Document ymEzozGY70qLrnr8dXx96yG74
'WF
Fans and Ventilating Equipment
Bayley Blower Company
784 Greenblish Street Branches in Principal Cities
Milwaukee, Wis,
BUILDERS OF HEATING, VENTILATING, COOLING, PURIFYING, HUMIDIFYING AND AIR WASHING EQUIPMENT: EXHAUST AND DRYING APPARATUS, MECHANICAL
DRAFT AND BLAST. FANS AND BLOWERS OF ALL TYPES
BAYLEY PLEX1FORM FAN:
Used to supply air for heating systems or heating and ventilating systems for manufacturing and process industries, for 'drying systems, or lor forced or induced draft systems for boiler plants.
The rlexiform Fan is suitable for han dling cool or warm air, as well as high or low temperature gases. It will deliver the maximum quantity of air in applications where medium or low pressure is required.
For applications where space is limited, or where economy of power is desirable, this fan is especially recommended.
Hie fan wheel, of distinct Bayley design, has great strength without excess weight. Due to its reinforced.construction and equal distribution of stresses, vibration is reduced to a minimum. Crystallisation of parts, so called, is thus avoided. Large and unobstructed inlets and outlets, and the absence of arbitrary air cut-offs, insure free and noiseless delivery of air.
Bayley Plexiform Fans are furnished in either single or double width wheel types of any required housing construction, and discharge positive sleeve or bau bearings as specified.
TURBO AIR WASHER AND HUMIDIFIER:
The Bayley Air Washing System is of fered for all public and industrial buildings, where a central system of air washing and humidifying is desired.
Competitive air washing and humidify ing equipment requires frequent Honing of the spray nozzles, as the particles of dirt in the recirculated water The Bayley Turbo Air Wother Show rapidly clogB the on-. ing Turbo Atomizer and Eliminator fices.
The Turbo Atomiser used in the Bayley Washer, produces a' steady, fine spray. Water at low pressure is delivered to the center of a rapidly revolving cone-shaped rotor provided with atomising pins set in its periphery. This atomiser cannot clog, requires very little attention, and will operate successfully under low water pressure. The spray is uniform, and there are never any spaoes in the Air Washer that are not completely filled with a fine mist. BayleyTurbo AirWasher and Conditioners may be used for washing, cooling, humidifying, or dehumidifying, as required.
CHINOOK HEATING,SECTIONS:
middle of the tank without breaking steam connections or taking down a single section.
Shipped assembled in smaller sixes, and knocked down in the larger units. May be installed in horizontal or vertical position.
BAYLEY TYPE EXHAUST FAN:
An exhaust unit for handling refuse from sawmills, planing mills, cotton gins, textile mills and wood working plants, designed for high efficiency at moderate speed. Its outstanding features are the blast wheel which is built up from an ac curately machined and balanced center, insuring well balanced wheel and malring replacement of accidentally broken blades a simple matter.
DISCF1N HEATERS:
Discfin Heaters are constructed along
the lines original with the Bayley
Blower Company, as described under
Chinook Heating Sections.
The Discfin unit illustrated is
particularly adapted to use in offices
and entrances to buildings, as well as
the main portions of industrial plants.
It may be connected to the outside air,
and thus will ventilate as well as heat
the space in which it is installed.
The beaters are sturdy, efficient,
easily installed, and occupy no valuable
floor or wall space. They require no
special structure to carry them, and
they may be attached to walls or col
umns, suspended from the floor above, or from the heating main, as circum stances will permit.
Single Unit of the Sup ported Type with A..ir
It is not necessary when this heater Lonnerfwn from the
is used, to recirculate air at room tem-
rloor lane
perature. Air directly from out of
doors may be led to the unit, thus
it a ventilating as well
as a heating unit. The entire unit is testa! to a working pressure
of 80 lb.
The Bayley Blower Company offer in addition to the Discfin
described, larger sixes of industrial unit heaters. The well-known
B.tiu. Heater is popular in railroad roundhouses and shops. The
LC.U. Heater is also an industrial unit of somewhat tighter con
struction, which is adapted to use in industrial buildingB of all
sorts.
The Chinook Section is used
with fan type heating, ventilat ing, and drying systems. It circulatee either nigh or low pres sure steam by gravity or under a vacuum. The heater may also be used to circulate hot water for heating purposes, or cold
water for cooling purposes. The Chinook base is of grey
cast iron, having walls of suf ficient thickness to withstand a
working pressure of 175 lb. per sq. in. The casting is divided into two chambers by a horizontal partition. Steam enters the lower or steam chamber from which it rises through %-in. wrought pipes, which are located within the 13^-in. wrought pipes leading from the upper chamber.- Thus the steam in the
steam chamber passes up through the small pipes (which are open at the top) into the larger pipes, where condensation takes place, tiie water and air falling into the upper chamber and draining away through the return outlet. Each tube is evenly heated
through its entire length, and air binding cannot occur. The Chinook is the only heater in which a leak can be repaired in the
BAYLEY CHINOOKFIN HEATING SECTIONS:
The Chinookfin heater embodies the same successful principles of construction as the original Chinook, except that the radiating dement is copper tubing, carry ing extended copper-fin surfaces. The manner of attaching the fins so as to re main tight under all conditions and tem perature changes is unique and very efficient.
Each pipe is separate; individual, and independent; expansion and contraction of any one pipe does not affect the others; 'no rigid connections, return bends, nipples, of elbows, to be racked out of shape by unequal expansion and contraction. This construction permits continuous and in numerable cycles of expansion and con traction without crystallization of materials and resulting damage.
The Bayley Chinookfin Heater is as safe for tempering coil service as for re heaters--a remarkable feature of this heater.
Write for Bulletin, No. 29-C which describes it in detaiL
638
Fans and Ventilating Equipment
The Buckeye Blower Company
Main Office and Factory
400 Dublin Avenue, Columbus, Ohio
Atlanta, Ga. Baltimore. Md.
Boston, Mass. Buffalo, N. Y. Chicago, III. Cleveland, Ohio
Branch Sales and Service Offices
Dallas, Texas
Indianapolis, Ind.
Denver. Colo.
Kansas Citt, Mo.
Detroit, Mich.
Los Angeles, Calif.
Grand Rapids. Mich. . Milwaukee, Wis.
Harrisburg, Pa.
Minneapolis, Minn.
Hempstead, N. Y.
Newark, N. J.
New York Citt Philadelphia, Pa. Pittsburgh, Pa. Portland, Ore. Richmond. Va. St. Joseph, Mo.
IN CANADA: TORONTO, ONTARIO
St. Louis, Mo. Salt Lake Citt, Utah Seattle, Wash. STRACU8E, N. Y.
Youngstown, Ohio
Manufacturers of BUCKEYE Heating and Ventilating and Air Conditioning Apparatus
The Buckeye Heatovent has been developed for use in School
Rooms and places where quiet running, temperature control,
quick heating, and positive ventilation are requisites. This
machine is equipped with the oval tube copper radiator which
will not burst when frozen.
';
The Buckeye Thermovent has been developed for larger installations requiring from 2000 to 5000 c.f.m. as churches, auditoriums, garages. Horizontal type for ceiling hanging, vertical type for floor setting. Equipped with or without mixing dampers.
The Buckeye Giant Unit Heater was especially designed and developed for Airplane Hanger and large Industrial Building Heating. Capacities up to 20,000 c.f.m. and 2,000,000 B.t.u.
The Buckeye Thermofan is a propeller fan type of unit for smaller industrial work-rooms.. Can be used for fresh air. supply or recirculating jobs, equipped with or without ducts to floor.
Multiblade Fans for heatipg, ventilating, . drying, dust removal and allied uses in all sizes up to 100,000 c.f.m. and up to 6 in. static pressure.
Ozonation and humidity treatment available for all unit applications. Engineering service available in all branch offices.'
639