Document ygddzymBm0zyybQ89nxKD1wV

Air Conditioning, Automatic Heating Systems he MjyER Furnace GbMPANy PEORIA.ILLINOIS Manufacturers of Domestic Heating and Air Conditioning Units for Coal, Gas and Oil Burning Branches and Distributors Kansas City, Mo. Omaha, Neb. Green Bay, Wis. Pittsburgh, Pa. New Orleans, La. Detroit, Mich. St. Louis, Mo. San Francisco, Calif. Des Moines, Iowa Minneapolis, Minn. The WEIR Conditioned*Air Unit for coal burning, built around the famous WEIR Steel Furnace, is a complete unit for con ditioning the air in the home during the heat ing season. Equipment includes automatic humidifier, renewable filter, centrifugal blower and automatic damper and blower controls. WEIR Conditioned A ir Unit WEIR Gravity Heater No. Grate Surface CSq Ft) Ratio Htg. to Grate Surface Smoke Outlet Diam. On.) 621 1.26 624 1.78 628 2.32 630 3.08 633 3.82 636 4.74 540 6.25 544 7.60 41.2 33.9 29.2 26.4 22.7 19.4 19.3 18.5 9 10 10 10 10 10 12 12 Gravity Circulation Fan Circulation Casing Dimen. Round Rect'lar (In.) (In.) Rated Output At Reg. Pipe Area (Btu.Hour) (Sq In.) Casing Dimen. (In.) Air Rated Output Delivery at register (CFM) (Btu.Hour) 48 52 . 47x50 54 50x52 58 54x56 65 56x64 67 56x66 54.400 73,600 94,100 119.000 138.000 160,000 400 541 692 875 1015 1180 47x90 . 50x99 54x103 56x110 56x118 60x106 64x114 1200 1600 2000 2300 2700 5000 92,000 118,000 148,000 172,000 200,000 3I6'000 WEIR Oil Fired A ir Conditioner The WEIR Oil-Fired Air Conditioner does a complete job of winter air conditioning. Designed for oil fuel and forced circu lation. Features include quiet operation, dependability, safety, long life, modem appearance and high efficiency. The MEYER Gas-Fired Air Conditioner provides complete winter air conditioning. Modern in appearance, compact and efficient with heavy gauge, welded steel, gas-tight heating section. Equipment includes automatic humidifier, renewable filters, centrifugal blower and fully automatic controls. No. Input Output Burner Bonnet (Btu/Hour) (Btu/Hour) Vent Diam. (In.) Dimensions W. L. R (In.) (In.) (In.) Air Delivery Aln.SP. (CFM) Size -(HP) < 200,000 275.000 350.000 WEIR Oil-Fired Air Conditioner 150.000 205.000 265.000 7 48 65 48 7 56 65 48 7 63 65 48 1700 2300 3000 1/4 1/3 1/2 MEYER Gas Fired Air Conditioner B-l B-iy, B-2 B-3 B-4 B-5 90,000 135,000 180.000 270,000 360.000 450,000 MEYER Gas-Fired Air Conditioner 67.500 101,250 * 135.000 202,500 270.000 337,500 4 20 53 42 5 27 60 44 7 40 53 42 8 60 53 42 9 80 53 42 10 100 53 42 1000 1500 2000 3000 4000 5000 1/6 1/4 1/3 . 1/2 3/4 3/4 . MEYER Gravity Gas Furnace C-100 C-12Q C-150 100,000 120,000 150,000 75,000 90,000 112,500 5 6 6 38 42 42 38 42 42 60 67 67 Complete descriptive literature, including data on Summer cooling, upon request MEYER Gravity Gas Furnace The MEYER Gravity Gas Furnace--Efficient--Economical --All steel, welded heating section--large heating surface-- A.G.A. approval. 866 Air Conditioning, Automatic Healing Systems Kelvinator Division of Nash-Kelvinator Corporation SUMMER AND WINTER AIR CONDITIONING Factories in Detroit, Michigan, and London, Ontario Distributors in all Principal Cities Air Conditioning Household Refrigeration Automatic Heating Water Cooling Beverage Cooling Milk Cooling Ice Cream Cabinets Truck Refrigeration Commercial Refrigeration For Every Need of Mer chants, Manufacturers and Institutions Selecting the Most Suitable Type of Air Conditioning Installation Where a year-'round central system in stallation is out of the question due to space limitations, remodeling expense, time allotment or other factors, the following general suggestions will be help ful. Whenever possible, we urge consul tation with your local Kelvinator Air Conditioning distributor. He offers you every advantage of Kelvinator's broad experience in air-conditioning all types of buildings--his services are freely available without charge or obligation. Single rooms in residential or com mercial buildings: Water-cooled or air cooled room coolers, or type C sus pended units. . Large rooms, such as sales rooms, general offices, or manufacturing quarters: One or more CA Suspended Units, as required for capacity and air distribution, all served by a single con densing unit if practical. Or ai type CS Unit with duct distribution throughout the quarters to be air conditioned. Con densing unit may be remotely located most convenient to plumbing and electrical connections. Suites, or a separate floor of a build ing: CA units exposed, or concealed behind closet or corridor walls, served in multiple by a single condensing unit in stallation in an out-of-the-way location where plumbing and electrical connections can be arranged economically. Or a CS unit with duct distribution to each office. New construction of all types: Complete year-'round air conditioning employing CS unit and duct distribution, or individually-designed system. Consult your Kelvinator distributor. Capacity Requirements: Summerload capacity requirements depend on the type of construction of the building, exposure, amount of occupancy and traf fic, activity of occupants, heat generating equipment within the enclosure, local weather averages and other factors. Consult your local Kelvinator distributor for latest experience data on capacity requirements in your locality. Costs: Your Kelvinator distributor is qualified to aid you in determining eco nomical methods of air conditioning new or existing construction, from the standpoints of operating expense as well as initial cost. All Kelvinator Air Conditioning Units Are Provided with Contact Type Spun Glass Filters For Complete Specifications, Features and Functions of the Latest Types of Equipment Consult Your Local Kelvinator Air Conditioning Distributor See also Page 9S0 867