Document ymZQR4Q3Kmkq703Jx6y7kXB94
A. I. A. File No. 3 1 -C -6 7 2 also N o. 31-C-679
------------------------------- ---------------------------------
This is the Rockbestos Handbook and Catalog No. 10-E which illustrates and describes wires, cables and flexible cords designed for use where electric wiring, either in conduit or open, is exposed to heat, fire hazard, corrosive fumes, vapors, oil or grease.
' All data subject to change without notice.
ROCKBESTOS PRODUCTS CORPORATION Main Office and Works
NEW HAVEN 4, CONNECTICUT, U. S. A.
District Offices listed on back page
---------------------------------------------------------------------------------------
A. I. A. File No. J l c-672 also No. Jl-c-679
Catalog No. 10-E
March 1, 1939
RBB 00309
*
t I
world's largest factory derated exclusirtly to the manufacture of permanently insulated wiret, cables and cords.
MAIN OFFICE AND WORKS
ROCKBESTOS PRODUCTS CORPORATION
NEW HAVEN 4, CONNECTICUT, U. S. A.
"Rockbestos" is the name of a wide line of wires, cables and cords designed to operate with out failure under severe conditions.
In designing the insulation for wires which will be exposed to heat, corrosive fumes, smoke, oil, grease or fire hazard we have found asbestos to be the broad common denominator because this unique material not only remains unchanged under heat and is, therefore, absolutely fireproof but in addition, is inert and therefore unaffected by age.
But asbestos is only one ingredient of Rockbestos insulation. Other insulating materials such, for example, as varnished cambric, glass and synthetic resins contribute to the overall performance of a number of Rockbestos wires. Then there is the selection of impregnating compounds -- an entire field by itself. Rockbestos has developed its own time-tested impregnating compounds and finishes with heat, flame and moistureproof characteristics but chemical research in many laboratories is producing dozens of new materials and all these are being tested without prejudice that we may utilize the best characteristics of many materials and produce wire that operates without failure within constantly enlarging limits.
Two lines -- A.V.C. and Ail-Asbestos -- have been standardized and constitute the bulk of the wires shown in this handbook but the explosion-proof AC secondary network cable and the moisture resisting and fireproof non-Ieaded vault cable are examples of the special group of Rockbestos wires where asbestos and other insulating materials or special compounds have been combined to produce a wire which will meet certain rigid specifications.
RBB 00310
INDEX BY TABLE LETTER
Table
Page
A AC ACS
Rheostat Wire, 600 Volt All-Asbestos..................................................... 48 ' Rheostat and Stove Wire, 300 Volt Solid All-Asbestos............................. 47
Rheostat and Stove Wire, 300 Volt Stranded All-Asbestos...................- 47
B
Switchboard Wire, 600 Volt A.V.C.................................................
38
BH Switchboard Hinge Cable, 600 Volt A.V.C................................................ 40
BS *-Switchboard Cable, 600 Volt, A.V.C....................................................... 39
C CA CAC CV CVC
Boiler Room Wire, 600 Volt A.V.C........................-............................... Duplex Flexible Cord, All-Asbestos.......................................................... Triplex Flexible Cord, All-Asbestos.......................................................... Duplex Flexible Cord, A.V.C Type............................ Triplex Flexible Cord, A.V.C Type..........................................................
25 55 55 56 56
E Power Cable, 600 Volt A.V.C..................................................................... 26 EC Power Cable, 600 Volt A.V.C., multi-conductor....................................... 27 EL Power Cable, 600 Volt A.V.C, lead sheathed.................. -..................... 28 EM Power Cable, 1000 Volt A.V.C............................................................... 29
F
Power Cable, 2000 Volt A.V.C........................................................
30
FA Twisted Pair Heat Resisting Flexible Cord.......... ..................................... 54
FC Triplex Heat Resisting Flexible Cord.....................
54
FR Duplex Heat Resisting Flexible Cord....................................................... 54
FR Duplex Heat Resisting Flexible Cord, lacquered.........*......................... 54
FS Fixture Wire, heat resisting.......................................................................... 53
G Power Cable, 3000 Volt A.V.C..................................................................... 31
H Power Cable, 5000 Volt A.V.C................................................................. 32 HD Heater Cord, heavy duty industrial type.................................................. 57
L Motor Lead and Apparatus Cable, 600 Volt A.V.C................................... 33
LH
Heating Cable, lead sheathed industrial type................................
64
MD-MT ML
Multi-conductor Control Cable........... ..................................................... 36-37 Mining able, 600 Volt A.V.C.................................................................. 34
P Switchboard Bus able, 600 Volt A.V.C.................................................... 41
R Rheostat and Power able, All-Asbestos................................................... 50
RF Apparatus Cable, All-Asbestos flexible .......................
51
S
Signal Wire.....................................................................................
58-59
T Headlight Wire............................................................................................ 59 TC Thermostat Control Wire........................................................................... 61
UL Secondary Network Cable............................. ............................. ............... 62 UV Fireproof Vault able................................................................................. 63
VK Elevator Control able............................................................................... 35
VT
Elevator Lighting able.....................................................................
35
W Apparatus able, All-Asbestos extra flexible.......................................... 52
XB
XBH XBS
Switchboard Wire, 600 Volt, Type SNA................................................... 44
Switchboard Hinge able, 600 Volt, TypeSNA...................................... 46 Switchboard able, 600 Volt, Type SNA................................................. 45
YC-YV YS-YA
Pyrometer Wire, A.V.C. Type........................................................... .'....... 60 Pyrometer Wire, All-Asbestos.................................................................... 60
RBB 00311
INDEX BY NAME
Table
Apparatus Cable, AU-Asbestos flexible............ ................................. RF......... -- Apparatus Cable, All-Asbestos extra flexible....................................W............. Apparatus Cable, A.V.C Type........................................................... L............... Armored Cable........................................................................................................ Asbestos, nature of.................................................................................................. Boiler Room Wire, 600 Volt A.V.C...................................................C.......... -- Cab Cord, All-Asbestos Duplex................. -..................................... CA ....... .. Cab Cord, All-Asbestos Triplex.........-..............................................CAC........ Cab Cord, A.V.C Type Duplex......................................................... CV .......... Cab Cord, A.VC Type Triplex.........................................................CVC........ Characteristics of Rockbestos Wire........................................................................ Conduit Size Tables................................................................................................ Control Cable, Multi-conductor.............................................. .......... MD-MT .. Control Wire, armored....................................................................... TC ........... Control Wire, single conductor........................................................ C................ District Offices........................................................................................................... Elevator Control Cable........................................................................VK .......... Elevator Lighting Cable......................................................................VT .......... Extension Cord.................................................................. ..................CV .......... Fixture Wires, heat resisting............................................................... FS............. Flexible Cords, heat resisting.............................................................FA-FC-FR Flexible Cord, All-Asbestos Duplex................................................ CA ........... Flexible Cord, AU-Asbestos Triplex.................................................. CAC......... Flexible Cord, A.V.C. Type Duplex................................................ CV ........... Flexible Cord, A.V.C Type Triplex...................................................CVC........ Headlight Wire......................................................,..............................T............... Heater Gird, heavy duty industrial type............. ...............................HD........... Heating Cable, lead sheathed industrial type................................... LH ........... Hinge Cable, flexible switchboard type............... :........................... BH ..........
Index, by Table Letter--by Name................................. ...................................
Jumper Cable, AU-Asbestos flexible.............................. ....................RF.......
Lead Sheath......................................................................................... ................
Lighting Wire.......................................................................................C.........
Mining Cable, 600 Volt A.V.C......................................................... ML .....
Motor Lead and Apparatus Cable....................................................... L.........
Power Cable, 600 Volt AU-Asbestos............... .................................R.........
Power Cable, 600 Volt A.V.C............................................................. E..........
Power Cable, 600 Volt A.V.C. lead sheathed................................... EL........
Power Cable, 600 Volt A.V.C. multi-conductor...............................EC.......
Power Cable, 1000 Volt A.V.C............................................................EM.....
Power Cable, 2000 Volt A.V.C............................................................F.........
Power Cable, 3000 Volt A.V.C........................................................... G..........
Power Cable, 5000 Volt A.V.C............................................................H .......
Pyrometer Wire, All-Asbestos...........................................................YS-YA
Pyrometer Wire, A.V.C. Type........................................................... YC-YV
Rheostat and Power Cable, stranded conductor................................. R.........
Rheostat and Stove Wire, 300 Volt Solid All-Asbestos.................. AC .....
Rheostat and Stove Wire, 300 Volt Stranded All-Asbestos........... ACS ...
Rheostat Wire, solid conductor ......................................................... A.........
Secondary Network Cable ..............................................
.........UL .....
Signal Wire, 606 Volt A.V.C..............................................................S..........
Specifications for Rockbestos Wires.................................................................
Switchboard Bus Cable, asbestos braided.......................................... E.........
Switchboard Bus Cable, cotton braided...............................................P.........
Switchboard Cable, cotton braided, stranded conductor.................. BS.......
Switchboard Cable, Type SNA...........................................................XBS ...
Switchboard Hinge Cable, cotton braided, flexible........................... BH .....
Switchboard Hinge Cable, Type SNA................................................ XBH ...
Switchboard Wire, asbestos braided.................................................. C..........
Switchboard Wire, cotton braided.....................................................B .........
Switchboard Wire, Type SNA...........................................................XB .....
Thermostat Control Wire................................................................... TC .....
Uses for Rockbestos Wires................................................................................
Vault Cable, Fireproof........................................................................UV .....
Page .. 51 .. 52 .. 33 .. 15 .. 6 .. 25 .. 55 .. 55 .. 56 .. 56 12-13 21-24 36-37 .. 61 .. 25 .. 65 .. 35 .. 35 .. 56 .. 53 .. 54 .. 55 .. 55 .. 56 .. 56 .. 59 .. 57 .. 64 .. 40 14-20
4-5 .. 51 .. 15 .. 25 .. 34 .. 33 .. 50 .. 26 .. 28 .. 27 .. 29 .. 30 . 31 .. 32 .. 60 .. 60 . 50 .. 47 .. 47 .. 48 .. 62 58-59 15-20 .. 26
41
.. 39 .. 45 .. 40 .. 46
- 25 .. 38 .. 44 .. 61
7-11 .. 63
RBB 00312
ASBESTOS . . older than the Centuries
There's real romance in drawing on the Earth for the asbestos insulation of Rockbestos wires, cables and cords.. That unique, non-metallic mineral--a natural formation in the earth--is practic ally as old as Earth itself, formed at the time when glowing clouds hung low over the new planet, when warm, seething, steamy seas, mud oceans and molten lava ebbed and flowed over the restless surface of our globe during the turmoil of creation . . . when Earth's crust was slowly cooling, hardening; when mountains were being upthrust by subterraneous upheavals and when terrific pressures were combining water, silica and magnesia into rock-like strata which later came to be known as ... Asbestos.
This is what science believes to be the explanation for the wide occurrence of asbestos over the Earth's surface. At any rate, all agree that Asbestos is millions of years old in its present form -- that it has not changed in the memory of Man and that its present form is probably the form it first took back in the dawn of Earth's birth.
Hard as a rock in the vein, asbestos is soft as silk when fiberized. Each silky fiber is a crystal 1/500,000th of an inch in diameter.
A million-year-old handful! This asbestos has been completely fiberized and prepared and is now ready to be carded into roving.
Asbestos is found on every continent--generally in commercial quantities. Asbestos deposits vary greatly, however, and not all of it, by any means, is suitable for use as electrical insulation of wires.
Some of these deposits are relatively pure, i. e., free from iron content, while others have a high iron content so that the asbestos from these latter, unless cleaned in some way in an attempt to remove the iron particles and other impurities, is useful only for such mechanical asbestos products as shingles, fireproof board and so on.
For years we have investigated the world sources of asbestos to find and secure the softest, silkiest, purest, long fibred asbestos--and we find it in certain deposits of Chrysotile (Serpentine Group)--the aristocrat of the asbestos family.
This asbestos is mined, broken up, fiberized, subjected to special refining processes and then combed and carded into soft, fluffy roving. In this foam it is applied to the conductor, impregnated with neutral insulating compounds, and compressed into the felted wall which is Rockbestos insula tion -- a protective covering that is not only fireproof but practically impervious to the destruction normally caused by heat, oil, grease, corrosive fumes or age. What a material to use where endur ance and resistance to deterioration are important!
RBB 00313
7
USES
for
ROCKBESTOS WIRES
RHEOSTAT WIRING
For connections between grids and from grids to faceplates use Table A and R rheostat wire and cable, pages 48 and 50. These All-Asbestos insulated wires will not deteriorate under constant high temperatures. The very nature of the All-Asbestos insulation prevents its ever growing hard and brittle and cracking as happens with rubber insulation, for example, under heat. Its initial mechanical and electrical characteristics are permanently retained.
LIGHTING AND CONTROL CIRCUITS IN CONDUIT
Use A.V.C. Boiler Room Wire, Table C, page 25, for solid conductor. For stranded conductor use A.V.C. Power Cable, Table E, page 26, or A.V.C. Control Cable page 36. 11 experience shows severe condensation allowing water pockets, to form and continue for long periods, use Lead Sheathed A.V.C. Power Cable, Table EL, page 28. This wire will stand up under conditions ranging from complete and continuous submersion to high and dry temperatures.
POWER CIRCUITS UP TO 5000 VOLT SERVICE
Many times important circuits are located where severe conditions pre vail. Rockbestos A.V.C. Power Cable is designed to stand up without failure under conditions of heat and moisture, corrosive fumes, oil, grease or fite hazard. Fot applications where cable may be submerged in water specify lead sheathing. 600 Voit A.V.C. Power Cable, Table , is described on page 26. For service voltages above 600 use Table EM, F, G or H cable shown on pages 29, 30, 31 and 32.
CONDUIT WIRING AROUND FURNACES, OVENS, SOAKING PITS, LEHRS, TENTER FRAMES, ETC.
Use Rockbestos A.V.C. Boiler Room Wire, Table C, or Rockbestos A.V.C. Power Cable, Table E, pages 25 and 26. For service voltages above 600, use Rockbestos A.V.C. Power Cable, Tables EM, F, G or H shown on pages 29, 30, 31 and 32.
RBB 00314
ROCKBESTOS
SUBWAY CAR
AND LOCOMOTIVE WIRING
The combination of heat and vibration to which the wiring of subway cars, electrified railway locomotives, electric mine locomotives and steam locomotives is almost constantly subjected, is ruinous to ordinary wire insulation. Rockbestos A.V.C. Motor Lead and Ap paratus Cable, and A.V.C Mining Cable, designed to meet builders' requirements for heatproof and fireproof cable for railway and mine locomotives, finds several applications in electric cars and locomotives for shoe leads, trolley leads, transformer and motor leads. It remains permanently flexible due to the non-deteriorat ing characteristics of the insulation and its flame, heat and moisture resisting qualities are equally permanent. See pages 33 and 34. Rockbestos Flexible Cord and Heaalight Wire is used by many railroads for cab light ing and gauge lighting as well as for circuits to head lights and classification lights. See pages 53, 36 and 59-
MOTOR LEADS, WINDINGS AND COIL CONNECTIONS
Rockbestos A.V.C Motor Lead and Apparatus Cable -- heat resisting, fireproof and permanently flexible -- is ideal for leads and coil connections. It is widely used by steel mills, on electrified rail roads and on elevated and subway railways. An important point is that it remains permanently flexible because its in sulation does not grow hard or brittle with heat or age. See page 33
Another important point is that A.V.C Cable cannot burn. When A.V.C Cable comes in contact with a hot fire there is a small amount of black smoke given off for a minute or so and after that the cable simply glows red hot. There are no dense clouds of smoke at any time -- no choking fumes -- because A.V.C. insulation simply will not burn. The hazard of burning insulation is thereby completely eliminated when a locomotive or car is wired with Rock bestos A.V.C. Motor Lead and Apparatus Cable.
We have made special studies of motor lead applications on rolling stock from the point of view of determining the maximum flexibility of conductor. As a result of this experience we are in a position to help railroad and railway engineers write a specification for a motor lead cable which will have the maximum flexibility and at the same time possess fireproof and moisture resisting qualities.
Windings: The use of heat resisting magnet wire, replacing cotton, is on the increase. While it is somewhat higher in price than the more usual types, it is actually less expensive to use if severe operating conditions burn out windings made of ordinary wire. A motor wound with Rockbestos Magnet Wire and equipped with Rockbestos A.V.C. Cable for leads and coil connections, is just about as failureproof, electrically, as a motor can possibly be. Magnet wire is an item of such im portance that we publish a separate bulletin on it.
SWITCHBOARDS AND PANEL BOARDS
Rockbestos originated and patented the first switchboard wire with the A.V.C. insulation. This is a genuinely fireproof wire but besides that wiremen like it because it does not crack when sharp bends are fmde when wiring boards. That is because the felted asbestos wall on top of the varnished cambric (see cut, page 38) acts as a cushion, instead of being stiff and unyielding; result, a smooth, square bend.
For jumper connections to hinged panels use Rockbestos Hinge Cable, page 40, which is similar in appearance, si2e and electrical characteristics to the Table B Switchboard Wire. Like Rockbestos Hinge Cable, our A.V.C. Switchboard Bus Cable matches Rockbestos Switchboard Wire in appearance and characteristics. See page 41. The use of this family of switchboard wires insures a matching appear ance without painting and makes possible a real fireproof wiring job.
n
RBB 00315
ROCKBESTOS
11
SPECIAL EQUIPMENT
Motion picture projectors are typical of certain classes of apparatus in which wire is exposed to extremely high tem peratures as well as a high degree of fire hazard. Tempera tures of 400F. are not uncommon and the wire used in these installations must possess and maintain absolute incombustibility. In addition a high degree of flexibility is frequently required. The Rockbestos Extra Flexible All Asbestos Apparatus Cable shown on page 52 meets ail of these requirements -- it cannot grow hard or brittle under the attack of heat, remains pemaoently flexible and positively will not bum.
RAILROAD SIGNAL TOWERS AND SWITCHBOARDS
Signal towers are the nerve centers of railroads and their
smooth and uninterrupted operation is a vital necessity.
Many towers contain hundreds of thousands of feet of wire
concentrated in a comparatively small space. Wherever
wires are massed or banked togtfher, as they are in signal
towers and on the backs of switchboards, a fire hazard
exists and it is becoming more and more common for signal
engineers to insist upon a genuine fireproof wire for this
use regardless of accepted standards of application. Rock
bestos A.V.C. Signal Wire described on page 58 is both
heatproof and fireproof.
*
SECONDARY NETWORK CABLE
The modern method of distributing power in densely populated communities is by means of a low voltage A.C. secondary network distribution system. Power is distributed at the using voltage, currents are heavy and the load is fed from several sources. The successful operation of a system of this kind requires that when cable faults occur they shall clear themselves cleanly and quickly with a minimum of burning and the cable shall not produce smoke, or explosive, inflammable or toxic gases. Rockbestos A. C. Secondary
Network Cable was developed as a single-purpose cable for this applica tion. It cannot burn, cannot pro duce smoke or inflammable or toxic gases, clears cleanly and quickly under fault conditions. The unre touched illustrations show what oc curs under fault conditions. The lead sheath has partially melted off
the two top cables and the one in the lower foreground reveals an un burned tube of insulation which was left when the copper melted out. The illustration below shows the fault point of a cable from which the cop per melted and ran out, leaving several inches of hollow insulation. See page 62.
RBB 00316
12
ROCKBESTOS
GENERAL CHARACTERISTICS and
ANSWERS TO COMMON QUESTIONS
WHERE SHOULD ROCKBESTOS WIRES BE USED?
Wherever electric wiring is exposed to heat, heat and moisture, fumes, vapors, oil, grease or fire hazard. Throughout industry there are places where wiring is unavoidably exposed to some of these conditions.
In power stations and industrial plants interruptions to service frequently occur because wire insulation fails due to heat, fumes, vibration or age or a combination of these conditions. The use of Rockbestos wires reduces to a minimum failures from these causes because Rockbestos insulation, being inorganic, is highly resistant to these deteriorating conditions.
It is especially important to note that Rockbestos insulation does not dry out with age nor grow hard or brittle, consequently Rockbestos wire can be installed on a truly permanent basis.
IS ROCKBESTOS JUST ANOTHER NAME FOR "SLOW-BURNING" WIRE?
Not at all. Slow-burning wire -- sometimes referred to in error as "that hard, white asbestos wire" -- contains no asbestos whatever.
Slow-burning wire is made by applying two or three cotton braids to a wire and finishing each braid with flameproof paint. The flameproof paint finally dries up, crumbles and separates from the braid because the braid was not impregnated but simply painted with it.
The basis of Rockbestos insulation, on the other hand, is the felted wall of asbestos. This felted wall is formed as a continuous impregnated insulating sheath -- uniform in thickness, firm, dense, highly compressed yet flexible and without laps, joints or seams.
The ability of asbestos to withstand heat is unquestioned, so the felted wall is not merely a flameproof but a real heat resisting insulation. Even when subjected to- continuous high temperature there is practically no deterioration -- it does not grow hard or brittle -- does not crack. These non-deteriorating characteristics make Rockbestos unique among wire insulations.
The insulating compounds with which the felted wall is impregnated ate chemically neutral and were especially developed for asbestos insulation. They are ah integral part of the felted wall-- not painted on afterward -- and, like asbestos, they retain their characteristics indefinitely. The felted wall of asbestos is permanently flexible.
Rockbestos A.V.C. insulation is the felted wall of asbestos as just described, reinforced with an embedded high dielectric insert.
The characteristics of our insulations are such that the impregnating compounds will not drip from the wire at any temperature. At extremely high temperatures -- 400 to 600 degrees F. for example -- our impregnating compounds begin to vaporize and at the melting point of coppet -- 1083 degrees C. -- they will have entirely disappeared, along with the water of crystallization of the asbestos, leaving a perfectly dry tube of insulation which usually covers the conductor but lacks mechanical strength. Exception: Rockbestos A. C. Secondary Network Cable, see page 62.
Slow-burning wire has low moisture resistance, yet a good deal of it has been put into conduit in hot places under the mistaken impression that it was Rockbestos. Naturally when condensation occurred, as it almost always does in conduit at some time or other, the moisture found its way through the cotton braided coverings, causing grounds and short circuits.
Rockbestos A.V.C. insulated wire and cable on the other hand is distinctly suitable and recom mended for conduit installations. It will successfully resist heat, moisture, fumes, oil and grease and it positively will not burn or transmit flame under any conditions.
IS THERE ANY RUBBER IN ROCKBESTOS INSULATION?
No. There is, however, a similarity of appearance between a felted wall of asbestos impreg nated with black insulating compound and a rubber belt insulation. Gose inspection of the former, however, reveals its fibrous nature.
Except in wires and cords for special applications, such as heater cord and some railway wires in which rubber is adequately heat protected with asbestos, we use no rubber whatever in Rockbestos wires. That is because rubber has distinct temperature limitations and is unsuitable for use where a fire hazard exists.
RBB 00317
ROCKBESTOS
. HEATING CABLE
This cable is ideal for many applications where a mild heat must be districted even ly over a fairly large area, and can often be used to better advantage than spot, space or strip-heaters. Rockbestos Industrial Heating Cable, origin ally developed'as a heat source for the forc ing of early spring plants in hotbeds and propagating bendies, has been used by a number of our customers for the economical reduction of heat-loss. They found that by winding it around pipes, liquids could be kept flowing at points where they congealed. Soap, paint, varnish, chocolate, molasses, ink and sulphur are easily kept at the right con sistency to prevent clogging of conveyor pipes. A steel mill uses it on roll-necks to prevent lubricants from congealing. A power company used a quantity of Rockbestos Heating.Cable in a set of specially designed trash racks in one of its hydro-electric power stations to prevent needle-ice from sticking to the bars. In a most unique installation, the heating cable was embedded in a section of cement side walk for the purpose of keeping it free of snow and ice. Some plants use Rockbestos Heating Cable to prevent wet pipe sprinkler systems, waste pipes and water lines in unheated areas from freezing. Gutters and down spouts can also be kept free and clear of ice with it. See page 64.
9
EXTENSION CORD
For general extension work where cord is dragged over floors, sharp corners, stones, gratings, etc. nothing excels a good rubber jacketed cord. However, in some places where other conditions, such as heat, oil or grease, deteriorate the cord and cause failure, we recommend Rockbestos A.V.C. Flexible Cord shown on page 56. For use in dry locations such as on cord pendants, the All-Asbestos Flexible Cord on page 55 will be satisfactory.
HEATING APPLIANCES
For years we have furnished fine heater cord to many of the country's largest manufacturers of domestic heating appliances. We have also furnished heater cord for many industrial heating appliances such as soldering irons, glue pots, hot plates, heavy flatirons, branding irons, as illustrated, and many spedaL heating forms used in the shoe industry. The cords on these appliances are subject to a good deal more than ordinary wear so that when we recom mend Rockbestos Heavy Duty Heater Cord for these uses, we do so knowing that its use will cut down replacements and cord expense. See page 37.
RBB 00318
10
ROCKBESTOS
LIGHTING FIXTURES
Modem fixture design has produced gas filled high wattage units, indirect lighting and flush type fixtures in which the wire enter ing the socket is exposed to temperatures ranging between 50 and 20OC. The resulting induced heat creates high conductor temperatures from 3" to 12" back from the socket which dry out and crack ordinary insulation. Under such conditions uninter rupted service can be assured only by wiring with a genuinely heatproof wire. For office and domestic fixtures Rodcbestos single conductor heat resisting fixture wire is.recommended. See detailed information on page 53- For cord pendant fixtures the permanently insulated heat resisting Rockbestos Flexible Cords described on page 54 will be found useful. Power company and industrial plant electricians have installed millions of feet of Rodcbestos A.V.C Boiler Room Wire in the lighting circuits of boiler rooms, engine rooms, kiln rooms, steel nulls and other hot places where it is giving trouble-free service. Many electridans run this same wire right into the lighting fixtures, which gives them heatproof wiring from the distribution panel to the socket terminals. Although Rockbestos Boiler Room Wire is a little larger than the wire ordinarily used, industrial fixtures usually have enough dearanee to accommodate it. See page 25.
NOTE:--Allied to lighting fixtures is the problem of providing the higher currents required by the increase, during the last few years, of the average wattage of lighting fixtures and the increase in the number of fixtures. Frequently the size of the conduit originally installed will not permit an increase in the size of the feeders. A solution in a number of cases has been to replace the old feeders, usually rubber-covered wire, with A.V.C. wires which have a higher carrying capacity rating and can be operated under higher conductor temperatures. Our engineering department will gladly make recommendations.
PYROMETER LEADS
Wherever pyrometers are installed there are high temperatures to which the wiring is usually exposed. Rockbestos insulated pyrometer wires, with their de sirable heat resisting and fireproof characteristics, are being increasingly used throughout industry for py rometer leads and fire-ends. See page 60.
INTERCOMMUNICATING, SIGNAL AND TEMPERATURE CONTROL CIRCUITS
Rockbestos Thermostat Control Wire has the perma nent heat resisting and fireproof characteristics of our other wires and cables. It fills a demand for a small armored signal and control cable for use in steel mills and industrial plants where permanent installations are essential. See page 61.
RBB 00319
13
-------------- = ROCKBESTOS =====
HOW MANY TYPES OF ROCKBESTOS INSULATIQN?
There are two standard types --
^
(a) Rockbestos A.V.C insulation, a construction originated, developed and patented by Rockbestos (U. S. Pat. No. 1,840,282 -- 1,861,404) consisting of a felted and impregnated wall of asbestos with an insert of high dielectric material embedded in it.
(b) Rockbestos AU-Asbestos insulated wires on which the coveting consists of a felted and impregnated wall of asbestos.
Both types are usually finished with braided coverings of asbestos or cotton yarn.
IS ROCKBESTOS SUITABLE FOR CONDUIT INSTALLATIONS?
Yes.- Rockbestos A.V.C wire is designed for conduit installation. See detailed recommendation beginning on page 14.
Rockbestos A.V.C. wire is impregnated to successfully meet moisture conditions in conduit such as are caused by condensation. While it is not a submarine type of wire it has ample margin of safety for all ordinary conduit moisture. In locations where it is known that wire will be sub merged for long periods we recommend lead sheathed A.V.C. constructions.
ARE ROCKBESTOS WIRES BIGGER THAN OTHER TYPES?
In the larger sizes Rockbestos cables run slightly smaller in diameter than other types. In all but a few cases involving the smaller size wires, the same size of conduit which will accommo date a given number of other types of wires, will also take a like number of Rockbestos A.V.C. wires or .cables.
For specific conditions see conduit size -tables for Rockbestos Boiler Room Wire and Power Cables on pages 21 to 24.
WHAT ARE THE CARRYING CAPACITIES OF ROCKBESTOS WIRES?
Rockbestos wires and cables have greater carrying capacity than other types of insulated wires because of the well known heat-resisting characteristics of asbestos which is the basis of Rockbestos insulation. Specifically, a given size of Rockbestos insulated conductor will carry a higher current than other types of insulated wires. Conversely, where a given current is to be carried a smaller size Rockbestos wire can be safely used than would be required with wire having other types of insulation. See Table of Allowable Current Carrying Capacities on reverse side of Rockbestos Calcula tor in the back of this catalog.
WHAT IS THE VOLTAGE RANGE OF ROCKBESTOS WIRES?
Rockbestos wires and cables can be supplied for rated voltages up to 5000.
WHAT IS THE SIZE RANGE OF ROCKBESTOS WIRES AND CABLES?
The Rockbestos line includes various single conductor constructions ranging up to 2,500,000 C.M. in size. Multiple conductor cables can be manufactured up to a diameter of approximately 2inches.
ARE ROCKBESTOS WIRES APPROVED BY THE UNDERWRITERS?
Yes. All types of wire shown in this bulletin, which come within the jurisdiction of the Under' writers' Laboratories are approved.
CAN LEAD AND ARMOR COVERINGS BE SUPPLIED?
Anv Rockbestos wire can be so supplied. Specify lengths desired, otherwise prices will be figured on standard shipping lengths. Lead Sheathed 600 Volt A.V.C. Power Cable is illustrated on page 28, specification information on other types on request.
STANDARD SPECIFICATIONS FOR ROCKBESTOS WIRES
See page 15 under "How to Select or Specify the Proper Rockbestos wire."
RBB 00320
14
-
- ROCKBESTOS
HOW TO SELECT OR SPECIFY
THE PROPER ROCKBESTOS WIRE
GENERAL
There are two standard types -of Rodcbestos wires which are specifically recommended to fulfill the usual service conditions of conduit and open wiring:
1. A.V.C. Insulated Wires, Cables and Cords. 2. All-Asbestos Insulated Wires, Qbles and Cords. In addition to these there are special types which have been developed to meet unusual condi tions in which some particular characteristic must be emphasized. These involve the use of other materials such as rubber, synthetic-resins, glass, etc., in combination with asbestos.
FOR CONDUIT INSTALLATION
For all conduit wiring we recommend the A.V.C group of wires, cables and cords. These have been designed especially for conduit installation and wherever there is a possibility of moisture collecting around the wire.
A.V.C insulation has much higher dielectric strength than an equivalent thickness of felted asbestos alone, consequently possesses the necessary extra margin of dielectric strength to stand up without failure under moisture. We have service records on many millions of feet of Rockbestos A.V.C. wires and cables, in both single and multiple conductor form, installed in the conduits of power companies, steel mills, industrial plants, kiln rooms, electrified mining equipment, oil refin eries, marine boiler rooms and continuous ovens and successfully meeting conditions of heat, fumes, oil, grease and fire hazard.
FOR OPEN WIRING
In dry places we recommend the All-Asbestos wire. It is ideal to use on rheostats -- con nections between grids and from grids to faceplates--for exposed lighting and control circuits, etc.
For locations where open wiring will be exposed to high humidity, steam, etc., use same recom mendations as given above for conduit wiring.
IMPREGNATION AND BRAIDS
In general the felted asbestos insulating walls of all Rockbestos wires, cables and cords are impregnated with a chemically neutral, black insulating compound which is heat, moisture and flame resisting. Wherever identifying colors are required on wires having no outer braid the insulation can be furnished in white, black or plain colors.
Braids, whether they be asbestos or cotton, are also generally finished black, but white or colored finishes can be supplied on special order.
In special cases where a wire will be exposed only to extremely high temperatures and no moisture and where maximum flexibility is desired, white compound may be used both in the im pregnation of the felted asbestos walls and for the finish of the braid. A felted wall so impregnated is slightly more flexible than when impregnated with moisture resisting compound. Extra Flexible Apparatus Cable illustrated on page 52 provides an example of this construction.
If wires are to be exposed to oil or grease it should be mentioned in the specifications to insure the use of the proper compounds in impregnating the insulation.
d
RBB 00321
ROCKBESTOS
SPECIAL BRAIDS AND FINISHES
On any of the standard wires shown in this catalog special cotton twine, linen or jute braids can be substituted if necessary. Also a variety of special finishes such as lacquer, wax, asphalt or aluminum paint, can be applied to any selected braid.
SPECIAL CONDUCTORS
The following pages show our standard conductors for the various types of wires. On special order we can supply other types of conductors as to material, stranding, tinning, plating, etc. Alloy conductors for pyrometer wire must be supplied by the customer.
LEAD AND ARMOR COVERINGS
Any wire of our manufacture can be furnished with lead sheath, basket weave metal armor, interlocking steel or bronze armor or almost any type of special covering. Give complete specifica tions and state cutting lengths on order.
SPECIAL CONSTRUCTIONS
We fabricate special insulations to meet unusual conditions. If your requirements do not seem to be met by any of the types of wire described in the following pages, we will be glad to work out a construction to meet your particular conditions.
STANDARD SPECIFICATIONS FOR ROCKBESTOS A.V.C.
AND ALL-ASBESTOS WIRES AND CABLES
Many companies in adopting Rockbestos insulated wires and cables have requested suggestions for a standard specification. We present the following specification outline which covers all standard types of Rockbestos wires and cables and offer it for your use.
NOTE: This specification summarizes the National Electrical Manufacturers Association Standard for Asbestos and Asbestos--Varnished Cambric insulated Wires and Cables with which all Rockbestos wires and cables of standard construction comply. Copies of the NEMA Standard may be obtained by writing to National Electrical Manufacturers Association, 155 East 44th Street, New York City.
I General (a) Purpose: The purpose of these specifications is to insure the furnishing of wire and cable of the best quality, manufactured in accordance with best accepted prac tice.
(b) Scope: These specifications cover the manufacturing and test requirements for all asbestos and asbestos--varnished cambric insulated wires and cables.
(c) Materials and Workmanship: All materials and workmanship involved in manufac turing wires and cables covered by these specifications shall be of high quality, care fully selected to insure a finished product best suited for the purposes intended.
(d) Applications A.V.C. Insulations. Suitable for use at voltages up to 600, 1000, 2000, 3000 and 5000, open or in con duit, in locations where wiring is exposed to heat and moisture. The high-dielec tric varnished cambric insert, adequately heat-sealed by the felted asbestos, pro vides ample protection against casual moisture.
Where complete submersion is encountered specify lead sheathed cables.
15
RBB 00322
16
ROCKBESTOS
Standard Specifications -- Continued
AIl*Asbestos Insulations.
Suitable for use at voltages up to 300 or 600, as specified, for exposed wiring in high temperature locations where little or no moisture is encountered. Impreg nated with either flame and heat resisting, or flame, heat and moisture resisting compounds. Specify preference.
II Conductors (a) Conductors shall be of tinned or plain copper in accordance with ASTM Specifica tions B33-39 or B3-41 respectively, or latest revision thereof.
(b) Stranded conductors shall be concentric or rope lay as required. 1. The make-up of stranded or flexible conductors shall conform to accepted stand ards wherever practicable.
(c) Conductors other than copper shall be specified to meet individual requirements.
(d) Standard enameled copper shall meet the requirements of ASA Spec. C8.7--1936 insofar as it applies.
*=3 III Insulation (a) Asbestos 1. Material. The asbestos insulation shall consist of best quality, long fibre, chrysotile asbestos commercially free from foreign particles of dirt, cotton seed and metallic oxides. It shall be well carded to prevent lumps and irregularities in the finished cable.
The asbestos insulation after extraction of the impregnating compound shall con tain not less than 80% by weight of asbestos. The total iron content shall not exceed 4% by weight of the asbestos and the magnetic iron content shall not ex ceed 2% by weight of the asbestos.
The wall of felted asbestos insulation shall be applied to form a smooth wall of uniform thickness as specified in the tables, with the conductor well centered.
2. Impregnation. After the asbestos has been applied to the conductor it shall be thoroughly dried and completely saturated with flame-resisting and heatresisting or moisture resisting compound as specified, then compressed and polished to form a dense, uniform felted asbestos wall of the specified thickness. The impregnating compound shall consist of suitable high grade ingredients and shall retain its initial qualities during the normal life of the cable. Tlie compound shall develop no injurious chemical reaction within itself or with any component parts of die cable.
RBB 00323
===== ROCKBESTOS
Standard Specifications -- Continued
(b) Varnished Cambric 1. Material. The varnished cambric insulation, where used in these wires and
cables, shall consist of a high grade varnished cloth substantially free from blisters or other imperfections. It shall comply with the requirements for varnished cloth in existing NEMA Standards for Varnished Cambric Insulated Cables, ex cept that test requirements on tape removed from the finished cable shall be 60% of the values on unused tape.
2. Application. The varnished cambric insulation shall be applied with lubricating
compound between layers and to the wall thickness specified.
17
IV Braids
(a) Asbestos 1. Material. The asbestos from which the yam is made shall be of good quality long-fibre chrysotile asbestos which meets the requirements of ASTM specifica tion D-375-42 Underwriters' Grade, containing not less than 80% by weight of as bestos. The total iron content shall not exceed 6% by weight of the asbestos. The magnetic iron content shall not exceed 2% by weight of the asbestos
2. Application. Asbestos yarn of the proper number of ends to insure a uniform
smooth covering of the thickness specified, shall be closely woven into an asbestos outer braid.
3. Saturation. Asbestos outer braid shall be saturated with either a suitable flame
and heat resisting, or flame, heat and moisture resisting compound as specified.
(b) Cotton
Cotton braids shall be closely woven of the proper number of ends of thread to insure a uniform smooth covering, and shall comply with the Standard Braid re quirements of ASA Specification for Cotton Braid for Insulated Wires and Cables, C8.12-1935 or the latest revision thereof. Outside cotton braids shall be finished with either a suitable flame and heat resisting compound, or saturated and finished with a flame, heat and moisture resisting compound as specified.
V Finishes
(a) Classification. The outer covering of wires and cables under this specification,
whether plain felted asbestos or braid covered, shall be finished to show a smooth even surface of uniform color as specified and shall enable the finished wire to meet the test requirements specified in the following paragraphs 1 and 2. The following classification indicates the type of finish required for different classes of wire.
RBB 00324
ROCKBESTOS
Standard Specifications -- Continued
1. Flame and Heat Resisting. This finish shall be standard for white or colored braided All-Asbestos insulated wires. It shall consist of suitable compounds to produce a smooth tough outer finish. It shall not be specified on wires sub jected to moisture conditions.
2. Flame, Heat and Moisture Resisting. This finish shall be standard for black, white and colored A.V.C. wires and for black All-Asbestos braided wires and cables. It shall consist of saturating the insulation or braid with black, white or colored flame, heat and moisture resisting compound.
VI Special Coverings
.
(a) Special coverings such as spiral, basket weave and interlocking armor for unusual applications shall be so specified on the order with applicable specifications. Cut ting lengths should also be stated.
(b) Lead Sheath. The lead sheath shall consist of commercially pure lead (unless an alloyed sheath is specified) and shall be tightly formed around the core. It shall comply in all respects with the requirements for lead sheath appearing in exist ing NEMA Standards for Varnished Cambric Cables. The thickness shall be in conformity with that required for varnished cambric cables of corresponding core diameter.
VII Cabling
(a) For cables consisting of more than one conductor (except flat twin cables) the separately insulated conductors shall be concentrically cabled together. The lay of the conductors in each layer shall not exceed 16 times the diameter over that particular layer. The lay of the conductors in each successive layer shall be reversed and the outer layer shall have a left hand lay.
(b) The single conductors shall have A.V.C. or All-Asbestos insulation as indicated on the order. For circuit identification the insulation of the individual conductors shall be impregnated with colored compounds or covered with cotton or rayon marker braids coded to the NEMA color chart.
(c) When required, fillers shall be used and shall be of jute or asbestos, dry or impreg nated with a moisture resisting compound as specified on the order.
(d) In cables with coded conductors and elsewhere when required for manufacturing reasons, the cabled conductors shall be wrapped with tape.
VIII Tests
A. Physical
1. Materials. The various materials used in the manufacture of wires and cables under this specification, shall meet the requirements listed in the individual sections.
O
RBB 00325
ROCKBESTOS
Standard Specifications -- Continued
2. Finished Product (a) Dimensions. Inspection for dimensional requirements shall consist of four measurements, two to be made near each end of the sample of which the average shall comply with the requirements given in the tables. The measurements of cable %" in diameter and smaller shall be made with a ratchet micrometer having 14" diameter faces. For cable larger than in diameter the measurement shall be made with a circumference tape. Diameter determinations when made with the micrometer shall be the average of two measurements made at right angles to each other. The average diameter over any component layer of the insulation and braid shall not vary more than plus or minus 5 percent from the theoretical dia meter over that layer based on the nominal wall thicknesses shown in the table.
(b) Resistance to Flame. All of these wires and cables shall have such fire resisting properties that the test specimens will not convey flame, nor con tinue to burn for more than one minute after five fifteen second applica tions of a standard test flame, the period between applications of the flame being fifteen seconds. NOTE: Compliance of the wire with the requirements of the preceding paragraph shall be determined with the apparatus and according to the methods described in paragraphs c and d.
(c) Apparatus for Testing Flame-Retarding Properties. The apparatus for this test consists of a test chamber of sheet metal 12" wide, 14" deep and 24" high, open at top and front and provided with means for supporting the test sample in a vertical position. A Tirrill burner having a bore of and a length of 4" above the primary air inlets, a 20 angle block for supporting the burner, a supply of ordinary illuminating gas at normal pressure, a watch or clock with a hand which makes one complete revolu tion each minute and flame indicators consisting of strips of gummed Kraft paper 5 mils in nominal thickness and I/2" in width.
(d) Method of Testing Flame-Retarding Properties. The test is made in a room from which all drafts are excluded. An 18" sample of wire is sup ported from the upper end in the test chamber and is held in vertical position by a four pound weight attached to the lower end of the wire. A paper indicator is applied to the sample so that the lower edge is 10" above the point to which the flame is to be applied. The indicator is wrapped once around the sample with the gummed side toward the con ductor and the ends pasted evenly together and projecting %" away from the wire, on the opposite side of the wire to that to which the flame is to be applied.
19
RBB 00326
20
ROCKBESTOS
Standard Specifications -- Continued
The height of the flame with the burner vertical is adjusted to 5" with an inner blue cone U/2" high. The burner is then tilted to an angle of 20c from vertical and the flame applied to the sample so that the tip of the inner blue cone touches the sample at a point approximately 3" above its lower end. The side of the flame is brought up to the sample in such a manner that the vertical plane through the axis of the burner is perpen dicular to the line of approach. The flame is applied for 15 seconds and then removed for 15 seconds. This process is repeated four times.
If more than 25% of the extended portion of the indicator is burned, the wire is considered to have conveyed flame.
B. Electrical 1. Initial Dielectric Strength Tests (a) All wires and cables specified herein and rated at 600 volts or more: Test voltages as specified in the tables. Test to be made on 5 ft. lengths of finished cable with the center 3 ft. section wrapped in metal foil, voltage to be applied five minutes.
(b) 300 volt rated wires and cables: One thousand volts applied for one minute. Test to be made on 5 ft. lengths of finished cable with the center 3 ft. section wrapped in metal foil.
2. Dielectric Strength After Flame Tests.
Samples of cables having been previously subjected to the Flame Test shall
a:; be prepared with the charred area of sizes No. 6 and larger wrapped in metal foil, and sizes smaller than No. 6 buried in iron filings or fine shot and tested for one minute as follows:
(1) Asbestos -- varnished cambric insulated wires and cables rated at 600 volts or more, 1 1/2 times rated voltage.
(2) All-Asbestos insulated wires and cables rated at 600 volts, 2l/2 times the rated voltage.
(3) 300 volt rated wires and cables, 1000 volts.
3. Dielectric Strength While Immersed. A 5 ft. sample of finished cable having flame, heat and moisture resisting finish shall be immersed, except ends, for one hour in tap water at room temperature and while still immersed, shall withstand a dielectric test of twice the rated voltage between conductor and water for one minute.
IX Sampling
(a) Each of the required tests shall be made on one sample of each size and type of wire from each lot of 10,000 feet or fraction thereof, unless other wise specified.
(b) If a sample fails to meet any of the prescribed requirements, two addi tional samples shall be taken from the same length. If either of these samples fail the length may be rejected.
(c) If any of the lengths fail to meet any of the requirements, samples shall be taken from each length or reel of the lot and tested for this particular requirement to determine acceptance of each reel.
RBB 00327
= ROCKBESTOS =
21
CONDUIT SIZE TABLES
TABLE C 600 VOLT A.V.C. BOILER ROOM WIRE
O. D.* Sine in
Inches 1
2
NUMBER OF WIRES
3 4| S 6 7
A.W.G.
MINIMUM SIZE OP CONDUIT
It
16
10
-220 Vi
.235 Vi
Vi
.265
Vi
.215
Vi
Vi Vi
Vi Vi Vi
Vi
Vi Vi Vi Vi
Vi Vi Vi 1 1
Vi 1 1
1 1
ii
i IVi IVi
l 1i
IVi IVi
Vi Vi Vi 1
IVi IVi IVi
$
465 .405
Vi
Y)
1
1
1 IVi
IVi IVi
IVi IVi
IVi IVi
2Hi'
4
S
.425 .450
a Vi
1 1
IVi IVi IVi 2 IVi IVi IVi 2
2
2
.4*0
Vi
Wi
IVi
IVi
2
2
2
1
0 00 0000000
430 Vi iVi IVi 2 2 2 2Vi
.565 Vi IVi m 2 2 2Vi 2Vi
.60S
IVi IVi 2
2Vi 2Vi
450 1
2 2 2Vi 3 3
.700 1 IVi 2 2V4 3 3 3
' Subject to pin* or minus i% tolereace due to variations in manufacturing processes.
8
t
iVi IVi IVi IVi IVi 2 2 2 2 2Vi 2Vi 3 3 3 S
9
1 IVi IVi IVi Hi IVi 2 2
2 Vi 2 Vi 3 3 3 3 Vi 3 V
TABLE E 600 VOLT A.V.C. POWER CABLE
O. D.* Size in
Inches 1
2
NUMBER OF WIRES
345 6 7
MINIMUM SIZE OF CONDUIT
A.W.G.
U
.255 Vi
Vi Vi
Vi .215 Vi
Vi
Vi
Vi Vi
.305 495
Vi Vi Vi
Vi
V,
1
i y* i i
iVi i i
i
n/4 IVi
1 1 1 Vi
IVi IVi IVi
i
Hi IVi IVi IVi
IVi
IVi Hi 1VS
.420 Vi IVi Vi IVi
.470 V* w
IVi IVi IVi
IVi
H/.
IVi
IVi IVi 2
2
2
.505 Vi IVi IVi IVi 2 2 2 Vi
.565 Vi IVi IVi 2
.625
IVi 2
2
2Vi 2Vi 2 Vi 2Vi 2Vi 3
00 .670
000 .720 1
22 22
2Vi 2 Vi 3
2Vi 3
3
3
0000 250.000C-M.
.7S0 .665
IVi IVi
22 2Vi 2Vi
2Vi 3
3 3 Vi
3 3 Vi
3Vi
300.000 .940 IVi 2Vi 3 3 3 Vi 4
350.000 400.000 450,000
.995 1.040 1.065
IVi IVi IVi
3 3
4
3 3 3
3 V, 3 Vi 4
Vi
3 Vi 4
Vi Vi
3 Vi 4
Vi
500,000
1.125
IVi
3
3
4
4
Vi
550.000
1.165
IVi
3
3 Vi 4
Vi
600,000
23
3 Vi 4
Vi
650.000 700,000
1440 1.275
2 2
IVi 3 Vi 4
Vi
3Vi 3y. 4Vi 5
750.000
100.000
1.310 1445
2 2
3 Vi 3 Vi Vi 5
SVi 4
Vi 5
650,000
1475
2
3 Vi 4
Vi 5
930.000
1.000.000
1.405 1.435 1.465
2 2 2
4 4 4
4 4 4
Vi 56 56
6
* Subject to plu* or minus 5% tolerance due to variation* in manufacturing processes.
8
IVi Hi IVi IVi IVi IVi 2 2 2 2Vi 2Vi 3 3 3 3 Vi SVi 4 Vi Vi 5
9
IVi Hi IVi IVi IVi 2 2 2 SVi 2Vi SVi 3 3 3 Vi 3Vi
Vi Vi
RBB 00328
22
- ROCKBESTOS =
CONDUIT SIZE TABLES
TABLE EL 600 VOLT LEAD SHEATHED A.V.C. POWER CABLE
Size
O. D.* in
Inehee
1
2
NUMBER OF WIRES 3|4 | 5 16
7
MINIMUM SIZE OF CONDUIT
A.W.G.
it
.290 54 Y, Y* i
154 154 154
.505 y
Yt 1
.320 54
l
i
.340 54
l
l
.360 */,
l
l
i iy* iy* 154
t iy* iV*
iV* i y*
154
iy* iV* 154 m
54 iy. iy* iy. 2
54 m iy* 154 2
.450 V. .480 Y*
154 154
i y* iy*
154 iV,
2 2
2 2 2
254
Y. iy* i y. 2 2 214
1
Y* .620
l
164 1V, 2
iy, 2 2
2 2 254
2V, 254 3
254 3
2 254 3 1 2 2 y. IV, 3 354
260.000 C.M, .955
i y* m 154
I 54
IV, 3 3 3
254 3 3 3
3 3V,
354 3 v%
3V, 4 4 4
314 454
454
400.000
1.105
iy.
3
3
4J0.000 500.000
1.150
IV,
3
3 Vi
1.190
2
iV, ty> 4
4V, *v.
1.265
2
tv. tv. 4 V, 5
600.000
1.305
2
3y, 4
4/, 5
1.340 2
tv. 4
4V4 6
1.375
2
4
4
*v
750.000
1.410
2
4
4
800.000
1.440
2
4
4
t,000
1.490
2
4
4
900.000
1.505
254
4
4 V,
950,000
1.535
2y.
454
1,000.000
1.560
ty.
4 V,
4/,
6
6
* Subject to plus or minus 5% tolerance due to variations in manufactures processes. ** Sizes No. 12 A.W.C. and smaller can be supplied with 2/64' lead.
8
154 154 1*4 2 2 2
254 3 i3U14
9
i 5, 154 2 2 2 2
214 25, 3 3
3*4 4
TABLE EM 1000 VOLT A.V.C. POWER CABLE
Size
O. D.* in
Inches
1
A.W.G. 18
6 Z 0
.285
did
.425 .450
.535 .615 .655 .700
.810 .895 .950 1.00$ 1.0S0 1.095 1.135 1.175 1.215 1.250 1.28$ 1.320 1.35$ 1.415 1.475
54 54 14 54 14 54 54 V,
iY)
i i
154 154 154 154 154 154 154 2 2 2 2 2 2 2 2
2
V* V* Y*
154 154 \Yf 154 m xy, 2 2
2 2y, 254 3 3 3 3 3 354 354 354 354 354 4 4
NUMBER OF WIRES
3 | 4j S_
6
7
MINIMUM SIZE OF CONDUIT
V* l Y* i
l
i iy. iy. 154 154 154 154 154 154
154 iV* iy 154
154 154 1 154
154 154 154
154 154 iy.
iy. 154 2 2 2
& 154 2 22
2 2H 254 254
S32 254
2y, 3
2 354 3 3
2 354 3
254 3
354
354 3
354
32
3
354 45C
3V,
34
354 4
*54
354
354 4
<54
354 414
354 4V,
4 4y.
4
4 66
* Subject to plus or minus $% tolerance due to variations in manufacturing processes.
8
154 iy 154 154
254 254 2y, 3 354
454
9
1V4 m iy. 154
254 254 254 3 3
4*
RBB 00329
=== ROCKBESTOS
-
CONDUIT SIZE TABLES
TABLE F 2000 VOLT A.V.C. POWER CABLE
Size
O. D.* in
Inches
1
2
NUMBER OF WIRES 3 4[5 16
7
MINIMUM SIZE OF CONDUIT
A.W.G.
14 .335 *4 l i 1*4 1*4 1*4 1*4
12 .383 y. i i 1*4 1*4 1*4
10 .410 'A i 1*4 1*4 1*4 1*4 2
8 .440 y. I Vi 1*4 1*4 1*4 : 2 2
6
.475 Vt 1V4 1*4 1*4 2 ' 2
2
3
.500
V*
IV*
1*4
1*4
2
2
2*4
4 .525 , 1*4 1*4 2 2 2 2*4
3 .530 V* 1*4 1*4 2 2 2'/. 2*4
2
483 * 1*4 1V4 2
2V4 2V4
2*4
1 .645 1 2 2 2 2 Vi 3 3
0 .683 1 2 2 2*4 2*4 3 3
00
.730 1
2
2
2V4 3
3
3
000
.780 i y.
2
2
3
3
3
3*4
0000
.840 IV. 2*4 2*4 3
230.000 C.M. .925
1V*
2*4
2*4
3
3 3*4 3*4 4
3*4 4
300.000 330.000 400.000 430,000 300.000
.980 1.035 1.080 1.125 1.165
IV* IV* 1*4 1*4 1*4
3 3 3 3 3
3 3*4 3*4 4 4*4
3
3*4 4
4
4*4
3 3*4 4 4*4 3
3 4 4 4*4 5
3*4 4
4*4 3
5
530.000 000.000
1.205 1.245
2 2
3 3*4 4 1*4 3*4 4
4*4 3 4*4 5
5 6
030.000
1.280
2
3*4 3*4 4*4 5
5
6
700,000
1.313
2
3*4 3*4 4*4 5
6
6
730.000
1.350
2
3*4 4
4*4 5
6
6
800.000
1.385
2
3*4 4
4/, 5
6
6
000,000
1.445
2
4
4
3
6 .6
6
1.000.000
1.305
2
4
4
5
6
6
* Subject to plut or minus $% tolerance due to variations in manu/aeturing processes.
8
2 2 2
2*4 2Vi 2*4 2*4 3
3 3*4 SV. 4 4*4 4*4 5 3 3 6 6 6 6 6 6
9
2 2 2 2*> 2*4 2*4 3 3 3 3 3*4 3*4 4 4 4 *4 3 5 6 6 6 6 6
TABLE G 3000 VOLT A.V.C. POWER CABLE
Size
O. D.* in
Inches
1
2
NUMBER OF WIRES 3 4 15:6
MINIMUM SIZE OF CONDUIT
A.W.G.
14 .425 *4 1*4 i*4 m 1*4 , 2 2
12 10
.445 .470
%*4
1*4 1*4
1*4 1*4
1*4 1*4
1*4 : 2 22
2 2
8 .300
1*4 1*4 1*4 2
2
2*4
6 .333 y. 1*4 1*4 2 2 2V, 2*4
5 4
.360 .583
V. *2
1*4 1*4
1*4 1*4
2 2
2 2*4 2'4 2'4
2*4 2*4
3
.610 i
1*4 1*4 2
2*4 2*4 3
2 i 2 2 2 2*4 3 3
1 .705 i 2 2 2*4 3 ,
3
0 .745 i 2 2 2*4 3
3*4
00
.790 1*4
2
2*4 3
3.
3*4
000 .840 1*4 2*4 2*4 3 3 3*4 3*4
0000
.900 1*4 2*4 2*4 3
3*4 j 3*4
230.000 C.M. .985
1*4
3
3
3*4 3*5 I 4
4*4
300.000
1.040
1*4
3
3
3*4 4 ; 4*4 4*4
330.000
1.095
1*4
3
3
3*4 4 i 4*4
3
400.000
1.140
1*4
3
3
4
4*4 ' 4*4
3
430.000
1.185
2
3
3*4 4
4*4 l 5
3
500.000
1.225
2
3*4 3*4 4
4*4 ; 5
6
530.000
1.265
2
3*4 3*4 4
4*4 3
6
600,000
1.305
2
3*4 3*4 4*4 5
6
650.000
1.340
2
3*4 3*4 4*4 5 1 6
700.000 730,000
1.375 1.410
2 2
3*4 4 44
4*5 5 ; 6
4*4 5
6
6
800.000
1.443
2
4
4
3
e 16
6
900.000
1.505
2
4
4
5
6
6
1.000.000
1.365
2*4
4
4*4 5
6
6
Subject to plus or minus 5% tolerance due to variations in manuiacturing processes.
8
2 2 2*4 i'A 2'/. 3 3 3 3 3*4 i'A i'A 4
4*4 5 5 6 6 6 6
9
2 2*4 2*4 2*4 3 3 3 3 3 3*4 4 4 4 4*4 5 5 6 6 6 6 6
23
RBB 00330
24
ROCKBESTOS
CONDUIT SIZE TABLES
TABLE H 5000 VOLT A.V.C. POWER CABLE
m
Sise
O. D.* in
Inches
1
2
NUMBER OF WIRES 34* 6
*
MINIMUM SIZE OF CONDUIT
A.W.G.
34 .433 *
1*4 1*4
6
.360
Yt H Y<
111*44 lu
1*4 1*4 1*4
1*4 2 2
.620
Y*
1 Vi 1U
1*4 2
2 2
222
2 2 2*4
2 2 2*4
.763 1*4
2
2
2*4
*4 2
2*4 3
4 2*4 2*4 3
\Y1 2V4 2*4 3
230.000 C.M. 1.04$
1*4 w.
2*4 3
3 3
3 3*4
\Y, 3 3 3*4
1*4 3
3*4 4
23
1.243
2
3*4
1.283
2
IV
1.323
2
600.000
1.363
2
3*4
1.400
2
4
1.433
2
730.000
1.470
2
300,000
1.305
2
900.000 1.000.000
1.363
2*4
4*4
1.623
2*4
4*4
4*4
6
22 22
2 2*4 2*4 2*4 2*4 2*4 2*4 2*4 3 3 3*4 3*4 4 4*4
6
2*4 3
4
Subject to plu or misut 3% tolerance due to variation! in manufacturing procetiei.
8
2y,
a
j
3 3 3 3 3*4 3*4 4 4 4 4%
5 s
6
6 6 6 6
RBB 00331
ROCKBESTOS
600 VOLT . A.V.C. BOILER ROOM WIRE
' GENERAL LIGHTING AND CONTROL CIRCUITS, WIRING AROUND OVENS,
- FURNACES. LEHRS, TENTER FRAMES, BOILER ROOMS, SOAKING PITS, ELEVATOR
. AND LOCOMOTIVE CONTROL PANEL WIRING, ETC.
this is THt coamuctioH or tins it to t
this it THt coNtTtueno* or tint to 4i
25
1)41
t. SOLID PLAIN COPPlt CONOUCTOR
l. ftLTtO AIICSTOt
VAftfflSHfO CAB IIMC
4. PlbKO AtlCSTOI
ft. ASICSTOft MAIO
Size A.W.G.
0000 000 00 0 1 2 3 4 5 6 8 10 12 14 16 18
This wire is recommended for open wiring and general conduit work where wiring is or may be subjected to heat, corrosive fumes, oil, grease or fire hazard.
It will operate without failure under constant high temperatures, and at the same time possesses sufficient moisture resistance to operate without failure under average conduit moisture conditions. However, if it is known that parts of a circuit will be sub merged for long periods, use Table EL, Lead Sheathed A.V.C Power Cable shown on page 28.
A.V.C. Boiler Room Wire handies and pulls into conduit the same as any other wire. See Conduit Size Table on page 21.
For the same application, but where a stranded conductor is required, use A.V.C. Power Cable, Table E, shown on page 26.
Recommended also for switchboard wiring when an asbestos braided wire is required.
This wire is National Electrical Code Type AVA, listed by Underwriters' Laboratories.
TYPE AVA--TABLE C--600 VOLT SERVICE (NEMA Standard No. 39*54 Table 37)
Bare Diam.
Nominal Thickness
First Felted Wall
Nominal Thickness
V. C. Insert
Nominal Thickness
Second
Felted Wall
vu> N 35
d
Nominal Finished Diam.*
Approx. Net
Weight
per M ft.
Standard Shipping Lengths
(Feet)
Inches
.460 .410 .365 .325 .289 .258 .229 .204 .182 .162 .128 .102 .081 .064 .051 .040
Mils
15 15 15 15 15 15 15 15 15 15
Mils
30 30 30 30 30 30 30 30 30 30 25 25 25 25 25 25
Mils
sc Inches
Pounds
ta>
i30 th .700
30 .650
30 .605
i30 Q .565
30 .530
20 m .480
20
sc u
.450
20 H .425
20 i-> .405
800 657 543 422 348
279 231 193 160
20 b. .385 20 o .310 20 C/> .285 20 u .265
138 87 62 47
20 .245 20 V .235
i20 .220
38 31 27
Coils
500 500 1000 1000 1000 1000 1000
Reels
450 500 500 500 500 500 1000 1000 1000 1000 1000 1500 1500 2000 2000 2000
* Finished diameters Riven above are averafe. A tolerance of plus or minus
is necessary due to variations in process of manufacture.
NEMA dielectric test voltages in kilovolts, 2.S for sizes 18 to 8 and 3.0 for 6 to 4/0.
RBB 00332
26
ROCKBESTOS
600 VOLT A.VX* POWER CABLE
ASHPITS AND ASH ALLEYS, AROUND SOAKING PITS, FURNACES, OVENS, LEHRS, TENTER FRAMES, STEAM TUNNELS, ALL BOILER ROOM CIRCUITS AND FOR GENERAL HOT-SPOT WIRING
i t>4
I. *T*AK0M PLAIK COMI* CONPUCTO*
X. PCCTCO ASBCfTOI
X. VAMIXttgB CAUStIC
4. FILTXP tllltTOI
S. Atlttroi IIAIB
This cable is recommended for general power circuits as well as for the same applications as given for Table C Boiler Room Wire on the preceding page. A.V.C Power Cable handles and pulls into conduit the same as any other cable. See conduit sue able on page 21- It will operate continuously without failure under constant high temperatures, yet can also meet ordinary conduit moisture conditions without failure. If, however, it is known that parts of a circuit will be submerged for loog periods, such as circuits around ashpits where ashes are wet down, we recommend Table EL Lead Sheathed A.V.C. Power Cable shown on page 28.
Rodcbestos A.V.C. 600 Volt Power Cable is also available up to 2,000,000 CM. For the same type ot cable for service voltages op to 5000 see Tables EM, F, G and H on pages 29, 50, 31 and 32,,
This cable is National Electrical Code Type AVA. listed by Underwriters' Laboratories.
TYPE AVA--TABLE E--600 VOLT SERVICE (NEMA Standard No. 39-54 Table 1)
Size Stranding
1,000,000CM 950,000 900,000 850,000 800,000 750,000 700,000 650,000 600,000 550,000 500,000 450,000 400,000 350,000 300,000 250,000 A.W.G.
0000 000 00 0 1 2
3 4
5 6 8 10 12 14 16 18
61/.1280 61/.I248 61/.1215 61 /. 1180 61/.1145
61/.1109 61 /. 1071 61/.1032 61/.0992 61/.0950 37/.1162 37/. 1103 37/.1040 37/.0973 37/.0900 37/.0822
19/.1055 19/.0940 19/.0837 19/.0745 19/.0664 7/.0974 7/.0867 7/.0772 7/.0688 7/.0612 7/.0486
7/.0385 7/.0305 7/.0242 7/.0193 7/.0151
Bare Diam.
Nominal
Nominal
Thickscm First
Thickneaa
Thickness Second
Felted
V.C.
Felted
Wall
Insert
Wall
Nominal Finished Diam.*
Annrox. Net
Weight
M ft.
Inches
Mils
Mils
Mil*
Inches Pounds
V)
1.152
30
40
40
u
N 1 465
3510
1.123
30
40
40
tn 1 435
3346
1.093
30
40
40
1.405
3182
1.062
30
40
40
< 1.375
3018
1.031
30
40
40
a 1-345
2854
.998 30
40
40
2 1.310
2689
.964 30
40
40
s 1.275
2524
.929 30
40
40
S 1.240
2359
.893 30 40 40
1.205
2193
.855 30 40 40
1.165
2027
.814 30
40
40
s 1 125
1860
.772 30 40 40
1.085
1692
.728 30
40
40
u 1 040
1525
.681 30 40 40
.995 1357
.630 30 40 40 c .940 1188
.575 30
40
40
Cs. .885
1017
.528 20
30
30 If) .780
839
.470
20
30
30 z .720
690
.418 20
30
30 u .670
571
-373 20 30 30
.625 476
-332 20 30 30
.585 371
.292 15 30 15
.505 287
.260
15
30
15
.470
238
.232 15 30 15
.445 198
.206 15 30 15
.420
166
.184 15 30 15
395 141
.146 15 30 15
.360 100
.116
15
30
15
.330
76
.092 15 30 15
.305 59
.073 15 30 15
.285 46
-058
15
30
15
.270
39
.045 15 30 15
.255 33
Shipping Lengths (Feet)
Coil* Reel*
500 500 500 1000 1000 1000 1000
500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500
1000 1000 ipoo 1000 1000 1000 1000 1000 1000 1000
* Finished diameters given above are average. A tolerance of pius or minus S% is necessary due to variations in process of manufacture. NEMA dielectric test voltages in kilovolts. 2.S for site* It to 8. 3.0 for 6 to */0 and A.O for 330.000 to 1,000.000 CM.
RBB 00333
ROCKBESTOS
THREE CONDUCTOR 600 VOLT A. V. C. POWER CABLE
for{ SAME USES AS TABLE "" WHERE MULTI-CONDUCTOR CABLE IS REQUIRED
113
4 1*
1
i. *Teio a lain eoMt conbucto*
*. rtirio asbcstos . CABLC TAR*
a. vorishco CAaatic 7. AtlCITOl *A(0
4. rcitto aiiiitos
, jure nueas
This construction consists of three Table E 600 Volt Power Cables minus their outer braids, cabled to gether with jute fillers, taped and covered with a heavy asbestos braid. Asbestos fillers, lead sheathing or armoring can be furnished on specification.
NOTE:--Multi-conductor power cables for higher rated voltages, with individual conductors made up like Tables EM, F, G and H (in the following pages) though not cataloged here, are available. Specifications of any particular size on request.
TABLE EC -- 600 VOLT SERVICE
Nominal
Nominsl
Approx.
Standard
Bare
Single
Finished
Net. Wt.
Shipping Lengths
Size
Stranding
Diam.
Diam.'
Diam.'
per M ft.
(Feet)
Inches
Inches
Inches
Pounds
Reels
500,000 CM 450,000 400,000 350,000 300,000 250,000 A.W.G.
0000 000 00 0 1 2
3 4 5 6 8 10 12
37/.1162 37/.1103 37/.1040 37/.0973 37/.0900 37/.0822
19/.1055 19/.0940 19/0837 19/.0745 19/.0664
7/.0974 7/.0867 7/.0772 7/.0688 7/.0612 7/.0486 7/.0385 7 / 0305
.814 .772 .728 .681 .630 .575
.528 .470 .418 .373 332 .292 .260 .232 .206 .184 .146 .116 .092
1.035 .995 .950 .905 .850 .795
.690 .630 .580 .535 .495 .415 .380 .355 .330 .305 .270 .240 .215
.350 2.265 2.170 2.070 1.955 1.835
1.610 1.480 1.370 1.275 1.190 1.015 .940
.885 .835 .780 .705 .640 585
6076 5527 4979 4426 3869 3298
2680 2189 1806 1486 1238
952 793 661 560 474 352 270 217
500 500 500 500 500 500
500 500 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
'Finished diameters liven above are average. A tolerance of plus or minus
is necessary due to variations in process of manufacture.
Dielectric test voltaies between conductors in kilovolts. 5.0 for sites IS to S. 6.0 for 6 to 4/0 and 8.0 for 250.000 to 500.000 CM.
Dielectric test voltages from conductor to ground in kilovolts. 2.5 for sixes 18 to 8. 2.0 for 6 to 4/0 and 4.0 for 250.000 to 500.000 CM.
RBB 00334
28
ROC K B E S T O S
600 VOLT LEAD SHEATHED A. V. a POWER CABLE
LIGHTING, CONTROL AND POWER CIRCUITS UNDER ANY CONDITION FROM COMPLETE SUBMERSION TO CONSTANT HIGH TEMPERATURES
ij
i
i. nuen plaid cosec* cohoucto*
s. piltcd aiurot
a. wmimio cas*ic
a. pcltio uiutm
i. uao cmcath
This wire is our standard A.V.C. construction except that a lead sheath has been substituted for the asbestos braid. The lead sheath does not affect the ability of the construction to withstand high temperatures, but does enable it to stand up successfully when completely and continually submerged.
This is the wire to use where a conduit run is exposed to.widely varying conditions throughout its length. Thus it is particularly suitable fhr power stations located on tidewater where certain ducts are sometimes flooded, but where another part of the same circuit is exposed to high temperature. Recommended also where conden
sation is especially heavy as in ashpits where it is the practice to wet down the ashes. Specify lengths desired, otherwise prices will be figured on standard shipping lengths. This cable is National Electrical Code Type AVL, listed by Underwriters' Laboratories.
NOTE: - Other power and control cables are also available with lead sheath, though not specifically cataloged.
TYPE AVL--TABLE EL--600 VOLT SERVICE (NEMA Standard No. 39-54 Table 2)
Size
Stranding
Bare Diam.
Inched
Nominal
Nominal
Thickness First
Thickness
Thickness Second
Felted
Y. C
Felted
Lead
Wall
Insert
Wall Thickness
... i -
--
--
Mils
Mils
Mils
Inches
Nominal Finished
Diarn.* ----
Inches
Net Weight
per
M__ft.
Pounds
Shipping Lengths
_(Feet)
Reels
1,000,000 CM 61/.1280 1.152
30
40
40
6/64
1.560
5613
500
950,000
61/.1248 1.123
30
40
40
6/64
1.535
5407
500
900,000
61/.12I5 1.093
30
40
40
6/64
1.505
5201
500
850,000
61/.1180 1.062
30
40
40
6/64
1.470
5042
500
800,000
61/.1145 1.031
30
40
40
6/64
1.440
4783
500
750,000
61/.U09
.998
30
40
40
6/64
1.410
4570
500
700,000
61/.107I
.964
30
40
40
6/64
1.375
4356
500
650,000
61/.1032
-929
30
40
40
6/64
1.340
4140
500
600,000
61/.0992
893
30
40
40
6/64
1.305
3923
500
550,000
61/.0950
.855
30
40
40
6/64
1.265
3786
500
500,000
37/.1162
.814
30
40
40
5/64
1.190
3161
500
450,000
37/.U03
.772
30
40
40
5/64
1.150
2944
500
400,000
37/.1040
.728
30
40
40
5/64
1.105
2724
500
350,000
P/.0973
.681
30
40
40
5/64
1.060
2500
500
300,000
37/.0900
.630
30
40
40
5/64
1.010
2269
500
250.000
37/.0822
.575
30
40
40
5/64
.955 2033
500
A.W.G.
0000
I9/.1055
.528
20
30
30 4/64 .815 1516 1000
000
19/.0940
.470
20
30
30 4/64 .755 1313 1000
00
19/.0837
.418
20
30
30
4/64
.705 1144
1000
0 1
19/.0745 19/.0664
.373 .332
20 20
30 30
30
4/64
.660
1005
1000
30 4/64 .620 890 1000
2
7/.0974
.292
15
30
30
4/64
.570
774
1000
3 4
7/.0867
.260
15
30
30
3/64
.505
563
1000
7/.0772
.232
15
30
30 3/64 .480 504 1000
5
7/.0688
.206
15
30
30
3/64
.450
454
1000
6
7/.0612
.184
15
30
30 3/64 .430 412 1000
8
7/.0486
.146
15
30
30 3/64 .390 348 1000
10
7/.0385
.116
15
30 30 3/64 .360 301 1000
12**
7/.03O5
.092
15
30
30
3/64
.340
267
1000
14**
7/.0242
.073
15
30
30
3/64
.320
243
1000
16**
7/.0193
.058
15
30
30 3/64 .305 224 1000
18**
7/.0151
.045
15
30
30
3/64
.290
209
1000
dlMnm.?*lvtn *bove *re *VCT1e. A toltrance of plus or minui 5% it necessary due to variation* in process of manufacture. *itet Mo. 12 A.W.G. end smaller can be supplied with 2/M* lead tbesth. NBMA dielectric teat voltage for all sites l.S kilovolt* for five minutes on a full reel.
RBB 00335
ROCKBESTOS
1000 VOLT A.V.C. POWER CABLE
GENERAL POWER WIRING IN BOILER ROOMS, POWER PLANTS, STEEL MILLS AND INDUSTRIAL PLANTS
29
t I4
)
1. (TMNOtO PLAIN COPPtR CONBUCTO*
t. FCLTCO *0tSTOS
J. VASNISHCB CAMSSIC
4. FtLTtD ASSCSTOS
S. ASatSTOX a*AIB
This.cable is recommended for the same general applications as Rockbestos 600 Volt A.V.C. Power Cable, Table E, except that it is designed to operate at 1000 volts or less. Lead sheathed ot armored if desired. Also available in multi-conductor construction. Specification for any given size on request.
TABLE EM -- 1000 VOLT SERVICE (NEMA Standard No. 39-54 Table 3)
Nominal
Nomina)
AoDrox.
Standard
Size
Stranding
Bare Diam.
Thickness
First Felted
Thickness V. C
Thickness Second Felted
Wall
Insert
Wall
Nominal Finished Diam.*
Net Weight
per M ft.
Shipping Lengths
(Feet)
Inched
Mils
Mils
Mils
Inches Pounds Coils Reels
1,000,000 CM 61/.1280
950,000
61/.1248
1.152 1.123
30 30
45 45
40 40
Cfi UN
1.475 1.445
3521 3354
900,000
61/.1215 1.093
30
45
40 (A 1.415 3187
850.000
6l /.1180 1.062
30
45
40
1.385
3020
800,000
61/. 1145 1.031
30
45
40 < 1.355 2853
750,000
61 /. 1109
.998
30
45
40
ce 1.320
2687
700,000
61/.1071
.964
30
45
40
it. 1.285
2521
650,000
61/.1032
.929
30
45
40
1.250
2355
600,000
61/.0992
.893
30
45
40 s 1.215 2189
550,000
61/.0950
.855
30
45
40
1.175
2023
500,000
37/.1162
.814
30
45
40
1.135
1857
450.000
37/.1103
.772
30
45
40 2 1.095 1691
400,000
37/. 1040
.728
30
45
40
1.050
1525
350,000
37/.0973
.681
30
45
40
1.005
1359
300.000
37/.0900
.630
30
45
40 .950 1193
250,000
37/.0822
.575
30
45
40 e .895 1024
A.W.G.
500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500
0000
19/.1055
.528
20
45
30
.810 857
lObO
000
19/.0940
.470
20
45
30 Hi .750
708
00
19/.0837
.418
20
45
30 z .700
588
1000 1000
0
19/.0745
373
20
45
30
.655 491
1000
1
19/.0664
.332
20
45
30 s .615
413
2
7/.0974
.292
15
45
15 H .535
299
1000 1000
3
7/.0867
.260
15
45
15
.500 250
1000
4
7/.0772
.232
15
45
15
.475 209
1000
5
7/.0688
.206
15
45
15
.450 176
1000
6
7/.0612
.184
15
45
15
.425 151 500 1000
8
7/.0486
.146
15
45
15
.390 109 500
10
7/.0385
.116
15
45
15
.360 84 500
12
7/.0305
.092
15
45
15
14
7/.0242
.073
15
45
15
335 67 1000 .315 54 1000
Finished diameters given above are average. A tolerance of plus or minus iCr is necessary due to variations in process of manufacture. NEMA dielectric test voltages in kilovolts. 3.5 for sires 14 to t and 4.5 for 6 to 1.000,000 CM.
RBB 00336
30
ROCKBESTOS
2000 VOLT A*V.C. POWER CABLE
GENERAL POWER WIRING IN BOILER ROOMS, POWER PLANTS, STEEL MILLS AND INDUSTRIAL PLANTS
)
1S I. JTMKOtO PLAIN COPPCA CONOWCTOA
S t. PELTED ASSESTOS
3. VAANISNEO CANMIC
s 4. PCLTEO ASSESTOS
S AS.SEST0S MAID
This cable is recommended for the same general applications as Rockbestos 600 Volt A.V.C. Power Cable, Table E, except that it is designed to operate at 2000 volts or less. Lead sheathed or armored if desired. Also available in multi-conductor construction. Specification for any given size on request.
Size Stranding
1,000,000 CM 900,000 800,000 750,000 700,000 650,000 600,000 550,000 500,000 450,000 400,000 350,000 300,000 250,000 A.W.G. 0000 000
00 0 1
2
3 4 5 6 8 10 12 14
61/.1280 61/.1215 61/.1145 61/.1109 61/.1071 61/.1032 61/.0992 61/.0950 37/.1162 37/.1103 37/.1040 37/.0973 37/.0900 37/.0822
19/.1055 19/.0940 19/.0837 19/.0745 19/.0664 7/.0974 7/.0867 7/.0772 7/.0688 7/.0612 7/.0486 7/.0385 7/.O305 7/.0242
TABLE F -- 2000 VOLT SERVICE (NEMA Standard No. 39-54 Table 4)
Bare Diam.
Nominal Thickness
First Felted
Nominal
Thickness V. c.
Nominal
Thickness Second Felted
Wall
Insert
Wall
Inches
Mils
Mils
Mils
Nominal Finished Diam.*
Approx. Net
Weight per
M ft.
Inches Pounds
Star dard Shi] ping Let gths
(F eet)
Coils Reels
1.152
30
60
40 tr. 1.505 3558
1.093
30
60
40
1.445
3230
1.031 ' 30 60 40
1.385
2907
.998 30 60 40
1.350
2738
.964 30 60 40
1.315
2569
E.929 30 60 40 CS 1.280 2403
.893 30
60 40
1.245
2236
.855 30 60 40
1.205
2066
.814 30 60 40 1.165 1897
.772 30 60 40
1.125
1728
.728 30 60 40
1.080
1564
.681 30 60 40 C 1.035 1390
.630 30 .575 30
60 60
40 40
-- t
.980 .925
1225 1060
500 500 500 500 500 500
500 500 500 500 500 500 500 500
.528 20
60
30 .840
878
1000
.470 20 .418 20
60 60
30 30
la.
.780 .730
715 594
1000 1000
.373 20
60
30 Cft .685
492
1000
.332 .292
20 15
60 60
30 25
z *
.645 .585
412 324
1000 1000
.260 15
60
25 S .550
269
1000
.232 15
60 25
.525 233
1000
.206
15
60
25
.500 197
1000
.184 15 60 25
.475 172
1000
.146 15
60 25
.440
130
1000
.116 15 60 25
.410 104
1000
.092 15 60 25
.385 85 500 1000
.073 15
60 25
.365 70 500 1000
* MiAeVl.""t*r# 8iV*n. *bovt ,re *ver*8*- A ferine* of plus or minus S% is necessary due to variations in process of manufacture. NEMA dielectric test voltages in kilovolts. 4.5 for sizes 14 to 8, S.O lot 6 and 5. 5.5 for 4 to 2 and 6.0 for 1 to 1.000.000 CM.
RBB 00337
ROCKBESTOS
3000 VOLT A.V*C. POWER CABLE
(
for\ 1
GENERAL POWER WIRING IN
BOILER ROOMS, POWER PLANTS, STEEL MILLS AND INDUSTRIAL PLANTS
31
IZ I. STBtNOtS PLA1M COPPCR COHOUCTO*
2. FtlTCO OtEITOt
2. VAKISE0 CAHOtC
ritrce atattros
AtStSTOS a**IO
This cable is recommended for the same general applications as Rodcbestos 600 Volt A.V.C. Power Cable, Table E, except that it is designed to operate at 3000 volts or less. Lead sheathed or armored if desired. Also available in multi-conductor construction. Specification for any given size on request.
TABLE G -- 3000 VOLT SERVICE (NEMA Standard No. 39-54 Table 5)
Size
Stranding
Bare Diam.
Nominal Nominal Nominal
Thickness First Felted
Thickness V. C
Thickness Second Felted
Wall
Insert
Wall
Nominal Finished Diam.*
Approx.
Net Weight
per M Ft.
Standard Shipping Lengths
(Feet)
Inches Mils Mils Mils
Inches
Pounds
Reels
1,000,000 CM 61/.1280
1.152
30
90
40
1.565.
3635
500
900,000
61/.1215
1.093
30
90
40 N 1.505
3302
500
800,000
61/.1145
1.031
30
90
40 <r. 1.445
2969
500
750,000
61/.1109
.998
30
90
40 2 1.410
2800
700,000
61/.1071
.964
30
90
40 < 1.375
2631
500 500
650,000
61/.1032
.929
30
90
40 1.340
2457
600,000
61/.0992
.893
30
90
40 3. 1.305
2293
500 500
550,000
61/.0950
.855
30
90
40 irt 1.265
2119
500
500,000
37/.1162
.814
30
90
40 5 1.225
1955
500
450,000
37/. 1103
.772
30
90
40 o 1.185
1786
500
400,000 350,000
37/.1040 37/.0973
.728 .681
30 30
90
40 oi 1.140
1612
90 40
1.095
1443
500 500
300,000
37/.0900
.630
30
90
40
1.040
1269
500
250,000 A.W.G.
37/.0822
.575
30
90
40
(d
H
.985
1094
500
0000
19/. 105 5
.528
20
90
30 .900
920 1000
000 00
19/.0940 19/.0837
.470 .418
20 20
90 90
30
u. O
.840
30 V} .790
766 1000 642 1000
0
19/.0745
.373
20
90
30 Ui .745
543 1000
1
19/.0664
.332
20
90
30
.705
459 1000
2
7/.0974
.292
15
90
25 w .645
383 1000
3
7/.0867
.260
15
90
25 = .610
331 1000
4
7/.0772
.232
15
90 25 b .585
260 1000
5
7/.0688
.206
15
90
25
.560
225 1000
6
7/.0612
.184
15
90
25
.535 195 1000
S
7/.0486
.146
15
90
25
.500
155 1000
10
7/.0385
.116
15
90
25
.470
125 100C
12
7/.0305
.092
15
90
25
.445 105 1000
14
7/.0242
.073
15
90
25
.425 90 1000
Finished diameters given above are average. A tolerance of plus or minus S% is necessary due to variations in process of manufacture. NEMA dielectric test voltages in kilovolts, 7.0 for sizes 14 to 8, 7.S for 6 and J, 8.0 for 4 to 2. 8.S for 1 to 4/0 and 9.0 for 250.000 to 1.000.000 CM.
RBB 00338
32
ROCKBESTOS
5000 VOLT A.V.C. POWER CABLE
GENERAL POWER WIRING IN
for f BOILER ROOMS, POWER PLANTS, l STEEL MILLS, INDUSTRIAL PLANTS, ETC.
1. *TN010 PLAIN COPPC* CONOUCTOA
2. PCLTCO ASSHTOS
2. VAPNUMIO CAMAIC
4. PCLTIO ASSrSTOS
. ASBtSTOS aID
This cable is recommended for the same general applications as Rockbestos 600 Volt A.V.C. Power Cable, Table E, except that it is designed to operate at 5000 volts or less. Lead sheathed or armored if desired. Also available in multi-conductor construction. Specification for any given size on request.
TABLE H -- 5000 VOLT SERVICE (NEMA Standard No. 59-54 Table 6)
Nomina! Nominal Nominal
Approx. Standard
Size
Stranding
Bare Diam.
Thickness First
Thickness
Thickness Second
Felted
V. C.
Felted
Wall
Insert
Wall
Nominal Finished Dtam.*
Net Weight
per M Ft.
Shipping Lengths (Feet)
Inches Mils Mils Mils
Inches
Pounds
Reels
1,000,000 CM 61/.1280
1.152
30
120
40
tn
id
1.625
3721
900,000
61/. 1215
1.093
30
120
40 N 1.565
3379
500 500
800,000
61/.1145
1.031
30 120 40
1.505
3040
500
750,000
61/.1109
.998
30
120
40 2 1.470
2876
500
700,000
61/.1071
.964
30
120
40
1.435
2701
500
650,000 600,000
61/.1032 61/.0992
.929 .893
30 30
120 120
40 40
u.
1.400 1.365
2532 2362
500 500
550,000
61/.0950
.855
30 120
40 M 1.325
2190
500
500,000
37/.1162
.814
30 120
40 6 1.285
2018
500
450,000
37/.U03
.772
30
120
40 O 1.245
1844
500
400,000 350,000
37/.1040 37/.0973
.728 .681
30 30
120 120
40 40
3as
1.200 1.155
1674 1500
500 500
300,000 250,000 A.W.G.
37/.0900
.630
30
120
40 C 1.100
1324
37/.0822
.575
30 120
40
id HS
1.045
1153
500 500
0000
19/.1055
.528
20
120
30 .960
967 1000
000
19/.0940
.470
20 120 30 0 .900
812 1000
00
19/.0837
.418
20
120
30 C/5 .850
687 1000
0 1
19/.0745 19/.0664
.373 .332
20 20
120 120
30 30
u z
.805 .765
582 1000 497 1000
2
7/.0974
.292
15
120
25 V .705
402 1000
3 4
7/.0867
.260
15
120
25 5 .670
7/.0772
.232
15
120
25
.645
363 1000 319 1000
5
7/.0688
.206
15
120
25
.620
285 1000
6
7/.0612
.184
15
120
25
8
7/.0486
.146
15
120
25
10
7/.0385
.116
15
120
25
12
7A0305
.092
15
120
25
14
7/.0242
.073
15
120
25
.595 .560 .530 .505 .485
251 1000 182 1000 152 1000 132 1000 117 1000
Finished diameters given above are average. A tolerance of plus or minus $% is necessary due to variations in process of manufacture. NEMA dielectric test voltage >2.0 kilovolts on all sizes.
rBB 00339
ROCKBESTOS
600 VOLT A.V.C. MOTOR LEAD and APPARATUS CABLE
J COIL CONNECTIONS, STEEL MILL MOTORS, TRANSFORMER LEADS,
JOT \ ELECTRIC LOCOMOTIVES AND SUBWAY CARS
9
33
I 2 94
t
I. FLESISLt TIMID COWS COkOUCTO*
t. FILTtD mtITOJ
J. VASNISKCD CAMIIIC
4. FCLTtD MIU'Di
5. ASelSIOS MMO
Rockbestos A.V.C. Motor Lead and Apparatus Cable was developed to meet a demand for a cable
capable of standing up without failure under severe heat and fire hazard conditions, as encountered in steel
mills, boiler houses, electrified railway equipment, subway cars, etc.
.
This cable is positively fireproof -- it will not burn under any condition, consequently fire cannot travel along its insulation. It withstands the attack of heat without drying out or becoming brittle and it remains permanently flexible. Can be installed the same as other cables and will not rot, bloom or swell as it is practically unaffected by fumes, vapors, oils or greases. Also supplied with extra flexible plain copper con ductor, stranded as shown in Table W on page 52. This cable is National Electrical Code Type AVA. NOTE: Although this is the cable generally recommended for motor leads, Rockbestos Flexible All-Asbestos Apparatus Cable is sometimes used where only high* temperatures ate encountered. See page 51.
TYPE AVA --TABLE L--600 VOLT SERVICE (NEMA Standard No. 39-54 Table 55)
Nominal
Nominal
.
Approx.
Standard
Sice
Stranding
Bare
Thickness First Felted
Thickness V. C.
Thickness Second Felted
Nominal Finished
Net Weight
Shipping Lengths
Tinned
Diam.
Vail
Insert
Wolt
Diam.* M ft.
(Feet)
Inches
Mils
MtU
Mils
Inches Pound* Coils Reel*
1,000,000 CM 950,000 900,000 850,000 800,000 750,000 700,000 650,000 600,000 550,000 500,000 450,000 400,000 350,000 300,000 250,000
A.W.G.
427/.0480 427'0472 427/.0453 427/.0446 427/.0427 427/.0420
427/.0403 427 '.0390 427/.0380
427/.0359 427/.0342
427/.0325 427/.0306 427/.0286
427/.0265 427/.0242
1.295 1.274 1.222 1.204
1.153 1.134 1.088
1.053 1.027
.969 .923 .878 .826 .772 .716
.653
20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
40 40
1.585
3628
40 40
1.565
3533
40 40
40 40
X
a
1.515 1.495
3294 3199
40
40
X 1.445
2961
40 40
1.425
2794
40
40
< 1.380
2622
40
40
a 1.345
2428
40
40
c 1.320
2289
40 40
1.260
2087
40 40
40 40
lA 1.215 e> 1.170
1935 1764
40
40
a 1.120
1586
40
40
< 1.065
1404
40
40
C 1 010
1233
40 40 u. .945 1055
500 500 500 500 500 500 500
500 500 500 500 500 500 500
500 500
0000 000 00 0 1
259/.0286 259/.0255 259/.0227 259/.0202 259/.0180
.600 -536 .477
.424 .378
15 15 15 15 15
30
30
X X
.840
875
30
30 v .775
721
30
30 sg .720
592
30 30
.665 492
30 30 S .620 415
1000 1000 1000 1000 1000
2
133/.0224
.336
10
30 15
.540
300
1000
3
133/.0199
.299
10
30 15
.500
248
1000
4
133/.0177
.266
10
30 15
.470
210
1000
5
133/.0158
.237
10
30 15
.440 173
1000
6
133/.0141
.212
10
30 15
.415 147 500 1000
8
133/.0112
.168
10
30 15
.370 104 500
10 105/.010 .120 10 12 65/.010 .095 10 14 41/.010 .075 10
30 15 30 15 30 15
.320 .295 .275
76 500 59 1000 45 1000
16 26/.010 .059 10 50 15
.260 38 1000
18 16/010 .045 10 50 15
.245 32 1000
* diameters given above are average. A tolerance of plus or minus 5% is necessary due to variations in process of manufacture. NEMA dielectric test volugts in kilovolts. 2.S for sites 18 to 8. J.O for 6 to VO and 4.0 for 2SO.OOO to 1.000.000 CM.
RBB 00340
\ 34
ROCKBESTOS
600 VOLT A.V.C. MINING CABLE for { ALL INTERNAL CIRCUITS OF
ELECTRIFIED MINING EQUIPMENT
I. riHItlt TINNED COFFC* COMDUCTO*
13
4
*. FCITtO ASICSTOf
S
3. VARNISHES CAHIA1C
4. FCITEO AfltHOS
t. ASSCSTOS MAIO
This construction is simply our standard Table L, A.V.C. Motor Lead and Apparatus Cable with dia meters altered slightly so as to accurately fit the standardized bushing sizes of electrified mining equipment.
It has been used for several years by manufacturers of mine locomotives, loaders and coal cutters for
motor resistor and controller connections. It is also in constant use in the maintenance operations of hun
dreds of mines.
.
Mining customers should definitely specify Table ML when requisitioning cable for all internal circuits of electrified mining equipment.
NOTE: Rockbestos A.V.C. Mining Cable is not recommended or intended for use as drag or reel cable.
TABLE ML -- 600 VOLT SERVICE
Sice
Stranding Tinned
Bare Diam.
Nominal
Nominal
Approx.
Thickness Nominal Thickness First Thickness Second
Max,
Net Weight
Felted
V. C.
Felted Finished per
Wall
Insert
Wall Diam.* M Ft.
Standard Shipping Lengths
(Feet)
Inches Mils Mils Mils Inches Pounds Coils Reels
500,000 CM 427,61x7 (.0342) .923
20
40
40 1.274 1935
500
450,000
427, 61x7 (.0325) .878
20
40
40 1.226 1764
500
400,000
427, 61x7 (.0306) .826
20
40
40 1.172 1586
500
350,000
427, 61x7 (.0286) .772
20
40
40 1.115 1404
500
300,000
427,61x7 (.0265) .716
20
40
40 1.056 1233
500
250,000
427, 61x7 (.0242) .653
20
40
40 .988 1055
500
A.W.G.
0000
259, 37x7 (.0286) .600
15
40
15 .849 832
1000
000 259, 37x7 (.0255) .536 15
40
15 .779 682
1000
00 259, 37x7 (.0227) .477 15
40
15
.716
553
1000
0 259, 37x7 (.0202) .424 15
1
259, 37x7 (.0180) .378
15
40 40
15 .669 455 15 .620 377
1000 1000
2
133, 19x7 (.0224) .336
10
40
10
.546
300
1000
3
133,19x7 (.0199) .299
10
40
4
133, 19x7 (.0177) .266
10
40
5
133,19x7 (.0158) .237
10
40
6 133, 19x7 (.0141) .212 10
40
8
133, 19x7 (.0112) .168
10
40
10
105/.010
.120
10
40
12
65/.010
.095
10
40
14
41/.010
.075
10
40
10 .506 248
1000
10 .473 203
1000
10 .428 160
1000
10 .405 137 500 1000
10 .359 98 500
10 .313 71 500
10 .294 54 1000
10 273 43 1000
* Minimum diameter 92'/,% of maximum diameter.
RBB 00341
ROCKBESTOS
FIREPROOF ELEVATOR CONTROL CABLE
35
I1
I. Finnic Slid CORE S. FELTED ASRESTOS
J
45
?
t
1. COTTON SERVING
J. STRANOEO FIAIN COFFER CONDUCTOR
t. RATON SRAIB
T. ASRCSTOS FILLERS
4, CARLE TAPE
4. SPECIAL RURSCR ASRESTOS RRAIO
Enough eierstor fires hive occurred to thn there is i growing conviction among elevator manufacturers, building mans* gers and architects that a fireproof elevator control or travelling cable is a necessity. In addition to being fireproof, it is important in this application that the cable shall be flexible and highly resistant to the deteriorating effect of almost constant flexing, heat and age.
After considerable experimenting with various constructions Rockbestos developed an elevator cable the individual con ductors of which are insulated with a combination of latex and felted asbestos, surmounted by a polarized rayon braid. The individual conductors are cabled around a heavily protected flexible steel core wire with the proper lay to obtain the maximum degree of flexibility. The cable assembly is then covered with a lapped, moisture-resisting cable tape and finished with a tough, abrasion-resisting asbestos yarn braid, processed with special moisture-resisting and flameproof compounds to increase its inherent fireproof characteristics. The flexible stranded steel core running through the center of the cabling is the shortest member of the assembly and thus takes the weight of the cable plus any tension to which it may be subjected. It is recommended regard less of the length of the cable required but cable can be made up without the steel core if it is so ordered. The braids of the individual conductors are polarized according to the N.E.M.A. control cable color code unless otherwise specified.
TABLE VK
Number of
Conductors
Nominal Finished Diameter* Inches
No. 16 A.W.G.
No. 18 A.W.G.
Approx. Net Weight per M ft. Pounds
No. 16
No. 18
Standard Shipping Lengths
(Feet) Reels
2 .640 .610 169
3 .640 .610 189
4 .640 .610 209
6 .640 .610 249
8 .760 .730 332
10 .860 .780 391
12 .980 .880 434
14 1.100 .980 513
16
1.130
1.070
593
18
1.130
1.070
635
20
1.230
1.170
736
30
1.330
1.270
1015
156
171
186 In 226
288 Lengths 330
383 426
as
503 535 Specified
625
853
* Finished diameters given above are average. A tolerance of plus or minus S<7( is necessary due to variations in process of manufacture.
I. STRANDED PLAIN COPPER CONDUCTOR
a. SPECIAL RUBBER
5. FCLTEO ASBtSTOS
4. RATON RRAIO
S. ASBESTOS FILLERS
t. ASRESTOS RRAIO
This two conductor Rockbestos Elevator Lighting Cable is made up with individual conductors insulated the same as the conductors of the control cable, then cabled with fillers to make a round assembly and covered with a moisture-resisting and flameproof asbestos braid. Since the cable is comparatively light no steel supporting core is required. Size No. 14 AWG is usually ample for elevator lighting requirements.
TABLE VT
Conductors
No. 14 A.W.G.
Approx. Net Weight per M ft. Pounds
Standard Shipping Lengths
(Feet) Reels
2 .490
111 In Lengths as Specified
* Finished diameters given above are average. -A tolerance of plus or minus S% is necessary due to variations in process of manufacture.
RBB 00342
36
ROCKBESTOS
600 VOLT A.V.C.- CONTROL CABLE
' BOILER ROOMS, POWER STATIONS, KILN ROOMS AND OTHER LOCATIONS WHERE CONTROL OR SIGNAL
_ WIRING IS EXPOSED TO HEAT
I1
>4
I
7
1. TIXNIO C0**t* COHBUCTO*
l. FlLTte AIStfTOS
J. VARMIIHCO CAHINIC
4. FtLTCD AtSCtTO*
Clf TAFt
7. ASItSTOS ItAIB
coio* eooto cotton (raids
APPLICATIONS
Rockbestos Control Cable is designed for use under conditions too severe for control cables with other types of insulation. It is especially recommended for boiler rooms, kiln rooms and steel mills as a substitute for control cable with other insulations which deteriorate rapidly when exposed to the high temperatures prevailing in these places. In addition, it will operate successfully under conditions of oil, grease and corrosive fumes. It is suitable for installation either open or in conduit.
CONSTRUCTION
The insulation on the individual conductors is Rockbestos A.V.C. construction, as illustrated. The varnished cambric is sealed between the dense, impregnated walls of felted asbestos and the entire insulation is permanently flexible.
Moistureproof tape is wrapped over the cabling and this is covered with a tough jacket of braided asbestos yarn finished with special flame, heat and moisture resisting insulating compounds. The special tape wrapping adds to the moisture resisting properties of the cable and prevents the braid-finishing compounds from going through and soiling the colored cotton braids on the indi vidual conductors.
CONDUCTORS: Number and Size
Standard standings are 19/22 (No. 9 A.W.G.) and 19 25 (No. 12 A.W.G.) but any strand ing can be furnished to order. Can be made in these standings with any required number of con ductors.
CODING
Individual wires are cotton braided in colors according to the N.E.M.A. standard color code for multi-conductor cable, which is reproduced below. Special color combinations will be supplied if desired.
Conductors
1 2 * 4 5 6
Base Color
Black White Red Green Orange Blue
Conductors
7 8 9 10 11 12 13
Base Color
White Red Green Orange Blue Black Red
Tracer
Black
1!
"
..
White "
Conductors
14
15
1 16
17
, *8 , 19
Base Colot
Green Blue Black White Orange Blue
Tracer
White
Red * "
FINISH
The standard finish of the outer braided asbestos jacke is black -- flame, heat and moisture resisting. A polished white finish may be supplied, however, impregnated with either flame and heat resisting, or flame, heat and moisture resisting compounds. Specify preference.
LEAD OR ARMOR COVERING
Rockbestos A.V.C. Control Cable can be supplied with lead sheath or armored covering to customer's specifications. Lead sheathing is applied directly over the tape in place of the asbestos braid. Armor can be applied either with or without lead sheath as specified
See page 37 for specifications
rBB 00343
ROCKBESTOS
Specifications for A*V.C CONTROL CABLE
Nominal Sizes 9 and 12 A.W.G.
1 to 19 Conductors
(See page 36 tor general information)
J7
CONSTRUCTION
Standard conductor sizes are A.W.G. No 9 19/22 and No. 12 19/25 tinned copper, in sulated with a *10 mil wall of felted and impregnated asbestos, 25 mil wall varnished cambric insert, another 15 mil wall of felted asbestos and a cotton braid colored according to the N.E.M.A. Control Cable Color Code for multi-conductor cables, shown on page 36. The individual conductors are then cabled with jute fillers where necessary, a layer of cable tape is applied and finally an asbestos braid finished with black flameproof and moisture resisting compound.
The diameters of the single conductors, taken over the cotton braid, are:
No. 9 --.265" No. 12 --.230"
Number of
Conductors
**1
***2
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
TABLE MD (NEMA Standard No. 39-54 Table 16)
A.W.G. No. 12 - 19/25
Nominal Finished Diameter*
Approx. Net Weight per M feet
Standard Shipping Lengths
(Feet)
Inches
.290 .570 .605 .660 .735 .795 .795 .870 .935 1.020 1.055 1.055 1.110 1.110 1.175 1.175 1.245 1.245 1.245
Pounds
56 176 204 249 281 333 343 395 441 468 516 539 592 616 675 699 748 772 795
Reels
1000 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500
TABLE MT (NEMA Standard No. 39-54 Table 17)
A.W.G. No. 9 19/22
Nominal Finished Diameter*
Approx. Net Weight per M feet
Standard Shipping Lengths
(Feet)
Inches
.330 .645 .685 .755 .830 .905 .905 .990 1.070 1.170 1.205 1.205 1.275 1.275 1.350 1.350 1.430 1.430 1.430
Pounds
81 233 288 358 412 491 516 555 670 715 790 832 915 948 1047 1100 1168 1210 1253
Reels
1000 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500
Finished diameters given above are average. A tolerance of plus or minus S% i* necessary due to variations in process of manufacture. *' Single conductor has no cotton braid. Asbestos braid is applied directly over insulation *** Can be furnished either parallel or twisted. Specify which.
NEMA dielectric test voltage on single conductors. 2.5 kilovolts.
RBB 00344
}8
..... = ROCKBESTOS
-
600 VOLT SOLID
A.V.C. SWITCHBOARD WIRE
1*
1. SOUP TIKNCD COfSM CONDUCTOR
3
i. VA4KHHIB CAMiaiC
4 ). FCLTCB ASStSIOS
A. FLANCRSOOr COTTON (RAID
Switchboards which are wired with rubber insulated or slow burning wires are, in the opinion of many engineers, fire hazards that should be eliminated. The use of Rockbestos Switchboard Wire is the cheapest kind of fire-insurance. It is guaranteed not to communicate fire even if it is exposed to contact with an electric arc.
Standard construction of this wire consists of a tinned copper conductor, a wall of varnished cambric, a heavy wall of felted asbestos insulation- impregnated with flame and moisture resisting insulating compounds, and a closely woven cotton braid finished with flame resisting compound. This construction complies with the N.E.M.A. Small Wiring for Switchboards Standard.
There are several distinct advantages in using Rockbestos Switchboard Wire. It is absolutely fireproof. Regardless of the amount of flame applied to it, it cannot burn and will not transmit flame because of the fireproof wall of felted asbestos lying beneath the cotton braid. Low surface leakage when the wire is damp is another desirable characteristic of Rockbestos Switchboard Wire.
Fine appearance can be secured on the completed board because no matter how sharply Rock bestos Switchboard Wire is bent, it will not crack or break open. Even if a bend is made several times in the same place the braid will not crack. The reason for this unusual performance is the felted wall of asbestos which acts like a cushion and "gives" slightly when a sharp bend is made. For this reason, boards can be wired faster than with ordinary all-cambric switchboard wire which must be handled carefully if breaks are to be avoided. The braid, made of the best grades of selected cotton and impregnated with special finishing compounds, is burnished to a smooth finish, free of moisture and dust-collecting fibres or whiskers.
On switchboards installed in locations where the wiring is exposed to high temperatures we recommend the use of our Table C, A.V.C. Boiler Room Wire shown on page 25.
APPROVED
Rockbestos Switchboard Wire, N. E. Code Type AVB is listed by the Underwriters' Laboratories and is approved by Factory Mutual Laboratories, most switchboard manufacturers and many power companies.
BRAID COLORS Standard (stock) braid colors are gray and black. Red, yellow, blue, green, brown and white
braids in plain colors or striped patterns can be furnished on special order. Be sure to specify braid color desired on order. This also applies to Switchboard Cable, Hinge Cable and Bus Cable.
Size A.W.G.
0000 000 00 0 1 2 4 6 8 10 12 14 16 18
TYPE AVB--TABLE B--600 VOLT SERVICE (NEMA Standard No. 39-54 Table 12)
Bare Diam.
Nominal Thickness
V, C.
Nominal Thickness
Felted Wall
Nomina] Finished Diam.*
Approx.
Net Weight
per M Ft.
Star dard Shipping Lengths
(F eet)
Inches
Mils
Mils
Inches
Pounds
Coils
Reels
.460 .410 .365 325 .289 .258 .204 .162 .128 .102 .081 .064 .051 .040
40 40 40 40 40 40 40 40 30 30 30 30 30 30
40
.665
800
450
40
.615
650
500
40
.570
530
500
40
.530
435
500
40
.495
365
1000
40
.465
300
1000
40
.410
210
1000
40
.370
155
1000
20 .270
82
500
1000
20 .245
59
500
1500
20 .225
44
500
2000
20 .205
34
500
2500
20 .195
27
1000
2500
20 .180
23
1000
3000
* Finished diameters given above are average A tolerance of plus or minus S% is necessary due to variations in process of manufactureNEMA dielectric test voltages in kilovolts. 3.0 for sixes 18 to 8 and 4.0 (or 6 to 4/0.
RBB 00345
f
ROCKBESTOS
39
600 VOLT STRANDED A. V. C. SWITCHBOARD CABLE
This wire is identical in all characteristics to our Table B, A.V.C. Switchboard Wire, except that it has a coarse stranded conductor. Many engineers are of the opinion that the possibility of a broken conductor, due to a nick which may occur when skinning, is far less with a stranded than with a solid conductor.
APPROVED Rockbestos A.V.C. Switch'xard Cable, National Electrical Code Type AVB, is listed by the Under
writers' Laboratories, and is approved by Factory Mutual Laboratories, most switchboard manufacturers and many power companies.
BRAID COLORS Standard (stock) braid colors are gray and black. Red, yellow, blue, green, brown and white
braids in plain colors or striped patterns can be furnished on special order. Be sure to specify braid color desired on order. This also applies to Switchboard Wire, Hinge Cable and Bus Cable.
TYPE AVB---TABLE BS--600 VOLT SERVICE (NEMA Standard No. 39-54 Table li)
Size A.W.G.
Stranding Tinned
Bare Diam.
Nominal Thickness
V. C.
Nominal Thickness
Felted Wall
Nominal Finished Diam.*
Approx. Net
Weight per
M Ft.
Stan dard Shipping Lengths
(FeO
Inches
Mils
Mils
Inches
Pounds
Coils
Reels
0000
19/.1055
.528
40
40 .735 835
500
000
19/.0940
.470
40
40 .675 675
500
00
19/.0837
.418
40
40 .625 555
500
0
19/.0745
.373
40
40
.580
460
500
1
19/.0664
.332
40
40 .540 380
1000
2
7/.0974
.292
40
40 .500 315
1000
3
7/.0867
.260
40
40 .465 263
1000
4
7/.0772
.232
40
40
.440
225
1000
6
7/.0612
.184
40
40 .390 163
1000
8
7/.0486
.146
30
20 .290
87
500
1000
10
7/.0385
.116
30
20 .260
63
500
1500
12
7/.0305
.092
30
20 .235
47
500
2000
14
7/.0242
.073
30
20 .215
36
500
2500
16
7/.0193
.058
30
20 .200
28
1000
2500
2018
7/.0151
.045
30
.185
23
1000
3000
Finished diameters given above are average. A tolerance of plus or minus S% is necessary due to variations in process of manufacture. NEMA dielectric test voltages in kilovolts. 3.0 for sires 18 to 8 and 4.0 for 6 to 4/0.
RBB 00346
40
ROCKBESTOS
600 VOLT FLEXIBLE A. V. C. SWITCHBOARD HINGE CABLE
for{ SWITCHBOARDS, PANELBOARDS AND ALSO FOR CONDUIT WIRING WHERE A SMALL O.D. IS REQUIRED
12
2
i. STSSHOIS TtKNtO COtftft COOUCTO*
1. flLltO UltlTOS
S
X. VMtMSKtS .*
*
4. fllTtO tUtllOi
X. H.MItF*OCr tOTtDX >IC
As a companion wire to Rockbestos Switchboard Wire, we offer Rockbestos Hinge Cable, a heat resisting and fireproof, extra flexible wire, developed and used primarily for hinge or jumper connections on swinging panels, connections to swinging synchronizing meters, lamps and the like. It is also used for conduit wiring where the larger diameters of Table: E and L cannot be accommodated.
Standard construction employs a flexible stranded, tinned copper conductor, insulated with a felted wall of asbestos, an insert of varnished cambric tape, another wall of felted asbestos, impregnated with flameproof and moisture resisting insulating compounds, and a flameproof cotton braid overall.
The diameter of Rockbestos Hinge Cable is about the same as that of Table B Switchboard Wire. The same black, gray and colored finish compounds that are used on Table B wire are also used on Hinge Cable, so that when they are used on the same board they match.
Showing application of Rockbestos Table BH 600 Volt Hinge Cable to swinging instrument panel on a switchboard.
APPROVED
Rockbestos A.V.C. Hinge Cable, National Electrical Code Type AVB, is listed by the Underwriters' Laboratories and is approved by Factory Mutual Laboratories, most switchboard manufacturers and many power companies.
BRAID COLORS
The standard braid finishes are gray and black, the same as for Switchboard Wire or Cable and Bus Cable. Red, yellow, blue, green, brown and white braids in plain colors or striped pat terns can be furnished on special order. Be sure to specify braid color desired on order.
TYPE AVB--TABLE BH--600 VOLT SERVICE (NEMA Standard No. 39-54 Table 13)
Sice A.W.G.
Stranding Tinned
Bare Diara.
Nominal
Thickness First Felted Wall
Nominal Thickness
V.C Insert
Nominal Thickness
Second Felted Wail
Nominal Finished Diant.*
Approx. Net
Weight per
M Ft.
Standard Shippin( Lengths
<F-et)
Inches
Mils
Mil*
Mils
Inches
Pounds
Coils
Reels
8
133/.0112
.168
10 105/.010 .120
12
65/.010
.095
14
41/.010
.075
16
26/.010
.059
18
16/.010
.045
10 10 10 10 10 10
25
15
.310
89
500
1000
25
15
.260
63
500
1500
25
15
.235
43
500
2000
25
15 .215 34
500
2500
25
15
.200
27
1000
2500
25
15
.185
22
1000
3000
Finished diameters given above are average. A tolerance of plus or minus 5% is necessary due to variations in process of manufacture. NEMA dielectric test voltage 2.5 kilovolts on *11 sizes.
RBB 00347
ROCKBESTOS
600 VOLT A.V.C. SWITCHBOARD BUS CABLE
41
i
1. STRANBtO ASAIM COPACB COMBUCTO*
**
I. PCLTCD A1SCSTOS
*. VAIMISXBB Classic
i
4. PCtTCB ASStSTOI
I. FLAMtSSOOF BOTTOM SAAIO
As Kockbestos A.V.C Switchboard Wire and A.V.C Hinge Cable have become more generally used by switchboard builders and power companies, requests have been received for insulated cable with a finish and characteristics matching these wires, to be used for bus work. For this purpose we offer Rockbestos A.V.C Switchboard Bus Cable, made to the same specifications as A.V.C Power Cable except that instead of a braided asbestos jacket it has a braided cotton jacket, finished in either standard gray or blade to match our Switchboard Wire and Cable or Hinge Cable. White or colored braids also avail able on spedal order. Colors same as Table B on page 38. The use of this family of switchboard wires makes unnecessary the painting of the completed wiring to insure a matching appearance.
. This cable is National Electrical Code Type AVB, listed by Undecwriters* Laboratories.
TYPE AVB--TABLE P--600 VQLT SERVICE (NEMA Standard No. 39-54 Table 10
Size
Stranding
Bare Diem.
Nominal Nominal Nominal
ThtekncM Thickness Thickness
First Felted
V.C.
Second Felted
Wall
Insert
Wall
Nominal Finished Diam.*
Approx. Net
Weight
mT,.
Standard Shipping Length
(Feet)
Indict
Mila
Mil.
Mila
Inches Pounds Coils
Reel*
1,000,000 CM 950,000 900,000 850,000 800,000 750,000 700,000 650,000 600,000 550,000 500,000 450,000 400,000 350,000 300,000 250,000 A.W.G. 0000 000 00 0 1 2 3 4 5 6 8 10 12 14 16 18
61/.1280 61/.1248 61/.1215 61/.1180 61/.1145 61/. 1109 61/.1071 61/.1032 61/.0992 61/.0950 37/.1162 37/.1103 37/.1040 37/.0973 37/.0900 37/.0822
19/.1055 19/.0940 19/-0837 19/.0745 19/.0664
7/.0974 7/.0867 7/.0772 7/.0688 7/.0612 7/.0486 7/.0385 7/.0305 7/.0242 7/.0193 7/.0151
1.152 1.123 1.093 1.062 1.031 .998 .964 .929
.893 .855 .814 .772 .728 .681 .630 .575
.528 .470 .418 .373 .332 .292 .260 .232 .206 .184 .146 .116 .092 .073 .058 .045
30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
20 20 20 20 20 15 15 15 15 15 15 15 15 15 15 15
40
40
1.435
3524
40
40
1.405
3357
40
40
1.375
3190
40
40
1.345
3023
40
40
1.315
2856
40
40
1.280
2695
40
40
1.245
2522
40
40
1.210
2355
40
40
1.175
2188
40
40
1.135
2021
40
40
1.095
1854
40
40
1.055
1687
40
40
1.010
1522
40
40
.965
1351
40
40
.910
1186
40
40
.855
1019
500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500
30
30
.735
820
loop
30
30
.675
670
1000
30
30
.625
555
1000
30
30
.580
455
1000
30
30
.540
350
1000
30
15
.460
284
1000
30
15
.425
234
1000
30
15
.395
194
1000
30
15
.370
163
1000
30
15
.345
136 500 1000
30 15 .310 98 500
30
15
.280
71 500
30 15 .255 55 1000
30 15 .235 43 1000
30 15 .220 36 1000
30 15 .205 30 1000
* Finished diameters given above are average. A tolerance of plus or minus $% is necessary due to variations in process of manufacture. NEMA dielectric test voltages in kilovolts, 2.5 for sizes 1* to . 3.0 for 6 to 4/0 and 4.0 for 250.000 to 1,000.000 CM.
RBB 00348
42
="' ROCKBESTOS
Wired for Insurance against Fires
RBB 00349
ROCKBESTOS
Typical Rockbestos Wired Boards
43
Rockbestos Switchboard Wire is uniform in -finish. When future expansion necessitates additional wiring on this board, it will exactly match the existing wiring.
kf*:
Beautiful wiring jobs can be done with Rockbestos Switchboard Wire.
Illustrating use of Rockbestos Hinge Cable.
RBB 00350
44
ROCKBESTOS
600 VOLT SOLID
National Electrical Code Type SNA
SWITCHBOARD WIRE
I2
J
4
I. fOUB TSMKCB COME* CO#UCTO
Z. SVMTNCTIC ICSIN
J. PCLTCP tIHITOt
4. rUP*0 COTTON 1**10
SYNTHETIC RESIN AND FELTED ASBESTOS INSULATION
This new Rodcbestos Switchboard Wire, insulated with a Seamless synthetic sheath, felted asbestos and a flameproof cotton
braid is resistant to beat,
oil, grease, corrosive fumes and moisture. It skins easily, takes right angle bends without
cracking, and is approved for applications in temperatures ranging up to 194F. The same insulation construction is also
available in Rodcbestos Type SNA Switchboard Cable with coarse stranded conductor shown on page 4$, and Rodcbestos
Type SNA Flexible Switchboard Hinge Cable with flexible stranded conductors shown on page 46.
TWO DIAMETERS
Made in two* diameters, "Small" (Table XB) for installations requiring the grouping of many wires of minimum size and
weight in limited space, or "Standard'* (Table XBO) in the same diameters as Rodcbestos A.V.C Switchboard Wire, Table
B shown on Page
to permit perfect matching with previous wiring and a snug fit in cleats, damps and fittings designed for
the larger diameter.
APPROVED This Wire is National Electrical Code Type SNA and is listed by the Underwriters' Laboratories.
BRAID COLORS
Standard braid colors are gray and black. Red, yellow, blue, green, brown and white braids in plain colors and striped pat terns can be furnished on special orders. Be sure to specify braid color, size, quantity, type name, and table letters on your order. This also applies to Rodcbestos Type SNA Switchboard Cable and Hinge Cable.
Sice A.W.C.
Bare Diam.
Inches
Nominal Thwkneaa Synthetic
Reein
Mils
Nominal Thickness
Felted Asbestos
Mila
Nominal Thickness
Cotton Braid
Mils
Nominal Finished Diam.*
Inches
Approx. Net
Weight perM ft.
Pounds
Standard Shipping Lengths
(Feet)
Coils
Reels
TYPE SNA--TABLE XB--SMALL DIAMETER-- (NEMA Standard, No. 39-54 Table 14A)
8
.128
22.5
20
17.5
.250
10
.102
22.5
20
15.0
.220
12
.081
22.5
20
15.0
.200
14
.064
22.5
20
15.0
.185
16
.051
22.5
20
15.0
.170
18
.040
22.5
20
15.0
.160
75 54 39 30 24 19
500 500 500 500 1000 1000
TYPE SNA--TABLE XBO--STANDARD DIAMETER--(Same diam. as our Table B. NEMA Table 12>
8
.128
22.5
27.5
20
.270
10
.102
22.5
27.5
20
.245
12
.081
22.5
27.5
20
.225
14
.064
22.5
27.5
20
.205
16
.051
22.5
27.5
20
.195
18
.040
22.5
27.5
20
.180
79 56 42 31 26
21
500 500 500 500 1000 1000
1000 1500 2000 2500 2500 3000
1000 1500 2000 2500 2500 3000
Finished diameters given above ait average. A tolerance oi plus or minus i% is necesaary due to variations in process of manufacture. NEMA dielectric test voltage 3.0 kilovolts on all sizes.
RBB 00351
= ROCKBESTOS =
600 VOLT STRANDED
National Electrical Code Type SNA
SWITCHBOARD CABLE
45
i*
*
I. STtANDCO TINNIO COFPt* COXDUCTO*
l. STNTHtTIC SHIN
}. KITIO AllUfOl
4. flAIIMOCF COTTOM SKID
SYNTHETIC RESIN AND FELTED ASBESTOS INSULATION
A new Rockbestos Switchboard Cable insulated exactly the same as Rockbestos Type SNA Switchboard Wire, on page 44, but put up with a coarse stranded conductor for those who prefer that type to a solid wire. The laminated insulation, consisting of a seamless synthetic sheath, felted asbestos and flameproof cotton brai4, skins easily, takes sharp bends without cracking, is resistant to heat, flame, oil, grease, corrosive fumes and moisture, and is approved for temperatures up to 194F. For matching solid and flexible conductor constructions see Rockbestos Type SNA Switchboard Wire shown on page 44 and Rockbestos Type SNA Flexible Hinge Cable shown on page 46.
TWO DIAMETERS
Available is two diameters. `'Small" (Table XBS) for applications necessitating the bunching of many wires in confined
spaces and where weight reduction is a factor. "Standard" (Table XBSO) in the same diameters as our. Rockbestos A.V.C.
Switchboard Cable, Table BS. shown on page 39, to permit matching up present wiring and proper fitting of cleats and clamps
designed for the larger diameter.
.
APPROVED This Cable is National Electrical Code Type SNA and is listed by the Underwriters* Laboratories.
BRAID COLORS
Standard braid colors are gray and black. Red, yellow, blue, green, brown and white braids in plain colors and striped pat terns can be furnished on special orders. Be sure to specify braid color, size, quantity, type name, and table letters on your order. This also applies to Rockbestos Type SNA Switchboard Wire and Hinge Cable.
Size A.W.C.
Stranding Tinned
Bare Diem.
Inches
Nominal Thickneas Synthetic
Reein
Nominal Thickness
Felted Asbestos
Nominal Thickness
Cotton Braid
Nominal Finished Diam.*
Mil*
Mils
Mils
Inches
Approx. Net
Weight per M ft.
Pounds
Standard Shipping Lengths
(Feet)
Coils
Reels
TYPE SNA--TABLE XBS--SMALL DIAMETER--(NEMA Standard, No. 39-54 Table 14)
8
7/.0486
.146
22.5
20
17.5
.270
79
500
10
7/.0385
.116
22.5
20
17.5
.240
56
500
12 7/.03Q5 .092
22.5
20
15.0
.210
41
500
14 7/.0242 .073
22.5
20
15.0
.190
31
500
16 7/.0193 .058
22.5
20
15.0
.175
24
1000
18 7/.0151
.045
22.5
20
15.0
.165
20
1000
TYPE SNA-- TABLE XBSO--STANDARD DIAMETER---(Same diam. as our Table BS, NEMA Table 11)
8
7/.0486
.146
22.5
27.5
20
.290
82
500
10 7/.0385 .116
22.5
27.5
20
.260
59
12
7/.0305
.092
22.5
27.5
20
.235
43
500 "-r
14
7/.0242
.073
22.5
27.5
20
.215
33
500
16 7/.0193 .058
22.5
27.5
20
.200
27
1000
18 7/.0151 .045
22.5
27.5
20
.185
21
1000
1000 1500 2000 2500 2500 3000
1000 1500 2000 2500 2500 3000
Finished diameters given above are average. A tolerance o( plus or minus 5% is necessary due to variations in process of manufacture. NEMA dielectric test voltage 3.0 Irilovolta on all lists.
RBB 00352
46
^ ==== = ROCKBESTOS
600 VOLT FLEXIBLE
National Electrical Code Type SNA
SWITCHBOARD HINGE CABLE
1
s
<
I. *TANBIB TINNtO CSPPf* COHDI/CTO*
2. *TKTH{TIC RESIN
i. ftLTEB ASBESTOS
i. TLABtfROOT COTTON SftaiO
SYNTHETIC RESIN AND FELTED ASBESTOS INSULATION
Insulated with a seamless synthetic sheath, felted asbestos and flameproof cotton braid just like its companion wires, Rockbestos Type SNA Switchboard Wire and Cable, this Flexible Rockbestos Type SNA Switchboard Hinge Cable is also resistant to heat, flame, oil, grease, corrosive fumes and moisture. It is ideal for hinge or jumper connections on swinging panels, connections to swinging synchronizing meters, lamps and for general switchboard and panel work requiring a flexible con ductor. Approved for installations in temperatures ranging to 194*F. Match your board wiring by using it with either Rockbestos Type SNA Switchboard Wire shown on page 44 or Rockbestos Type SNA Switchboard Cable shown on page 43.
TWO DIAMETERS
You can obtain this cable in small and standard diameters. "Small" (Table XBH) for installations requiring the grouping of many wires of minimum size and weight in limited space. "Standard" (Table XBHO) in the same diameters as Rock bestos Switchboard Hinge Cable, Table BH shown on page 40, to permit perfect matching with previous wiring and a snug lit >n board fittings designed for the larger diameter.
APPROVED
This cable is National Electrical Code Type SNA and is listed by the Underwriters' Laboratories.
BRAID COLORS
Standard braid colors are gray and black. Red, yellow, blue, green, brown and white braids in plain colors and striped pat terns can be furnished on special orders. Be sure to specify braid color, size, quantity, type name, and table letters on your order. This also applies to Rockbestos Type SNA Switchboard Wire and Cable.
Sice A.W.G.
Stranding Tinned
Bare Diam.
Inches
Nominal Thickness
Synthetic Re*in
Nominal Thickness
Felted Asbestos
Nominal Thickness
Cotton Braid
Mils
Mils
Mils
Nominal Finished Diam.*
Inches
Approx. Net
Weight per M ft.
Pounds
Standard Shipping Lengths
(Feet)
Coils
Reels
TYPE SNA-TABLE XBH--SMALL DIAMETER--(NEMA Standard, No. 39-S4 Table 15)
$
133/.0112
.168
22.5
20
17.5
.300
85
500
10 105/.010 .120
22.5
20
17.5
.250
58
500
12 65/010 .095
22.5
20
15-0
.220
42
500
14 41/.010 .075
22.5
20
15.0
.200
31
500
16 26/.010 .059
22.5
20
15.0
.185
25
1000
18 16/.010 .045
22.5
20
15.0
.170
21
1000
TYPE SNA--TABLE XBHO--STANDARD DIAMETER--(Same diam as our Table BH, NEMA Table 13)
8
133/.0112
.168
10 105/.010
.120
12
65/.010
.095
14
41/.010
.075
16
26/.010
.059
18
16/.010
.045
22.5 22.5 22.5 22.5 22.5 22.5
25 25 25 25 25 25
20 -310 87
500
20 .260 60
500
20
.235
44
500
20 .215 33
500
20 200 27 10Q0
20
.185
22
1000
1000 1500 2000 2500 2500 3000
1000 1500 2000 2500 2500 3000
* Finished diameters given above are average. A tolerance of plus or minus $% is necessary due to variations in process of manufacture NEMA dielectric test voltage 3.0 kilovolts on all sizes.
RBB 00353
ROCKBESTOS
47
300 VOLT ALL-ASBESTOS RHEOSTAT AND STOVE WIRES
ELECTRIC RANGES, LABORATORY OVENS, COOKERS, HOTPLATES, STOVES, AND MANY OTHER ELECTRICAL HEATING DEVICES.
' "* 1
with Solid Plain Copper, Nickel or Monel Conductors
t
a HljilVlIfl I with Stranded Plain Copper, Nickel or Monel Conductor*
An ail-asbestos stove wire designed for use in electric ranges,
temp" or "Moistemp." Hi-temp impregnated insulation is heat
laboratory ovens, cookers, hotplates, and many other electrical
and flame resistant, whereas insulation impregnated with
heating devices requiring a heat resistant wire of this type for service voltages of 300 or lower.
Ample dielectric strength is provided by the dense, seamless, impregnated wall of felted asbestos which is applied to con ductors of either solid plain copper, nickel or monel. A tough, rugged asbestos braid of 43 mils thickness, tightly woven over the impregnated felted asbestos wall, supplies mechanical strength
Moistemp compound is heat, flame and moisture resistant. Be sure to specify your preference for either "Hi-temp" or "Mois temp" on your order; also the table letters indicating the type of conductor you prefer, and the braid color desired. Plain cop per, nickel and monel conductors are standard, but tinned or plated copper conductors and alloy conductors other than nickel or monel can be supplied on special order.
Biack, white, red, blue or grey are the standard braid finishes.
and additional resistance to heat and flame, or heat, flame and
Other colored braids can be processed on special order. For the
moisture, depending upon the impregnating compound used, "Hi-
same construction types for 600 volt service see pages 48 and 50.
Size A.W.G,
4 5 6 8 10 12 14 16 18
SOLID--Specify Table AC for Copper--Table AM for Monel--Table AN for Nickel
Bare Diara.
Nominal j j
Thickness j * Felted Wall j
Nominal Finished Diameter*
Approx.
Net Weight Per M Ft.
Stan dard Shippini Lengths
(FSCt)
Inches
.204 .182 .162 .128 .102 .081 .064 .031 .040
Mils
40 40 40 31
31 3i 31 3i
is*
i o< ;- u ; 9 , !8
1 i2 ; i :^
Inches
.375 355 .335 .280 .255 .235 220 .205 .195
Pounds
177 148 124
78 56 43 33 27 23
Coils
500 500 1000 1000 1000 1000 1000
Reels
1000 1000 1000 1000 2000 2000 2000 2000 3000
STRANDED--Specify Table ACS for Copper--Table AMS for Monel--Table ANS for Nickel
Size A.W.C.
4 5 6 8 10 12 14 16 18
Stranding
7/.0772 7/.0688 7/.0612 7/.0486 7/.0385 7/.0305 7/.0242 7/.0193 7/.0151
Bare Diam.
Inches
.232 .206 .184 .146 .116 .092 .073 .058 .045
Nominal Utiekness Felted Wall
Mils
40 40 40 31 31 31 31 31 31
1. C u
K t 5ft < 's
iZ
$
Finished diameters given above are average. A tolerance of plus of minus
Nominal Finished Diameter*
Approx. Net Weight Per M Ft.
Stan dard Shipping Lengths
(Ft
Inches
Pounds
Coils
.405
183
.380
152
.353
128
500
.300 82 500
.270
59 1000
.245
44 1000
.225
35 1000
.210
28 1000
.200
23 1000
is necessary due to variations in process of manufacture.
Reels
tooo 1000 1000 1000 2000 2000 2000 2000 3000
RBB 00354
48
-- ROCKBESTOS
-----------
600 VOLT ALL-ASBESTOS RHEOSTAT WIRE
GRID JUMPER CONNECTIONS CONNECTIONS FROM GRIDS TO FACEPLATES SWITCHBOARD WIRING IN HOT LOCATIONS ELEVATOR AND LOCOMOTIVE CONTROL PANEL WIRING AND GENERAL OPEN WIRING EXPOSED TO HEAT, FUMES, FIRE HAZARD, OIL OR GREASE
i*
*
l. PUhtM COFPIR COMbUCtOR
a. mnp unnu
). tllttrOI II4ID
Asbestos rheostat wire was originally produced by put
formed. That means that, through repeated heating and
ting two or three braids of asbestos yam on the wire and
cooling cycles, the compound can never fall away from
finishing each braid with compound. This had several
the asbestos. The dielectric strength and moisture resist
disadvantages. For example, its moisture resistance was
ance of Rockbestos Rheostat Wire are, therefore, practic
very low due to the comparatively open covering so that
ally constant. And there is none of the usual flaking
many engineers considered that spaced wiring was neces
when working with Rockbestos Rheostat Wire and Cable,
sary in order to prevent possible leakage under damp
with either white or black braid.
conditions. The labor cost of doing this type of wiring
Because of its comparatively high moisture resistance
is high.
Rockbestos Rheostat Wire may be bunch-wired with per
Another disadvantage -- though really more of an
fect safety. The illustrations on page 49 show several
annoyance --- was that in working with this wire a good
examples of rheostats bunch-wired -with Rockbestos
deal of the compound flaked off and continued to do so
Rheostat Wire and Cable in several of the country's large
after the installation was completed, spoiling the appear
power stations.
ance of an otherwise nice job.
Rockbestos Rheostat Wire is recommended for all
m
The Rockbestos development of the felted and im
open work at 600 volts or less where wiring will be
pregnated wall of asbestos insulation was a distinct im
subject to heat, fumes, oil, grease or fire hazard.
provement. Instead of a relatively open covering on the
The insulation is generally impregnated with black
wire, the asbestos is applied in the form of a homogene
compound, but the braid finish can be either black or
ous insulation. The dielectricstrengthistherebyincreased.
white. Specify which. Colors may be furnished on
Next, the impregnating compound is an integral part of
special order.
the insulating wall, not painted on after the wall is
N. E. Code Type AI, listed by Underwriters' Lab.
Size A.W.C.
0000 000 00 0 1 2 3 4 5 6 8 10 12 14 16 18
TYPE AI--TABLE A--600 VOLT SERVICE (NEMA Standard No. 39-54 Table 20)
Bare Diam.
Inches
.460 .410 .365 -325 .289 .258 .229 .204 .182 .162 .128 .102 .081 .064 .051 .040
Felted Wall
Mils
60 60 60 60 60 40 40 40 40 40 31 31 31 31 31 31
cr.
.Nominal
Finished
Diam.*
" SB Indies
C
b.
.670
g .620
.575 C .535
SB .500 SB .430
SB hi
.400
.375
c .355
u. .335
C .280
V. <r.
.255
.235
* .220 .205
.195
Approx. Net
Weight per
M Ft.
Pounds
761 620 477 388 316 248 202 167 138 121
79 58 42 34 28 24
standard Shipping Lengths
(Feet)
Coils
500 500 1000 1000 1000 1000 1000
Reels
450 500 500 500 500 1000 1000 1000 1000 1000 1000 1500 1500 2000 2000 2000
f.'I!isAedJ d,,arne'er* *>ven above ire average. A tolerance of plus or minui 4% it necetiary due to variationt in process of manufacture. NEMA dielectric test voltage l.S kilovolts on all sites.
RBB 00355
ROCKBESTOS
Typical Rockbestos Rheostat Wiring Installations
49
RBB 00356
50
ROCKBESTOS
600 VOLT ALL-ASBESTOS POWER AND RHEOSTAT CABLE
same uses as table "a" wire
MWHERE STRANDED CONDUCTOR IS REQUIRED
ii
>
I. STtANDCO PLAIN COPPER CONDUCTOR
*. PUTCD ASSCSTOS
J. AAICSTOA BRAID
This cable is National Electrical Code Type AI, listed by the Underwriters' Laboratories. Standard braid finishes ate black or white, colors on special order.
Sice
TYPE AI--TABLE R--600 VOLT SERVICE (NEMA Standard No 59-54 Table 2\)
Stranding
Bare Diam.
Nominal Thickness
Feked WaU
Nominal Finished Diam.*
Approx. Net
Weight
Pr M Ft.
Star dsrd Shippini Lengths
(F eet>
Inches
Mils
Inches
Pounds
Coils
Reels
1,000,000 CM 950,000 900,000 850,000 800,000 750,000 700,000 650,000 600,000 550,000 500,000 450,000 400,000 350,000 300,000 250,000 A.W.G. 0000 000 00 0 I 2
3 4 5 6 S 10 12 14 16 18
61/. 1280 61/.1248 61/.1215 61/.1180 61/.1145 61/. 1109 61/.1071 61/.1032 61/.0992 61/.0950 37/.1162 37/.1103 37/.1040 37/.0973 37/.0900 37/.0822
19/. 1055 19/.0940 19/.0837 19/.0745 19/.0664 7/.0974 7/.0867
7/.0772 7/.0688 7/.0612 7/.0486 7/.0385 7/.0305 7/.0242 7/.0193 7/.0151
1.152 1.123 1.093 1.062 1.031 .998 .964 .929 .893 .855 .814 .772 .728 .681 .630 .575
.528 .470 .418 .373 .332 .292 .260 .232 .206 .184 .146 .116 .092 .073 .058 .045
120 1.485 120 td 1.455
120 1.425
120 1.395
120 < 1.365
120 K 1.330
120 2 1.295
120 1.260
120
1/5 1.225
120 S 1.185
120 1.145
120 < 1.105
120 m 1.060
120 120
ce &
1.015 .960
120 s .905 o
90 o .800 90 </> .740 90 u .690 90 z .645 90 .605 60 E .505 60 .470
60 .445
60 .420
60 .395
40 .320
40 .290
40 .265 40 .245 40 .230
40 .215
3456 3291 3126 2961 2796 2631 2470 2307 2142 1977 1812 1647 1482 1317 1219 982
819 672 555 462 388 274 227 188 157 132
87 63 48 38 31 26
500 500 500 1000 1000 1000 1000
500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500
1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
J'lS"1.diameter* given Above Are average. A tolerance of plus or mimia S% it necessary due to variations in process of manufacture NEMA dielectric test volt*(e 1.5 kilovolts on *11 sixes
RBB 00357
ROCKBESTOS
600 VOLT FLEXIBLE ALL-ASBESTOS APPARATUS CABLE
SAME USES AS RECOMMENDED FOR TABLE "a" AND "r" WIRES
WHERE A FLEXIBLE CONDUCTOR IS REQUIRED
51
ti
i nnitii tinmco eoc cokBueT
i
*. rtkice assutos
j. tninM seats
This cable has the sunt general uses as the solid and coarse stranded Rheostat Wires shown on pages 48 and 50.
It is recommended wherever a flexible lead roust be installed under high temperature conditions and where there will be no great amount of moisture.
Although we recommend the A.V.C Motor Lead and Apparatus Cable shown on page 53 for general motor use, some steel mills use this flexible stranded All-Asbestos cable where leads will be exposed only to high temperatures and where the possibility of moisture is remote.
This cable will not deteriorate under constant high temperatures. It positively will not burn, it will be found useful, therefore, for open work, such as jumper leads, etc., at voltages of 600 or less, under condi tions of heat and fire haxard. Neither grease nor oil can rot this cable nor cause it to bloom or swell. This cable is National Electrical Code Type AI, listed by Underwriters' Laboratories.
The insulation is usually supplied impregnated with black compound but the braid finish can be either white or black. Specify which. Colored finishes on special order.
TYPE AI--TABLE RF--600 VOLT SERVICE (NEMA Standard No. 39-54 Table 34)
Sue
Stranding Tinned
Bare Diam.
Felted WaU
Finished Diam.*
Approx. Net
M Ft.
Standard Shipping Lengths
(Feet)
500,000 CM 450,000 400,000 350,000 300,000 250,000 A.W.G.
0000 000 00 0 1 2
3 4 5 6 8 10 12 14 16 18
427/.0342 427/.0325 427/.0306 427/.0286 427/.0265 427/.0242
259/.0286 259/.0255 259/.0227 259/.0202 259/.0180 133/.0224 133/.0199 133/.0177 133/.0158 133/.0141 133/.0112 105/.010 65/.010 41/.010 26/.010 16/.010
Incites
.923 .878 .826 .772 .716 .653
.600 .536 .477 .424 .378 .336 .299 .266 .237 .212 .168 .120 .095 .075 .059 .045
Mils
Inches
120 120
Vu) N
1.255
1.210
120 d 1.160 120 1.105
120 as 1.050
120 g
.985
90 ih
a90 3
90
90 <
90 a 60 te
s60 u
60 60 o
60 40 V) 40 ti) 40 z
40 CJ
E40
40
.870 .810 .750 .695 .650 .550 .510 .480 .450 .425 .340 .290 .265 .245 .230 .215
Pounds
1910 1735 1560 1385 1211 1035
860 708 581 482 407 290 240 203 166 140
92 65 49 38 31 27
Coils
500 500 500 1000 1000 1000 1000
Reels
500 500 500 500 500 500
1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
* <1i*tr* given above are average. A tolerance of plus or minus 5% is necessary due to variations in process of manufacture.
NEMA dielectric test voltage i.S kilovolts on all tires.
RBB 00358
52
....
- ROCKBESTOS =====
300 VOLT EXTRA FLEXIBLE
ALL-ASBESTOS APPARATUS CABLE
MOTION PICTURE PROJECTORS, SUN ARCS, EFFECT MACHINES, HIGH TEMPERATURE LIGHTING FIXTURES, SPOT LIGHTS, ETC.
. OP( LAY STANDC0 AUIK >-OYAt COMeuCTO*
1. rtLTIO tlltl'OI
. UltlTOt **Al#
This cable was originally developed to meet a specific application in the lamp houses of motion picture projectors and in sun-arc lamps. Hence its frequently used name "Motion Picture Cable."
This is a more flexible version of the Table RF cable shown on page 51. Where a 259 stranding is used in Table RF size 2/0, for example, this cable has a stranding of 5292 -- the most flexible cable it is possible to design.
In standard construction both the felted asbestos insulation and the asbestos braid are impreg nated with standard white heat-resisting compound. Either the insulation or the braid, or both, can be impregnated with moisture-resisting compound but with the sacrifice of some flexibility.
Rockbestos Extra Flexible All-Asbestos Apparatus Cable in dry places, such as lamp houses, arc lamps, etc., can be operated under continuous high temperatures yet will stay permanently flexible. It positively cannot support combustion even when subjected to direct contact with an electric arc. This cable is National Electrical Code Type A, listed by the Underwriters' Laboratories. NOTE: This extra flexible stranding an also be supplied with A.V.C. insulation as shown in Table L illustration on page 33.
Six* A.W.C.
0000 000 00 0 1 2 4 6 8 10 12 14 16 18
TYPE A--TABLE W --300 VOLT SERVICE (NEMA Standard No. 39-54 Table 30)
Stranding
Bare Diaxn.
Inches
Nominal Thickness
Felled Wall
Mila
J cr
5 eSi
Nominal Finished Diam."
Inches
Carrying Capacity in Amps.
Approx. Net
Weight per M ft.
Pounds
Standard Shipping Lengths
(Feet)
Coils
8464/36 6713/36
5292/36 4214/36 3332/36 2646/36 1666/36 1050/36
661/36 413/36 259/36 105/34
65/34 41/34
.675 .600 .550 .47C .425 .365 .280 .215 .165 .130 .102 .077 .061 .047
55 in 55 s 55 55 55 40 t 40 s 40
31 31 t 31 31 31 31
.8,5 .800 .750 .670 .625 .535 .450 .385 .320 .285 .255 .250 .215 .200
325 815
150
275 660 150
225 535 150
200 430 200
150 340 200
125 260 200
90 175 250
70 125 500
50 80 500
35 55 500
30 39 1000
20 30 1000
10 24 1000
6 20 1000
Finished diameters given Above are average. A tolerance oi plus or minus 5% is necessary due to variations in process of manufacture. NEMA dielectric teat voltage 1.0 kilovolt for all sizes.
RBB 00359
ROCKBESTOS
300 VOLT HEAT RESISTING FIXTURE WIRES
far
{ LIGHTING FIXTURES, SMALL MOTOR LEADS, WIRING OF ELECTRIC RANGES, ELECTRIFIED OFFICE EQUIPMENT, RADIO APPARATUS, MINIATURE SWITCHBOARDS
NATIONAL ELECTRICAL CODE TYPE AF -- PLAIN (NO BRAID)
--Hi.
White Asbestos Insulation
Black Asbestos Insulation
NATIONAL ELECTRICAL CODE TYPE AF--BRAIDED
53
Solid Color Braid
Solid Color Braid with Marker
Electrical maintenance men are frequently called on to
BRAIDED type wires should also be used in pairs, the
Tepair burned out lighting fixtures and to make up and
wire with the marker thread going in the grounded side of
install new fixtures in plants, offices and public buildings.
the circuit and connecting to screw shell socket terminals.
To assist them in using the proper type of wire to meet
Code regulations we publish this dita on Rockbestos
ORDERING INFORMATION
Fixture Wires and Flexible Cords.
Standard Packinc: Both Plain and Braided Fixture
CODE REGULATION Article 410, Section 4139 of the National Electrical Code stipulates that fixtures operating at not more than 300 volts
Wire are put up on metal spools snd in coils, snd where quantity warrants (5000'to 10,000 ft. depending on size! on ftetory reels.
between conductors, which may be subject to temperatures
Concurrent Windinc: When s Plain Black and a Plain
in excess of 194* F,, (90* C.) must be wired with Type AF
White Wire, for example, will be used together it is con
fixture wire, or Type AFC, AFPO or AFPD flexible cord.
venient to have both wires wound on the same spool or reel.
See page S4 for cords.
To get this package specify "concurrently wound." The
&
APPROVED BY UNDERWRITERS' LABORATORIES Rockbestos Fixture Wires are approved by the Under
writers' Laboratories for lighting fixture use and bear tbeir labels. Insulated as they are with asbestos, the basic heatresisting and fireproof material, Rockbestos Fixture Wires are ideal for lighting fixtures because at socket tempera tures (frequently as high as 3S0 F. in modem flush type
same applies to braided wires. A concurrently wound spool of 1000 ft. of plain single conductor wire contains 500 ft. of black and 500 ft. of white wire wound together and so stated on the tag or spool label.
Stock Colors and Braids: Rockbestos PLAIN Fixture Wire is carried in stock in Black and White in the sizes listed in the table below.
fixtures) the insulation presents no fire hazard whatever nor
In addition to the Black and White, Rockbestos PLAIN
will it dry out and become hard and brittle. Furthermore,
Fixture Wire can also be supplied in Red, Blue, Green,
this insulation has higu moisture resisting character
Yellow. Gray, Brown, etc., on special order at no extra cost.
istics, an important factor where fixtures hang in damp
Rockbestos BRAIDED Fixture Wire is available in solid
atmospheres.
colors of Mahogany Brown, Brush Brass and Black in both
HOW TO SELECT
For fixtures where the wiring is concealed in stems or brackets, the PLAIN type wire is recommended. It has no braid. Made in Black and White to indicate polarity.
When wiring is exposed, such as on a chain pendant
glazed cotton and rayon. These colors are also available with marker threads in the braids: Red marker in the Mahogany Brown and Black braids and Olive Green marker in the Brush Brass braid.
In ordering specify:
fixture, the BRAIDED wire is recommended. Made in
A.W.G. size and stranding.
solid color braids and solid color with marker thread to indicate polarity.
Whether Plain type or Braided type. If Plain, whether half the order Black, other half
CODE METHOD OF WIRING
White finish, or all one color.
The PLAIN type wire should be used in pairs, one White
If Braided type, whether half order solid color braid,
and one Black. The White wire should be placed in the
other half with marker or all one way.
grounded side of the circuit and connected to the screw
Color of Braid
shell terminals of the sockets.
Whether Rayon or Cotton Braid.
TYPE AF--TABLE FS --300 VOLT SERVICE (NEMA Standard No. 39-54 Table 50)
Size A.W.G.
Minimum Wall
Stranding Thieknea* Insul.
Ave. Finished Diana.*
Plain
Ave.
Finished Diam.* Cotton Covered
Ave. Finished Duun.*
Rayon
Covered
Approximate Net Weight per M feet Pounds
Standard Shipping Lengths
(Feet)
Inches
Inches
Inches
Inches
Plain
Cotton
Rayon
Spools
Coils
10**
105/30
.040
.205
.230
.220
47
51
50 250 500
10
105/30
.047
220
.245
.235
51
55
53 250 500
12**
65/30
.040
.180
.205
195
33
37
36 250
500
12
65/30
.047
.195
.220
.210
36
40
38 250 500
14
41/30
.031
.140
.165
.155
20
23
22
500
1000
16
26/30
.031
.125
.150
.140
15
17
16
500
1000
18
16/30
.031
.110
.135
.125
11
13
12
500
1000
Finished diameters *iven above are averaft. A tolerance of plus or minus ** Not approved by the Undwwriters' Laboratories as fixture wire.
is necessary due to variations in process of manufacture.
RBB 00360
54
ROCKBESTOS
300 VOLT HEAT RESISTING FLEXIBLE CORDS
PENDANT CORD LIGHTING FIXTURES, INSTRUMENT LEADS, GLUE POTS AND OTHER SMALL HEATING DEVICES
TWISTED PAIR TABLE FA
tVAXfC COTTON 01 AAT0N RAID
N. E. CODE TYPE AFC
DUPLEX--TABLE FR
plain eeppt* conoucto*
Assmot
et katon i*ai
N E. CODE TYPE AFPD
ALAIN COAAIA CONOUCtOA
N. E. CODE TYPE AFPD
PLAIN COAACA CONOUCTOA
ASItSTOS
OA ALTON *AAI0
N. E. CODE TYPE AFPD
These cords are useful for lighting pendants and for apparatus
and test leads where a non-deteriorating heat resitting cord it
required.
.
CODE REGULATION
Article 410, Section 4139 of the National Electrical Code stipulates that fixtures operating at not more than 300 volts be tween conductors, which may be subjected to temperatures in excess of I94*F. (90 *C.), must be wired with Type AF fixture
wire, or Type AFC, AFPO or AFPD flexible cord. See page 53 for fixture wire.
APPROVED BY UNDERWRITERS' LABORATORIES
Rockbestos Heat Resisting Flexible Cords are approved by the Underwriters' Laboratories for lighting fixture wiring under the type symbols shown beneath the illustrations.
APPLICATIONS
In lamp sockets the usual temperature rise is from $0 to 200s C. above ambient depending upon the lamp wattage, type of shade and other factors. Experience has shown that with rubber fixture cord in use, the insulation of the wires in and immediately above the socket dries up and becomes brittle until finally, with the repeated movement of the pendant, due to opera tion of the chain pull socket or from vibration, the insulation just above the socket cracks and crumbles, permitting the wires to short circuit.
In consideration of this condition, therefore, it is especially im portant to use genuinely heat-resisting cord whose insulation will
not dry up and thus crack and eventually cause short circuits. Rockbestos Duplex or Twisted Pair Cord it ideal for this purpose.
The Twisted Pair and Triplex Cords hsve similar uses to the Duplex. The Triplex is for lighting fixtures having pendant outlet-twitches, two filament lamp fixtures, three heat appliances and leads for apparatus, meters tnd testing.
POLARITY MARKING
In the Twisted Pair Cord the marker thread in the braid of one wire indicates polarity. In Duplex end Triplex Cords the insula tion of the individual conductors is impregnated in different colors for the same purpose.
CODE METHOD OF WIRING
The wire with the marker thread in the Twisted Pair Cord and the white wire in the Duplex Cord should be connected to the grounded side of the circuit and to the screw shetl terminals of the socket.
STOCK COLORS AND BRAIDS
Twisted Pair: Mahogany Brown with Red Tracer, Black with Red Tracer, Brush Brass with Olive Green Tracer in both rayon and glued cotton.
Duplex: Black glazed cotton only. Triplex: Black glazed cotton only. Other colors and rayon braids can be supplied on special order.
IN ORDERING
Specify A.V.G. size, stranding (see tables) whether twisted pair, duplex or triplex, color of braid and whether glazed cotton or rayon.
Size A.W.C.
Stranding
Approx. Finished Diameter* Inches
Cotton Braid Table Table Table
FA FR FC
Rayon Braid
Table Table Table FA FR FC
Approx. Net Weight per M Feet Pounds
Cotton Braid
Table Table Table FA FR FC
Rayon Braid
Table Table Table FA FR FC
Standard Shipping Lengths
(Feet)
Spools Coils
10** 10 12** 12 14 16 18
105/30 105 '30
65/30 65 '30 41 .'30 26/30 16/30
.460 .490 .410 .440 .330 .300 .270
.435 .465 .385 .415 .305 .275 .245
.470 .500 .415 .445 -330 .295 .265
.440 .470 .390 .420 .310 .280 .250
.425 .455 .375 .405 .295 .265 .235
.460 .490 .405 .435 .320 .285 -255
104 111
74 80 45 33 25
102 109
72 78 45 33 25
151 161 106 115
66 49 36
101 108
72 78 44 32 24
100 107
70 76 43 31 23
148 158 104 113
64 47 34
250 250 250
500 500 500 500 500 500 500
* Finished diameters given above are average. A tolerance ol plua or minus 5% is necessary due to variations in process of manufacture. * Not approved by the Underwriters' Laboratories as flexible cord.
RBB 00361
ROCKBESTOS
300 VOLT ALL-ASBESTOS FLEXIBLE CORDS
PENDANT DROP LIGHTING FIXTURES, LOCOMOTIVES, BLUE PRINT MACHINES, FLOODLIGHTS, APPARATUS LEADS, ETC.
TWO CONDUCTOR
55
ii
I. mtNDCO PLAIN COPPCft JON6UCTO*
PCLTtD ASItSTOS
9. ASltSTOS 1A!0
Rockbestos All-Asbestos Cord was originally de veloped for cab and gauge lighting circuits of steam locomotives to replace rubber insulated cords which failed to stand up under heat and vibration. Because of this use it is widely known in the railroad field as Cab Cord.
There is no rubber whatever in this construction. Instead the basis of the insulation is asbestos, applied to the wire by our unique insulating process and im pregnated and compressed to form the felted asbestos wall. It meets a demand for a heat-resisting, fire proof, permanently flexible cord which will operate without failure under exposure to heat, corrosive fumes, oil, grease or fire hazard.
Because it will not dry and crack under heat, it makes an ideal heavy duty cord for pendant lighting fixtures located in high temperature areas in steel
mills, boiler rooms, kilns, glass plants, etc. It is also used for leads in heat-developing apparatus and for the wiring of blueprint machines, flood and spot lights and other high wattage units which develop temperatures that are ruinous to other types of insula ted wires.
For applications in which moisture may be encoun tered, use Rockbestos A.V.C. Flexible Cord described on page 56. Both types can be supplied with polarized conductors if so desired. If a perfectly round construc tion is desired it can be made up with fillers on special order at a slight additional cost.
RAILROADS NOTE: For lighting circuits in locomotives equipped with train control apparatus we recommend using Rockbestos A.V.C. Flexible Cord because of its higher insulation resistance.
300 VOLT SERVICE
Table CA--Two Conductor (NEMA Standard No. 39-54 Table 25) Table CAC--Three Conductor
Size A.W.G.
10 12 14 16 18
Stranding
105/30 65/30 41/30 26/30 16/30
Nominal Thickness
Felted Wall
Mils
31 31 31 31 31
Nominal Thickness Asbestos
Braid
Mils
45 45 45 45 45
Two Conductor -- Table CA
Nominal Finished Diam.*
Approx.
Net Weight
PerM Ft.
Standard Shipping Lengths
(Coils)
Inches
Pounds
Feet
.460
121
250
.400
84 500
.350
63 500
.320
50 500
.295
41 500
Three Conductor -- Table CAC
Nominal Finished Diam.'
Approx. Net
Weight PerM Ft.
Standard Shipping
Lengths (Coils)
Inches
Pounds
Feet
.485 168 250
.430 118 250
.385
85 500
.350
65 500
.320
51 500
* Finished diameter* given above are average. A tolerance oi plu* or minus S7r is necessary due to variations in process of manufacture. NEMA dielectric test voltage 1.0 kilovolt on all sites.
RBB 00362
56
ROCKBESTOS
600 VOLT A. V, C FLEXIBLE CORDS
EXTENSION CORDS EXPOSED TO HEAT, OIL AND GREASE IN STEEL MILLS, BOILER ROOMS, LOCOMOTIVES, REFINERIES, ETC. ALSO FOR PENDANT DROP LIGHTING FIXTURES AND FLOODLIGHTS EXPOSED TO HEAT AND MOISTURE
TWO CONDUCTOR
I. TAXOtO TIHNCO CONPUCTOft
t
l. FCITKO AtlttTOl
VABKISKtO CANdie
FCLTCO AOHT(
S. AJtCtTOS IRAIO
Rockbestos A.V.C. Flexible Cord was a natural
to use in heat-developing electrical equipment and
development of the AH-Asbestos Cab Cord and be
high wattage lighting units that may be operated
cause of its much higher insulation resistance found
where moisture exists. Approved for these uses, with
a special application in railroad locomotives equipped
polarized conductors, by the Underwriters' Labora
with train control apparatus.
tories under a 300 volt rating as Style V flexible cord.
This rugged cord has ample moisture resistance in
If so desired specify on order.
1&F
its combination of thoroughly impregnated felted
For general extension use where cord may be
asbestos and the embedded high-dielectric insert
dragged over masonry and rough floors nothing is
which makes up the familiar A.V.C. insulation. It
better than a good rubber jacketed cord but in places
has a heavy asbestos braid, the same heat-resistant and
where it is exposed to heat, oil and grease such cords
fireproof qualities as the All-Asbestos type and is
often fail electrically before they wear out mechanic
practically impervious to deterioration which ordinari
ally. In such service Rockbestos A.V.C Flexible
ly results from exposure to corrosive fumes or con
Cord frequently lasts longer.
tact with oil or grease.
For high dry temperatures use Rockbestos All
Rockbestos A.V.C. Flexible Cord should be used
Asbestos Flexible Cord described on page 55. Both
for the wiring of industrial type pendant lighting
cords can be supplied with polarized conductors if so
fixtures in hot locations where high humidity or mois
ordered. If a perfectly round construction is desired it
ture is prevalent. It is also the correct type of cord
can be made with fillers at a slight additional cost.
600 VOLT SERVICE
Table CV -- Two Conductor (NEMA Standard No, 39-54 Table 26) Table CVC -- Three Conductor
Size A.W.G.
Nominal
Nominal
Thickness Nominal Thickness
Stranding First Thickness Second Asbestos
Tinned Felted
V. C.
Felted
Braid
Wall
Insert
Wall Thickness
Two Conductor -- Table CV Three Conductor -- Table CVC
Nominal Finished Diam.a
Approx. Net
Weight Per M Ft.
Standard Shipping Lengths
(Coils)
Nominal Finished Diam.*
Approx. Net
Weight PerM Ft.
Standard Shipping Lengths
(Coils)
Mils
10 105/30 12 65/30 14 41/30 16 26/30 18 16/30
10 10 10 10 10
Mils
25 25 25 25 25
Mils
15 15 15 15 15
Mils
45 45 45 45 45
Inches
.515 .470 .430 -390 .360
Pounds
134 101 79 64 41
Feet
250 500 500 500 500
Inches
.565 .510 .465 .430 .400
Pounds
185 136 104
84 70
Feet
250 250 500 500 500
Finished diameters given above are average. A tolerance of plus or minus S% necessary due to variations in process ol manufacture. NEMA dielectric test voltage 2.S kilovolts on all siaes.
RBB00363
ROCKBESTOS ^..
A.V.C. SIGNAL WIRE -- continued from page 58
59
Coarse Stranding TABLE SC--600 VOLT SERVICE--TABLE SF Flexible Stranding
Size A.W.G.
Stranding Tinned
Bare Diaxn.
Nominal
Nominal Thickn'*
Thickn'* Felted
Braid
V. C.
Wall Thicknea*
Nominal Approx. Finished Net Wt. Diem.* per M Ft.
Standard Shipping Lengths
(Feet)
Coarse
Flexible Incite*
Mil*
Mil*
Mil*
Inches Pound* Coil*
Reels
0000 19/.1055 37/.0756 .528 40 40
000 19/-0940 37/.0673 .470 40 40
00 19/0837 37/.0600 .418 40 40
0 19/-0745 37/.0534 .373 40 40
1 19/.0664 37/.0476 .332 40 40
2 7/0974- 19/.0591 .292 40 40
5 7/.0867 19/.0526 .260 40 40
4 7/.0772 19/.0469 .232 40 40
5 7/.0688 19/.0417 .206 40 40
6 7/.0612 19/.0372 .184 40 40
8 7/.0486 19/.0295 .146 30 25
10 7/.0385 19/0234 .116 30 25
12
7/.0305 19/0185
.092
30
25
14 7/.0242 19/0147 .073 30 25
16
7/0193 19/0117
.058
30
25
18 7/.0151 19/0092 .045 30 25
* Finished diameters given above are average. A tolerance of plus or minus
27
.745
862
500
27
.685
700
500
27 .635 578
500
27
.590
481
500
27
.550
400
1000
27
.510
334
1000
27
.475
285
1000
27
.450
242
1000
27 .425 208
1000
27 .400 178
1000
25 .310
96 500 1000
25 .280
71 500 1000
25 .255
54 500 2000
25 .235 41 500 2000
25 .220
33 500 2000
25 .205
27 500 2500
is necessary due to variations in process of manufacture.
600 VOLT A, V. C. HEADLIGHT WIRE
( LOCOMOTIVE LIGHTING AND CONTROL CIRCUITS '' /Of 1 IN WHICH A SINGLE CONDUCTOR WIRE IS PREFERRED.
IIS
I. STItAHOtO TIMKCO coerce CONSUCTOa
2. VARNISHES CAUSAIC
4
1. FELTED ASSESTOS
4. rtAMtPAOOf COTTON ARAIO
For certain applications on railway locomotives a single conductor wire is more convenient to use than duplex A.V.C Flexible Cord construction shown on page 56.
Rockbestos A.V.C. Headlight Wire has the same characteristics that are to be found in other A.V.C. con structions -- ample dielectric strength and insulation resistance, absolutely fireproof and highly resistant to heat and moisture, oil, grease and corrosive fumes. Under high temperatures the insulation will not flow or bloom to cause plugging of pipes or conduit. Recommended for all locomotive lighting circuits and similar applications where a single conductor wire of small diameter is preferred.
TABLE T -- 600 VOLT SERVICE (NEMA Standard No. 39-54 Table 29)
Size A.W.G.
Stranding Tinned
Nominal Thickness
V. C.
Mil*
Nominal Thickness
Felted Wall
Mils
Nominal Finished Diameter*
Inches
Approx. Net
Weight Per M Ft.
Pounds
Stan dard Shipping Lengths
(Feet)
Coils
Reels
10
19/0234
25
12
19/0185
25
14
19/0147
25
16
19/0117
25
18
19/0092
25
25 .255 59
500 1500
25 .230 44
500 2000
25 .210 34
500 2500
25
195
28
1000
2500
25
.185
24
1000
3000
* Finished diameters given above are average. A tolerance of plus or minus S% is necessary due to variations in process of manufacture. NEMA dielectric test voltage 2.S kilovolts on all sizes.
RBB 00364
60
ROCKBESTOS
A.V.C. AND ALL-ASBESTOS PYROMETER WIRE
All-Asbestos Type Single Conductor -- Table YS
A\V,<7 TypeT .. vr Single Conductor -- Table YC
,
I. CONDUCTOR
4 I. VttNlSHCS CaultlC
*
*. FtLTCS AS1UTOJ
4. ASBCSTOS MAIO
In brick plants, steel mills and petroleum refineries pyrometer lead wire, variously known as com pensating lead or extension wire, has always been a source of considerable trouble.
Rubber insulated wire was generally used, either with or without a lead sheath, or with a socalled "slow-burning" covering consisting of two or three cotton braids finished with flameproof paint. These constructions were unsatisfactory because heat dried out >and cracked the rubber and oil caused it to bloom and rot, setting up short circuit possibilities and permitting the picking up of stray ground potentials and admission of moisture which affected the accuracy of the readings. The lead sheath construction took care of moisture and protected the rubber from oil and fumes but proved to be a liability when fires involving pyrometer circuits melted the lead and rubber. This frequently plugged the conduit to such an extent that it was often impossible to remove the wire,
and conduit as well as wire had to be replaced. When engineers sought to avoid this trouble by using "slow-burning" insulation they found that it had no moisture resistance and that it took up moisture which was occasionally present in the conduit with the result that the readings were thrown off.
Thermocouples or "fire-ends" have also presented a problem as those in which the wire is insu lated with lava beads require considerable time for assembly, are fragile and slow in delivery. In another type the conductor is tediously wound with asbestos yarn and then dipped several times in silicate of soda to produce a poor makeshift for an homogenous wall of insulation.
Obviously, these applications require a wire that is not only heat and moisture resisting but fireproof as well, and that is what we offer in Rockbestos Pyrometer Wire.
It will not grow hard or brittle fior crack under temperatures that would be destructive to other
types of insulation, neither will it rot or bloom even if exposed constantly to oil, oil fumes or grease. If fires involve the circuits there will be no plugging of conduit and in many cases the wire will con tinue to operate properly. These qualities are inherent because the insulation is made from asbestos, the basic heat-resisting and fireproof material.
TWO TYPES OF INSULATION
We offer Rockbestos Pyrometer insulation in two types the same aa we apply to cable. If preferred either construction may be had with lacquer finished cotton braid instead of an asbestos braid.
HOW TO SELECT THE PROPER TYPE
If the conduits in which the leads are located are all indoors with no very long runs, and generally subjected only to heat, oil or fumes and no more than casual moisture, the All-Asbestos insulation will be satisfactory. If the conduit run is both outside and inside heavy condensation is likely and in that case, and whenever you are doubtful, we recommend the A. V. C. insulation. Varnished cambric embedded in the felted asbestos wall of the A. V. C. insulation gives the extra dielec tric strength necessary under moisture conditions.
For thermocouples the use of single conductor All-Asbestos Pyrometer Wire is invariably dictated by the high tempera tures to which they are exposed but for applications where the thermocouple is extended to form a lead the A. V. C. type is recommended because of the possibility of excessive humidity or moisture.
HOW TO ORDER
We can supply All-Asbestos or A. V. C. insulated single conductor pyrometer wire with solid or stranded iron, or solid or stranded copper conductors. These insulations are also applied to conductors furnished by the customer. `See last para graph.
We also offer the parallel construction illustrated above but can furnish a duplex construction if the conductor! are stranded. Both are covered with an asbestos braid and polarity identification can be had without extra charge by means of either colored asbestos insulation or a marker thread.
There are so many combinations of solid or stranded conductors and dissimilar metals that it is impossible to tabulate them but we will quote prices on any combination on request. Let u know site, whether solid or stranded, enameled or plain copper, what combination of copper, iron or alloy conductors you are using, and whether you want to use two single conductors or to combine both under one braid and we will draw up specifications and quote.
NOTE: When specifications call for an alloy conductor it must be furnished by the customer as we can not accept the responsibility of supplying alloy conductor having the proper thermoelectric characteristics.
RBB 00365
ROCKBESTOS
THERMOSTAT CONTROL WIRE
LOW VOLTAGE SIGNAL AN INTERCOMMUNICATING SYSTEMS, AUTOMATIC FUEL BURNER CONTROL, ETC.
*1
The wiring of the control systems of early automatic coal and oil burning installations formerly gave frequent trouble. To get short runs it was often installed dose to, or actually resting on, hot water or steam pipes and the heat naturally deteriorated ordinary insulated wire to the point where trouble fre quently occurred. Cases are on record where serious damage has resulted from faulty control wiring.
Abrasion, too, has always been a source of trouble when fishing ordinary control wire, particularly in
buildings already up. Sharp corners, brickwork, plaster, protruding nails and rough beams all tend to
damage the insulation.
`
With these conditions in mind, and with the wide adoption of automatic fuel burning systems, a large manufacturer of heat control apparatus asked us to design a wire which would be heatproof and abrasion resisting -- and Rockbestos Thermostat Control Wire was the result.
Rockbestos Thermostat Control Wire is very strong mechanically because of its firm felted asbestos insulation and its rugged, abrasion resisting spiral steel armor or metal braid. It is heatproof and will not dry out under heat or with age. It eliminates fire hazard because it cannot burn. Neither can rats damage it as has been known to happen occasionally with unprotected wires. Where resistance to abrasion or pro tection against rodents is not essential, a cotton braid may be specified instead of metallic sheath. With these advantages it is of value for Control and intercommunicating systems or for any similar application where a low voltage, multi-conductor cable is required.
Rockbestos Thermostat Control Wire is designed to be used at low voltages, usually fed by a stepdown transformer. For this application the 12i/2 mil wall insulation is generally used. However, some users prefer the 25 mil insulation thickness for its added mechanical and dielectric strength. Where this cable is to be used direct on 115 volt circuits a minimum insulation thickness of 31 mils is required. Data for cables with all three insulations is listed in ':he table below.
Note: The metal braid covering mentioned in the fourth paragraph is an optional suggestion.
Sice A.W.G.
16 16 16 16 18 18 18 18 20 20 20 20
TABLE TC
Nominal Well Thkknewe*
Ftaririied Diameters* (Indie*)
Number of Conductor* For Low Vohaffe Sendee
115 Volt Service
12Vt Mil O. D.
25 MU O. D.
31 Mil O. D.
Approximate Net Weight* per M Feet (Pound*)
For [*v Voltage Service
US Veh Service
12 Vj Mil
25 Mil
31 Mil
2
-175
.225
.265
35
43
47
3 .185 .240 .285
46
56
62
4 .210 .270 .315
58
69
79
5 .235 .305 .355
69
84
97
2 .155 .205 .245
26
34
37
3 .165 .215 .260
34
43
49
4
.180
.240
.290
43
53
61
5
.205
.275
.325
50
64
75
2
.135
.185
.225
21
28
31
3 .145 .200 .240
26
35
40
4
.160
.220
.270
32
42
50
5
.180
.250
.300
38
51
61
Standard Shipping Length*
(Feet)
Coils
500 500 500 500 500 500 500 500 500 500 500 500
Finished diameters given above are average. A toleranee of plus or minus 5% is necessary due to variations in process of manufacture.
RBB 00366
62
ROCKBESTOS
125 VOLT A. C SECONDARY NETWORK CABLE
t*
1. STftANBCD PLAIN C0PPC* CONOUCTOI
t tPCCIAL fcOCKMfTOi INSULATION
. LtAb SHCATN
Rockbestos Low Voltage A.C. Secondary Network Cable was developed exclusively lor secondary network distribution systems but several utility companies have extended its use, where regulations permit, to include service installations in which limited space, high ambi ent temperature and emergency overloads must be considered.
The problem of power companies operating second ary network distribution systems is to distribute power at high currents and low voltage. The circuits are tied in solid without the usual protective devices.
When a fault occurs in a cable, which may happen from any one of a number of causes, the successful operation of the network system depends upon the cable clearing itself. Obviously there should be sufficient transformer capacity to permit of this taking place. If, instead of clearing at once, the insulation or the cable bums, produces smoke, generates toxic, inflam mable and explosive gases, experience has repeatedly shown that the arc is supported by the gas and smoke so that large amounts of cable and manhole equipment are sometimes destroyed. More important, the smokefilled manholes delay trouble crews in making repairs and restoring service.
Under the worst fault conditions, whether single, two, or three-phase, loose or solid, Rockbestos A.C. Secondary Network Cable will dear deanly and quickly without burning or generating toxic, inflammable or explosive gases. It also definitely eliminates the smoke nuisance because neither the insulation, which is pure asbestos, nor the impregnating compounds will burn.
Another advantage is positive resistance to deteriora tion normally resulting from age or heat. Under over loads, when the cables become warm, there need be no fear of failure as the insulation will remain intact up to the melting point of copper. Practically, however, the melting point of the solder joints and the copper tem perature at which regulation difficulties would be experienced, determine the load the cable can carry.
JOINT TAPE:
We have developed an asbestos tape especially for
this new secondary network cable. It has similar char
acteristics to the new cable insulation so that its use is
consistent with the use of Rockbestos A.C. Secondary
Network Cable. Made in
width, foil wrapped, 5
yards to the package.
Size
500,000 CM 450,000 400,000 350,000 300,000 250,000 A.W.G.
0000 000 00 0 1 2 3 4
Stranding
37/.1162 37/.UQ3 37/.1040 37/.0973 37/.0900 37/.0822
19/.1055 19/.0940 19/.0837 19/.0745 19/.0664
7/.0974 7/.0867 7/.0772
Bare Diam.
Inches
.814 .772 .728 .681 .630 .575
.528 .470 .418 .373 .332 .292 .260 .232
TABLE UL
Nominal Insulation Thickness
Nominal Diameter
over Insulation
Thickness of
Lead Sheath
Mils
Inches
Inches
Nominal Diameter
over Lead*
Inches
Approx. Weight
with Lead
Maximum Manufac
turing Lengths
Pounds (Feet)
93 1.000 93 .958 93 .914 93 .867 93 .816
93 .761
7/64 6/64 6/64 6/64 6/64 6/64
1.220 1.150
1.105 1.055 1.005
.950
3640 3130 2895 2665 2425 2175
1500 1500 2000 2500 2500 3000
93
.714
6/64
.905
1980
3000
93
.656
6/64
.845
1745
3000
93
.604
6/64
.795
1555
3000
93
.559
6/64
.750
1390
3500
93
.518
6/64
.710
1255
4000
93
.478
6/64
.670
1140
4000
93
.446.
6/64
.635
1045
4000
93
.418
6/64
.610
980 4000
* Finished diameters given above are average. A tolerance o plus or minus S% is necessary due to variations in process o< manufacture.
RBB 00367
ROCKBESTOS
FIREPROOF LOW VOLTAGE VAULT CABLE
6}
i*
1 STIANOID PLAIN COPPC* CONOUCIOD
a t (PCCIAL ICCIItlfCI INSULATION
4 J. SYNTHETIC WALL
4 ASOCSTOS ItAIO
Rockbestos low voltage vault cable was designed to provide a heatproof, fireproof and moistureproof cable for bus installation in underground vaults of low voltage distribution systems. The typical instal lation is between transformers and network protectors, mounted on porcelain insulators without phase to phase or phase to ground contact.
The special insulation on Rockbestos Vault Cable is like the insulation in Rockbestos Secondary Net work Cable -- impregnated pure asbestos which is unaffected by heat or age and positively will not burn. In addition, to seal the insulation against the moisture so often encountered in underground vaults, a thin layer of waterproof synthetic tape material is applied over the asbestos insulation, under the asbestos braid.
With extreme overheating or actual fault conditions the only smoke or gas generated is from the decomposition of the synthetic waterproof tape layer, and is of such small quantity, due to the thin layer, that it is negligible and does not interfere with prompt access to the vault for service restoration.
Supplied with standard concentric stranding or segmental conductor.
TABLE UV
Sice
Stranding
2,000,000 CM 1,500,000 1,000,000
750,000 500,000 450,000 400,000 350,000 300,000 250,000 A.W.G.
0000 000 00 0
127/.1255 91/.1284 61/. 1280 61/.1109 37/.1162 37/.U03 37/.1040 37/.0973 37/.0900 37/.0822
19/1055 19/.0940 19/.0837 19/.0745
Bare Diazn.
Inches
1.632 1.412 1.152
.998 .814 .772 .728 .681 .630 .575
.528 .470 .418 .373
Nominal Thickness
Felted Wall
Nominal Thickness Synthetic
Wall
Mil*
Mils
155 20 155 20 120 20 120 20
93 20 93 20 93 20 93 20 93 20 93 20
93 20 93 20 93 20 93 20
1
"S i
in
2 2
| 9
r S
X
Nominal Finished
Diam*
Inches
Approx. Net
Weight Per M Ft.
Pound*
Maximum Manufac
turing Lengths
Feet
2.075 1.855 1.525 1.370 1.130 1.090 1.045 1.000
.950 .895
6838 5209 3482 2667 1796
1631 1467 1301 1135 967
500 500 1000 1000 1500 1500 2000 2500 2500 3000
.845 .790
.735 .690
838 3000
689 3000 570 3000 474 3500
* Pinished diameters given above are average. A tolerance of plug or minus
ia necessary due to variations in process of msnufacture.
RBB 00368
64
ROCKBESTOS
INDUSTRIAL HEATING CABLE
the even distribution of
MMILD HEAT OVER A LARGE AREA
LtAB SHtATH
MLT MIHfM
SAICtAL ALLOY tilt
Originally developed to provide a controllable heat source for forcing early plants in hotbeds, millions of feet of this beating cable is put in operation each spring by market gar deners, florists and amateur horticulturists.
Industry too, has discovered that this unique heating cable can be used in many applications to better advantage and more economically than spot or strip heaters. Pliable, easily bent and formed, it can be threaded through apertures, made to conform with irregular shaped objects and wound around pipe to accomplish the even distribution of mild heat over a large area. We can only touch on a few typical applications but they may give you an idea of the varied uses that can be made of the cable.
In many plants the cable is used as a safeguard against frozen water pipes making unnecessary the rearrangement of piping or costly replacement. Waste pipes, gutters and down
spouts can also be kept free and clear of ice. Paint, soap, varmsh, ink, chocolate, molasses and sulphur,
to name a few, can be kept at fluid temperatures, insuring
against irregular flow and dogged conveyor pipes. Wet pipe sprinkler systems located in unheated areas
are easiiy heated and kept at non-freezing temperatures that assure positive operation.
Steel mills use it around roll-necks to prevent the lubri
cant from congealing and a utilities engineer wound the cable around the pipes connecting the conservator tank to the main tank of a conservator type transformer, covered it with lag ging, and eliminated congealing of oil and freezing of con densate.
The resistance of Rockbestos Industrial Heating Cable is approximately 0.5 ohms per foot. In order to keep the temperature low enough so that the insulation will not be injured, the generally recommended length across 115 volts, is 60 feet. However, installations as short as 40 feet have been made with no evident harm to the insulation resulting from the higher temperature. The recommended wattage limit is 7 watts per foot. At 115 volts a 60 ft. length is rated at 400 watts, 6.66 watts per ft. Across 230 volts use a 120 ft. length for the same current value and double the total wattage.
When installed permanently, Rockbestos Industrial Heating Cable should be covered by some form of heat insu lating material for operating economy.
Precise temperature control is established by means of a low priced thermostat available from a number of manufacturers. We will be glad to refer you to several.
The characteristics of this particular heating cable are given simply because it is a standard product and usually available from stock. We are equipped, however, to make up heating cable with special characteristics to your specifications.
(We have literature describing and illtmrating industrial tad toil beating application!. Tell ua which you are interetted in.)
Size A.W.G.
Conductor
Approx, Resistance
Ohms per ft.
TABLE LH
Bare Diam.
Nominal Thickness
Felted
Wall
Inches.
Mils
Lead Sheath
Inches
Nominal Finished Diam.*
Inches
Approx. Net
Weight per
M Ft.
Pounds
Standard Shipping Lengths
(Feet)
19 Nickel Chrome
.50*5
.036 40 4/64 .245
60 and 120 198 and in bulk
on reels
* Pinifhed diameters given above are average. A tolerance of plua or ainua J% it nccetaary due to variations in proceas oi manufacture.
rBB 00369
ROCKBESTOS
Permanently Insulated
WIRES, CABLES AND CORDS
not included in this bulletin are ROCKBESTOS FIREWALL AVIATION WIRE ROCKBESTOS FIREWALL RADIO HOOKUP WIRE
and NUMEROUS SEMI-SPECIAL AND SPECIAL CONSTRUCTIONS THAT HAVE BEEN DEVELOPED FOR THE MANUFACTURERS OF:
AIRCRAFT EQUIPMENT
MARITIME EQUIPMENT
AUTOMOTIVE EQUIPMENT
MINING MACHINERY
ELECTRICAL APPARATUS
RADIO APPARATUS
ELECTRONIC CONTROLS
RAILROAD EQUIPMENT
LIGHTING FIXTURES
STEEL MILL MACHINERY
SWITCHGEAR
And For The Maintenance of Equipment and Power. Lighting and Control Circuits Exposed to Severe Operating Conditions in Electrical Power Plants and Miscellaneous Industries.
If a solution to your puzzling iviring problems is suggested by the listing above, write to us or the district office nearest you, furnishing as much detail as possible and we will be glad to make a recommendation.
ROCKBESTOS PRODUCTS CORPORATION
V. O. Drawer 1102, New Haven 4, Connecticut, U. S. A.
DISTRICT SALES OFFICES
NEW YORK 17. 5942 Grand Central Terminal
LOS ANGELES I). 520 East Third St.
ST. LOUIS I. 12' Railway Exchange Bldg.
CLEVELAND 14. 1159 Union Commerce Bldg.
PORTLAND 4. ORE. 209 S. V. Fir-: Avc.
SAN FRANCISCO 3, 567 Ninth St.
CHICAGO 3, 1449 Field Bldg.
BUFFALO 5. 564 Ellicot: >.j. Bldg.
SEATTLE 4, 1714 First Avc., So.
PITTSBURGH 19. 2157 Kopper- Bldg.
Manufactured in Canada by Phillips Electrical Works. Ltd. and distributed by Automatic Electric (Canada) Limited. 2S4 King Street. Vest. Toronto
Montreal--Brockville--Ottawa--Hamilton--Winnipeg--Regina--Edmonton--Vancouver
Manufactured in England and distributed by Brin-h Insulated Cables. Ltd., Present. Lancashire
Bulletin No. 10-E. SM. -45
Printed in United States oi America
RBB 00370
ROCKBESTOS CALCULATOR
''' '
FOR
CABLE SIZE-CIRCUIT LENGTH-LOAD-VOLTAGE DROP
FOR
ANY TYPE OF 600 VOLT INSULATED CONDUCTOR IN IRON CONDUIT REGARDLESS OF TYPE OF CIRCUIT--ROOM TEMPERATURE --NUMBER OF CONDUCTORS OR POWER FACTOR.
BASED ON 3--1/C CABLES IN A CONDUIT--ROOM TEMPERATURE 30*C.--100% POWER FACTOR--BALANCED CIRCUITS.
FACTOR
TO FIND CABLE SIZE REQUIRED FOR ANY LOAD--CIRCUIT LENGTH--VOLTAGE DROP Divide known Circuit Length by value of Vk in table for type of circuit and Circuit Voltage to find FACTOR M. Follow line for FACTOR M thus found until it intersects the line for the known Circuit Amperes. From this point READ the cable size. If this point is between two vertical cable size lines, the line to the right of the point should b3 the cable size. Example: Find size cable required to carry 50 Amperes on a 3-wire single phase 120-volts branch circuit. 240 ft. long and to have 1% Voltage Drop. From table, value of Vk is 1.2. Then FACTOR M= yy =200. Reading lrom Chart, the FACTOR M UNE for 200 intersects the 50 Ampere line between wire sizes 0 and 00; therefore a 00 cable would be required.
TO FIND CIRCUIT LENGTH FOR ANY LOAD--CABLE SIZE--VOLTAGE DROP From chart find FACTOR M from the intersection of the known cable size and load in amperes. Multiply the FACTOR M thus found by the value Vk found in the table for the type of circuit and circuit voltage to get the Circuit Length. Example: Find Circuit Length permissible for 1% voltage drop on a 2-wire 110-volt circuit of 8 conductors with a load of 25 Amperes. From chart, the line tor a 8 conductor intersects the 25 Ampere line to give a FACTOR M value of S7. Value of Vk from table for a 2-wire 110-volt circuit and 1% voltage drop is .5S0- Then the permissible circuit length is 57 x .550 =31.3 feet.
RBB 00371
TO FIND MAXIMUM TOAD FOB ANY CABLE SIZE--CtBCUIT LENGTH--VOLTAGE CHOP
\;
.
Divide known Circuit Length by value of Vk in table for type of circuit and circuit voltage to find FACTOB M. Follow line far FACTOR M thus found until it intersects the line for the known cable size and read the permissible Ampere'Load.
Example: Find the maximum load in amperes that can be carried on a three-phase 440-volt circuit -using #2 conductor for a circuit
length i 600 ieei and not exceeding 0% Voltage Drop. From tbe note under the table, the value oi Vk must be increased due
to 3% voltage drop permissible
Therefore, the value of Vk will be 2.54 the value shown in the table for a three phase
440-volt circuit multiplied by 3 or 2.S4 z 3=7.62. FACTOR M will, therefore, be-fjjjj =78.7. Following FACTOR M line for 78.7
until it intersects tbe line tor a conductor the maximum Ampere Load is found to be 70 Amperes. .
TO FIND THE VOLTAGE DROP FOR ANY LOAD--CABLE SIZE--CIRCUIT LENGTH
,
From chart, find FACTOR M from the intersection of the known cable size and load in amperes. Divide the Circuit Length by FACTOR M
thus found and then divide this result by tbe value of k (not Vk) shown in the table for the type of circuit. This gives the voltage drop in
volts. To find the per cent regulation, divide the voltage drop thus found by the system voltage.
.
v
Example: Find the voltage drop for a 2-wire 115-volt circuit of #2 conductor with a load of 20 amperes and a circuit length of ISO feet.
From the chart. FACTOR M for the intersection of #2 conductor and 20 amperes is 295. Then dividing the circuit length o! 150
feet by FACTOR M thus found gives *|2&=1.016 volts drop.
=.508. Then dividing this by value of k for a 2-wire circuit which is .5 gives
TO FIND ABOVE VALUES FOR OTHER ROOM TEMPERATURES
The current rating of conductors are reduced when operating at a room temperature above 30 *C. also if more than three- conductors are in the conduit. So in using chart be sure current value used or found does not sxcssd the value permitted by the National Electrical Code for these conditions. The accuracy of the chart may be affected as much as five percent when using these reduced current ratings, but will usually give a voltage drop higher rather than lower, so it is therefore conservative.
FOB OTHER POWER FACTORS THAN 100% POWER FACTORS
Divide the value of k or Vk shown in the table by the POWER FACTOR Correction Factor given in the table of Current Ratings. Actually a separate table of Power Factor Correction Factors for conductors size 0 and larger should be given for each type of insulation. The maximum degree of error for 1000 MCM by using tbe single table below is only about 10 percent., and as the table gives a higher
rather than lower voltage drop for insulated conductors having high copper temperature ratings. It is on the safe side.
ALLOWABLE CURRENT CARRYING CAPACITIES OF CONDUCTORS IN AMPERES
Based on National Electrical Code
For Not More Than Three Conductors in Raceway or Cable
(Based on Room Temperature of 30*C. 86*F.)
Paper
Size AWG MCM
Rubber Type RW
TypsR Type r
Synthetic Type SN
Latex Type BU
Rubber Type HPT TypeRP
Rubber Type RHT Type RH
Synthetic Type SNA Asbestos
Var-Cam. TvpeAVB
Var-Cam. Type V
Asbestos s
Var-Cam. Type
AVA AVI
- POWER FACTOR CORRECTION FACTORS
90S 80} 70%
60*
14 15 18 22 23 28 12 20 23 27 29 36 (0 25 3! 37 38 47 8 35 41 49 50 60 6 45 54 65 68 80
5 52 63 75 78 94
4 60 72 86 88 107
3'
69
63
99 104 121
2 80 96 IIS 118 137
1 9! 110 131 136 161
0 105
127
151
157
I9C
00 120 145 173 184 217
000 138 166 199 209 243
0000 160 193 230 237 275
.91 .91 .92 .92 .93
.95 .96 . .98 i.00 1.02
l.lt 1.15 1.20 1.28
.81 .82 .82 .83 .86
.87 .89 .91 .93 .96
1.09 1.15 1.22 1.32
.72 .73 .74 .75 .77
.79 .81 .63 .86 .89
I.OS 1.12 1.20 1.32
-
.62 .62 .63 .65 .67
.70 .72 .74 .77 .81
.99 1.07 1.16 1.29
250 177 213 255 272 315
300 198 238 285 299 347
350 216 260 311 325 392
400 233 281
336 361
418
500 265 319 382 404 466
1.33 1.41 1.46 1.54 1.66
1.40
1.50 1.60
1.66 1.85
1.41
1.63 1.65 t.74
1.94
1.40
1.54 1.67
1.77 2.00
600 293 353 422 453 525 700 320 365 461 488 562 750 330 398 475 502 582 800 340 410 490 514 600 900 360 434 519 556
1.79
1.90 1.95 2.00 2.10
2.02
2.19 2.24 2.31 2.45
2.15
2.34 2.40
2.48 2.64
2.24
2.45 2.52
2.61 2.80
1000 377 455 543 583 681
2.18
2.57
2.79
2.95
1250
409 434
493 522
589 625
643 693
784 CONSTRUCTION NOTE
1750 451 544 650 733
All Voltage Drops based on resistance of conductor at actual
2000 463 558 666 774 '839 temperature of conductor for each value of Load Amperes.
C F. CORRECTION FACTOR FOR ROOM TEMPERATURES OVER 30*C. Example: No. 2 Type R Rubber has a copper temperature of 50*C.
40 104
.71
.82
.86
.90
.94
with an 80-Ampere load and the resistance of the eon-
50 122
.00
.58
.75
.80
.87
ductor at this temperature is 0181 ohms per 1000 ft.
60 140 ... ...70 158
.00 .58 .67 .79 .35 .52 .71
For o load of 50 Amperes, the copper temperature is 40*C. and its resistance .0174 ohms pet 1000 It.
... ...60 176 ... ... ...90 194 ... ...100 212
.30 .61 The reactance values were calculated on a spacing of the outside .50 diameter oi the cable plus 10%, and for cable sizes 0 and
larger, the reactance value was increased 50% to compensate
lor the proximity effect and eUect of the iron conduit.
ROCKBESTOS PRODUCTS CORPORATION
NEW HAVEN
CONNECTICUT
RBB 00372
ED. HEERY, SALESMAN-BY-MAIL
for
ROCKBESTOS PRODUCTS CORPORATION
NEW HAVEN, CONNECTICUT
nchc 1 would this novel
Heating Cable
be useful to You?
Rockbeicos Industrial Heating Cable
4/64* Waterproof Lead Sbeath
Rockbestos Felted
Asbestos insulation
Special Alloy Resistance Heating
Conductor
TJERE'S a heating device all wrapped up in a small pliable cable that you can bend and form to fit 'most anything. Better than that, it distributes a mild even heat
over almost any area you might want to cover, which makes it much more adaptable for many jobs than spot, space or strip heaters.
This heating cable was developed primarily as a substitute heat source for manure for starting early plants from seed in hotbeds, but it proved so useful a device that we're now selling more footage for industrial purposes than for the original application.
You simply take a standard 60 or 120 ft. length of this Rockbestos Heating Cable, wrap it around a drain pipe or a valve, put some lagging over it to conserve the heat, hook it up to a 115 or 220 volt line and there you have it. You can control it manually or with an inexpensive thermostat.
But wait! Instead of my describing this, I'm just going to ask you to read excerpts from some of our sales reports. They'll give you the idea and may suggest ways of using the cable to prevent pipes from freezing in the winter and to keep sluggish fluids flowing.
. . . "sprinkler pipes in a wet pipe system located in unheated portions of the plant are kept at non freezing temperatures with its even application of mild beat" . . .
.. . "soap is kept at the right consistency to flow smoothly through the conveyor pipes, by winding them with cable sufficient to keep them at the correct heat" .. .
. . . "candy manufacturers are using it because it keeps chocolate pipes flowing steadily" ...
/
RBB 00373
ROCKBESTOS INDUST
. . . "Mr. -----------------. engineer for the com pany, an amateur movie photographer, coiled the heating cable in his developing tanks to maintain the solution at proper temperature." NOTE: In heating liquids, engineers have told us that strip heaters are sometimes unsuitable because the solution becomes too hot immedi ately at the heater, sometimes to the extent of breaking down chemically. The heating cable overcomes this weakness because of its low (about 7) wattage per foot.
. . . "water and sewerage pipes in certain sec tions of the plant were wound with heating cable and covered with lagging for retention of heat. This has prevented freeze-ups and elim inated costly maintenance under the most ad verse conditions" .. .
... "a roundhouse foreman on the-------------Railroad got disturbed when he discovered his men putting in a lot of time around a barrel of journal grease. When they told him that the cold weather stiffened the grease so much that it was almost impossible to remove it. he got busy. Fresh barrels had a 60 ft. coil of heating cable sunk in the grease before it got hard . . . now it's always `pretty soft' "...
. .. "Nursery men and florists use heating cable instead of manure. The cable gives a ther mostatically controlled minimum temperature, impossible to get with manure, resulting in faster and more uniform growth, a greater per centage of rooted plants and a sturdier root system. In cold frames it gives definite assurance against freezing plants" ...
. . . "and you can even shovel snow with it!" . . . Industrial Heating Cable was embedded 1" below the surface of a concrete walk, laid out to a 40 watt per sq. ft. consumption. This provided an estimated temperature rise of about 20. which eliminated snow and prevented ice formation at temperatures as low as 15 F. above zero.
---AND A FEW SUGG
RBB 00374
UAL HEATING CABLE
s '/
... "a steel mill uses it around roll-necks to prevent the lubricant from congealing" . . .
. . . "one of the biggest paint and varnish manufacturers in this territory uses it to keep production flowing smoothly through the con veyor pipes" . . .
. . . An engineer in the -----------------Chemical Co. said "this line is used to convey molten sul phur and is wrapped with Rockbestos Heating Cable between pipe and insulation (see arrows below) to prevent the sulphur from cooling in transit. At present we are using four of these installations of substantially the same design and construction to good advantage. The tempera ture of the sulphur is controlled by means of a thermostat used with the heating cable" .. .
. . . "This picture will show you how one of the electric utilities engineers used our heating cable. A conservator type transformer acted up in cold weather when the oil congealed and then there was always the possibility that the con densate would freeze. He got around it by wind ing the cable around the pipes connecting the conservator tank to the main tank (see arrows above) and covering it with lagging. Now he has an all-weather installation" . . .
. . . "low temperatures and condensation caused the pneumatic tube messenger system of a large packing house to get balky. A few ap plications of our heating cable around the trouble spots eliminated these annoying un scheduled stops" . . .
. . . "this manufacturer makes his positive dry print developing machine turn out better prints by building into it a steady, evenly dif fused heat with our Industrial Heating Cable."
. . . "Molasses doesn't run slow in January in this feed mill. Four 60 ft. lengths of cable coiled around suction pump inlets develop 1600 watts and make pumping easy" . . .
LSTIONS FOR ITS USE
RBB 00375
innyi'iV- 'iVi'* i
'
. . . "The --------------- Power Co. tried compressed air and other methods of keeping the trash racks in their hydro dams free from needle ice without complete success until we suggested our heat ing cable installed in pipes. It worked so well last year that they intend to adopt the method as standard and make similar installations in all their dams this winter." (Reference on request.)
... "a big forge plant uses it on oil feeder lines to keep fuel oil fluid enough to permit quick starting of furnaces" . . .
. . . "an oil company uses it to prevent freezing of 6" water valves" . . .
We could tell you more, but this is one of those things that goes on and on. so we can only hope that these few stories of widely diversified types of installations will suggest ways in which you may use Rockbestos Industrial Heating Cable to prevent freezeups, reduce maintenance expense, supply an even and controlled heat where it is needed, or to keep liquid production flowing more smoothly. And you can do it for pennies because the cable costs only 5 to 7 cents a foot in small quantities!
INSTALLATION INFORMATION
Standard heating cable stocked in 60 ft. and 120 ft. lengths; 60 ft. for 115 volt circuits. 120 ft. for 230 volt circuits. Also supplied in continuous pieces of any length.
Resistance approximately 1/2 ohm per foot. Current consumption approximately 3.8 amps for 60 ft. lengths on 115 volts or a 120 ft. length on 230 volts. Wattage developed approximately 400 for a 60 ft. length on 115 volts; 800 for a 120 ft. length on 230 volts. The 60 ft. and 120 ft. lengths can be shortened if necessary, but the recommended limit is approximately 7 watts per foot, the temperature naturally varying with particular conditions of installation such as how fast heat is taken off cable, etc. Our Engineering Dept, will be glad to advise in your particular heating problem.
CONSTRUCTION SPECIFICATIONS
Size: No. 19A.W.G. Conductor: Nickel Chromium Bare Diameter: .036" Resistance: .5015 ohms per ft.
Pelted asbestos insulation: Lead sheath: Finished diameter: Net weight per M feet:
.040" 4/64" thick .245"
198 lbs.
Approx.
2000 ft. and over
$.05 per ft. ($51.50 per M)
NET PRICES
600 to 1999 ft.
$.05*4 per ft. ($55.10 per M)
240 to 599 ft.
$.0614 per ft. ($62.50 per M)
Less than 240 ft.
$.07 per ft. ($69.80 per M)
Why not check up on what you have to protect from freeze-ups or keep fluid, and make out your requisition for a trial order of this heating cable?
Specify "Rockbestos No. 19 Industrial Heating Cable" and mark your order for the attention of our "Mail Sales Dept."
Thanks for your time--and I'll hope to see your order in the next few days.
Cordially yours.
RINT6D IN r. S A
Rockbestos Products Corporation
RBB 00376