Document ypQw1ZpmLQjXDN6EY9x86g1KX
arm i *\
BENDIX
Cl 15 PERSONNEL MONITOR
the only air sampler with .. . AUTOMATIC VOLTAGE REGULATION Gives absolutely constant reading of =2% Guarantees 8 hours of midget impinger sampling
2.8 LPM AP 12" H0 Guarantees 14 hours of gravimetric sampling at
2 LPM AP4"H'0 Eliminates flow rate adjustments during sampling
period.
FLOAT PULSATION ELIMINATOR Ends float bounce for precise reading
BUILT-IN BATTERY VOLTAGE TESTER Allows instant check of battery condition
1
Z.B
--1---- 1-- 1
1
,
1 ! i j 1
RSV 0005607
BENDIX
C-115 PERSONNEL AIR SAMPLER
Guaranteed to collect 99% of the sample . . exceeding the rigid requirements of and approved by the Bureau of Mines for Intrinsically Safe Operation in Explosive Atmospheres. Bendix superiority is demonstrated in the Clio PERSONNEL MONITOR. LIGHTWEIGHT. COMPACT and VERSATILE ... the Cl 1 5 is an air sampler offering advanced features found >n no other Instrument in the field and mav be used with midget impingers. micro impingers. membrane filters or respir able mass samplers. Powered by a 7.5 volt, 2 amp-hour rechargeable nickel cadmium battery, the Cl 15 is supplied complete with a 110 volt/60 cycle battery charger. A precision diaphragm pump and hi-torque low current dram motor insures high efficiency monitoring.
Here's why the Cl 16 can give you 99% sampling accuracy
FEATURES
AUTOMATIC VOLTAGE REGULATOR Gives absolutely constant reading of :t2%. Guarantees 8 hours of midget impinger sampling at 2.8 LPM AP 12" HsO Guarantees 12 hours of gravimetric sampling at 2 LPM A P 4" HjO Eliminates flow rate adjustments during sampling period
FLOAT PULSATION ELIMINATOR Ends float bounce for precise reading
BUILT-IN BATTERY VOLTAGE TESTER Allows instant check.of battery condition
LEAD-IN-AIR ANALYSES Simple 3-step procedure provides accurate analysis using Bendix Inorganic Lead-inAir Reagents.
TDI-MDI DETERMINATIONS Will provide threshold limit values from 0 01 to 0.08 PPM using Bendix reagents and color standards.
C-115 PUMP PROVIDES THE NECESSARY VACUUM FOR PRACTICALLY ANY PORTABLE GAS ANALYSIS TEST
The C-115 is designed for the collection of toxic and combustible gases, vapors, dusts, fumes, and mists which are then evaluated by various analytical techniques. Numerous Bendix portable gas detection instruments and Colorimetric Detector Tubes can be used with the Sampler The device, therefore, can be used to collect samples of explosive gases, oxygen, ammonia, carbon dioxide, carbon monoxide, chlorine, hydrogen chloride, hydrogen sulfide, mercury vapor nitrogen dioxide, sulfur dioxide, toluene dusoeyanate. lead dust and fumes, and chromic acid mist. Dust counts can also be made, using Midget Impingers in conjunction with a microscopic analysis. Particulate sampling can be performed for radioactive dust and beryllium dust. A desired sample flow is obtained by setting the flow adjust screw to an indexed position on the flow meter. Our standard instrument comes factory calibrated at 2 8 LPM and 2.0 LPM. Special air flow calibrations are available on request. The C-11 5 is equipped with a tube fitting on the outlet or exhaust side of the pump, it can be used in positive pressure applications.
RSV 0005608
IMPINGER SAMPLING
The C-11 5 Air Sampler is designed for use with Bendix Calibrated Midget impmgers and Bubblers in sampling dust, gases, and vapors. !t is the only Personnel Air Sampler on the market that guarantees 8 hours of continuous sampling at 2 8 LPM A P 12" HjO.
Threshold Limit Value Determinations from 0.01 to 0.08 PPM using Bendix TDI-MDI Reagents and Color Standards {Toluene Di isocyanate/MethyleneBis (4 Phenylisocyanate) are accomplished with the use of the midget impinger.
RESPIRABLE MASS LAPEL SAMPLER
The Lapel Sampler, when used with the Bendix Cl 1 5 Pump, simulates the collection characteristics of the human lung. As air is sampled, the cyclonic action of the unit separates the coarser particles of dust {those which would deposit in the upper respiratory passage) from the finer, more harmful particles which penetrate into the lung. The larger par ticles fali to the bottom of the tube, the finer particles are drawn to the filter assembly in the capsule, where they are trapped on a filter mem brane for subsequent analysis, either weighing or counting. Approved by the Bureau of Mines for Intrinsically Safe Operation in Explo sive Atmospheres and the Environmental Health Service Bureau of Occu pational Safety and Health.
RESPIRABLE DUST SAMPLER Filter Paper Holder adapts the Cl 1 5 *or personnel monitoring or sampling for the detection of lead dust, radioactive particulate, beryllium ana other hazardous particulates.
ANALYZER FOR INORGANIC LEAD FUMES* Simple 3-step procedure provides accurate analysis exceeding the requirements of the "Occupational Safety and Health Act of 1970." Using Bendix Inorganic Lead-in-Air Reagents and Color Standards, measures accurately within a range from 0 02 mg. /mJ to 0.4 mg./mJ of inorganic lead. This field method for atmospheric sampling orovides immediate and accurate determinations of serrvquantitative lead concentration in air throughout an entire workday. In contrast to the chemical method that could take 8 hours or more, the field method for analyzing the same number of samples reauires less than 10 minutes with the Cl 1 5.
ANALYZER FOR TDI AND MDI* * The Cl 1 5. when used with calibrated midget impinger. will provide Threshold Limit Va'ue De terminations from 0.01 to 0.08 PPM using Bendix TDI-MDI Reagents and Color Standards (Toluene Diisocyanate/Methylene-Bis (4 Phenyl isocyanate}.
RSV 0005609
Cl 15 ATTACHE UNIT 3600-18
For tota1 convenience the Cl 1 5. battery charger and all accessories fit compactly into this handsome attache styie carrying case. Case provides excellent protection for unit, while portfolio m cover is ideal for valuable reports, test papers, instruction litera ture and suggestions for care of unit.
Description
Part Number
C-i15AirSampierw 'Battery and Charger 3650-10
C-11 5 Air Sampler Only
3650-05
N-cad Battery 7 5V
3600-31
Battery Charger 110V 60Hz
3600-20
Standard Calibrated Midget impmger
7202
Impmger Holder
3600-35
Sampling Head Ass'y w/Cyclone.
Hose and Clip
3900-90
Sampling Cassette/Capsule Assembly 3900-906
Filter Holder 25 mm Pkg. of 6
1107
Filter Holder and 37 mm Membrane
3600-309
Filter (0.8 Micron Size) for Asbestos
Dust Sampling.
Description
Part Number
*37 mm 3-Part Plastic Filter Holder.
*37 mm Membrane Filter (0.8 Micron Size).
3600-300 3600-301
Filter Paper 25 mm Pkg. of 100
60692
2 ft. Rubber Tubing 3/16 ID Code 40/20 Inorganic Lead-In-Air
2110-32
Reagents with Color Standards for Lead
Dust in air evaluation (50 evaluations
2250-10
TDI/MDI Color Standards TDI/MDI Reagents
2200-30 2200-20
Attach* Case w/Ethafoam Insert
3600-18
Part Nos 3600-309.3600-300 and 3600-301 Filter Holder and F.lte Media (0.8 Micron Size) complies with Federal Register Regulations 191093a for Asoestos Oust Sampling.
Ref "Ref
Enriaue A. Quino -- Field Method for the Dotorminotlon of Inorganic Load Fumoo in Air -- The Journal of the American Industrial Hvgiene Association -- Vol 20. No. 2 (April 1959). Printed in U.S.A. Marcali. Kalman -- Mkrodotornilwotlon of ToluenodUoocyenef in Auwoophere -- Anal. Chem: 29. 552 (April 1957).
K E. Grim and A. L. Lincfi -- Recent leocyonat)n-Alr Analyst* Studio* -- AIHA: Vol. 25 (May-June 1964).
NATIONAL ENVIRONMENTAL INSTRUMENTS, INC
W. O. 8o 690, Mlgrlm Station. Warwick, ft. I. 02999
Toi. {401) 738*3710
CaMa NElCO TWX 710 397-1694
Distributed by:
A Zink SAFETY EQUIPMENT
w OF MISSOURI, WC
10312 BACH OUUVAftD ST LOUIS. MISSOURI 6)132 iuiaui sia anaitltA
RSV 0005610