packaged oil-fired boilers
A.I A. file No. 30-C-l [M arch, 1965)
APR and APH packaged oil-fired boilers -- compact, lightweight, big on output
These lightweight big output boilers make up a cast iron line that's ideal for low-cost hydronic heating in new home construction. The key to theirefficiency is the high heat transfer rate of the THERM-O-GRID section --an exclusive American-Standard design. Both the round jacket APR and the rectangular APH are packaged for forced water circulation. For easy
installation, all controls are pre-mounted and pre wired. Both units also feature smooth-firing DH-5 Arcoflame burner and cost-reducing built-in air sep aration. l = B = R-approved outputs in the 72,COO195,000 Btuh range meet requirements in just about any size home today. For big output from a compact boiler, make it the APR or APH.
0 7
1- sturdy steel canopy-is easily removable for servicing. Integral asbestos gasket forms gastight seal.
2- controls--are factory mounted, pre-wired and easily accessible for service. Primary control features light-sensing detector for instant re sponse to ignition.
3- cast ceramic fiber refractory combustion chamber--is supported within vermiculite-lined steel container suspended from section assem bly. Combustion chamber and container can be quickly and easily replaced as a single unit.
4- insulated steel jacket-features top and front panels are easily removable for access to sec tion assembly and combustion area. Round APR jacket finished in gray. Two-tone APH jacket has brown top and side panels, light beige front.
5-model OH-5 Arcoflame oil burner is en gineered to provide top operating efficiency. EXACT-AIRE control and special turbulator-disc combination insure proper air-oil mixture for clean, economical firing.
APH-185 shown m cutaway
THERM-O-GRID, Arcoflame. EXACT-AIRE and ELIMINAIRE are trademarks of AR&SS Corp.
The exclusive THERM-O-GRID is a compact, light-weight cast iron section designed to pro duce a high ratio of heat output per pound, through the use of tubular-finned surfaces. When assembled in the boiler (far right) the tubes and fins oppose each other to increase flue gas turbulence and further improve heat
transfer. Air removal is accomplished inter nally by using the ELIMINAIRE principle. Air collects in top section and passes directly to expansion tank through a special tapping. No additional external device is necessary.
SL1
mmmm
mmmm
00347
APR & APH
packaged oil-fired boilers
APR and APH ratings
boiler number
grass l=B=R
output (Btu/hr)
net l=B=R ratings water (Btu/hr)
l=B=R burner capacity (gph)
chimney
size (inches)
height e (feet)
water content (gallons)
APR-72 APR-90
72,000 90,000
54,000 67,500
0.70 0.90
8x8 8x8
15 15
2.1 2.7
APH-115
115,000
86,300
1.15
8x8
APH-150
150,000
112,500
1.45
8x8
APH-185
185,000
138,800
1.80
8x8
15 15 15
3.4
4.4 5.4
Nozzle sizes, gph, furnished with APR end APH packaged boilers: APR-72. 0.75-60$; APR-90, 0.85-60S; APH-115, 1.10-60S; APH-150, 1.35*60S; APH-185, 1.75*60$.
Net I = B = R ratings shown are based on a piping and pick up allowance of 1.333. American-Standard should be consulted before select ing a boiler for installations having unusual piping and pick up requirements,
e Measured from top of canopy. Note: APR and APH packaged boilers furnished for forced hot water circulation.
dimensions and tappings
e
boiler
number of THERM-0-GRID
size of tappings (inches)
number sections* flow return
dimensions (inches)
AB
APR-72 APR-90
3 4
1 1 35V* 29% 1 1 38V* 32%
APH-115 APH-150 APH-185!
3 4 5
IV* IV. IV* IV* 1% IV.
37% 40Vi 43%
31% 34% 37%
THERM-O-GRID section dimensions and weights: APR boiler: 12x12x3" 30 lbs.; APH boiler: 15x15x3", 51 lbs.
section thru boiler
APR and APH packaged oil-fired boilers are designed and built to comply with the American Society of Mechanical Engineer's Code, and bear their approval symbol. Ratings have been approved by the Institute of Boiler and Radi ator Manufacturers. The Model DH-5 Arcofiame Oil Burner is listed by the Underwriters' Laboratories, Inc.
for No. 1 and No. 2 fuel oil; complies with Commercial Standard CS-75; and is approved by the New York City Board of Standards and Appeals, by the State Fire Mar shal of the Commonwealth of Massachusetts, and by the Department of State Police, State of Connecticut.
WAmerican-<$tan d a rd
00348
AFR&AFH
packaged oil-fired boilers
near boiler piping
APR basic wiring diagram
Procedure for filling series loop Heatrim System:
1. Close all zone valves except zone to be purged. 2. Open boiler drain valve. 3. Open fill valve. 4. Close purge valve. 5. Vent air from boiler by manually opening relief vaJve. 6. Open second valve to be purged. Close first zone. After second zone
is purged, open third zone valve and close second zone. Repeat for as many zones as in system. (Note: Always have one zone valve open). 7. When all zones have been purged, close boiler drain cock. 8. When water appears at relief valve, release lever and allow to close. 9. Continue filling until pressure gauge reads approximately 12 Ibs./sq. in. Close fill valve. 10. Open purge valve.
Note 1: Where multiple circuits are used without zone valves, balancing valves should be installed for balancing. These valves can be shut off to purge each circuit individually.
Note 2: For a single loop Heatrim System, no additional vents, valves, drains, or other accessories are required.
APH basic wiring diagram
crated dimensions
boiler number
dimensions (inches) HW L
approximate shipping weight a (lbs)
APR-72 APR-90
37% 40%
22% 22%
28% 28%
306 344
APH-115
APH-150 APH-185
39% 42%
45%
27Vz
27Vz 27%
34
34 34
330
375 420
OH-5 Arcoflame burner shipped in separate carton.
front W
side
Form No.85 2
American-Standard
PLUMBING AND HEATING DIVISION
AMERICAN RAOIATOR & STANDARD SANITARY CORPORATION 40 WEST 40th STREET * NEW YORK, N.Y. 10018