Document ype4kpoQ7EQZQkQDb71rGapwr

Air System Equipment jdGrm Air Diffusers CONNOR ENGINEERING CORP. . Danbury, Conn. Representatives in o-draft A11 Principal Cities adjustable air diffusers In Canada: Douglas Engineering Co.. Ltd., Montreal, P. Q. CONTROLLED AIR DIFFUSION Kno-Draft Adjustable Air Diffusers are designed to give accurate control of air distribution, plus installation and oper ation economies. With air direction and air volume adjustments on each diffuser, "custom-made" air patterns can be created which will insure draftless dif fusion and equalized temperatures for comfort conditioning or specific patterns for industrial processes__ Type KDA for supply air. Type SRD for combination Installation, balancing and inspection A.l,uminum, sires 4 to 36 i.n. sSuizpepsl6y toa8n4din.rseutuprpnly naeicrk. are fast because of features like the Type neck dm. Capacities SO to Capacities SO to S.SOO cfm per unit, return neck HD quick-opening set-lock assembly, the self-contained inner unit and the sleeve- J5fi00 cfm per uni/. area 75% of supply. type damper. System design problems are eased because Kno-Draft Diffusers are adjustable after installation. The often difficult and hazardous job of figuring everything about the air movement in advance is eliminated. And the air pattern in an area can be changed with the seasons or when processes, people or partitions are relocated. Kno-Draft Diffusers are geometrically proportional, size for size, insuring like re sistance at like neck velocity for any size--a considerable advantage when selecting various size diffusers for a common system. Designed for high or low ceilings or attachments to exposed ducts, these diffusers will effectively distribute large volumes of air and pre-mix room and supply air. They permit the use of high duct velocities-- resulting in smaller ducts and lower costs. Duct designs are simplified. The simple, attractive design of the Kno- Draft Diffusers enables them to blend with either period or modern interiors In their original aluminum, they'create an interesting and unobtrusive decora Diffuser and Cone separated Diffuser and Cane tive accent. Painted to match the ceiling, they become Self-effacing. assembled Anti-Smudge Cone: Where exceptionally sooty or dusty air conditions are expected or where rough-textured ceilings are employed, the use of this accessory cone is recommended. It furnishes the additional control needed to provide' the precise I- air separation which inhibits smudging. wim com set LOW. AS PLOWS HOOZONTAI1T A* COM I S fcUSSb OOWMttUD.. Kno-DraftDiffueersareaneredby U,8.Patents No.8,S6S,887;8J869,119; iASiJtSS and other* pending; Canadian Patents floe. 489J06; 448#6. ^ Any angle of air discharge needed to suit ceiling heights and heating, ventilating or cooling air patterns can be obtained by ramny or toisenny bottom Con* B. 1316 Connor Engineering Corp. -_ Registers Air System Equipment TypeD Air Volume Control operates independently of the air directional adjustment. It varies only the quantity, not the characteristic of the air distribution. It consists of a cylindrical, sliding, sleeve-type damper connected by a specially designed spider Fig. I Self-Contained Inner Unit Fig. 8 Type HD Set-Lock Assembly to a centrally operated screw. The shank of the screw extends through the lower cone of the diffuser and is concealed by a tamper-proof cap. With this damper on each unit, a series of diffusers can be quickly balanced. Kno-Draft Features Speed Installation The development of the self-contained, removable inner assembly alone (see Fig. 1) reduced installation time as much as 50 per cent. The addition of the Type HD set- lock assembly (see Fig. 2) reduced the time for that part of the installation to a matter of minutes. No tools are required. The B cone or inner element of the diffuser is secured to the combined suspension and adjustment screws by a springloaded catch Fig. S Now Standard Equipment Fig. i Air Direction Adjustment Fig. S Balancing Fig. 6 Air Volume Adjustment which is kept in compression by a slotted washer. The holes in B cone pass over the bolt heads. All that is necessary is to press up on B cone and insert or remove the slotted washers. (See Fig. 3.) Even where ceilings already exist, the outer cone is easily attached to a duct or collar. The air direction adjustment is also accomplished quickly. All that is needed is a screwdriver to adjust the suspension screws for any angle of air discharge from hori zontal to vertical. (See Fig. 4.) System balancing is fast-and simple. The single annular air stream permits im mediate and accurate veiometer reading. (See Fig. 5.) Desired air supply ratios may be rapidly obtained by adjusting the volume control dampers. A twist of the wrist regulates the volume instantly. (See Fig. 6.) Nation-wide Sales and Engineering Service Connor Engineering Corp. maintains a research laboratory with a staff of trained specialists and district represen tatives in leading cities. Their services are at the disposal of consulting engineers, architects, air conditioning dealers and plant engineers. They can assist you in getting the best possible performance from your air conditioning system by creating custom-made air patterns which will thoroughly mix room and supply air, eliminate drafts and maintain uni form temperature throughout an area. Free Handbook on Air Diffusion It contains the latest engineering data on air diffusion and is profusely illustrated with charts, photographs, sketches and dimension prints that simplify the selection, application, location, assembly, erection, testing and adjusting of Kno-Draft Adjust able Air Diffusers.' It is designed to help you get top efficiency from an air con ditioning system by creating "custom-made" air distribution patterns. For your FREE copy, please write Dept. Y-29. (See pages 1888 and 1889 for data on Dorex Air Recovery and Air Purification Equipment.) 1317