MATERIAL SAFETY DATA SHEET
M-4631 September 1965
An ttP'tntrion a! fV i*mt ucetj her* * may t* loumj ;r> OS*4 29 CFR 1910 1200. MIA* norn OSHA ivgonit o> a/wa otfian
Jb(Esaantlairy almllai to U.S baparlniant el Liber Perm OSMA-20 ) Trana gananliy accaptml in Canada lor Information purpeeea)
Do Not OupScatt T*M Form. Aaquatl an Original.
PRODUCT
CHEMICAL NAME FORMULA
Molecular Sieve Type AW300 Sodium Aljminos'iicate NajO. Al;Oj. S'Oj, CaO, KjO
TRADE NAME UNION CARBIDE* Molecular Sieve
SYNONYMS
CHEMICAL FAMILY
MOLECULAR WEIGHT
Zeolite Mdecular Sieve Not Applicable
A complex of eierrarts and compounds composed of material afio*n below. NOTE. In the table beiow. the symbol "<" means "less than".
Material (cas no.) Sodium 0xid6 (1313-59-3] Ca'cium Oxide (1305-76-6; Silicon Oxide (7631-66-3)
Potassium Oxide (12136-45-7) Aluminum Oxide (1344-26-1)
Wt(H) <20 <5 <70
<5 <20
1964-1985 ACGIH TLV-TWA (OSHA-PEL)
None currently established (None currently established)
2 mg/m5
(5 mg/m5)
10 mg/m5 Total dust
(20 mppcfl
5 mg/m5 Respirable dust (None currently established)
None currently established (None currently established)
Nuisance particulate
(Nuisance dust)
10 mg/m5 Total dust
(15 mg/m3 Total dust)
5 mg/m3 Respirabie dust (5 mg/m3 Respirable
traction)
matinT BOILING POINT. 760 mm. Hg
Not Applicable
FREEZING POINT
Not Applicable
SPECIFIC GRAVITY (H,0 = 1)
1.1
VAPOR PRESSURE AT 20 C.
Not Applicable
VAPOR DENSITY (air 1)
Not Applicable
SOLUBILITY IN WATER, * by wt.
Not Applicable
PERCENT VOLATILES BY VOLUME
Not Applicable
EVAPORATION RATE (Butyl Acetate = 1)
Not Applicable
APPEARANCE AND ODOR Depending on product may appear as bead, pellet. me$h, cake or powder, odorless
IN CASE OF EMERGENCES involving this material, further information is available at all times
In the USA 304 -- 744-3467
In Canada 514 -- 645-5311
For routine information contact your local supplier
Union Carbide requests the use's of this product lo study ih's Material Safety Data Sheet i'MSDS) m.-' become aware of product hazards and sa'ety mlo'maticn. To promote sate use o' fMs product a user shou'd (i) notify its emp'oyees. agerts and contractors o' tho information on '.his MSDS ar.d any product hazards and sa'ery informal.on. (2) furnish this same information to each of Its customers lor me p'oouct, ano (3) request such customers tc notify the'r employees and customers for tne product of the same product hazards and safety information _
UNION CARBIDE CORPORATION Z MOLECULAR SIEVES DEPARTMENT UNION CARBIDE CANADA LIMITED Z MOLECULAR SIEVES DEPARTMENT
Cooyngm ' 1585 Ur.iwh Co<T>'e Corporation
00 A 061653 CONFTDFNTTAI
Page i o< 4
M-4B31
PRODUCT: Molecular Sieve Type AW-300
M-4831 September 1985
THRESHOLD LIMIT VALUE: 5 mg/m> (ACGIH 1984-85; lor respirable Oust (nuisance particulate).
EFFECTS OF OVEREXPOSURE AND EMERGENCY AND FIRST AID PROCEDURES EFFECTS OF A SINGLE (ACUTE) OVEREXPOSURE:
SWALLOWING -- No evidence of adverse effecls from available information SKIN ABSORPTION -- No evidence of adverse effects from available information. INHALATION -- May cause Irritation of the ncse and throat, accompanied by cough and chest discomfort SKIN CONTACT -- May causa irritation seen as local redness. EYE CONTACT -- May cause eye irritation seer as excess redness of the conjunctiva.
EFFECTS OF REPEATED (CHRONIC) OVEREXPOSURE: Repeated inhalation may cause lung damage
OTHER EFFECTS OF OVEREXPOSURE: None currently Known.
MEDICAL CONDITIONS AGGRAVATED BY OVEREXPOSURE: Breathing of dust may aggravate asthm8 and inflammatory or fibrotic pulmonary disease
SIGNIFICANT LABORATORY DATA WITH POSSIBLE RELEVANCE TO HUMAN HEALTH HAZARD EVALUATION: Results of one mordenite study are available A delayed fibrosis response in mice was seen following intrapentoneal Iniection ol mordenite particles 0.4-6 microns in length and 0 05-0.67 microns m width Nc malignant tumors seen.
EMERGENCY AND FIRST AID PROCEDURES: SWALLOWING -- It ingested in large quantities, then dnnk 2 glasses of water. Induce vomiting il the patient Is conscious. SKIN CONTACT -- Wash with soap and water. INHALATION -- Remove to fresh air If breathing is difficult, oxygen may be administered If breathing has stopped, administer artificial respiration. EYE CONTACT -- Immediately flush with water for 15 minutes.
CARCINOGENIC ASSESSMENT (NTP ANNUAL REPORT, IARC MONOGRAPHS, OTHERS): No information available.
NOTE TO PHYSICIAN: This product i$ a desiccant and generates heat as it adsorbs water The used product can contain matenal of a hazardous nature Identify that mata/iai and treat accordingly
Owl ) At 4
DO A 061654 CONFIDENTIAL
PRODUCT: Molecular Sieve Type AW300
M-4831 September 198$
RESPIRATORY PROTECTION (specify type): Where there ts excessive dusiiness, wear a respirator selected as per OSHA 29 CFR 1910.134 and approved by NIOSH/MSHA
LOCAL EXHAUST -- As appropriate to minimize Oust
MECHANICAL (general) -- Not Applicable
VENTILATION
SPECIAL -- Not Applicable
OTHER -- Not Applicable PROTECTIVE GLOVES: Recommended EYE PROTECTION: Safety glasses or goggles selected as per OSHA 29 CFR 1910 133 OTHER PROTECTIVE EQUIPMENT: Eyewash fountain
CAUTION: Causes eye irritation. B'eathing dust may be harmful. May cause skin irritation Open container slowly to avoid dust Do not get in eyes Avoid breathing dust and proiongec contact wi'h skm. Use with adequate ventilation Keep container closed Wash thoroughly alter handling Dc not ingest.
Before using you should know the hazards of the products to be adsorbed on the molecular sieve The products could be flammable or toxic. You should know and follow ail the safety precautions related to ihe adsorbed products
OTHER HANDLING AND STORAGE CONDITIONS; pH range if in aqueous slu'ry 8-11
The opinions expressed herein are those of quailed expens wnhn Union Carbide We believe that the informa:.on contained herem
is current as of tne date ol this Materia1 Safety Data Sheet. Since the use of this information and these opinions ana the cond tions
of use of the product are not within the control of Union Carbide, it is the user s obligation to determine the conditions of safe use
of the product
______ _________
________________ ____ ________________
UNION CARBIDE
MOLECULAR SIEVES
GENERAL OFFICES IN THE USA Umon Carb'de Corporation Molecular Sieves Dept 39 Old PidgeDury Road Danbury CT 06617-0001
IN CANADA Union Carbide Canada Limned Molecular Sieves Dep; 123 Eglmton Avenue East Toronto. Ontario MAP 1J3
Other off ces m principal Cities all over me world
M-4431 88-0048 0/8S 1M Page 4 of 4
Do a Az ^ CONF10NTIai
LMhog'aphed m U.S A
PRODUCT: Molecular Sieve Type AVV300
M-4831 September 1985
I
FLASH POINT (teat method)
Does not burn
AUTOIGNITION TEMPERATURE
Net Applicable
FLAMMABLE LIMITS LOWER IN AIR, H by volume
Not Applicable
UPPER
Not Applicable
EXTINGUISHING MEDIA: Unused material will not bjrr. Use meba appropriate for surrounding fire
SPECIAL FIRE FIGHTING PROCEDURES: Depends on the use of the material. Used matena' may contain products of a hazardous nature The user of this product must identify the hazards of the retained material and inform the fire fighters of these hazards.
UNUSUAL FIRE AND EXPLOSION HAZARDS: In their fresh unused state, molecular sieves are not flammable When exposed to water however, they can get qurte hot. When first wened they can heat to the boiling point of water Flooding will reduce the temperature to safe limits.
STABILITY| CONDITIONS TO AVOID: Moisture (water) can cause rise in temperature which may result m burn UNSTABLE STABLE
X
INCOMPATIBILITY (materials to avoid): Sudden contact with high concentrations ot chemicals having high heats of adsorption such as olefins. HCl. etc
HAZARDOUS DECOMPOSITION PRODUCTS: Hydrocarbons and other materials that contact the molecular sieve durmg normal
use can Pe retained on the sieve, ft is reasonable to expect thal decomposition products will come from these retained materials ol use The molecular sieve itself does not readily decompose unless subiected to extreme temperature or chemical cond'tions. H such decomposition did occur the product would include the mix of oxides listed in Section II
HAZARDOUS POLYMERIZATION CONDITIONS TO AVOID: None currently known.
May Occur
Will not Occur
X
# art
STEPS TO BE TAKEN IF MATERIAL IS RELEASED OR SPILLED: Sweep the spill area, collect and place the spilled material in a waste disposal container Avoid raising dust.
WASTE DISPOSAL METHOD: Discard any product, residue, disposable container or liner in an environmentally acceptable manner, in full compliance with Federal, state and local regulations
00 A 061656 CONFIDFNTTAl
Page 3 of 4