Document yRwdBZ8O7RVozO83LbZgxorD

62 CHAPTER 5 . 1960 Guide Table 7.... Analytical Solutions for Heat Conduction in Variously Shaped Solids (Concluded) Shops of Solid Boundary Conditions Data Avatlabie in Graphs Sphere immersed in.fluid. Rectangular bar of infinite length. The' temperature of the surrounding fluid suddenly changes from the initial uni form sphere temperature. Temperature distribution as a function of time. References: (4) p. 36; (5) pp. V-21, V-35, V-44; (10) pp. 281, 282. Heat flow as a function of time. References: (5) p. V-21; (10) p.28l. Any of the above Doted boundary condi tions for a slab. Temperature distribution as a function of time. Combine solutions as indicated in Refs. 16 and 17. Parallelopiped (rectangular). Any of the above noted boundary condi tions for a slab- Temperature distribution as a function of time. Combine solutions as indicated in Refs. 16 and 17. Cylinder of finite length. Any of the boundary conditions given above for a cylinder and a slab. Temperature distribution as a function of time. Combine solutions as indicated in Refs. 16 and 17. Hollow cylinder of infinite exterior ra dius. The temperature of the surface suddenly changes from the initial (uniform) tem perature. Temperature distribution aa a function of time. Combine solutions as indicated in Refs. 16 and 17. Heat flow at the surface as a function of time. Reference: (10) p. 267. most direct use in problems in which the boundaries of the two-dimensional shape are made up of isothermal and ad iabatic surfaces. REFERENCES 1 T, K. Sherwood: Absorption and Extraction (McGraw-Hill Book Co., New York, 1937). * Griffith and Davis: The Transmission of Heat by Radiation and Convection (Department of Scientific and Industrial Re search 8-pedal Report No. 9, His Majesty's Stationery Office. London, 1933). I A. P. Colburn: A method of correlating forced convection heat transfer data and a comparison with fluid friction (Ameri can Institute of Chemical Engineers Transactions, Vol. 29,1933 P- 174). * W. H. McAdams: Beat Transmission (McGraw-Hill Book Co., New York). * L. M. K. Boelter, V. H. Cherry, H. A. Johnson, and R. C Martinelli: Beat Transfer Botes (University of California Press Berkeley, 1946). * V. a. Touloukian, G. A. Hawkins, and Max Jakob: Heat transfer by free convection from heated vertical surfaces (ASMS Transactions, 1948, p. 13).' * R. H. Heilman: Heat insulation in air conditioning (In dustrial and Engineering Chemistry, Vol. 28, 1936, p. 782). . * L. M. K. Boelter, J. T. Gier, and F. A. Ryder: Photoelec tric photometer for rapid comparison of two light sources (Ilhaninalina Engineering Sodety Transactions, 1939). * Perry Moon: Scientific Basis of Illuminating Engineering (McGraw-Hill Book Co., New York, 1936). ** Max Jakob :Beat Transfer (John Wiley A Sons, New York Vol. 1, 1949). II L. E. Grinter: Numerical Methods in Engineering (The Macmillan Co., New York, 1949). ** G. M. Dusinberre: Numerical Analysis of Heat Flora (Mc Graw-Hill Book Co., New York, 1949). 11 Max Jakob: Elements of Beat Transfer and Insulation (John Wiley A Sons, New York, 1942). ** H. A.'Johnson: Periodic heat transfer at the inner surface of a homogeneous wall (ASHVE Transactions. Vol. 54. 1948 p. 143). 11M. P. Heislcr: Temperature charts for induction and con stant temperature heating (A8MB Transactions, Vol. 69. 1947 p. 227). 11 F. C. W. Olsen: Temperatures in solids during heating cooling (Industrial and Engineering Chemistry, Vol. 34. 1942 p.874). 17 T. K. Sherwood and C. E. Reed: Applied Mathematics in Chemical Engineering (McGraw-Hill Book Co., New York. 1939). u H. S. Carslaw: Introduction to the Mathematical Theory of the Conduction of Beat in Solids (Dover Publications New York, 1945). ** L. R. IngersoM, A. C. Ingereoll, and O. J. Zobel: Beat Conduction (McGraw-Hill Book Co., New York, 1948, p. 209). M H. P. Gurney and J. Lurie: Charts for estimating tempera ture distribution in heating or cooling solid shapes (Industrial and Engineering Chemistry, Vol. 15, 1923, p. 1170). T. K. Sherwood: Applied Mathematics in Chemical En gineering (McGraw-Hill Book Co., New York, p. 241). A. Nessi and L. Nissolie: Mtthodes Grapkiquet pour L ttude des Installations de Chauffaqe et de Rifrigdation en Rigims Discontinu (Dunod, Paris, 1949). ** ?* b ,PenT aod W- P- Berggren: Transient Beat Conduc tion in Hollow Cylinders after Sudden Change of Inner Surface Temperature (University of California, Publications in Engi neering 5, Vol. 59, 1944). ** v. Paschkis: Method for determining unsteady -state heat transfer by means of electrical analogy (ASMS Transactions, Vol. 64, 1942, p. 105). CHAPTER 6 PHYSIOLOGICAL PRINCIPLES Chemical Vitiation of Air, Physical Impurities in Air, Thermal Interchanges Between the Body and Its Environment, High Temperature Hazards, Acclimatization, Upper Limits of Heat for Men at Work, Application of Physiologic Principles to Air-Conditioning Problems, Effective Temperature Index and Comfort Zones AN understanding of physiological principles is essential odor adsorbing capacity of air-conditioning processes, and X"V in the proper design of air conditioning systems for temperature and relative humidity. The intensity of odor spaces intended for human occupancy. The term air condi sensation h been found to vary as the logarithm of the con tioning in its broadest sense implies control of any or all of the physical and chemical qualities of the air. Ab defined in centration of the odoriferous substance in the air, or inversely with the logarithmic function of the amount of outdoor air Chapter 1, comfort air conditioning is the process of treating air so as to control simultaneously its temperature, humidity,, cleanliness, and distribution to meet the comfort require ments of the occupants of the conditioned space. supplied and the air space per person. The relation between air supply and occupancy has been reported by the Harvard School of Public Health1 (Table 1). and the ASHAE Research Laboratory.* Outdoor air require CHEMICAL VITIATION OF AIR ments for removal of objectionable tobacco smoke odors are not accurately known, but available information and current People living indoors bring about certain' physical and chemical changes in the air about them. The oxygen content of the air diminishes and the carbon dioxide increases, but practice indicate the need of 15 cfm per person or more." The total quantity of outdoor air to be circulated through an enclosure is often governed chiefly by the physical eon- these changes are too slight to be significant except in air tight spaces as in submarines. Orgamc_matter which is usually perceived as odors, comes from the body or clothes. Table 1 .... Minimum Outdoor Air Requirements to Remove Objectionable Body Odors Under laboratory Conditions1 Moisture and heat are given off by the body. There is no evidence of any toxic volatile material given off by man to the ambient air. Stale air may be offensive because of odors and may induce loss of appetite and loss of energy. Ob Type of Occoponfi Air Space per Pertofl Cu ft Outdoor Air Soppiy CFM per Perron jectionable body odors have the same effects. These reasons, whether esthetic or physiological, usually make it desirable in Hooting ioon with or without recirculation. Air not conditioned. the design of air-conditioning systems to provide for the elimination or control of odors arising from occupancy, cook ing, or other sources. This may be accomplished by intro ducing odor-free air in sufficient quantities to reduce odor concentrations by dilution to a level which is not objection Sedentary adults ol average socio-j economic status....................................... \ 1 100 300 500 25 12 7 able. Odor-free air may be outdoor air or air which has been cleared of odors by sorption, washing, or other appropriate Laborers........................................... ................ 200 23 means. In the case of vitiation by a few hazardous gases such as carbon monoxide from heating, cooking, and certain in dustrial processes, no satisfactory chemical treatment for the elimination of the impurity has been found. The only satis Grade school children of average socioeconomic status....................................... 100 200 300 500 29 21 17 11 factory solution is elimination at the source by local exhaust ventilation; or, if this is impossible, reduction to a safe concentration by dilution. (See Chapter 7.) In the case of contamination by other matter, including volatile vapors and gases, chemical treatment for the removal or reduction of the impurities has been made available through air cleaning Grade school children of lower socioeconomic status......................................... Children attending private grade schools........................................................... 200 100 38 / 22 methods, which are discussed in Chapter 24. When the only source of contamination is the human oc Heeling troion Air humidified by meon* of centrifugal humidifier. W ater atomization rate 6 to 10 gpfa. Total atr circulation 30 cfm per perron. cupant, and overheating is not a problem, the minimum Sedentary adults........................................... j 200 I 12 quantity of outdoor air needed appears to be that required to remove objectionable body odors, or tobacco smoke. The con Summer season- Air cooled aod dehumidified by means of o spray centration of body odor in a room, in turn, depends upon a number of factors, including the dietary and hygienic habits dehemidifief. Sproy water dienged dotty* Total air drariatmn 30 cfm per person. of the occupants (frequently reflecting their socio-economic status), the outdoor air supply, air space allowed per person. Sedentary adults. <4 63