Document ypVnwRG1G26rM9YLKk5pdd8JE

PLAINTIFF'S EXHIBIT Certairileed H AC Pressure Pipe& Fluid-Tite Couplings engineerhg drawings 8c CTD032862 CG Fluid-Tite Pipe Nom. Size Pipe & Class 6"-100 8"-100 10"-100 12"-100 14M-100 16"-100 18"-100 20"-100 24"-100 6"-150 8"-150 10"-150 12"-150 14"-150 16"-150 18"-150 20"-150 24"-150 6"-200 8"-200 10"-200 12"-200 14"-200 16"-200 Nom. I.D. Inches 6.00 8.00 10.00 12.00 13.60 15.50 18.00 20.00 24.00 5.80 7.80 10.00 12.00 14.00 16.Q0 18.00 20.00 24.00 5.70 7.60 9.60 11.44 13.60 15.50 B.O.D. Inches 7.16 9.32 11.46 13.70 15.36 17.50 20.30 22.50 27.00 7.12 9.32 11.85 14.11 16.41 18.65 21.20 23.54 28.22 7.36 9.46 11.88 14.11 16.44 18.74 O.D.t Inches 6.91 9.11 11.24 13.44 15.07 17.15 19.90 22.12 26.48 6.91 9.11 11.66 13.92 16.22 18.46 20.94 23.28 27.96 6.91 9.11 11.66 13.92 16.22 18.46 O.Dj Inches 7.07 9.27 11.40 13.60 15.23 17.31 20.06 22.28 26.64 7.07 9.27 11.82 14.08 16.38 18.62 21.10 23.44 28.12 7.07 9.27 11.82 14.08 16.38 18.62 C Inches 2.40 2.40 2.40 2.90 3.25 3.25 3.75 3.75 3.75 2.40 2.40 2.40 2.90 3.25 3.25 3.75 3.75 3.75 2.40 2.40 2.40 2.90 3.25 3.25 P Inches' .75 .75 .75 1.00 1.00 1.00 1.00 1.00 1.00 .75 .75 .75 1.00 1.00 1.00 1.00 1.00 1.00 .75 .75 .75 1.00 1.00 1.00 a 16 16 16 16 18 18 20 20 20 16 16 16 16 18 18 20 20 20 16 16 16 16 18 18 All Dimensions Subject to Manufacturing Tolerances To batter service your requirements, please contact your local CartainTeed Territory Manager, Sales Agent or CartainTeed Sales Representative tor availability. CTD032863 CG Fluid-Tite Coupling o oo oo Nom. Size & Class 6"-100 8"-100 12"-100 16"-100 18"-100 20"-100 24"-100 6"-150 8"-150 10"-150 12"-150 14"-150 16"-150 18"-150 20"-150 24"-150 6"-200 8"-200 10"-200 12"-200 14"-200 16"-200 A Inches 7.65 9.85 11.98 14.18 15.95 18.03 20.78 23.00 27.36 7.65 9.85 12.40 14.66 17.10 19.34 21.82 24.16 28.84 7.65 9.85 12.40 14.66 17.10 19.34 Bt Inches 7.20 9.40 11.53 13.73 15.39 17.47 20.22 22.44 26.80 7.20 9.40 11.95 14.21 16.54 18.78 21.26 23.60 28.28 7.20 9.40 11.95 14.21 16.54 18.78 Bi Inches 7.03 9.23 11.36 13.56 15.20 17.28 20.03 22.25 26.61 7.03 9.23 11.78 14.04 16.35 18.59 21.07 23.41 28.09 7.03 9.23 11.78 14.04 16.35 18.59 B.O.D. Inches 8.40 10.80 13.30 15.55 17.60 19.80 22.60 25.30 30.00 8.76 11.32 14.36 17.00 19.80 22.28 24.91 27.55 33.02 9.35 12.00 15.15 17.90 20.50 23.20 M Inches 3.50 3.50 3.50 4.50 5.20 5.20 6.20 6.20 6.20 3.50 3.50 3.50 4.50 5.20 5.20 6.20 6.20 6.20 3.50 3.50 3.50 4.50 5.20 5.20 L Inches 7.00 7.00 7.00 8.00 9.00 9.00 10.00 10.00 10.00 7.00 7.00 7.00 8.00 9.00 9.00 10.00 10.00 10.00 7.00 7.00 7.00 8.00 9.00 9.00 F Inches .76 .76 .76 .76 .83 .83 .83 .83 .83 .76 .76 .76 .76 .83 .83 .83 .83 .83 .76 .76 .76 .76 .83 .83 G Inches .92 .92 .92 .92 1.00 1.00 1.00 1.00 1.00 .92 .92 .92 .92 1.00 1.00 1.00 1.00 1.00 .92 .92 .92 .92 1.00 1.00 J Inches .42 .42 .42 .42 .42 .42 .42 .42 .42 .42 .42 .42 .42 .42 .42 .42 .42 .42 .42 .42 .42 .42 .42 .42 Ji Inches .18 .18 .18 .18 .25 .25 .25 .25 .25 .18 .18 .18 .18 .25 .25 .25 .25 .25 18 .18 .18 .18 .25 .25 All Dimension* Sub|ect to Manufacturing Tolerances To batter Mrvtc* your requirement*. pteSM contact your local CartalnTaed Tarrttory Manager, Sato* Agent or CertalnTeed Sato* Representative for availability. CTD032864 Fluid-Tite Pipe End with Certa-Spacer Band Nom. Size Pipe & Class 4"-100 4"-150 4"-200 Nom. I.D. Inches 4.00 4.00 4.00 B.O.D. Inches 5.05 5.14 5.32 O.D.i Inches 4.64 4.81 4.81 O.Dj Inches 4.80 4.97 4.97 C Inches 2.90 2.90 2.90 P Inches .75 .75 .75 a 16 16 16 Fluid-Tite Coupling oo 1 Nom. Size Pipe & Class 4"-150 4"-200 A Inches 5.57 5.74 5.74 B Inches 4.76 4.93 4.93 B.O.D. Inches 6.25 6.66 6.88 H Inches 4.88 4.88 4.88 L Inches 6.50 6.50 6.50 F Inches .81 .81 .81 G Inches .70 .70 .70 R Inches .13 .13 .13 J Inches .38 .38 .38 OC Inches .18 .18 .18 All Dimensions Subject to Manufacturing Tolerances CTD032865 To better service your requirements, please contact your local CertalnTeed Territory Manager, Sales Agent or CertalnTeed Sales Representative for availability. , .Q O e 3o oo 23 "o- s Oo PAD 5* Direct* D ire c t D ire c t D ire c t D ire c t PAD 5 D ire c t PAD 5 D ire c t PAD 5 D ire c t PAD 5 D ire c t PAD 5 D ire c t PAD 5 D ire c t PAD 5 D ire c t kJ lr.wO_r J2C> cQ>o> cO<O<o0s. DODCO i|o Eo o> o^ a o 2"- o (3 ba) Q Qa oo aa Ou a5 lO a a-o<. o ao. a ak c<l toat) am_ ~< a cl o" a ~ a < cl o ai_n - < aa in a .b < aa 1,-o a) j2o m>cQoto. O) ! S O q5 DOCEO HS a ^3 CM as <a u- ss LL LL CM CO aa << CL CL CM CO aa << CL CL CM CO aa <cl <a. CM CO aa << CL q_ CM CO aa << CL CL CM CO aa << CL CL CM CO ao << CL CL CM CO aa < cl a<. CO o isO CM as < uCL ss Li. LL CM CO aa << Q. CL CM CO aa << CL CL CM CO aa << CL CL CM CO aa << CL CL CM CO aa <a. < ol CM CO aa << CL CL CM CO aa << CL CL CM CO aa << CL CL . All connections marked with an asterisk ( ') are with CERTA-SPACER--All others are Common Groove (CG). Where "N o" is indicated, Class 150 pipe should not be used in Class 100 fittings. How To C onnect CertainTeed Fluid-Tite Pipe To Other Pipe, Fittings and Valves Q *D * "3 2S Qo. o CM as < uCL ss LL LL CM CO aa << a. a. CM CO aa a<. < cl CM CO aa c<l <a. CM CO aa << CL CL CM CO aa << CL OL CM CO aa << a. cl CM CO aa << CL CL CM CO aa << CL CL OL. Ok. OW o0h). o o o o0) *o- *o- o o o o o o o a o a a a a a a a a aa aa a a aa aa a a ag (35 8 | D .h o 9o Pa 2*9 Ow O0w) OL_ Ok. va. ak_ T- O ^ T- O ^ O O o a O O O O O O u2. tS a a a a aa 2: aa aa aa aa aa O ,,ca gs o C3 lQ O LL O ^o CO CM 00 o <-1 w O O ^oo CO CM 00 O -<J iTno O o CO CM 00 <m -J 1- O O ^oo CO CM CO o < in _J r- o O CO CM -<J tinO O CO CM <-J oiTno O C^O o CM co O <-1 in O OO co o coif? <-1 o 1Oo-- co S CO ! <-I o Oo co 2 coJ2 <-J o * <D o a o o o oa oo o o (5 O 0 O a o CO CO o CM V<T" b 00 o CM CM CTD032866 t- CM Pipe Adaptors When ordering adaptors state specifically what the adaptor is going from and to. Example: PAD 3 from CLASS 15010" A/C Fluid-Tite Pipe to 10" Mechanical Joint C.l. ----------------------------------- Ll l2--------------1 PAD 2 CLASS 100 FLUID-TITE CG TO CAST IRON MECHANICAL JOINT AND/OR POURED BELL END PAD 2 SIZE INCHES NOMINAL I.D. INCHES Li INCHES INCHES O.D.i INCHES O.Dj INCHES 4 3.73 15 8 4.64 4.81 8 7.45 15 8 9.11 9.05 10 8.94 15 8 11.24 11.10 12 10.98 15 8 13.44 13.20 14 13.17 19.5 11.5 15.07 15.30 16 15.16 19.5 11.5 17.15 17.40 18 17.34 19.5 11.5 19.90 19.50 20 19.02 19.5 11.5 22.12 21.60 24 22.98 19.5 11.5 26.48 25.80 Note: For 6" connections use appropriate Fully-Machined Pipe. An Internal Bevel has been specially provided where required for butterfly valve clearance. All Dimensions Subject to Manufacturing Tolerances PAD 3 SIZE INCHES NOMINAL I.D. INCHES Li INCHES L2 INCHES O.D.i INCHES O.D.2 INCHES 8 7.45 15 8 9.11 9.05 10 8.94 15 8 11.66 11.10 12 10.98 15 8 13.92 13.20 14 13.17 19.5 11.5 16.22 15.30 16 15.16 19.5 11.5 18.46 17.40 18 16.81 19.5 11.5 20.94 19.50 20 18.15 19.5 11.5 23.28 21.60 24 21.82 19.5 11.5 27.96 25.80 For Class 200 Adaptors 8" through 16" only. Note: For 4" and 6" Connections use appropriate Fully-Machined Pipe. An Internal Bevel has been specially provided where required for butterfly valve clearance. All Dimensions Subject to Manufacturing Tolerances CTD032867 L, ID PAD 5* CLASS 100 FLUID-TITE CG 1o CLASS 150/200 FLUID-TITE CG PAD 5 SIZE INCHES NOMINAL I.D. INCHES Li INCHES Li INCHES O.D.i INCHES O.D.I INCHES 4 3.80 15 8 4.64 4.81 10 9.56 15 8 11.24 11.66 12 11.44 15 8 13.44 13.92 14 13.30 19.5 11.5 15.07 16.22 16 15.16 19.5 11.5 17.15 18.46 18 17.34 19.5 11.5 19.90 20.94 20 19.63 19.5 11.5 22.12 23.28 24 23.37 19.5 11.5 26.48 27.96 For Class 200 Adaptors 4" and 10" through 16" only. Note: For 6" and'8" Connections use Class 200 Fully-Machined Pipe. All Dimensions Sub|ect to Manufacturing Tolerances Pressure Pipe Coupling Adaptor 0 CLASSES 100, ISO, 200 COUPLING SIZE INCHES A. INCHES B. INCHES C. INCHES Gs INCHES 4 5.52 4.56 4.63 0.70 6 7.31 6.69 6.77 0.63 8 9.40 8.69 8.78 0.63 10 11.55 10.81 10.91 0.63 12 13.55 12.81 12.92 0.63 Other Dimensions: For other dimensions not shown, refer to standard coupling dimension. Note: For excessively oval steel pipe, field reworking of the B s to the C s dimension is permitted. Special rings are supplied for the Steel/PVC end. All Dimensions Sub|ect to Manufacturing Tolerances CL 100 INCHES 6.25 8.40 10.80 13.30 15.55 B.O.D. CL 150 INCHES 6.66 8.76 11.32 14.36 17.00 CL 200 INCHES 6.88 9.35 12.00 15.15 17.90 CTD032868 Pressure Pipe Coupling Reducer Fluid-Tite Pipe to Fluid-Tite Pipe COUPLING REDUCER SIZE INCHES I.D. INCHES B.O.D. INCHES L INCHES X INCHES Class 100 6 to 4 8 to 6 10 to 8 12 to 10 14 to 12 16 to 14 18 to 16 20 to 18 24 to 20 4.56 6.60 8.69 11.01 13.19 14.85 16.81 19.60 21.81 7.16 9.32 11.46 13.70 15.55 17.60 20.30 22.60 27.00 6.50 6.50 6.50 7.00 7.75 8.00 9.00 10.00 10.00 3.50 3.50 3.50 3.50 4.00 4.50 4.50 5.00 5.00 Class 150 6 to 4 8 to 6 10 to 8 12 to 10 14 to 12 16 to 14 18 to 16 20 to 18 24 to 20 4.68 6.60 8.69 11.47 13.77 16.00 18.00 20.00 23.00 7.16 9.32 11.85 14.36 17.00 19.80 22.28 24.91 28.22 6.50 6.50 6.50 7.00 7.75 9.50 10.00 10.50 10.00 3.50 3.50 3.50 3.50 4.00 4.50 4.50 5.00 5.00 Class 200 6 to 4 8 to 6 10 to 8 12 to 10 14 to 12 16 to 14 4.68 6.60 8.69 11.47 13.60 15.50 7.16 9.36 12.00 15.15 17.90 20.50 6.50 6.50 6.50 8.25 9.00 9.50 3.50 3.50 3.50 3.50 4.00 4.50 Other Dimensions: For other dimensions not shown refer to standard Pipe and Coupling dimensions. All Dimensions Subject to Manufacturing Tolerances CTD032869 District Offices Atlanta Pipe District 2295 Parklake Dr., N.E. Suite 510 Atlanta, GA 30345 404/938-4616 TWX: 810-766-4926 Denver Pipe District 5115 South Valley Highway Suite 156 Englewood, CO 80111 303/773-2760 TWX: 910-935-0888 Houston Pipe District Suite 670 P.O. Box 25185 Houston, TX 77005 713/960-1470 TWX: 910-881-1652 Los Angeles Pipe District 1801 East Parkcourt Place Suite 103 Santa Ana, CA 92705 714/972-2644 From Los Angeles: 213/625-1915 TWX: 910-591-1661 Phoenix Branch Office 2255 West Northern Suite 8110 Phoenix. AZ 85021 602/864-1177 TWX: 910-951-1462 Philadelphia Pipe District 987 Old Eagle School Road Suite 703 Wayne, PA 19087 215/687-9250 TWX: 510-668-0641 St. Louis Pipe District 301 Sovereign Court Suite 111, Regency Park Manchester, MO 63011 314/394-7330 TWX: 910-760-1850 San Francisco Pipe District 3000 Citrus Circle Suite 210 Walnut Creek, CA 94598 415/938-6800 TWX: 910-385-6815 Export P.O. Box 860 Valley Forge, PA 19482 215/687-5000 TWX: 510-668-1912 TELEX: 845-263 CertainTeed El Pipe & Plastics Group P.O. Box 860 Valley Forge, Pa. 19482 Code No. 40-21-01 H-fiev CTD032870 Printed mUSA 0690