Document yb21dBd6bdvonMB9DZ9dJ4Kd

Boilers, Steel Waterfilm Boilers Incorporated 154 Ogden Avenue, Jersey City, N. J., U. S. A. BOILERS DESIGNED AND BUILT FOR AUTOMATIC FIRING Send for full information today DE LUXE SERIES Boiler No............................... 2345 Recommended Load Square Feet E. D. R. Steam 1 Water Pickup included in tme ratings.... 500' 1 800' Steam Water 800' | 1280' Steam 1 Water Mao' 1 1760' Steam 1 Water 1400' 2240' Guaranteed B.T.U............ 120,000 192.000 264,000 336.000 Maximum Puing Rate G.PJ-L............ 1.65 gal to 2 gal 2 gal to 2i/2 gal 21/, gal to 3 gal 31/2 gal to 4 gal DE LUXE SERIES completely jacketed with either short to cover boiler only, or long to cover boiler Durner ana domestic hot water tanlr SECTIONAL SERIES Single Series No. Recommended Load ELDJL Steam Water Guaranteed B.T.U. No. Recommended Load E.DJL Steam Water Guaranteed B.T.U. 1-5 1-6 1--7 1-8 1--9 1--11 1.250 1,500 1,750 2,000 2,250 2,500 2,750 2,000 2,400 2,800 3,200 3,600 4,000 4,400 330,000 390,000 450,000 510,000 570,000 630.000 690,000 1-12 1-13 1-14 1-15 1-16 1-17 1-18 3,000 3,250 3,500 3,750 4,000 4,250 4,500 4,600 5,200 5,600 6,000 6,400 6,800 7,200 QQOflOO 1,110,000 2-8 2-10 2-11 2-12. 2-13 2-14 2-15 2-16 2-17 2-18 2-19 2-zu 2-21 2-22 2-23 4,000 4,500 5,000 5,500 6,000 6,500 7,000 7,500 8,000 8,500 9,000 9,500 10,000 10,500 11,000 11,500 12,000 6,400 7,200 8,000 8,800 9,600 10,400 11,200 12,000 12,800 13,600 14,400 15,200 16,000 16.800 17,600 18,400 19,200 - Double Series 990.000 1,110,000 1,230,000 1,350,000 1,470.000 1,590,000 1,710,000 1,830,000 1,950,000 2,070,000 2,190,000 2,310,000 2,430,000 2,550,000 2,670,000 2,790,000 2,910,000 2-25 2-26 2-27 2-28 2-29 2-30 2-31 2-32 2-33 2-34 2-35 2-36 2-37 2-38 2-39 2-40 2-41 12.500 13,000 13,500 14,000 14,500 15,000 15,500 16,000 16,500 17,000 17,500 18,000 18,500 19,000 19,500 20,000 20,500 20,000 20,800 21,600 22,400 23,200 24,000 24,800 25,600 26,400 27,200 28,000 28,800 29,600 30,400 31,200 32,000 32,800 3,030,000 3)150 000 * 270 000 3'390'000 3'5I0 000 3*750*000 3'990'000 4110 000 4)230 000 4'330'nnn 4)470000 5,630 000 5)750*000 5)870)000 5,990,000 926 Burners, Oil Electrol Incorporated FINE OIL HEATING EQUIPMENT EXCLUSIVELY SINCE 1918 934 Main Ave., Clifton, N. J. Conversion Burners, Boiler-Burner Units, Air Conditioning Units QukhWOeetrlc Electrol- Kewanee Heating Unit ELECTROL OIL BURNER Electrol-American, Series No. EA 6 Heating Unit A complete boiler-burner unit consisting of (1) exclusive design, horizontal, welded copper bearing steel firetube boiler; (2) Electrol oil burner mechanism; and (3) domestic water heater. Induced draft, low stack temperature. Integral flame. Low water and limit controls. Burns heavy furnace oil. Guaranteed minimum 80 per cent over-all efficiency. Simple, fully automatic. Attractive, sound and heat-insulated jacket. A complete automatic boiler-burner unit for the moderate-sized home. Boiler of cast iron construction. Specially designed heat absorbing surfaces. Biltin-Taco Water Heater, capacity 40 gals. (100 gal. heater can be supplied). Includes safety controls; Low Water Cut-Off, safety valve and pressure limit switch. Boiler trim: water column, combination pressure and vacuum gauge on steam boilers, altitude gauge and thermometer on hot water boilers. Fired by Electrol Model TCV Unit Cap. E.DH. Steam Col. Oil per Hour Gab. D.H.W. Three Hours Over-all Dimensions, In. LWH Burner. Bums low cost fuel oil. Heavily insulated, sound-proof jacket finished in beige enamel. Burner, smokehood, water heater and controls completely enclosed. E-K 5 E-K 10 E-K 15 750 1250 1750 1.6 2.7 3.75 50 47V, 34 55V, 80 6OV2 34 53% 100 75 34 33% Electrol Oil* Burner Famous for nearly 20 years for depend able, economical operation in any boiler or furnace. Curved air chamber produces rotating air and ball-shaped flame. Builtin Master Control, a safety that cannot become clogged with soot. Continuous electric ignition. Cut-Off Valve at Nozzle. New parts fit any existing models--elimi. nating obsolescence. Burns low cost fuel oil. One moving part. Simple, rugged, fully automatic. Summer-Winter Dom. H. W. with indirect water heater. Model Sizes Gal. Oil per Hour Min. Max. Capacity E.D.R. Steam Installed Radiation Boiler will Lbs. Oil Hr. Capacity No. Carry Sq. Ft. (4500 Btu. Taco . of (4500 Btu. Trans Water Boiler Transmission mission Heater Rate) Rate) Gals. Overall Dimensions. Ins. Steam Water L wH EA6-4 EA6-5 EA6-6 EA6-7 EA64 EA6-9 355 435 515 595 675 755 570 695 825 950 1080 1205 8.5 10.3 12.1 13.5 14.9 16.3 40 475* 293/, 54*/, 40 30% 293/, 64*/, 40 5456 29*4 54V 40 32% 29*4 5434 40 61% 29*4 40 p4% 29*4 5434 100 gab. at extra cost. Electrol Model TCV Burner Vertically Mounted The vertical mounting of the motor, fan housing and oil pump, makes pos sible the use of the TCV Burner with jacketed boilers and furnaces. It embodies all the unique Electrol Features. TC T| TU TM 1.3 1.3 2 12 3Vz 2% 8>A 24 200-1100 200-800* 600-2800 2500-10,000 Electrol Conversion Oil Burners should be selected to heat a boiler to its full rated capacity, regardless of the load that may be connected to the boiler. Standard Equipment with the Model TJ is 1140 rpm motor. With 1725 rpm motor, capacity is same as model TC. Model TCV Burner See also Pages 846-847 927 Dimensions, Ins. Gals, Oil per Hr. H w L Min. Max. 25% 21 1934 i-.-r 3.5 Capacity Equivalent Direct Radiation Steam Hot Water