Document ymaJjnx0p1qkowdBN6ELmqpv4

paper Communicated to the HUE Conference at Lancaster JULY, 1970 Dielectric Loss and Resistivity Results presented at the TCB Conference on "Dielectric Materials, Measurements and Applications" (20 - 24 July, 1970) appear to suggest that it may be possible to avoid time effects due to the measuring stress in measurements of dielectric loss and resistivity of trichlorodiphenyl. Mr. Krasucki will summarise the results and open a discussion on the implication of the results to standard isation of procedures to be adopted in measurements of tanG and resistivity of askarels. \ STLCOPCB4075177 ) DIELTDTRIC LOSS OF T HICHLORODIPHENYL AT EIEVATED TEMPERATURES Z. Krasucki Introduction Recent investigations of electrical properties of trichlorodiphenyl-impregnated polypropylene film capacitors 1 necessitated making extensive studies of the effect of poly propylene on the dielectric loss of trichlorodiphenyl. These studies were made using trichlorodiphenyl which, after purification with activated Fullers' earth, filtration and degassing, was heated in contact with polypropylene film at 95C fbr 6A hours. Measuranents of tan 6 of -the trichlorodiphenyl extracts, made in an MPL cell at $0Can& at 1 kV (r.m.s.)/mm using a Scheiing hridge, showed that tan 6 varied from 0.005 (value obtained with the highly purified trichlorodiphenyl blank sample) to 0.5 depending on the quality of the film. It was found that, t over the whole range of values considered, tan 6 tended to change with time in the course of a single measuranent (1-2 minutes). As these changes were considered to be a potential source of uncertainty in measurements of dielectric loss of trichlorodiphenyl, it was considered necessary to study them systematically. Measuranents of Dielectric Los3 Initial measurements cf tan 6 of a trichlorodiphenyl extract of polypropylene were made (NPL cell, 90C at 1 kV (r.m.s.)/mm and at 50 Hz. With the stress applied continuously to the liquid, it3 tan 6 was found to decrease continuously with time under stress. The results cf these ' measurements are presented in Fig. 1, curve a. Removing the stress and resting the sample at 90C for about 16 hours resulted f- in an almost complete recovery of tan 6. On reapplicatiaa of the stress, tan 6 again decreased continuously mth time (see Fig. 1, curve b). Repetition of the process cf stressing followed by a s rest period, t, the latter varying from l6 to 136 hours, gave results presented in curves c, d, e and f of Fig. 1. These . results show -that changes in tan 6 of trichlorodiphenyl with time under stress are reversible. The changes of tan 6 with time presented in Tig. 1 were brought about by the application of the measuring stress to the liquid. It was of interest, therefbre, to determine the effect of changing the magnitude of the applied electric stress on the dependence of-tan 6 on time. Measurements were nade cf tan 6 s of the trichlorodiphenyl sample (after its recovery from the (: earlier measurements) as a function of time at 50 V(r,m.s^/mm and at 500 V (r.m.s.)/mm. The results are presented in Tig. 2 where, for comparison, curve f of Fig. 1 is also plotted. It mil be seen from Fig. 2 that there was no change mth time of tan 6 measured at 50 V (r.m.s.)/mm and that the tan 6-time dependence at 500 Y (rjn.s.)/W was smaller than that at 1 kV (rjn.s.)/mm. These results indicate "that the magnitude of the tan 6-time li dependence increases mth increasing stress applied to the liquid. i The tan6-time dependences discussed so far could have been caused by changes in the resistivity of the liquid. The contribution to tan 6 from the resistance of the liquid hould be inversely proportional to the measuring frequency and measurements of dielectric loss of the sample usel, made at frequencies between 50 Hz and 1000 Hz (lew stresses), showed that the plot of tan 6 against l/frequency was a straight line. The resistance of the liquid calculated from the slope of the Mr. Z. Krasucki is a Group Leader in the Materials Sciences Division of the Electrical Research Assocdaticn. DSW 323531 STLCOPCB4075178 i -2 - Q straight line was 7.9 x 10 ohm and that measured with a Vibron electrometer was 8 x 10 ohm when extrapolated to zero time. This agreement between the measured resistance and that derived from tan 6 measurements suggests that dielectric loss in the trichlorodiphenyl sample used was predominantly due to the presence of free charge carriers !I in the liquid. A Tan 6 of the trichlorodiphenyl sample used fbr I obtaining the results presented in curve f of Fig. 1 was measured at frequencies between 200 Hz and 1000 Hz and also at 50 Hz (50 V (r.m.s. )/mm) both before and after application of the 1 kV (r.m.s.)/mm stress. The results of these measurements are presented in Pig. 3. It will be seen from the figure that the plots of tan 6 against l/frequency were ! straight lines and that the polar contribution to loss, given by the intercept on the ordinate, was 0.0004-. Assunirg that carrier mobilities do not change as a result of stressing at 1 kV (r.m.s. )/nm, the results of Pig. 3 indicate that the concentration of free charge carriers decreases with time under stress-.-- . In order to determine whether the direct proportionality between tan 6 and l/frequency in trichlorodiphenyl is true at temperatures below 90C ard for different contamination levels f in the liquid, some of the results obtained during studies of i! compatibility between triohloridjhaiyl and polypropylene film s were plotted on graphs of tan 6 against l/frequency. Pig. 4- gives the dependences cf tan 6 of trichlorodiphenyl (contaminated to different degrees) on l/frequency at room temperature and at 60C. It will be seen from the figure that the dielectric loss I! of any given sample of trichlorodiphenyl was always inversely proportional to the frequency. These results suggest that dielectric I0S3 of trichinrediphenvl at room temperature aid above i3 determined bv the presence of free charge carriers Jt TSTthe liquid. t Discussion The results presented show that dielectric loss in trichlorodiphenyl at elevated temperatures is due to the presence of free charge carriers in the liquid and that assuming a constar mobility, the carrier concentration in the liquid decreases with time when the field applied is riOQ V (r.m.s.)/mm or higher. A possible explanation tbr the decrease is that carriers are swept away by cordon ting particle impurities present in the liquid. At the stress of 1 kV (r.m.s.)/mm those condurting particles ii which acquire charge by coining into contact with the electrodes will move through Hie liquid with velocities much higher than those of free charge carriers and will thus be cble to collect carriers along their paths. As on reversal of polarity the conducting particle will move back towards the eLectrode, where it becomes recharged, the nett effect in the course of time is expected to be the trapping cf more and more carriers on the particle. As the particle velocity will decrease more rapidly S than linearly with decreasing applied electric field, such a carrier trapping process is expected to be less efficient the lower the applied field. DSW 323532 - It is felt that the results presented in this paper have a bearing on considerations of procedure to be adopted in measurements of dielectric I03S and resistivity of liquids like trichlorodiphenyl. Measurements of tanftof trichlorodiphenyl at 1 kV (r.m.s. )/mm are STLCOPCB4075179 -3 - likely to be subject to uncertainty because of tie presence of time effects but the magnitude of the effects decreases with decreasing stress and they appear to be absent at stresses of 50 V (r.m.s.)/mm or less. It follows therefore that, in order to avoid uncertainties due to time effects present when dielectric loss is measured at hi$i stress, viz. stresses of 500 V (r.m.s.)/mm or more, measurement s tan 6 ^ of trichlorodiphenyl drould be.made at a low stress. If f the available bridge is not sufficiently sensitive for making low-stress tan 6 measurements at 50 Hz, then it is permissible to obtain the 50 Hz value of dielectric loss-by extrapolation from a straight line plot of tan 6 against l/fr equency, where - ' / the frequency ranges from 200 Hz to 1000 Hz. The intercept of this straight line on the ordinate gives the dipolar r contribution to the dielectric loss and the slope cf -the line gives the short-time resistivity of ihe liquid. il Conclusions Dielectric loss of trichlorodiphenyl measured at 90C exhibits variations with time rhich are caused by the application of measuring stress to the liquid and result from changes in the concentration of free carriers in the liquid. The liquid recovers its initial value of dielectric loss if the measurirg stress is kept off fbr 16 hours. ~" Changes in dielectric loss of trichlorodiphenyl with time decrease in magnitude as the measuring stress is lowered and they appear to be absent at 50 V (r.m.s.)/mm. Values of dielectric loss of trichlorodiphenyl measured at frequencies between 200 Hz and 1000 Hz lie bn a straight line Then plotted against l/fr equency. Extrapolati cn to 50 Hz gives directly the 50 V (r.m.s.)/mm dielectric loss and the slope of the straight line gives the short-time resistivity of the liquid. It is recomnended that, in order to avoid uncertainties due to the presence of time effects in the measurement of dielectric loss at high stress (500 V (r.m.s.)/mm and higher) and also s in the measurement of resistivity, both the dielectric loss and the short-time resistivity of liquids like tri chi orodiph myl be derived from measurements of tan 6 made at low stresses ard at frequencies between 200 Hz and 1000 Hz. Reference 1. Z. Krasucki ard H.F. Church, ERA Report No. 5260, 1969. f ). I STLCOPCB4075180 : ' ; 4 . <i V .! ' ' . .V < ( i i ! \ t ; t DSW 323534 STLCOPCB4075181