Document ymqqz1d2DJNkrq4zoY213nNKE

E. Kailar RfcD Laboratories - 1700 so. 2nd - St. Louis March 7. 1968 ' Orville Hicks - Res. 2 THERMINOL/SANTOTHERM Contamination of Cooking Oil - Smith Potato Crisps, Holland________________________ ' Ronald E. Roush - DROUS We have made an attempt to measure SANTOTHERM FR-1 at the . 100 parts per million level In peanut oil used for cooking potato crisps at subject company In Holland. Total Chlorine analysis by sodium biphenyl reduction shows 180 parts per million chlorine In both new and used peanut oil. Preliminary oscillographic polarograph measurements Indicate that there Is less than 20 parts pe^r million Thermlnol FR-1 (Aroclor 1242) In the used peanut dll sample from Holland, Currently, the polarograph Is In need of repair. More sensitive measurements will be attempted when our instrument Is back In Bervice. It is expected that this should be within several weeks, REKtdb R. E. Keller o or MQNS 097448