Document ymgRYdXo1qX47emaNOavYxb9X
bcc: Fay Baj j - Log Angeles
April 29, 1968
flic....! <!_
restr'.y: l
:'VX " '
. ;C " i`
..
Mr. Dave Frit* Kaiser Aluminum Trantwood Works Spokane, Washington
Dear Mr. Frit*:
Our Los Angeles Office has asked ms to forward toxicity and safe handling information on our firs resistant hydraulic fluid, l>ydraui 312
I have enclosed a copy of our bulletin entitled 'Toxicity and Safe Handling of Pydraul 312." In addition, I thought you might be interested in the more detailed data discussed below.
The oral toxicity of this product shows an ldjo to rats of 6500 mg/kg and it is classified as 'practically non-toxic* from the acute oral point of view.
When applied to the skin undilutad and allowed to remain over night, a barely perceptible redness occurred, giving a maximum score of 1.3/8.0, which was classed as a slight irritant. The material proved capable of being absorbed through the skin in high doses when allowed to remain on the rabbit under a cuff. The minimum lethal dose wss somewhere over 2000 and under 3000 mg/kg. This would fall into the 'slightly toxic* range.
The material is a slight eye irritant whan applied undiluted to the rabbits' ayes and there was mild discomfort and slight redness The maximum score was 13/110 and the eye had returned to normal within three days.
Rats survived six-hour inhalation exposure to the vapors evolved at ambient temperatures following the passage of sir through the material. No systemic effects were noted.
Clinically, we have had no cases of illness occurring in our employees during the manufacture and distribution of this material nor have we had reports of injuries from the field.
MQNS 09Q953
Mr. Dave Fritz
-2- Aprll 29, 1968
ilowevor, there is no question but that a potential of injury could occur should the fumes evolved at elevated temperatures be breathed for long periods of time or repeatedly. Likewise, tho action of the material on the skin causes defatting but, oven more so, repeated or continuous skin contact must be avoided to prevent absorption of the material with systemic affects. I repsat, however, these conditions have not coma to my attention.
If you have any further questions, please writs directly to
Sincerely,
REX/ln enc.
R. Emmet Kelly, M. D. Medical Director
MONS 090959