Document ymGjQx8y7VwDK0aeVGVX3wn1D

American Society of Heating and Ventilating Engineers Guide, 1929 days for the season in question and the average degree-davs as shown in Table 3. Table 3. Duration of Heating Season City Atlanta................ Boston.__............. Buffalo...... .......... Cincinnati.......... Cleveland............ Chicago__............ Dallas................... Denver................. Detroit................. Jacksonville........ Kansas City....... Minneapolis........ New York.... ....... Oklahoma City.. Pittsburgh........... San Francisco__ St. Louis.............. Philadelphia........ Seattle.... .............. Washington......... Degree--Days for Heating 2880 6055 6750 5302 6096 6007 2455 5880 6202 1080 5302 7953 5303 3827 5327 3450 4583 4950 5156 4562 PROPORTIONING RADIATION The charts of Figs. I and 2 graphically represent the number of cubic feet of gas per square foot of radiation for the heating season in any climate, the climate being expressed in degree-days, and are applicable to any heating condition in the United States. These charts give very close estimates when the radiation is proportioned to maintain a maximum inside temperature of 70 deg. and when that temperature is maintained. It seems hardly possible to formulate a general rule to cover the esti mating of fuel consumption when temperatures other than 70 deg. are to be maintained; at least to formulate a rule based upon the ones just given. For example, the maintenance of a temperature other than 70; let us say 55 deg.; would amount to cutting a much different proportion off. the heating season in San Francisco than would be the case in some other locality, for example, New York. It would seem, therefore, that in the absence of sufficient data on which to base rules for estimating fuel consumptions in those cases where temperatures other than 70 are to be maintained with the building to be heated, it would be safest to handle each case individually, strictly according to its own peculiarities. A suggested procedure would be to examine the weather reports for the locality in question, determine the difference between the average outdoor temperature and the temperature to be maintained in the heated spaces for each week during the heating season, and then calculate the actual heat loss for each of the weekly periods taken. The total loss for the heating season; which would of course differ in length from the usual heating season, which is based on the maintenance of an indoor tempera ture of 70 deg.; divided-by an assumed year-around efficiency for the entire heating plant, which could safely be taken as 75 per cent; would 242 Chapter XIV--Heating with Gas give a very fair estimate of the annual fuel requirement expressed in g.t.u. to be supplied to the gas-burning appliance. CROSS-CONNECTING COAL AND GAS BOILERS Quite frequently, when a customer already has a coal boiler in his home, it is sometimes expedient to leave the coal boiler in place, and to cross-connect the gas boiler with it. Where gas heating is new to the community, it produces a more secure feeling in the customer's mind when putting in gas-fired house-heating equipment, if he knows that he can burn coal at any time he has occasion to. In hot-water heating systems, it is necessary to valve off the return pipes on the coal boiler, which prevents circulation through the latter when the gas boiler is in use. Since the gas boiler holds comparatively little water and is almost always insulated, no valves are needed on the return pipes to the gas boiler. Hence, by opening the valves on the coal boiler, it may be operated independently or in conjunction with the gas boiler. For steam or vapor installations, it is necessary to vajve off all the returns and flows on each boiler unless the gas boiler is set so that the water line in both boilers is at the same level, in which case it is necessary to valve off only the coal boiler to prevent the heating of the water in the coal boiler when it is not in use. The gas boiler should be set as close to the coal boiler as practicable, and the flows and returns should cut into the flows and returns of the coal boiler as near to the latter as possible. LARGE BUILDING HEATING COSTS The foregoing material on the estimating of heating costs when gas is used as the fuel is somewhat more applicable to residences than it is to large buildings or to buildings that are used for other than residential purposes. The use of specially designed gas boilers for large installations, such as office buildings, department stores, and other buildings of a similar nature, is increasing so rapidly that it is possible to give fairly accurate data covering several phases of these installations. In com paring the true cost of heating a large building of a commercial, nature with gas, as opposed to other fuels, there are a number of items that should be considered in addition to the bare fuel costs. Rental value of the floor space occupied by the boiler installation and of the space re quired for fuel and ash storage, may have a strong bearing on the true cost of heating. When gas is burned the added feature of cleanliness resulting from the elimination of coal delivery and ash removal may add materially to the attractiveness of the building. It is difficult to evaluate the reduced necessity for redecoration when gas is used, because the frequent changes in tenancy encountered in this class of building always necessitate redecoration. There are many cases however, where this factor, has a tangible value. The supervision of a gas-heated plant is reduced to a minimum. The methods of control produce a uniform temperature at all times, with the minimum requirement of making sure that the pilots are operating and that the temperature controls are set at the proper joint. It is often 243