ujii 'Oti ? m DATE: SUBJECT: DATE OF SAMPLES: SUMMARY: SAMPLE TIME START STOP Z-8969 Z-8970 9:50 9:52 12:52 12:52 DISCUSSION: RECOMMENDATIONS: METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO: INDUSTRIAL HYGIENE RESULTS June 30, 1987 Monitor UCC Design and Construction insulators for exposure to asbestos during removal using a glove bag. In Polymers I tank farm in area outside, behind 8" mill. 2/13/87 PLAINTIFF'S EXHIBIT UC-3068 TOTAL (Min.) FLOW RATE VOLUME TYPE RESULTS PEL 182 3900 cc/min 709.8 1 B2 180 4000 cc/min 720 1 BZ 0.22 f/cc 0.09 f/cc 0.2 f/cc 0.2 f/cc During the three hour sample period one of the insulators (sample #2-8969) exceeded the TWAg permissible exposure limit of 0.2 fibers per cubic centimeter of air. Protective clothing and Comfo II half-face respirators with HEPA filters were worn. The respirators were more than adequate to protect against these fiber concentrations. Wet methods were used. The area in which the work was being performed was a small, cramped corner with little room for free movement. This may have contributed to the above results. Use caution when removing asbestos using the glove bag method. Wet methods of removal must be stringently enforced even when used in glove bags. Continue wearing respiratory protection when using the glove bag method. Continue 1H monitoring. Inform insulators of the results of these tests. Microscopy C. R. McMillan/T. L. Grittie JHM Labs ''D. A. Boggs, J. E. Boley, E. L. Doerflein, T. K. loannou, K. B. Purinton, L. P. Smith, S. M. Walker, G. W. Wulfert. UCC 002060