784 CHAPTER 56 1960 Guide sure rise, if the heating continues for any length of time, may result in rupturing of the tank. If the tank water is not confined, continued heating would, of course, cause no increase in pressure beyond ordinary line pressure. However, the temperature would continue to in crease. If this should happen at elevated temperatures, the flashing of the water into steam might cause a serious tank explosion. In order to guard against the development of excessive pressure inside a hot water storage tank (owing to the ther mal expansion of the water), it is customary to install a spring-loaded pressure-relief valve which is set to open at a pressure about 20 pm higher than the normal line pressure. The amount of water discharged by any pressure-relief device is usually quite small, since it takes only a small quan tity of water to relieve any pressure rise due to the thermal expansion of the water. The rate of discharge should be such as to limit the pressure rise for any given heat input to 10 percent of the pressure at which the valve is set to open. For any given installation, the discharging capacity should be in excess of the water to be discharged by the heater. The heater discharge in gallons per minute may be computed by Equation 5: Qm 0.000056 (5) where b is the heat input of heater in Btu per minute. To prevent danger of overheating, temperature-relief de vices should be used. One type of such a device has a fusible plug of metal which melts at about 212 F. The hot water then runs from the opening until the device is serviced. A better type of relief device is one which incorporates a bellows or bimetallic disc, which opens at a temperature of 210 F and closes when the temperature drops to approximately 160 F. Another type of safety device is a fuel cut-off switch or valve in which a fusible plug is melted by excessive water temperature. The fuel supply is cut off until the fusible plug is replaced. Combination temperature and pressure relief valves also are available. The capacity of temperature-relief devices may be calcu lated by Equation 6: Q. - 0.00086 (6) where Qm and 6 denote the same quantities as in Equation 5. Pressure-relief valves should be installed in the cold water line near the tank, on the tank ride of any shut-off device, and out of contact with the hot water in order to prevent excessive corrosion and Hma deposit on the valve seat. Temperaturerelief valves, in general, must be installed at the point of maximum water temperature, usually in the tank, but if in stalled in the pipe, must be on the tank ride of any shut-off device. SOLAR WATER HEATERS Solar heaters utilize the energy of the sun for heating wa ter. The successful operation of such heaters requires the availability of sunshine practically every day in the year, which has limited their use to Florida and the southern por tions of California. When supplemented with some other means of gas, coal, or oil water beating, solar heaters may be used in climates where sunshine may be more or less inter mittent. They have been used in summer homes as far north as Chicago. When properly installed and proportioned, solar water heaters render satisfactory service, especially in cli mates where the outdoor temperatures are high and extremely hot water is not necessarily desirable. Such installations con sist essentially of a storage tank, heating coil, and hot box. The coil is installed in the hot box, and is arranged to circulate water to and from the storage tank. The advantage in the use of this type of heater is the fact that it requires no fuel. The same materials should be used for the coil, circulation lines, and tank. A copper coil is more efficient in absorbing heat in the box, but galvanized iron or steel may be sub stituted, depending on the local water conditions, cost, and other considerations. The storage tank must be able to store sufficient heated water for the night period of about 16 hr when the coil is not functioning, or is operating under such poor sun condi tions as to make its heating effect negligible. Due to the fact that the no sun period includes the night period when little or no hot water is used, an available storage of 50 percent of the average daily usage is considered adequate. Since about 25 percent of stored hot water cannot be drawn out of a storage tank before the incoming cold water reduces the tem perature of all of the water in the tank to an unsatisfactory point for usage, the equation foT calculating the storage ca pacity of the tank becomes: ,, Q* X 0.60 S " ~0.75~ 0.666Q, (7) where S =* storage capacity of tank, gallons. Qi -- average daily usage, gallons. Thus, for a family of four persons using an average of 40 gal of hot water per (person) (day), the size of the tank would be 4 persons x 40 gal x 0.666 or 106 gal, and the nearest standard size of tank would be used. The tank should be well insulated to prevent undue loss of heat during the 16-hour period when the coil is inoperative, and it should be located as high as possible in the building (under the peak of the roof if such exists) so as to secure a maximum circulation head from the coil. The hot water supply line to the house, as shown in Fig. 15, is connected to the top of the tank and serves to vent the air from the tank through the hot water faucets as fast as it accumulates. The coil should be of the return-bend type (square or slightly rectangular in form), and should have the pipes run ning east and west, with the coil on the south ride of the building where it can receive the full sun effect all day lung without shadows from the building itself, or from the ad jacent obstructions such as trees or other structures. The coil should be placed as low as possible in relation to the storage Water Services 785 Table 18 .... Suggested Solar Heater Design Data* Dtfl0 Horn Bec 00 Sole of 30 Gat par Day par Sanaa 8otad aa Sato of 40 Got par Day par Sanaa No. of occupants in residence..................... I 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Hot water used at night, gal per person.. 15 15 15 15 15 15 15 15 20 20 20 20 20 20 20 20 Hot water used at night, gal total............ 15 30 45 60 75 90 105 120 20 40 60 80 100 120 140 160 Retained in tank, 25 percent, gai.............. 4 8 11 15 19 23 27 30 5 10 16 20 25 30 35 40 Tank capacity required, gal........................ 20 40 59 75 94 113 130 150 25 50 75 100 125 150 175 200 Sot water used during day, gal................. 15 30 45 60 75 90 105 120 20 40 60 80 100 120 140 160 Total water to be heated: Gal per 8-hr period..................................... 35 70 104 135 169 203 235 270 Gal per hour.................................................. 4.5 9 13 17 21 26 29 34 45 90 135 180 225 270 315 360 6 12 17 23 28 34 39 45 Copper coil required: Surface area, sq ft....................................... 25 50 75 100 121 ~ 145 168 192 32 64 96 L2S 160 192 224 256 Equivalent length 1-in. coil, ft.............. 100 200 300 400 484 580 664 768 128 256 384 512 640 768 896 1024 Box size: Area, sq ft...................................................... Width, ft......................................................... Length, ft....................................................... 25 4 6 50 75 100 121 145 168 192 32 64 96 128 160 192 224 256 678 9 10 10 11 4 6 8 9 10 11 12 12 8 11 12.5 13.5 14.5 16.5 17.6 8 10 12 14 16 18 19 21 * Son Effect end the Deafen of Solar Heater*, by H. L. Alt (ASHVE TiAKucnom, VoL <1, 1S35, p. 131). tank level, such as on a porch roof, the roof of a one-story extension or, if necessary, even on the ground. Both the coil and the circulation lines should be designed to facilitate the circulation flow as much as possible, using long-radius copper fittings or recessed galvanized-iron fittings to match the materials of the coil, circulation lines, and tank. The coil should be inclined, as shown in Fig. 16, so that the north end is raised above the south end to secure an w-ngle with the horizontal of about 53 deg. This will result in the inlet end of the coil being on the south ride (or bottom), and the outlet end being on the north ride (or top). This will satisfy condi tions along the 30-deg N latitude, which includes the por tions of Florida and Southern' California where these heaters are most frequently used. The hot box is usually constructed of wood on the four rides and bottom, and is insulated. Glass are placed over the top of the box which should be airtight. The interior sur faces should be painted white to reflect the heat, while the coil should be painted black to absorb the heat. The box need not be deeper than necessary to house the coil and to protect it from the weather. The addition, on the bottom of the box, of a light gage copper plate to which the pipe of the coil is soldered for good metallic contact, will add to the amount of heat received by the coil, due to the fact that this plate will receive all of the sun's rays which fail to directly strike the coil. The beat from this source is transmitted to the coil through the plate rather than from the heated air surrounding the coil. Other wise, only part of the heat enters the coil, the balance being transmitted through the glass. Design data given in Table 17 may be used with judgment in selecting the size of solar heater coil and box for a particu lar application. These data are based on consumptions of 30 and 40 gal of hot water per- (day) (person). DOMESTIC HOT WATER BY HEAT PUMP Hot water may suitably be obtained by using a heat-pump installation. The hot water heater may be either a heat exchanger installed just ahead of the compressor of a heat- fig. 16....Solar Heating Coil Inclination fig. 17.... Heat Pump Arrangement for Hot Water Supply