Document ykDpjX0EMkgOqQdw12NBddkgE
Willard Storage Battery Company
MAIN OFFICE AND FACTORY 246-586 E. 131 s t ST.
Cleveland, Ohio
Feb. 14, 1945
Robert A. Kehoe, M. D. University of Cincinnati Kettering laboratory Eden Avenue Cincinnati, Ohio
Dear Doctor:
T.'e have your letter of Feb. 7 and the analyses of
This man's work was dene in one or more of our Forming rooms, the work consisted cf taking bundles of about twenty pasted pieces from a dolly, placing them on the edge of a Forming tank and then brushing the plate lugs on both ends of the piece `with a wire brush. These pieces consisting of two plates^are then dropped into slots, in the Forming tank.
,Dust counts taken in Forming rooms while this work was in process
showed the following results in mg. per 10 c.m. of air: 4.94,
14.7 15*7 and 23.5* These readings, we admit, indicate concen
tration and especially dangerous concentration when it is known that the room is exhausted through the roof.
Because of T,rar orders we are forced to use this process of tank Forming plates and as yet no method of eliminating the hazard has been evolved.
7<e investigated the time elapsed between the last day of exposure and the date of sampling and found that on January 20 at 3:30 P.M. , he had a seven day week, he did not work Sunday, January 21 and worked January 22 for nine hours up to :Q0 p.y. Samples were taken on January 2 at about 2:00 P.t/.
7;'e hope this gives you the information that was lacking in our earlier letter.
Very truly yours.
VilLLARD STORAGE BATTERY COL'iPANY
'.'VBHilvIE
B. Hutchinson, M
VICTORY
BUY
VK'TEO TATS <
WAR
D.