Document yp8Z8ggNnEJBp8OQZN53BpRQ6

Insulation Duct Owens-Corning Fiberglas Corporation .General Offices--Toledo 1, Ohio. Pacific Coast Division. P.O. Box 89, Santa Clara. Cal. r I BERGLAS A COMPLETE LINE OF INDUSTRIAL INSULATIONS Fiberglas Duct Insulations Fiberglas Duct Insulations come in both rigid and flexible forms in six basic types. All deliver top insulating performance against heat and cold plus the additional advantage of sound control. Fiberglas Vapor-Seal Duct Insulation is ideal for use on air conditioning ducts in warm and humid areas. Built-in vapor barrier of asphalt and kraft paper. Full range of thicknesses for specific tempera tures. Fiberglas Flexible Duct Liner is used as a sound absorber and thermal insula tion inside ducts.. Available in two thicknesses with high NRC. Fiberglas Flexible Duct Insulation can be used to provide thermal insulation on exterior of ducts of any shape. Faced Flexible' Duct Insulation, with facings of foils, duplex papers and rein forced laminate for vapor barrier or appearance purposes. Fiberglas Coated Duct Insulation is a versatile product used for both inside and outside duct insulation. Fiberglas PF Duct Insulation for cover ing rectangular ducts at minimum cost for efficient performance. Fiberglas* Pipe and Block Insulation Fiberglas PF (pre-formed) Pipe Insulation available in all standard sizes for both low temperature and heated piping. Dual-Temperature Pipe Insulation for use on cold piping or dual-temperature piping. Fiberglas Block Insulation and PF Insulating Boards for small and large heated or cooled equipment. Aerowrap* Pipe Insulation for heated piping, cooled piping, steam traced lines, valves and fittings. Blanket-Type Pipe Insulation for hot pipes up to 1000F, welded pipe and large pipe sizes. Low Pressure Pipe Insulation for hot water and low pres sure steam lines and for cold water pipe. Fiberglas PF Insulation, a general-purpose insulation for heated or cooled equipment. Fiberglas TW-F Insulating Wool, general-purpose insulation used for high-temperature equipment and industrial ovens. Metal Mesh Blankets for breechings, tanks, ovens, and other high-temperature equipment for temperatures to 1000F. Kaylo Pipe and Block Insulation The low coefficient of conductivity, or "k," of Kaylo Heat Insulation, together with its long life at temperatures up to 1200F makes it ideal for high temperature insulation. Avail able in all standard sizes. Easily cut or fitted on the job. Made of hydrous calcium silicate by Owens-Illinois Glass Co. and distributed by Owens-Corning Fiberglas Corp. For detailed information on Fiberglas Insolations look in the yellow pages for your local Fiberglas Distri butor-Contractor or write Dept 44, Owens-Coming Fiberglas Corporation, Toledo 1, Ohio. FIBERGLAS (Reg. U.S. Pat. Off.) and AEROWRAP are trade-marks of Owens-Corning Fiberglas Cor poration. 1642 Insulation Glass Blocks Owens-Illinois GENERAL OFFICES- TOLEDO 1, OHIO GLASS BLOCK AND TOPLITE PANELS TWO (l) PRODUCTS Owens-Illinois Glass Block are hollow, hermetically sealed glass units contain ing a % vacuum. They are laid in mortar to form light-transmitting panels in vertical walls. Owens-Illinois Glass Block provide quality-controlled day lighting by glass areas which reduce heat loss, surface condensation and in filtration in cold weather and heat gain in warm weather. Thermal Insulation The coefficients of heat transmission "U" for panels of Owens-Illinois Glass Block are as follows: Size of Block "TF* (Bto/sq Ft/Hr/F Temp Difference 5*4" Sq 7*4" Sq 7*4" Sq 11*4" Sq 11*4" Sq with Glass Fiber Insert with Glass Fiber Insert .60 .56 .48 .52 .44 Surface Condensation Because of the low over-all, air-to-air heat transfer, the exterior air tempera tures which will produce condensation on panels of Owens-Illinois Glass Block are much lower than that for ordinary single glass. This permits higher humid ities to be maintained where needed for winter air conditioning for comfort or for industrial processes. Infiltration Panels of glass block which are laid in mortar provide a barrier against infiltra tion. Dusts, drafts, and air vapor leak age are minimized. Natural ventilation requirements can be met by installing windows in glass block panels. Solar Heat Gain Complete instantaneous solar heat gain data for Owens-Illinois Glass Block de signs for all exposures are given on Pages 296 and 297 of THE GUIDE. The design numbers which correspond with the ASHVE type numbers are, as fol lows : ASHVE type Mo. I II III IVA V O-I Block Design Mos. 307, 316, 330, 331, 370 340 340 With Fiberglas Insert 365 363 A new Owens-Illinois Block design, No. 80-F, is now available which has a much lower maximum solar heat gain than any of those shown in THE GUIDE. This reduction is due to the fact that this block reflects a high percentage of the solar energy which is incident on the exterior at the time of year when it reaches a maximum. Calculations of the solar heat gain through this block are now available. Confirming tests are being run. Write for data. Owens-Illinois Toplite Panels Owens-Illinois Toplite Panels are made of hollow, partially evacuated and hermetically sealed glass units, pre fabricated at the factory into panels of insulated aluminum grid construction. Used horizontally in roofs, Toplite Panels offer controlled daylighting with reduced heat loss and surface condensa tion. Solar heat gain through Toplite panels is much less than that through single glass skylights, due to the fact that Toplite Panels reflect a high per centage of the solar energy when the sun is at high altitude angles as in the spring and summer months. Design and Sizes Owens-Illinois Glass Block are made in a variety of face designs and in three standard sizes (5^ in. Sq, 7% in. Sq, and Xl% in. Sq, all 3% in. thick). Mortar joints of in. thickness are recom mended. Prefabricated Toplite Panels are available in four standard sizes (3 ft x 3 ft, 4 ft x 4 ft, 3 ft x 6 ft, and 4 ft x 5 ft). All are 3He inches thick. Complete technical data, description and details will be gladly sent. Write: Kimble Glass Company, subsidiary of Owens-Illinois, Department HV, P, O. Box 1035, Toledo 1, Ohio.