shove it avcrai*. A tolerance of plus or minus 5% is necessary due to variations in process of manufacture. "These sizes not NEMA Standard--NEMA requires 40 mils insulation for these sizes. See page.lt. ROCKBESTOS PRODUCTS CORPORATION 12 RBB 00548 300 VOLT HI-DIELECTRIC .043" RANGE AND APPLIANCE LEAD WIRES FOR ELECTRIC RANGES. WATER HEATERS, APPLIANCES AND APPARATUS REQUIRING A WIRE WHICH IS HIGH IN DIELECTRIC STRENGTH AND RE SISTANCE TO HEAT, HUMIDITY AND ' lOfSTL'RE. MAXIMUM OPERATING TEMPERATURES: HI-TEMP--200C. (392CF.) MOISTEMP--125C. (257F.) HI-DIELECTRIC .043' RANGE AND APPLIANCE LEAD WIRES COPPER, NICKEL OR MONEL SOLID OR STRANDED CONDUCTORS c:.,: SOLID OR STRANDED ft ' HI-TEMP" Insulaiior--Heat and Flame resisting--For use in High Temperatures, little or no moisture. "MOISTEMP" Insulation--Heat, Flame and Moisture resisting--Use foe Heat and Moisture conditions. Conductors--Solid or Stranded Copper, Nickel or Monel--Insulated with high dielectric tape and felted asbestos to a combined thickness of .043". Specified standard conductors are insulated with high-dielec tric tape and felted asbestos to a combined thickness of .043" to provide high resistance to both heat and moisture. The asbestos insulation is impregnated with either "Hi-Temp" heat and flame resisting compound or "Moistemp" heat, flame and moisture resisting compound as specified. Standard colors: black, white and red. Gray, green, blue, orange, brown and yellow on special order. When ordering be sure to specify color and give table letters indicating type of con Solid Moistemp: Solid Hi-Temp: Table WGC -- Copper Table XGC -- Copper ductor wanted and preference for either "Hi-Temp" or "Moistemp" impregnation. The Range and Appliance Lead wires listed on this page meet the test requirements for the latest NEMA STAND ARDS FOR ASBESTOS INSULATED RANGE WIRE. Special conductors such as tinned copper, copperweld and alloys other than nickel or monel can be supplied on special order. Also made up in tripled construction like the wires illus trated on page 10. Table WGM -- Monel Table XGM -- Monel Table WGN--Nickel Table XGN -- Nickel Size A.W.G. Bate Diameter Inches Nominal Thickness Tape and Felted Wall Inches Nominal Finished Diameter Inches B .128 10 .102 12 .081 U .064 16 .051 IS .040 .043 .043 .043 .043 .043 .043 .214 .188 .167 .150 .137 .126 Coarse Stranded Moistemp: Table WGCS -- Copper Coarse Stranded Hi-Temp: Table XGCS --Copper Approx. Net Weight Iq Lbs. Per 1000 Feet 66 45 32 22 16 13 Stan laid Package (Feet) Non-Returnable Coils 500 1000 1000 1000 1000 1000 Large Metal Spools _ 1000 1500 2000 2500 3000 Wooden Reels 4000 5000 6500 8500 10000 10000 Table WGMS-- Monel Table WGNS-- Nickel Table XGMS --Monel Table XGNS --Nickel Size A.W.G. 8 10 12 14 16 IS Stranding 7 .0486 7 .0385 7 '.0305 7.'.0242 7 .0192 7 '.0152 Bare Diameter Inches .146 .116 .092 .073 .058 .046 Nominal Thickness Tape and Felted Wall laches .043 .043 .043 .043 .043 .043 Nominal Finished Diameter Inches .232 .202 .178 .159 .144 .132 Approx. Net Weight In Lbs. Per 1000 Feet 69 48 34 24 17 13 Stan tard Package (Feet) Non-Returnable Coils Large Metal Spools Wooden Reels 500 1000 1000 1000 1000 1000 1000 1500 2000 2500 2500 3000 4000 6000 7500 8500 10000 Flexible Stranded Moistemp: Table WGCF -- Copper Flexible Stranded Hi-Temp: Table XGCF -- Copper Table WGMF -- Monel Table XGMF -- Monel Table WGNF -- Nickel Table XGNF -- Nickel _8 165/30 .151 .043 .237 71 500 3000 10 104/30 .120 .043 .206 48 1000 1000 4000 12 65/30 .095 .043 .181 34 1000 1500 5000 14 41/30 .075 .043 .161 23 1000 2000 6500 16 26/30 .059 .043 .145 17 1000 2500 8500 t 18 16/30 .045 .043 .131 13 1000 2500 10000 * Finished diameter given above * average. A tolerance of plus or minus 5% is necessary due to variation* in process of manufacture. NEW HAVEN, CONNECTICUT U RBB 00549 U. L APPROVED STOVE WIRES COPPER, NICKEL OR MONEL SOLID OR STRANDED CONDUCTORS "MOISTEMP"--"HI-TEMP" 300 VOLT ALL-ASBESTOS Underwriters' Approved STOVE WIRES < FOR RANGES. HOT PLATES. OVENS. FOOD WARMERS. GRILLS, DRVERS. <P\C HEATERS. LEADS FOR HEAT GENERATING APPARATUS. ETC. MAXIMUM OPERATING TEMPERATURES: HI-TEMP--200CC. (392-F.) MOISTEMP--125;C. (25"=F 3 21 1. SOLID OR STRANDED COPPER. NICICIL 08 mONEI CONDUCTOR 2- FELTED ASBESTOS IMPREGNATED WITH EITHER "HI.TEMP'' OR "MOISTEMP" COMPOUNDS 3. ASBESTOS SRAIO. "HI-TEMP" OR "MOISTEMP" IMPREGNATED 3 21 "HI-TEMP" Insulation--Heat and Flame resisting--Use for High Temperatures, little or no moisture. "MOISTEMP" Insulation--Heat, Flame and Moisture resisting--Use for Heat and Moisture conditions. HOW and WHERE TO SPECIFY EITHER "HI-TEMP" or "MOISTEMP" INSULATIONS These Underwriters' approved stove wires are furnished in two basic types of impregnations: "HI-TEMP" Impregnation in both the felted will and braid is heat and flame resisting and designed for applications where the temperature is usually high with little or no moisture. Under heat, and because of high wattage and close confinement, moisture accumulated during the "off" period is dissipated before a leakage path or short can develop. This condition exists in many products, but care must be exercised in determining whether the temperature rise is sufficiently rapid to dry out the insulation, as a slowly rising tempera ture will permit leakage to build up to a point where a short may occur. "MOISTEMP" impregnation in both the felted wall and braid is designed for applications where the temperature is high but not extreme, and where humidity and moisture may cause current leakage. For example, in some appliances and devices the insulation at the ends of the wires attached to heating units is exposed to high temperatures while the rest of the wire run may be in a moist, lower temperature area. For these applications specify "Moistemp" impregna tion as it is not only heat and flame resistant but moisture resisting as well. CURRENT-CARRYING CAPACITIES are listed on page 7 foe these wires along with Current Correction Factors for various ambient temperatures. SPECIAL CONDUCTORS such as CopperweM or alloys other than nickel or monel or extra flexible conductors can be supplied oft special order. NOTE: Tables A and R are rated 300 volts in this catalog since stove wire is limited to a 300-volt rating, however these tables are shown in our 10-G catalog with a 600-volt rating for industrial usage. Solid Moistemp: Solid Hi-Temp: Table A -- Copper Table A-300 -- Copper Table AM -- Monel Table AM-300 -- Monel : Nominal Thickness -- Mils ( *Nominal j Approx. 1 Bare Finished I Net Wgt. Diam. . Felted Asbestos i Diameter ! in Lbs. - Size | Inches Wail ' Braid 1 Inches ] per 1000' ; **18 AWG .040 30 : 40 .180 i 18 **l 6 ,0H i w i 40 , .195 22 1 14 , .064 ' 30 i -*0 : .205 i 28 : 12 ' .081 30 ! 40 ! .225 } 38 ; 10 .102 : 30 1 40 ' .245 ! 52 i 8 ' .128 . 30 i 40 | .270 | 69 Table AN -- Nickel Table AN-300 -- Nickel +Standard Approx. Shipping Shipping Length Weight Fee: ' per tOOO- 500'C 500'C 500'C 500'C 500'C 500'C : | ?> 28 33 43 57 79 Coarse Stranded Moistemp: Coarse Stranded Hi-Temp: Table R -- Copper Table R-300 -- Copper Table RM -- Monel Table RM-300 -- Monel Table RN -- Nickel Table RN-300 -- Nickel Nominal Thickness -- Mils Bare Diam. Felted Asbestos Size Stranding Inches Wall Btaid Nominal Approx. Finished Net Wgt. Diameter in Lbs. Inches ; per 1000' ^Standard Shipping Length Feet Approx. Shipping Weight per 1000' Moistemp Hi-Temp Moistemp Hi-Temp IMoistempI Hi-Temp Moistemp Hi-Temp ** 18 AWGj7/.Ol52 ,04<S 30 30 40 .190 .190 21 18 500'C 27 24 **16 7/.0192 .058 30 30 40 .200 .200 27 23 500'C 32 28 14 7/0.242 .073 30 30 40 .215 .215 33 29 500'C 38 35 12 7/.0305 .092 40 30 40 .255 .235 47 44 500'C 52 45 10 7/.0385 .116 40 30 40 .280 .260 63 54 500'C 69 60 8 7/.0486 .146 40 30 40 .310 .290 89 72 500'C 94 83 Finished diameter given above is average. A tolerance of plus or minus Not listed by Underwriters' laboratories tC--Coils. is necessary due to variations in process of manufacture. ROCKBESTOS PRODUCTS CORPORATION 14 RBB 00550 1000 VOLT (Underwriters' Approved) APPLIANCE LEAD WIRE FOR THE INTERNAL WIRING OF APPLIANCES SUCH AS FLUORESCENT FIX TURES. MAXIMUM OPERATING TEMPERATURE 90C (194*F.) U. L. APPROVED TOGO VOLT APPLIANCE LEAD WIRE l. $OUO O* STSANOEB PUkJN COPES* CONDUCTORS 3 2. SYNTHETIC TAPE 21 3. IMPREGNATED FEITED *S#ESTOS This Underwriters' Approved 1000 volt Appliance lead wire is available with either solid or stranded plain copper con ductors insulated with high dielectric tape and impregnated felted asbestos. These wires were designed tor the internal wiring of light ing appliances and fixtures which called foe a 1000 volt wire to operate dependably in high temperatures. This wire is especially recommended for use in connection with cold cathode lighting fixtures where starting voltages exceed 300 volts. These wires are furnished in black, white, and red as stand ard colors. TABLE FE Size . A.W.G. , Stranding 18 Solid 16 Solid 14 Solid 1000 VOLTS Bare Diam. Inches j Nominal Thickness--Inches i : Synthetic ! Tape Felted Asbestos ; i Nominal Diam. Inches* | Approx. . Net Wgt. ' In Lbs. ; Per 1000' .040 ! .051 .064 .0065 .0115 .0115 .031 : .115 11 .026 .130 : 14 .026 i .140 ; 20 U.L APPROVED Standard Shipping Length Feet : Approx. , Shipping j Weight | Per 1000' 1000 C 1000 C 1000 c 13 17 24 Stranded 18 16/30 .045 | .0065 16 26/30 .059 ; .0115 14 41/30 .075 j .0115 .031 i .120 ; u .026 .135 ; 15 .026 .150 ! 21 i 1000 C : 1000 C ' 1000 C | Finished diameter given above is avenge. A tolerance of plus or minus is necessary due to variations in process of manufacture. 13 IS 25 NEW HAVEN, CONNECTICUT 15 RBB 00551 U. L APPROVED TOGO VOLT APPLIANCE LEAD WIRE 1000 VOLT ASBESTOS and GLASS (Underwriters' Approved) APPLIANCE LEAD WIRE < FOR L'SE IN' RADIO EQUIPMENT. AMPLIFIERS AND THE INTERNAL WIRING OF ELECTRONIC EQCIPMENT. MAXIMUM OPERATING TEMPERATURE 90CC. (194CF.) 1. SOLID 0* STRANDED TINNED COPPER CONDUCTOR 2- SYNTHETIC TAPE 3. IMPREGNATED PELTED AS8ESTOS t. LACQUERED GLASS SRaiD This Underwriters' Approved 1000 volt Appliance wire is available with either solid or stranded tinned copper con ductors. It is insulated with helically applied synthetic tapes and impregnated felted asbestos and covered overall with a glass braid lacquered to a hard smooth finish. Here is an easy stripping, high dielectric wice resistant to dame, heat and moisture, grease and oil. With its 1000 volt rating it is recommended for use in Radio Equipment, Amplifiers and for the internal wiring of Electronic Equipment. Standard finish tor this wire is white lacquered glass braid. This wire can be color coded by the use of colored tracers in the glass braid. TABLE FG 1000 VOLTS Size A.W.G. Stranding ' Bare Diam. Inches ; Nominal Thickness--Inches 1 Svnthetic ' Felted Braid ! Tape . Asbestos Thickness na Solid : .025 .010 .0085 .005 20 Solid .032 ; .010 .0085 .005 IS Solid .040 j .010 .0085 .005 16 Solid .051 ; .oio .0085 .0075 14 Solid i .064 ! .010 .0085 .0075 12 Solid .081 j .010 .0085 .0075 Nominal Finished Diam. Inches .080 .085 .095 .110 .120 .145 Approx. Net Wgt. In Lbs. Per 1000' 5 6 9 12 18 28 U L. APPROVED Standard Shipping Length Feet Approx. Shipping Weight Per 1000' 1000 c iooo c 1000 c 1000 c iooo c 1000 c 6 7 10 14 21 34 Stranded 22 7/30 : .030 20 10/30 ; .038 IS 16/30 i .045 16 ! 2b 30 ; .059 14 j 41.30 ; .075 12 65/50 . -095 .010 j .0085 .010 | .0085 .010 j .0085 .010 j .0085 .010 j .0085 .oio j .0085 .005 j .085 1 > : iooo c ! .005 j .090 | .005 I .100 ! 6 ! 1000 C : 9 i iooo C i .0075 ! .120 | 12 ! iooo c 1 .0075 ; .130 ! is i iooo c i .0075 : 155 i 29 1 iooo C : Finished diameter given above is average. A tolerance of plus or minus is necessary due to variations in process of manufacture. 6 7 ll 15 22 36 ROCKBESTOS PRODUCTS CORPORATION 16 RBB 00552 DISTRICT SALES OFFICES t MAIN OFFICE and FACTOR N i col I and Conner Sts. NSW HAVEN 4. CONN. NEW YORK 17. N. Y. Room -1.516. Chrysler 3ldg. -05 Lexington Ave. CLEVELAND 21, OHIO 2000 War.-ensville Center Road OETROIT 21. MICH. 3330 West McNicnofs Road ST. LOUIS 21, MO. .amber?--St. Louis Municipal Airport SEATTLE 3, WASHINGTON 401 5 Aurora Ave. ATLANTA S, GA. 3127 Maple Drive Room 20-1 "CHICAGO 24, ILL. -534 West Madison St. DALLAS 5. TEXAS 1655 N. Central Expressway PITTSBURGH 19, PA. 2520 Kopoers 3ldg. "BURLINGAME, CALIF. 6 Guitrard Road LOS ANGELES S, CAL. 4020 w. Third Sr. "Warehouses: Chicago, III. -- Surtingame, California Manufactured in Canada by Phillips Electrical Co. ilPS31 ltd.. 26 Hollingor Road. Toronto 13. Ontario. Canada. Manufactured in Australia by Cablet Makars Australia Ply. Ltd.. Liverpool, N.S.W.. Australia. ROCKBESTOS PRODUCTS CORPORATION NEW HAVEN 4, CONNECTICUT s J RBS 00554 300 VOLT ASBESTOS and GLASS APPLIANCE LEAD WIRE FOR RANGES, ROASTERS, WATER and SPACE HEATERS. INFRA-RED OVENS, LEADS FOR HEAT GENERATING APPARATUS, ETC. . MAXIMUM OPERATING TEMPERATURE 200CC. (392F.) 1. NICKEl CONDUCTOR fSOLJO OR STRANDED) wiaiif fft' ' 34 2. SYNTHETIC TAFE 3. FEITEO ASBESTOS a. ClASS BRAID, SUICONE COATED This ideal high temperature insulation of high dielectric tapes combined with felted asbestos impregnated with "HiTemp." heat and flame resistant compound and covered overall with a silicone coated glass yarn braid. Standard conductors for these Asbestos and Glass insulated appliance lead wires are solid and stranded nickel (or a maximum operating temperature of 200!C. These appliance lead wires are used tor high temperature applications where the temperature at terminal connections is too high to allow the use of copper conductors. They were originally designed as leads in electric range deep well cooker units where high temperatures in confined areas along with the flexing action of raising and lowering the unit called for a wire to withstand the heat and remain permanently flexible. Standard color: Natural (Tan) only. TABLE AG 300 VOLT (Asbestos-Glass Covered) Size A.W.G. Stranding Nominal Thickness-Mils Bate Diameter Dielectric Felted Braid Inches Insert Wall Thickness Nominal Finished Diam. Inches Approx. Net Wgt. In Lbs. Per 1000' 12 Solid .081 14 Solid .064 16 Solid .051 2.5 30.5 7.5 2.5 30.5 7.5 2.5 30.5 7.5 .165 .150 ..35 33-9 24.8 18.4 Standard Package--Ft. Non-Returnable Lg. Metal ! Wooden Coils Spools Reels 1000 i 1000 1000 \ 1500 2500 3500 . 8500 : 10,000 j 10,000 Approx. Shipping Weight Per 1000' 40 29 22 12 65/.010 14 41 '.010 16 26'.010 .095 .075 .059 Stranded 2.5 30.5 7.5 2.5 30.5 ! 7-5 2.5 30.5 7.5 .180 .160 .145 36.1 26.0 19.4 1000 | 1000 j 1000 j 1500 2500 4000 | j 7500 2500 4000 43 31 23 > RBB 00553