Document yMVaa44M5wEO1YjoQRw0ZO3X

hintftcV of Uiv Ar.br:>to3 Tnxtile Im'titut: Mi* Hyglmio niul HniiuIduUn Ca*7il<.t<!j ~ Lacombor 5/ 1957 PLAINTIFF'S 1 EXHIBIT G-3 1 3 . In attendance: V\ C. Atkinson ii. Jackson E. W. huttenborger A i rlfly T.. C* uikey J. L. hitcholi U, C. Seeds P., n. Crdth J. H. \feUer Johns-IIur.villo Cr.rp, t N Unybostos-lbinhaltan, Inc. Reasbey It Hattlson Co* Tallmar.-JlcCluukcy Fabrics Co, Southern Asbestos Co, Joluia-3-tanvillc Corp, rtaybistos-llanhattcn, Inc. Amorican Asbostos Textile Corp, taking on aetivo part in tho cue tine; 1, I!r. Hugh Jackson roported that tho study being conducted by tho Industrial Kygicr.0 Foundation for the Queboe Asbestos ilinero Association has boon . completed but is not availablo. . Tlio report will bo diocuased at tho next cox-lttoo iooting. .: arm. 2, Kr. Luttenberger reported that Dr, Haior is continuing his work on the percentage and typo of dust received in various rau fibore. Tho ALr Kygicni and Manufacturing Casmittoe is interested in the work of `he Filer Evaluation Cerrattoo ar.d would appreciate being advised cf their proceedings and plans for tho future, 3 Public Kelnticns and employee relations were briofly discussed, It was the consensus of opinion that a greater effort should be made to frovido new workers with correct information as to the naturo of our industry ar.d to acquaint the noireors of tho connunity, arid in particular, the nedical *r.d nursing professions of the conditions in'our plants. Two companies reported of the increased good trill which resultod after various groups had visited their plants. ' It, Kr, John V.'ebcr reported onbis recent trip to-Europe wlioro ho vi? Lt.cd textile plants in Franca. Hr, Webor stated that in gcnoral tho machines do not opnratn at aa high a spool as the Aaoriean machines. A now doslgn spinning framo of Italian awhfaciuro was being installed. Theno frizes worn equipped with n vnriablo eppod spindle drivo which reducod tho speed of the spindlo when winding on tlio i:;.por part of tho bobbin* 5. The effectiveness of the hoods now ir. uso over tlio broadclotli looms van *. ` discussed* 'Tao companies advised tliat thoy had installed now experimental hoods on couo of their loses and wero considering replacing nil of the hoods with.the new design. Thn experimental hoods worn of tho ovorhoad typo with two iloo:*o on each nldo to permit accoss to tho loom* ` 6, One cc.~p.arjr reported that in a recent dust count taken in their card reen, all counts, except one taken at n feeler, uero below 3,6 million particlns ' per cu. foot* Anothor company repertek--hat their average count was new 2.7lt million particles per cu, foot* . . Minutos of the Asoc'-tns T':*U).a Inct: tuln Air i'/Cii'o and K.-.nulacturi:i,; Coiimitt ce-Dce. 5, 17^7 f*ac 2 Tiio rcuso ef air from tho dust collectors was discussed nnd tho importance of geed distribution, was caphasitod, to reduce the effects of drafts on tho workers and machinery. Ur. Seeds of Jolms-lunville reported that a duct oysten, in uhleh tho roturn of ai.r was discharged at. the ceiling, vas qaito satisfactory. Hr. Smith reported that tho tost holes in tho duet work of their dust collecting system aro made by drilling a hole through the duet where a pipo coupling has bcon brazed to tho duct, when tho holes are not in uso they aro sealed with a pipe plug. This insures that all readings will be taken in the sane location at each teat. The members report that routino tests are conducted from one to four times a year in their plants. Tho cosrittee discussed the problem of dust being generated at the rub aprons on tko card condensers. This dust is not being collected in Most plants at tho prosent tir.o. Kcthods of control will be aiscussod at future meetings. Tho solcetioii and use of respirators wore thoroughly discussed by tho . committee. Tho points covorcd are well suanerizedvin tho attached paper by !ir. Jackson. Tho agenda for the next meeting will include tho following: . Vacuts-i cleaning for dust control. Mr. iiit-chcll has prcaisod to bring data cn tho Abington system recently installed. fc. Tho Q.A.K.A. report, . c. Dust control uothods in U;o fiber propera tion department. ' d. Continued diocussion of dust in fiber, o. Continued discussion of Dust Collectors and Hcmoval of Dust at machinos. Kespectfully cubmitted A, E. Hay, Chairman . KK'"jiaT(4i:; 5>.o '.i:.o of r":-pir:ito:*5 ns n Re:j;wi of protccling an operator against ia.;r>surr: 15 Ip.s:i<::;V-;a> oS>'.'*ij'l. bo regarded uz 1.1 ic 3asl lino of dofonoc. The enptr.eerir;'. ap proach lo accident prevention is valid for Uia prevention of occupational disease, 3.^d err.lrol measures should bo given consideration in tlio following ooquencoi 1/ ' i. eliminate, 2. isolatu, - - 3. r-ininizo, mid. In protect the operator. a situation exists in which it is impassible or iupraalical to Accomplish aanquato control by means of the first throe steps, protection of the operator is, of course, imperative. It should bo rccor.nicud, however, that the acceptance of tl;is last a7.proacli places additional responsibility upon tho supervisor to insure that tho protective dovico io consistently and properly used. As with any other tool, respire.tors are designed for r.pocific purposes and exposures anl must he used accordingly. The United Staler Qureau ef iltncs is the ngoncy which establishes the standards and specifications for rcopirator dosirn and performance. Their circular t!76j6 contains a list of gas casks, supplied air ronpirators, dispnrsoid respirators and non-cmcrgcncy gas rospira- tors, approved for a varioty ef exposures# 'Asbestos*, being a particulate* dust'which is toxic through inhalation, falls into the category ef pncumonoconiosis producing dust (defined on pago ? of circular u(ojG)m -l/ A.-cr.i; a nu;:.er of criteria established l.y tho U. U. Ilurcau of I in*. rrtjuir-.- cor.t that rcsis t-ii.ce in tho respirator to nlr flow at tho rate of 3 cubic feet (o3 iit.i rs) por i.itnuUi for inhalation should not exceed 2 inches (50 ciUimetorr. of water), and for expiration should not oxcccd one inch (25 millinctors of water). Other criteria include specifications of the amount of dust of designated sir.c will eh will pass through tho filtering medium, as veil os specifications of tho fit of tho respirator faco picco on different facial contours. Thera aro a number of factors which ohould be given consideration fer celoeting tho otylo and cake of approved typo rospirators for plant uso. 1. Resistance ' . Host respirators on tho market today havo breathing rnslstmv.o nuch lower than the U.3.0.3. standards. Zn a series of ten respirators . free four major supplicro, U10 rosistnneo rating ranges from 13.0 millimeters to 27.7 millimetors, compared to the standard of 50 : : millimeters, {At best, the woaring of a respirator io a nuisance to rthe operater and tlio lovest possible breathing rosistance minirdcoo gtltis nuisanco valuo. j ' - * ' 2 Filtoring Capacity . . Tho square inches of filtering surface varies considerably in different, models of ronpirators. 01von the same dust load, the respirator with a largnr filtering surface will build up breathing reels tonco et e much filowor raw than ono with n omnllcr filtering arna. Thin facet, would hnvo lts.pracU.c.'l appl.i.cation ii. delomir.ing hew frequently '.ho rf.'iplrator filtering ir.cdiun would havo to bo changed. j, Weight In tiie sane group of ten reaplraters, tho weight or the veriosis otylcn varied frea 1.25 ounces to 9*0 ounces. In general, the linhtcr weight units havo ft smaller filtoring aroa und, thorefore, tlie weight factor, which is important to pporator comfort, must be balanced against tho replacement requirements, prodicatod on tho filtering capacity (Itom 2 above. * It. Facial Fit . Although tho U. S. B E. epees require a tight fit on three standard types of fecial contours, *it lo oftentimes difficult to obtain tho '.tight`fit essential for positive protection of any given individual. Thr. '.operator usually r.oeds considerable instruction regarding tho placement, (.and adjustment, of-tho-respirator to his particular foaturcs. s 5. Distribution . ,. .............. ,.......................... Cn.' method' of distribution is to have tuo respirators identified for . ,i>ach nan. Uhilo one is being uorn, the other is being cleaned and inaintr.lned end lo returned to that individual. As can bo readily ap- precis ted, turnover and Job transfor odd complications to this method of distribution. A oocond tochnlquo is to arrange for daily or periodic pick-up ant; nolivery of respirators to a given distribution point, (forcr.-.cn's office, deportment store room). All rospJrators picked up after a period of uso aro cleaned and sanitised and rodistributod without rofcrcnco to the point of oorlier uso. *. r 6, Maintenance It is rocusaonded that msintenanco of respirators bo done at a control location by an authorised individual. A regular schedule of * pick-up, maintenance and distribution should bo established. The '* regular maintenance should consist of- wachlng and clean! ng with e ; sanitizing compound recommendod bythe respiratormanufaeturor oadkV - . tho inspectien and replacement of oachofthafhRCtioaal or eontset portions of tho respirator.' Certain of the filtering mediums can bo 7 cleaned and reused.. Others nro designed for ono uso application only. * It:iS essential, thorofore, tluit all working and centeet parts be in 1 'first class.order, othorviso the effectiveness of tho respirator may - t be. ontiroly_nogatod 1 . .. 7*. Programming ' ' Arnes of enpesuro wliieh ennnot bn satisfactorily controlled by other ' engineering moans should bo identlfind end tho use of respirators in those portions be made n mandatory job requirement* Since the wearing of respirators doos const!luto an element of nuisance and foilguo* tho job evaluation should provide appropriate allowance for this factor. -r _ 1-J,i,"ley!',s'ahoulrt be given sufficient know]c*l|y of the nai.wio of Urn J7 f rrcponvirr and potent?nl har.anl that. they will understand anti appreciate J 'itho vrluo of the protectivo d-rvice. Discipline should bo used to '. insuro t.he coixcct awl consistent uso of-ror.pirnl-oro whero sneh ora . a job riv>ui:'cmcnt4 in tho some aannor os would bo tho caso for an/ otl.or infraction of job wothods, ... tScmnnlos cf respirntoro which hnvo brwtlii;ic reslatanco In thn 13 to 10 pillinctur range rind aro light weight (1.2? to 3*0 ounces) arc Uso Kino Safety Appliancos Pustfoo 55* Pulauoan 600, Asar.rican Optical R-2000 and Willson Hsno-Hask 600, Each of tho aajor respirator nanufacturcrs offers cleaner- oonitlzor products for roapirator maintenance* . ) I ;.