Document ybxx688NZe1Vwn0OLJgxYLmnn
PLAINTIW'S EXIIIWf mi07
Inter ortice
Mr. A. Clark, Safety Engineer Lanedale Electronics Plant
Personnel and Organization Staff
May 6, 1981
oc L. F. Bieler
R. M. Ruth D. Vaughn
Subjectt Asbestos and Silica Analyses, Lanedale Plant
At your request, four bulk samples and four filter samples were analyzed for
asbestos and Bilica (i.e., quartz) respectively. The results of the analyses are listed in the attached tables and discussed below:
Asbestos
All bulk samples were found to contain some asbestiform material (refer to Table 1) (i.e., chrysotile). The actual amounts ranged from 1-2 percent in the floor sweepingB (Sample nC") to 21-22 percent in sample cut from rectangular bar stock (Sample "A").
The samples were initially analyzed in the Ford Industrial Hygiene Laboratory '
using an asbestos "spot test" and the results confirmed by Clayton Environmental Associates Laboratory vising x-ray diffraction techniques.
Cyrstalline Silica Four air samples for total airborne dust were analyzed for silica content (refer to attached Table 2), and appropriate permissible exposure limits were calculated.
The air sampling results indicate that the first operator position east of the silo is not exposed to excessive silica concentrations. However, the area under the sand silo does contain excessive airborne crystalline silica concentrations and, therefore, acceB6 to this area should be restricted.
If there are any questions, contact the writer at 313-337-8955.
Jb Attachments 1
M. JAO'Brien, Industrial Hygienist Senior Industrial Hygiene & Toxicology Department Employe Health Services
SCF-FORD-3108 <5007 ^7 51
PRODUCED BY FORD
Table 1
INDUSTRIAL HYGIENE SERVICES SECTION INDUSTRIAL HYGIENE & TOXICOLOGY DEPARTMENT
_____________ EMPLOYE HEALTH SERVICES
Lansdale Plant Asbestos Bulk Samples
Sample Description
Peroent Asbestos (Ohryeotile)
Sample A - Cut from rectangular bar Btock
21-22
Sample B - Cut from rod-type bar stook
11-12
Sample C - Floor eweepingB
1-2
Sample D - Insulation in cellar
9
Samples analyzed by x-ray diffraction technique by Clayton Environmental Consultants. Also analyzed by asbestos "spot check" test by Ford Industrial Hygiene Laboratories.
DATA RETRIEVAL NUMBERS! AC 20-23
5007 0752
' PRODUCED BY FORD
INDUSTRIAL HYGIENE SERVICES SECTION
INDUSTRIAL HYGIENE & TOXICOLOGY DEPARTMENT
_____________ EMPLOYE HEALTH SERVICES
Table 2
LanBdale Plant Duraspark Area
Location GENERAL AREA SAMPLES First operator station east of silo First operator station east of silo Sand shaker near operator Under sand silo
Percent
Crystalline
Silica
21.3
10.7
6.0
67.7
Airborne Crystalline
Silica Concentration
(me/M3)
PEL**
Actual
1.23
0.39
2.19
0.20
3.33 0.42
0.69 2.70*
* Exceeds 8-hour time-weighted average permissible exposure limit
** Permissible exposure limit calculated from following equation: raL (^m3) ' it Silica + 3
DATA RETRIEVAL NUMBERS: AC 10-13
3007 0? PRODUCED BY FORD