Document ybY9RZGrEOpMg130n6jaojyBV

THE USE AND DISPOSAL OF ELECTRICAL INSULATING LIQUIDS SUB-COUNCIL REPORT June 1971 NATIONAL INDUSTRIAL POLLUTION CONTROL COUNCIL STLCOPCB4044657 '&0 -* &*- < ' ,' it is. w/cte// acknowledged that ~oor productfVe^dconJ ife. vancf ouradvcincing techno logy have helped to createVnS w-,;f'W^ .,-of our. environmental problems. ' Now - the sarp'e QOC r:- ^,' .' ; , 'anc/ skUls 'ivhich have produced quantitative garns.-tpi :. :;..?v7'7?^uff| -..-econoniy most he used to improve the er>virOnmefctj$ i" *! v . f /..* " - '* '- '" .*'. . ..",,. , T1!'! v ' V to:enhance the quality of our life ..... .. , :'; ' . ' ' -t . ''7'- : >.7``11 r:-- ;.'s' The'challenge which facht thishew Industrial Council an ;. ih&hpPttreifouSmess community is'complexrahd.derqh'iw ,, '. . ;. , 1 ' i * $ J, 1 -1 -,, t-' :ing.` But IhavC- no doubt it can aryd witl.be mcL.-:-.t`fi:.<- '' r' .. - . , `r-v -R^HARD 't ................... S ................> " April 9, iV "jSFk * ; > .*,. 4*f-r k \ .. r> . e-K f :^r;a-^v^ V^v. 050136 STLCOPCB4044658 THE USE AND DISPOSAL OF ELECTRICAL INSULATING LIQUIDS SUB-COUNCIL REPORT June 3971 NATIONAL INDUSTRIAL POLLUTION CONTROL COUNCIL This report has boon prepared for the Secretary' of Commerce, ll does not necessarily represent the views of the Department of Commerce or any other Government agency. STLCOPCB4044659 For sale by the Superintendent of Documents, U.S. Government Printing Office, Washington. D C. 20402. Price 25 cents. Stock Number 5254-0028 05013B2 < STLCOPCB4044660 NWaa*hti!oncnta>l.InPdCu. aPtCrlKa3r0 Pollution Control Council June 21, 1971 Honorable Maurice M. Stans Secretary of Conmerce Washington* D. C. 20230 Dear Hr. Secretary: 1 have the honor to transmit to you for the President and the Chairman of the Council on Envl ronmentel Quality a Progress Report of actions underway by Industry with regard to specific pollution problems. This Report has been prepared by a Sub-Council of the National Industrial Pollution Control Council as an Information paper. It describes the actions and presents the views of those industries most directly Involved with the particular pollution problems addressed. Such Progress Reports will be prepared by our Sub-Councils on major pollution problems confronting Industry and will be updated from time to time. Sincerely* Bert S. Cross Chai mwn Enclosure 060 1.383 STLCOPCB4044661 National Industrial Pollution Control CounoM WnCtiinglDn, O.D. 0Q83O June llj, 29?2 Dear Chairman Crocot An Chairman of the Electric and Nuclear Sub-Council oS the National Industrial Pollution Control Council, 2 have the honor i" culm! t-ting to you this report on our industry's efYort to evaluate the pollution problem caused by the discarding* oT old household appliances. Sincerely, Enelobd re 050i384 STLCOPCB4044662 SUMMARY Electrical insulating liquids (EIL), their application and disposal are studied against a background of similar information relating to pe troleum products in total. Naphthenic mineral oils are found to comprise over 80 percent by volume of the total usage of EIL. Polybutenes are second, at almost 10 percent. Thus, 90 percent of EIL are petroleum-based. Being rela tively non-toxic and biodegradable, they represent no environmental threat when subjected to conventional secondary waste treatment. Furthermore, assistance in reclaiming or proper disposal of used mineral oils can usually be obtained from the suppliers of these products. The third largest-volume EIL group is the askarels, or polychiorobiphenyls. This group has some toxic properties and contains mem bers which have recently become suspect ecologically. Accordingly, the report contains recommendations regarding the control and dis position of askarels. INTRODUCTION This study of the use and disposal of electrical insulating liquids has been undertaken in support of the objectives of the Electric and Nuclear Sub-Council of the National Industrial Pollution Control Council. Its purpose is to examine electrical insulating liquids (EIL) for their possible toxicological or ecological Impact and, as appro priate, to provide information which may lead to advice concerning government programs which would facilitate private sector efforts directed at environmental improvement, or voluntary actions by in dustry. Specific areas of interest include pollution which may occur from the plants where EIL are used in manufacture of electrical ap paratus, and that which may occur during use or disposal. A variety of insulating liquids is used in electrical apparatus such as transformers, circuit breakers, capacitors, and high-voltage cable in order to optimize, for each application, a range of design parame ters typified by dielectric strength, losses, dissipation factor, arc and flame suppression, heat transfer coefficient, and product life expec tancy. Requirements and conditions to be met will, In a given in stance, quickly narrow the practical options available to the designer^ down to a very few or even to a single fluid. For this reason it should "i be borne in mind that, even though a particular electrical insulating / liquid may be characterized as containing the potential of contribut- | ing to the pollution of the environment, the socially-desirable and I economically correct action may lie in the adoption of precautions ] and control measures rather than in the substitution of a material j which would not perform the required function as well. ___j CLASSIFICATION OF ELECTRICAL INSULATING LIQUIDS (EIL) While there are a great many types of electrical insulating liquids used for special purposes, such as scientific apparatus, there are only a few used in such quantity as to be of economic importance to the electrical industry and relevant to the subject of national pollution control. The specifications and general characteristics of the princi pal electrical insulating liquids (hereinafter referred to as EIL) are shown in Table No. 1. TABLE NO. T: EIL CLASSIFICATION Application Combustible Transformers, Oil Circuit Breakers Capacitors, Cable Capacitors, Cable Cable, Low Pressure Cable, High Pressure Specification ASTM D1040-69 FED VV-1 -530a (Note 1.3) ASTM D2297-68 ASTM D2296-6B ASTM D1818-63 ASTM D181 9-66 Type of Material Naphthenic mineral oil Naphthenic mineral oil Polybulene oil Naphthenic mineral oil Naphthenic mineral oil Noncom b ust *ble Capacitors Transformers, Capacitors ASTM D2233-68 (Note 2) ASTM D2283-70a (Note 1.1,1.2, 2.0) FED W-l-1219 (Note 1.1, 1.2, 2.0) Polychlorinated biphenyl Polychlorinated biphenyl mixtures with diluents NOT t : 1.0 2.0 Certain grades contain small Quantities of additives which serve as antioxi dants and/or scavengers for hydrogen chloride. Commonly used materials and typical concentrations are: 1.1 dicyclo-dlepoxy carboxylatc 1.2 phenoxypropene oxide 0.14% 0.22% 1.3 2,6 ditertiary butyl p-cicsol 0.15% Certain grades contain tiichlorobenzene and/or teirachlorobcrszenc as dilu ents. 8 050138 ? STLCOPCB4044665 QUANTITIES AND USAGE OF EIL Six of the nine specifications listed in Table No. 1 are petroleum oils. Table No. 2 provides a breakdown of the principal uses of naphthenic mineral oils as insulating liquids. The information on transformer and cable usage is derived from the market estimates of several oil producers (10>.* Switchgear (circuit breaker) and capaci tor data are estimated from knowledge of one manufacturer's usage and assumed market position (TO). The second column of data in Table No. 2, field use, may be taken as a measure of the generation of waste oil during the use of the apparatus. The gallonage shown represents direct shipment of oil to users of electrical apparatus, as distinguished from manufacturers. Make-up oil is seen to be about 17 percent of the total usage of naphthenic EIL. The waste percentage varies with the class of appa ratus, being zero in the case of capacitors and highest in the case of cable. TABLE NO. 2: USE OF NAPHTHENIC OIL AS AN INSULATING LIQUID IN U.S., 1968 Apparatus Original Equiprnent Field Use Use (Make-upl 1 ransformers Switchgear Cable Capacitors 39.13 2.07 1.05 .02 Total 42.27 1.21 million 42-gal. barrels. 7.57 .40 .52 0 8.49 Millions of Gallons Total Percent of Total 46.70 2.47 1.57 .02 50.76** 92.0 4.9 3.1 100 Table No. 3 is similarly derived and presents an analysis of the total quantity of EIL according to the apparatus in which it is used. The grand total of EIL used in the year 1968 is estimated to be_62 million gallons (or 1.5 million 42-gal. barrels). The subtotal consist ing of the first two entries, naphthenic oil and polybutene liquid, is 57.26 million gallons (1.4 million barrels); thus 91 percent of the * Number* In parentheses are reference* to the Bibliography at the end of the report. U 0 50 L3 86 STLCOPCB4044666 total annual usage of Eli is petroleum based. The remainder is mostly askarels {polychlorinated biphenyls, abbreviated PCS). The chlorinated benzenes shown are not used aTonePbut as diluents for the askarels, in some applications. The category, Other, includes relatively small quantities of such materials as dibutyl sebacate and silicone oil, used in specialized apparatus of low pro duction quantities. TABLE NO. 3: QUANTITIES AND USES Of PRINCIPAL INSULATING LIQUIDS IN THE U.S., 1968 Millions of Gallons Liquid Trans- Switch- Capaci- Cable Other Total formers gear tors Liquid, % of Total Naphthenic Mineral Oil Polybutene liquid --- Askarels (PCB) Chlorinated Benzenes Castor Oil Other Total Use, Percent of Total 46.70 2.47 1.35 .79 48.84 2.47 78.8 4.0 .02 2.46 .01 .TO .01 2.60 1.57 6.20 7.77 4.2 12.5 .30 .02 32 51.06 6.20 3.81 .80 .10 .03 62.00'* 82.4 10-0 6.1 1.3 _2 100-0 .5 100.0 * 1.48 million 42-gaf. barrels. 10 050 L 339 STLCOPCB4044667 TOXICOLOGY MINERAL OILS Naphthenic oils and polybutenes are essentially non-toxic. The only reported danger is from inhalation of vapor or mists, in which the maximum allowable concentration is 5 parts per million. TOXICITY AND SAFE HANDLING OF ASKARELS (13) Inhalation At ordinary temperatures the askarels have not presented indus trial toxicological problems. The hazard of potential toxic exposure varies with their volatility: the lower-chlorinated, more-volatile ones present more of a potential problem from the standpoint of both in halation and skin contact. When askarels are used at elevated tem peratures, engineering controls must be applied, either by the use of closed systems or by effective local-exhaust ventilation together with general workroom exhaust. Vapor a? room temperature should not be breathed in a confined space, and no vapor of any askarel evolved at elevated temperatures should be allowed to be dispersed into the general workroom. Inhalation tests on animals indicate that the maximum safe con centration of vapor is in the range of from 0.5 to *1.0 milligram of the lower-chlorinated askarels per cubic meter of air. The threshold limit values (maximum allowable concentration for an 8-hour work ing day) set by the American Conference of Government Hygienists are 1.0 milligram of the lower chlorinated askarels per cubic meter of air and 0.5 milligram of the more highly chlorinated compounds per cubic meter of air. Skin Contact Schwartz patch tests on 200 volunteers showed that 54 percent chlorinated askarel was neither a primary skin irritant or a sensitizer. n 050X390 STLCOPCB4044668 Prolonged or repealed skin conlact with askarels must be avoided by the use of gloves and protective garments, because of the pos sible occurrence of a condition called chlocgcne. Although reports of this condition caused by_askarels are rare, it can be produced by excessive skin contact.-!? any askaref is spilled on the skin, the skin should be washed in the usual manner with a soap solution. A burn caused by contact with a hot askarel should be treated like any ordinary burn. Material adhering to the burned area need not be removed immediately, unless treatment of the burn demands it, in which case either soap and water or repeated washings with a vegetable oil are recommended. ECOLOGY Mineral Oils Mr. Claude E. ZoBell has written, "Mineral oils are susceptible to microbial oxidation, and certain fractions undergo autoxidation. This seems to be Nature's way of remedying oil pollution in soil as well as in sea water. ... In controlled laboratory experiments, we find that oil-oxidizing bacteria convert an average of 30-40 percent of the carbon content of hydrocarbons into bacterial cell substance or protoplasm." (14) Mineral oils and polybutenes are not known to have a long-time effect upon the ecology. In the short term, the effect of large scale spills has received considerable notice in the public press. Small amounts, in isolation, have no detrimental effects. The materials are biodegradable and exist naturally in the environment. Thus, con sideration of possible adverse ecological effects arising from the use of mineral oil in electrical apparatus becomes primarily a matter of scale, rather than properties of the oil. Also there are several well known methods of reclaiming and/or otherwise disposing of these oils satisfactorily. Assistance in this regard can usually be obtained from the supplier of the mineral insulating oil. Askarels The askarels, particularly those with more than 50 percent chlo rination, have recently been identified as a possible ecological threat to marine and bird life. The attention of the industry was called to fFTTs-subject"!n a number of published articles and specifically in a widely-distributed letter from the Monsanto Company (sole U.S. producer) under the date of February 18, 1970."(Tl) Certain askarels introduced Into eco-systems"are believed to act in a manner some what analagous to the persistent pesticides, being concentrated in successive links of the food chain. For jh-e.-shct.rt. term, effects of askarels may be kept from the envi ronment by Hmjtjng applications to closed systems (of which trans formers and capacitors are examples) and by the exercise of suitable precautions in the disposition of waste. For the longer term, the producer is working to develop modified chlorinated biphenyls which will be biodegradable. This means that even if minute quantities are released to the environment by acci dental spills the consequences will be minimal, and it will be possi ble to remove the modified materials from waste water streams in conventional secondary treatment facilities. (12) MINERAL INSULATING OIL IN PERSPECTIVE As indicated above, mineral oil is characterized as harmless to the environment if the amount released is not excessively concentrated in lime or space. The data in the Appendix were assembled to place this matter in perspective. For example, it is found that the total use of mineral oil in electrical apparatus is about 0.03 percent of all oils (Table A--1); that total field make-up is approximately 0.005 percent of all oils. Perhaps a more realistic comparison is the one drawn in the Appendix, i.e., that total usage as insulating oil is equal to a small fraction--10 percent--of the amount of used lubricating oil now being applied directly to land and stream. These comparisons do not lessen the need for prudent disposal of mineral insulating oil in accordance with accepted industry practice, but they do suggest a low action priority in the context of a national assessment of pollu tion problems in the electrical industry. It is concluded that any recommendation at this time for industry action on mineral oris would serve only to dilute the force of rec ommendations to be made in an area where greater leverage exists: the containment of askarels. RECOMMENDATIONS In view of the suspected ecological hazard presented by state-ofthe-art formulations of polychlorinated biphenyls, it is recom mended that the electrical industry employ the following guidelines in the manufacture and servicing of electrical apparatus: 1. Provision is to be made for qualified destruction of PCB waste materials, such that there will be no release of materials to the atmosphere or to ground or surface water significant from the standpoint of toxicity or adverse ecological impact. Initially, the only process which appears to meet these requirements is incineration under carefully controlled conditions. With proper adjustment of temperature, residence time in the incinerator, and other parameters, products of combustion will be limited to-HCi; COb, and HaO (in the form of sieam), The hydrochloric acid may be absorbed in a scrubber and the resultant solution neutralized with lime to form calcium chloride solution, CaCta. In the process described, the only effluents to the environment will be a plume of steam, carbon dioxide, and brine, the dis charge of which must be held to regulatory limits. 2. `All liquid waste is to be held in impervious containers pending disposal. 3. Solid wastes contaminated by PCB's are to be held in impervi ous containers pending disposal or purging. Purging may be accomplished by cleaning with proper fluids. The resulting contaminated liquids may be incinerated as above. 14 050 t393 STLCOPCB4044671 As the resull of programs undertaken since the industry was first alerted lo indications of ecological harm from PCB's, the industry has progressed a long way toward the implementation of these rec ommendations. At least two enterprises are accepting liquid wastes for incineration; facilities are being prepared for the processing of contaminated solids; evaluations of improved formulations are in progress; and a committee of the American National Standards Institute has been authorized to consider what standards may be ' ; / / appropriate, 0501394 ns STLCOPCB4044672 APPENDIX TOTAL FLOW OF PETROLEUM PRODUCTS Because a high perceniage of the total volume of electrical insu lating liquids is petroleum based, the use and disposition of EIL can best be understood against a background of the quantities of petro leum products used throughout the economy, and how they are disposed of. Table No. A-1 displays the quantities and uses of pelroleum.prod ucts in the U.S. for 1968 (the most recent year for which relatively complete data could be searched out). This Table is useful in pro viding a perspective for the viewing of the consumption of electri cal insulating oils. Item 3.12, Electrical Insulating Oil, is the total of naphthenic and polybutene EIL, and corresponds to only 0-04 per cent of "all oils." Disposal of Oils Similar to Electrical Insulating Oils Lubricating oil (Item 3.7 of Table A-1) was chosen for a compara tive study because of its similarity to electrical insulating grades of petroleum oil. Although no national study has been made, data are available (3) from which a reasonable estimate can be formed of what happens to lubricants throughout their life history, on a nation-wide scale. Lubricants may be classified conveniently in two groups: automo tive and industrial. Table No. A--2 is an estimate of the usage, waste generation, and disposition of automotive lubricants throughout the country, and Table No. A--3 presents similar data for industrial lubri cating oils. A large portion of the waste generated is collected by scavenging firms, and the fate of this portion is indicated in Table No. A--4. Table No. A-5 summaries the results of the investigation of lubricating oil waste practices. It will be noted that a little over half of all lubricating oil ends as waste, and of this half, more than half is dumped on the ground in one way or another--as locally disposed waste, as road oil, in town dumps, etc. 16 0501395 STLCOPCB4044673 The concern of the petroleum industry for this situation, and the vigorous steps being taken to evaluate its effect and to devise ameliorative procedures, where indicated, is the subject of another study. See Final Report of the Task Force on Used Oil Disposal, American Petroleum Institute (9). For the purpose of the present study, it may be pertinent to note that the total usage of petroleum-derived insulating oils 0.4 million barrels) is equal to one-tenih of that portion of waste lubricating oil being dumped on the ground or sewered, according to available estimates of current practices. 0501396 STLCOPCB4044674 TABLE NO. A--1 QUANTITIES AND USES OF PETROLEUM PRODUCTS Use Category ' IN THE U.S., 1968 Millions of 42-gallon Barrels Kero Distil Resid* sene late ual Gasotine _FJuoetl, Other Total Per cent 1.0 Heating and Energy Conversion 1.1 Electric Utilities 1.2 Healing 1.3 Industrial 1.4 Oil Companies 13 Ofi H'w'y Diesel 1.6 Mili. icxcl. jet) 1.7 Fuel for all other 76.2 26.7 3.0 512.D 45.8 9.4 49.5 12.6 12.6 185.0 173.0 135.7 39.3 35.0 8.3 188.0 761.2 181.5 48.7 49.5 47.6 47.6 Total 102.9 644.9 576.3 0 0 0 1324.1 27.0 2.0 Transportation 2.1 Railroads 2.2 Highway Diesels 2.3 Motor Vehicles 2-4 Piston Aircraft 2.3 Jet Aircraft 2.6 Ships bunk'd in U.S. 84.1 127.3 4.3 1925.4 30.6 349.4 18.2 87.6 88.4 127.3 1925.4 30.6 349.4 105.8 Total 0 229.6 91.9 1956.0 349.4 O 2626.9 53.6 3.0 Material Conversion and Other 3.1 Liquified Gases 3.2 Still Gas 3.3 Asphalt 3.4 Potrochem. Feedstocks 3.5 Coke 3.6 Ethane, Ethylene 3.7 Lubricants 3.8 Spec'! Naphthas 3.9 Not Elsewhere listed 3.10 Rond Oil 3.11 Wax 3.12 Elec. ins. Oil 330.6 149.8 141.2 330.6 149.8 141.2 92.9 76.3 55.2 48 5 27.0 92.9 76.3 55.2 48.5 27.0 16.4 7.1 4.4 1.4 16.4 7.1 4.4 1.4 Total <4.0 Grand 7 ola/ 00O 0 0 950.8 950-8 19.4 102.9 874.5 668.2 1956.0 349.4 950.8 4901.8 100.0 The basic reference for the fuel oils is (4.2) (see BIBLIOGRAPHY): for gasoline and jet fuel (a biend of gasoline, kerosene, and distillate). (6); "Other," <G). (4.4) and (ID). Some figures from other sources- have-been adjusted to yield totals in "final summary," refer ence (4.4). 18 0501*9? STLCOPCB4044675 TABLE NO. A-2 LUBRICATING OIL--AUTOMOTIVE ESTIMATE OF USAGE, WASTE GENERATION, AND DISPOSITION IN THE USA (Following the pattern observed in the Commonwealth of Massachusetts) 1968 User Service Stations Performing Oil Changes ID User Distri bution. % 54.9 <2) Calc. U.S. Usage at % in D>. Million Gallons 658 (3) End ing as Waste () Waste. Million Gallons 15) % of (4) Col lected (6) Waste col lected. Mil. Gal. 63 415 87.7 364 (7) Waste uncol lected. Mil. Cal. 51 Other Svc. Sta. Car Dealers, Garages 1.6 16.1 19 194 0 00 0 90 175 88.0 154 0 21 Fleet Operators Do-it-yourself Oil Changers 18.8 5.4 226 65 63 142 60.0 86 63 40 0 0 56 40 Agriculture & Marine Users Total 3.2 100.0 38 1200 50 19 0 -- 791 -- 0 19 604 187 (8) Dumped on Ground Mil. Gal. (9) Sewered, Mil. Gal. 45 6 00 20 1 52 4 37 3 18 1 172 15 The total U.S. usage. 1200 million gallons (28.6 million barrels) is derived from a 1967 survey bv the Bureau of the Census--see Sources of Information, reference (7). The total was adjusted to 1968 usage bv means of information in reference (4.4), percentage distributions and disposal patterns are drawn from a survey made bv the Arthur D. Little Company in the Commonwealth of Massachusetts, reference (3'. Applying the Massa chusetts pattern to the USA as a whole involves errors of unknown magnitude: a staff estimate bv the CWQA yields a figure of 350 for the first entry in column M) above inference 2), an estimate 15.7 percent below that derived Here. The American Petroleum Institute (reference 9' terms the ADI study "indicative of present disposal practices." 0501398 I STLCOPCB4044676 TABU NO. A--3 LUBRICATING OIL--INDUSTRIAL ESTIMATE OF USAGE, WASTE GENERATION, AND DISPOSITION IN THE USA (Following the pattern observed in the Commonwealth of Massachusetts) 1968 Use Category Lubricating Oil Hydraulic Fluid (D Distri bution % 51.0 27.4 (Millions of Gallons) <2> <3) Calc. U.S. % Usage Waste M) Vol. of Waste (5) % Collect. 426 35 149 229 20 46 f6) VoL Coll. Straight Cutting Oil 10.5 88 30 26 Soluble Cutting Oil Total 11.1 93 30 28 100.0 836* 249 76 189 Data in columns (1), (3), (5), etc. are from the A.O. Little report. Bibliography Reference (3). (7) (8) (9) no) m> Vol. Un- Vol. % Volume coll'ct'd Burned Burned Sewered Sewered 100 28 60 1.2 3 28 * Bureau of Mines total lubricants, less automotive use from Table N*o. A-2. 050X399 STLCOPCB4044677 TABLE NO. A--4 FATE OF COLLECTED WASTE OIL Lslirnato of U.S. Disposal 1*rad ices Based on Massachusetts Pallern 1 9GS Millions of Gallons f nisposillon Aulfimollvr Percent' Volume Industrial IVr< ent ` Volume iot.il Vokimr* Colluded Wosli* I ule 0.1 Reprocessed to fuel Oil or Ro-refinod Used as Road Oil Used on l:arms 69.1 21.7 4.6 417 131 28 _ 52.6 "" __ TOO -- 417 231 28 Disposed of Locally down Dumps or Local RoadsJ 47.4 89 69 Unknown 4.6 28 "' 28 Total Collected 100 1 .smr/v </ W.isfe Ciii 604 - 100 f'l.uJitcN in A,tf.rss*i< 189 Uff. <:i>. 793 r Table No. A-2. a Tahlo No. A-3 TABLE NO. A--5 FATE OF WASTE LUBRICATING OIL U.S. , 1968 Summary of Eslimales in Collected and Uncollected Categories Ulimuiic 1 on* Vol ume. Millions of Gallons Volume. Millions n( 42-K.il. Horrols Distribution. Pert rnt of -r<iut i ub i<**ii Oil Used Dumped or Applied on Ground Poured into Sewers Reprocessed, Re-refined. and/or Burned Unknown 549 43 420 28 13.1 1.0 10.0 0.7 27 2 21 1 *Tolal iindinp, ns Waste 1040 24.8 51 Total Used, as Meino Item 2036 48.5 100 0501400 21 STLCOPCB4044678 BIBLIOGRAPHY 1. Environmental Quality, The First Annual Report of the Council on En vironmental Quality, U.S. Gov't. Printing Office, August, 1970. 2. Clean Wafer for the 1970's, A Status Report, June, 1970, U.S. Dept, of the Interior, Federal Water Quality Administration, U.S. Gov't, Print ing Office. 3. Study of Waste 0/7 Disposal Practices in Massachusetts, Report to Commonwealth of Massachusetts, Division of Water Pollution Con trol, lanuary, 1969, C-70G98, by Arthur D. Little, Inc, 4.0 Mineral Industry Surveys, U.S. Department of the Interior, Bureau of Mines, Washington, D.C. 20240. 4.1 Idem, Petroleum Statement, Monthly, March 18, 1969 (Preliminary). 4.2 Idem, Fuel Oil Shipments, Annual, Sept. 17, 1969. 4.3 Idem, Liquified Petroleum Gas Shipments, Annual, Oct. 13, 1969. 4.4 Idem, Petroleum Statement, Annual, Dec. 16, 1969 (1968 Final Sum mary) . 4.5 Idem, Petroleum Statement, Monthly, March 24, 1970. 4.6 Idem, Asphalt Shipments, Annual, June 11, 1970. 4.7 Idem, liquified Petroleum Gas Sales, Annual, September 30, 1970. 5. Statistical Abstract of the United States, 1969, Table 758. 6. U.S. Department of Commerce, 1969 Business Statistics, pp. 167, 168, 169. 7. Safes of Lubricating and Industrial Oils and Greases, 7907, Nov. 21, 1968, Scries MA-29C(67)-1, U.S. Department of Commerce, Bureau of the Census, Industry Division, Washington, D.C. 20233. 8. Cleaning our Environment' The Chemical Basis for Action (hook). American Chemical Society, Washington, D.C. 1969. 9. Final Report of the Task Force on Used Oil Disposal. American Petro leum Institute, 1271 Avenue of the Americas, New York, N.Y. 10020. 10. General electric Company, unpublished studies. 11. Letter to Electrical Industry from Monsanto Chemical Company, Feb ruary 18, 1970. 12. Congressional Record-- House H10214, October 14, 1970. 13. Monsanto Company, St. Louis, Missouri. 14. The Occurrence, Effects, and fate of Oil Polluting the Sea, )nt. J. Wat. Poll. Pcrgamon Press 1963, Vof. 7, pp. 173-198. Punted in Great Britain. 22 0501401 ELECTRIC AND NUCLEAR SUB-COUNCIL NATIONAL INDUSTRIAL POLLUTION CONTROL COUNCIl Chairman: D. C. Burnham Chairman Westinghouse Elecfric Corporation Vice Chairman: Fred J- Borch Chairman and Chief Executive Officer General Electric Company A. P. Fontaine president & Chairman The Bendix Corporation Raymond H. Giesecke President & Chief Exec. Officer McGraw-Edison Company Members C. Lester Hogan President & Chief Executive Officer Fairchild Camera & Instrument Corporation Robert W. Sarnoff Chairman of the Board & President RCA Corporation f tf. J*. 6 JNH OI-i'H'l. - xft'l -07-3**' 0S01A02 STLCOPCB4044680