Document ybm6ebkREY92QD1pLdOaJ2wvE
Document No. R8QP-2015 RO Effective Date 4/19/2016
EPA Region 8 402c Renovation, Repair, and Painting Rule Inspection List 1 OF 6
BASIC INSPECTION INFORMATION
Inspection Date/Time: 3/6/2023 02:10
ICIS #: 3601516609
Presented EPA credentials to person in charge and explained purpose and scope of inspection
Inspection Entry:
Entry Permitted.
Entry Denied. (Provide details in notes.) NOI signed by: G. Giozan
Firm Name:
Regulated Entity Owner Name & Contact Information:
Jenkins Services Inc.
DBA or Former Names:
Jenkins Restorations Jenkins Services LLC
Key Principal: Drew Fetterolf 3750 Centerview Dr Chantilly, VA, 20151-3200 https://jenkinsrestorations.com/
Firm Address + Contact Information (phone, website, email):
Jenkins Restorations (CO Springs location) 4250 Buckingham Drive - Suite 600 Colorado Springs, CO 80907 719-301-3061
Additional Representatives:
# Employees: Many
# Projects/Year: Many - National Presence
Type of job observed (include permit information, if available):
House fire resulting in a complete interior and exterior remodel.
Is the firm certified? Yes No
Was a certified renovator assigned? Yes No Certificate(s) on site? Yes No
Name(s) of renovator(s):
Address of Property:
Site Information Owner Name & Contact Information:
1608 E 10th Street Pueblo, CO 81001
Jonathan Cowen (NFI)
Building Type: single family residence multi-family residence child-occupied facility other
Year Built: 1921
Is the building occupied? Yes No Unknown If Yes, age of residents:
Person(s) interviewed during inspection:
Name & Title:
Contact Information:
Document No. R8QP-2015 RO Effective Date 4/19/2016
EPA Region 8 402c Renovation, Repair, and Painting Rule Inspection List 2 OF 6
Facility Name: Jenkins Services Inc.
ICIS #: 3601516609
Work Practice Requirements
What type of project is it? Interior Exterior Both (e.g. window replacement)
Is RRP work involved? Yes No
Is RRP work in progress? Yes No
All Projects
If RRP work is in progress, check the following:
Comments:
Are Warning Signs Posted? Are prohibited practices being used? Is waste properly contained?
Are windows and doors in the work area closed and/or doors being used as an entrance covered with plastic? Is the floor in the work area covered with tapeddown plastic at least 6 ft. beyond the perimeter of surfaces undergoing renovation? Are all ducts opening in the work area covered with taped-down plastic?
Are windows and doors within 20 ft. of the renovation closed? Are doors that are in use during the job covered with plastic, allowing workers to pass through while confining dust and debris? Is the ground covered with plastic sheeting extending 10 ft beyond the perimeter of surfaces undergoing renovation?
Yes No Unknown Yes No Unknown Yes No Unknown Interior Projects Yes No Unknown
Yes No Unknown
Yes No Unknown Exterior Projects
Yes No Unknown Yes No Unknown
Yes No Unknown
If the work is complete:
Cleaning Requirements
Comments:
Is the work area cleaned so that no dust, debris, or residue remains? Are all paint chips and debris collected and sealed in a heavy-duty bag? Did a certified renovator perform a visual inspection and cleaning verification? (If yes, obtain documentation)
Yes No Unknown Yes No Unknown Yes No Unknown
Basic Recordkeeping Requirements Firm provided the following records (check all that apply):
Determination that lead-based paint
present on the components affected by the renovation
The owner or tenant's signed acknowledgment of receipt of the EPA-approved lead hazard pamphlet Training certificate(s) for certified renovator(s) Documentation of training provided to uncertified workers
Documentation of compliance with the requirements of RRP Work Practice Standards
Document No. R8QP-2015 RO Effective Date 4/19/2016
EPA Region 8 402c Renovation, Repair, and Painting Rule Inspection List 3 OF 6
Facility Name: Jenkins Services Inc.
ICIS #: 3601516609
Inspection Summary - Inspector Comments and Findings
Inspector Maksimuk observed construction activity at location. A van parked in the driveway was marked with signage "Affordable Plumbing, Heat & Electrical". Maksimuk was met by a worker "G. Giozan". Mr. Giozan (sp) signed the NOI.
The interior wall framing consisted of new lumber throughout and drywall was not yet installed. Small piles and scattered construction dust/debris/paint chips were on the concrete floor that had sweep marks as to its method of collection. This debris was likely caused by removal of the old wall covering, possibly painted drywall or other type materials. There was no evidence present to assure lead-safe work practices were utilized.
One worker stated "Brucher" was in charge of this project. Another worker stated "Skyler" was in charge. Neither was on-site during this inspection.
This company goes by different names. The permit was taken out in the name "Jenkins Services Inc." At the time of this inspection, it was not known what location of Jenkins Restoration was responsible for this project. The closest location in Colorado Springs is listed on the first page of this report. There are 24 locations nationally, according to the company's website. The address and phone number on the permit are tied to the company's headquarters in Chantilly, Virginia. The RRP Firm number is listed as NAT-F1511832.
Facility Name:
Jenkins Services Inc.
Photo #: P3060653
P3060654
P3060656
P3060657
P3060658
P3060659
PHOTO LOG
Subject Front of house w/van in driveway Permit in house
Interior wall framing
Rafter System
Boarded Window from Interior
Boarded Window from Interior slightly out of focus
Time
02:14 02:15 02:22 02:22 02:22 02:22
ICIS #:
3601516609
Notes
Date: 03/06/2023
4 OF 6
Facility Name:
Jenkins Services Inc.
Photo #:
Subject
PHOTO LOG
Time
ICIS #:
3601516609
Notes
Date: 03/06/2023
AGE NK P BLA
5 OF 6
Document No. R8QP-2015 RO Effective Date 4/19/2016
EPA Region 8 402c Renovation, Repair, and Painting Rule Inspection List 6 OF 6
Facility Name: Jenkins Services Inc.
ICIS #: 3601516609
RECORD OF REVIEW Inspector
Inspector who prepared report: Christopher Maksimuk
Signature:
Reviewed by: Kristin Jendrek Signature:
Reviewer
Date report completed:
Digitally signed by KRISTIN JENDREK Date: 2023.05.15 16:30:04 -06'00'
Date:
1/3/2020 11:04 AM